Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date31 Aug 2024
Closing Date8 Oct 2024
Tender Amount₹ 46,08,000
Costs
EMD
₹ 92,160Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669285_1Bid Award Id
ViewTender No
864/WS-57/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F 2nd class hard wood factory made plain framed panelled shutters 35mm thick (any number of panel) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified.
6.7
-
-
S&F 35mm thick (factory made) glazed and skeleton shutter open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/gauze etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) of IInd class hard wood complete all as specified and directed.
4.5
-
-
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed.
3.6
-
-
S&F 100 mm size mild steel butt hinges medium weight cold rolled complete all as specified and directed.
30
-
-
S&F 150mm size aluminium anodised barrel tower bolts of extruded sections complete all as specified and directed.
12
-
-
S&F 150mm size extruded aluminium handles fabricated type, anodised complete all as specified and directed.
12
-
-
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
3
-
-
S&F in repair 300 mm, MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified.
6
-
-
S&F in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5.5mm thick tinted glass and partly panelled with 9mm thick decorative prelaminated both side particle board exterior grade including rubber bead, jointing cleat for fixing, aluminium door handle 150 mm size and tower bolt 200 mm size, governing brass pivot, mortice lock vertical type of mild steel 4 levers of size 100mm etc complete all as mentioned here-in-below and as directed:-
(a) Frame (top & side) section 101.60 x 44.75 x 2.40mm thick (Section No. 14021)
(b) Vertical members of shutter section 85.00 x 44.45 x 2 mm thick (Section No. 19560)
(c) Top members of shutter section 83.50 x 44.45 x 2 mm thick (Section No. 19581)
(d) Lock rail (Middle member) of shutter section 150.00 x 44.45 x 3 mm thick (Section No. 19596)
(e) Bottom members of shutter section 150.00 x 44.45 x 3.10 mm thick (Section No. 19584)
(f) Glazing clip for securing glass - 0.80 mm thick (Section No. 19370)
Note :- Section No. given above are of make Jindal/ Indal/ Hindalco
18
-
-
S&F aluminium window openable/fix type with aluminium anodized frame of section 62.30 x 44.50 x 1.5 mm with shutter stiles rail of aluminium section of size 47.62 x 44.45 x 1.5 mm thick including jointing cleat for fixing binder hardware glazing clips rubber packing for air lock purpose anodized aluminium strip bearing screw etc for fixing glass pans in frame shutter covered with fully selected quality tinted glass 5.5 mm thick with rubber packing and aluminium (anodised) grill square, rectangular or similar section fixed with channel of size 38 x 12 x 13mm etc complete all as specified ad as directed. Make: Jindal/ Indal/ Hindalco.
11
-
-
S&F in repair 20mm dia mild steel chromium plated, fancy type curtain rod with brackets and knobs at both ends complete all as specified and directed
15
-
-
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
15
-
-
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 etc complete all as specified and directed.
18.2
-
-
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
120
-
-
S&F mild steel as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410-W Gde E-250, quality 'A' including dismantling old iron articles complete all as specified and directed.
840
-
-
S&F welded steel wire fabric to wood or steel members weight not exceeding 4 Kg per square metre including dismantling old steel wire fabric complete all as specified and directed.
62
-
-
M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
219
-
-
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
122
-
-
Demolition of plain cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all specified and directed.
30.3
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) etc complete all specified and directed.
30
-
-
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in sub base/levelling course complete all specified and directed.
657
-
-
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed in CM 1:6 complete all specified and directed.
154
-
-
M&L for coloured glazed ceramic tiles on vertical surface as in dado skirting etc of size 350x250x7mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile fixed over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
205
-
-
Dismantling of wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards/slabs, any thickness, including cover fillets complete all as specified and directed.
314
-
-
S&F anodised aluminium snap grid frame work for false ceiling having size of grid 600x600mm including hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and providing and fixing decorative designed pattern (as approved) Gypsum board 12mm thick in ceiling fixed with screw or as per manufacturers instructions complete all as specified and directed.
434
-
-
M&L for brick work with subclass 'B' bricks, straight or curved on plan any radius, built in cement mortar 1:4, in half brick thick wall complete all as specified and directed.
14.5
-
-
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
30
-
-
M&L for preparing newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified.
