Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date10 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 22,31,000
Costs
EMD
₹ 44,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665172_1Tender No
8070/NIT-52/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece not less that 450 mm long 15 mm dia PVC hot/cold type alonwith double ended brass socket and connected with geysers and stop cock, complete all as specified and directed Engr-Incharge.
68
-
-
Supply and fixing socket outlet 16 Amp 230 volt ISI Mark complete all as specified and directed
68
-
-
Supply and fixing switch , single pole, one way 16 Amp 230 volt ISI Mark complete all as specified and directed
68
-
-
Supply and fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, complete all as specified and directed.
24
-
-
Supply and fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and complete all as specified and directed.
88
-
-
Stop valves 15 mm , cast copper alloy, screwed down, high pressure, fancy type, chromium plated , screwed both ends for iron pipe or for unions and fixed
136
-
-
Bib taps 15 mm , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule chromium plated and fixed
68
-
-
Tubes, medium grade 15 mm bore' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors
136
-
-
M & L for sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 4 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments including PVC conduit and draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FRLS PVC insulated and PVC conduit 25 mm dia shall be measured and paid as one unit length
378
-
-
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe light grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate
24
-
-
supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 Core.Complete all as specified and directed by Engr-Incharge.
345
-
-
Excavation in trenches in Hard and dence soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles,cables laying etc. including forming bottom to required level and getting out in soft/loose soil ,Complete all as specified and directed by Engr-Incharge.
74.52
-
-
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.Complete all as specified and directed by Engr-Incharge.
37.91
-
-
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.Complete all as specified and directed by Engr-Incharge.
25.27
-
-
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation ,Complete all as specified and directed by Engr-Incharge.
Note: Punned thickness shall be considerd for measurment purpose
24.22
-
-
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable Complete all as specified and directed by Engr-Incharge.
2.4
-
-
Stop valves 15 mm , cast copper alloy, screwed down, high pressure, fancy type, chromium plated , screwed both ends for iron pipe or for unions and fixed complete all as specified and directed Engr-Incharge.
120
-
-
Bib taps 15 mm , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule chromium plated and fixed complete all as specified and directed Engr-Incharge.
60
-
-
Tubes, medium grade 15 mm bore' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors , complete all as specified and directed Engr-Incharge.
240
-
-
M & L for sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 4 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments including PVC conduit and draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles complete all as specified and directed Engr-Incharge. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FRLS PVC insulated and PVC conduit 25 mm dia shall be measured and paid as one unit length
320
-
-
M & L for point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheated cooper multi standed conducto of size 1.5 Sqmm, 1100 Volts grade drawn in and including rigid non metallic white/ivory PVC conduit medium grade ISI marked not less than 20mm dia with all conduit acccessories/thickness not less than 1.6mm with earth dolly and bakelite laminated sheet 3mm thick ISI marked for fixing of switches/sockets, fan regulators, wall mounting fittings, door bell and bulkhead etc wiht MS screw and cup washers including PVC FRLS insulated and unsheathd copper multi standed conductor of size 1.5 Sqm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching/finishing of new surfaces either by means of plaster of peris/putti or distemper/colour wash with same existing colour surfaces all as specified and directed by Engineer-In-Charge
40
-
-
S & F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed
40
-
-
S & F socket outlet 3 pin , 6 Amp piano flush type including complete all as specified and as directed
40
-
-
Supply and installation of desert cooler with outer body made of PGI (Plane Galvanised Iron) sheet not less than 1.20 mm (18 gauge) thickness for fixed part thickness of PGI sheet for shutter not less than 0.80 mm (21 gauge) thick front grill made of PGI sheet overall outer size not than 666cm x 66 cmx 86 cm (height) electric driven copper wounded fan motor having nominal air flow capacity of 4000 Cum per hour and capacity of water storage than not less than 40 Ltr and submersible pump for required flow of water single phase 3 step rotary switch, singleway on /Off swithc complete all as per speicified
40
-
-
S & F framed work such as grills, ATC ends of bars shouldered and/or riveted or forged into spikes framed guard bbars barred iron dorrs, ladders framed blausters walk ways, railing frame work of Desert cooler and similar work conforming to Fe 290 Gde-E 165 indicated or dirtected and inclusive of one primer coat, one under coat and one finining coat of aluminium paints completed all as specified and dirtected.
406
-
-
Deduct Schedule of Credit of Rs. (-) 0.00 (Minus) as listed in Schedule 'A' Part-II.
Contract Sum shall be arrived after deducting the credit amount
Note: Tenderers will not quote against this item being a firm amount.
-
-
-