30
-
-
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
30
-
-
S&F 20mm thick 2nd class soft wood boarding, clean swan, fixed in eaves board with nails complete all as specified and directed.
30
-
-
S&F 6mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work in wall complete all as specified and directed.
25
-
-
M&L for 6mm thick veneered decorative plywood, grade-1 (with BWR resin) with decorative face veneers on one side face, fixed with nails to timber frame work complete all as per specified and directed .
25
-
-
Dismantling of plain or corrugated steel sheeting, any gauge thickness , including nanital or similar pattern roof covering complete all as specified and directed.
62
-
-
S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with coach screws and washers, in roof, wall etc with grade of zinc coating 275 complete all specified and directed.
52
-
-
S&F 0.80mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, fixed with coach screws and washers complete all as specified.
10
-
-
M&L for Vitrified Ceramic tiles 9-10 mm thick (square/ rectangular) light shade, polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile laid over and including 15mm thick screed bed in CM 1:6 complete all specified and directed.
337
-
-
M&L for 75mm thick PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in plinth protection, finished concrete surfaces even and smooth without using extra cement and filling joints with bitumastic filling in proportion bitumen and coarse sand mixture. 1:2 complete all as specified and directed.
25
-
-
M&L for 100mm thick PCC (1:2:4), Type B-2 (using 40mm graded crushed stone aggregates) as in sub base of floors etc. complete all as specified and as directed.
25
-
-
M&L for chequered cement concrete tiles with grey cement and pigments 30cmx30cmx22-25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
25
-
-
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified & directed.
1.5
-
-
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick (horizontal or sloping in rough finished surfaces of concrete complete all as specified and directed.
15
-
-
M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, manhole covers and in shelves and the like including use and waste formwork complete all as specified and directed.
1.5
-
-
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all specified and directed.
1630
-
-
S&F 2nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads sectional area exc 6 but n. exc 13Sqcm complete all as specified and directed.
162
-
-
S&F 10mm thick 1st class soft wood Australlian wooden panelling fixed with toughened and grouted as wall panelling including fillets/cornices & 9mm thick plywood BWR fixing on walls and finally finishing with french polish (two or more coats) complete all as specified and directed. Note: Rates for disconnecting of electrical connections from main DB and removing all switch socket, sheet metal enclosures and fittings & fixtures and refixing the same and making electrical connections as directed after completion of work deemed to be included in quoted rates.
110
-
-
Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for foundation, shafts, cesspits, manholes, pier holes etc. not exc 10 Sqm on plan and getting out in hard/dense soil, complete all as specified and as directed.
241.59
-
-
M&L for PCC (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundations, filling and mass concrete, complete all as specified and as directed.
30.2
-
-
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and directed.
96.28
-
-
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping, benching cills, roof kerb, seismic and other similar bands and the like including weathering slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
10.18
-
-
M&L for PCC (1:2:4), Type B-2 (using 40mm graded crushed stone aggregates) as in surface channel and drains including necessary form work concrete complete all as specified and as directed.
12
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed.
299
-
-
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
418.6
-
-
Removing of excavated soil to a distance exc 50 mtr but not exc 500mm and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and directed.
241.59
-
-
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
166
-
-
Removing of excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and directed.
24.9
-
-
M&L for 75mm thick PCC (1:4:8), Type D-2 (using 40mm graded crushed stone aggregates) as in sub base of floors etc. complete all as specified and as directed.
166
-
-
M&L for chequered cement concrete tiles with grey cement and pigments 25cmx25cmx22-25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
166
-
-
M&L for Vitrified Ceramic tiles 9-10 mm thick (square/ rectangular) light shade, polished, area of each tiles not exceeding 0.36 sqm on vertical surface as in dado skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile fixed over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
6.5
-
-
S&F 9mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work in ceiling complete all as specified and directed.
165
-
-
M&L for cutting of road as required (approx 9.25M each length) for laying RCC pipe line under road including repair/making good surface as per existing with filling of earth, boulders, WBM, BM etc and top surface finished with 30mm thick ready mixed patch filler complete all as specified and directed.
2
-
-
S&F 200mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and directed.
12
-
-
M&L for precast RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in CM 1:4, including necessary formwork complete all as specified and directed.
14
-
-
M&L for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all specified and directed.
90
-
-
Taking down carefully existing old burn out/unserviceable copper/aluminium point wiring any type (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing old materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
164
-
-
M&L for point wiring with PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all connected fittings accessories including providing of modular type/size of pressed steel terminal sunken boxes 1.2 mm thick or PVC flush type box and dully fixed it concealed on wall or surface on wall and providing alongwith modular type back and face top covered plate for housing / mounting of switches sockets, regulators etc and also using /drawing of 1.5 sqmm PVC insulated FRLS wire, 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as a continuous earth wire which is connected with terminated the box to ceiling rose / fitting complete and including making good to all disturbed surfaces of wall/ceiling and floor area of wiring system and to match the existing surface of wall/ floor/ ceiling etc. all as specified and directed for following:-
-
-
-
One light/fan point controlled by one way switch 5 Amp
110
-
-
One 3/5 pin socket outlet, 5 Amps on same board
12
-
-
One 3/5 pin socket outlet, 5 Amps on independent board
28
-
-
All as per Sl item No.68 above but using single runs of PVC insulated FRLS wire, 1100volt grade with multistranded copper conductor wire of size 2.5 Sqmm (Nominal area) power point wiring system with controlled by one way switch fixed on independent board and also providing of 2.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as continuous earth wire complete all as specified and directed
12
-
-
All as per Sl item No.68 above but using single runs of PVC insulated FRLS wire, 1100volt grade with multistranded copper conductor wire of size 4.0Sqmm (Nominal area) power point wiring system with controlled by one way switch fixed on independent board and also providing of 4.0sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as continuous earth wire complete all as specified and directed
2
-
-
S&F modular type switch 5/6 Amps 220 Volts for one way switching system complete as specified and directed.
74
-
-
S&F modular type socket 5/6 Amps 220 Volts, 3/5 pin complete as specified and directed.
12
-
-
S&F modular type switch 15/16 Amps 220 Volts for one way switching system complete as specified and directed.
4
-
-
S&F modular type socket 15/16 Amps 220 Volts, 5/6 pin complete as specified and directed.
4
-
-
S&F switch piano flush type 5/6 Amps single pole, one way complete as specified and directed.
76
-
-
S&F socket outlet two in one 5/6 Amps 220 Volts, 3/5 pin multi pin type complete as specified and directed.
28
-
-
S&F switch piano flush type 15/16 Amps single pole, one way complete as specified and directed.
8
-
-
S&F socket outlet two in one 15/16 Amps 220 Volts, 5/6 pin multi pin type complete as specified and directed.
8
-
-
S&F ceiling rose three terminals type made out of polycarbonate, isolated body complete all as specified and directed.
68
-
-
S & F angular/batten type shape lamp holder with PVC/ Polycarbonate insulated body, alongwith brass adaptor and back plate for housing of bulb complete all as specified and directed .
12
-
-
S&F fan regulator modular type electronic with hum free step type alongwith speed control know of capacity 120 watt 230 Volts, complete all as specified and as directed.
8
-
-
S&F step type electronic fan regulator flush type having hum free step alongwith speed control know suitable for single phase, complete all as specified and as directed.
8
-
-
S & F in replacement LED tube light fitting 1 x 20W/ 22W, 220V AC decorative box type with electronic driver, holder including LED tube light with having energy efficient including providing of suitable type of flat flexible cable for electric connection complete all as specified and directed.
30
-
-
S&F in replacement energy saving long life recessed / ceiling concealed mounted flat unique square slim panel integrated design LED luminaire light panel type fitting of size 600mm x 600mm of rating capacity 35W/36W, 220 volt AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling use and required in both warm/white type colour complete set including providing of suitable type flat flexible two/three core cable for electric connection complete all as specified and as directed.
16
-
-
S&F surface mounted LED bulk head luminaries light fitting of rated capacity 10W including LED lamp & driver, out door type with dust and water proof, energy efficient for ready to use and required in both warm/white type colour fixture complete including dully fixed on bldg wall surface including providing of suitable type of flat flexible two/three core cable and making electric connection and including taking down of old fitting all as specified and directed.
4
-
-
S & F sheet metal enclosure duly powder coated with double pole and neutral enclosure with having a two pin and earth plug socket base & metal plug top and having mounting channel and complete with one MCB SPN 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface all as required at site complete all as specified and directed.
2
-
-
S&F in replacement sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangement system suitable of rating of size/type of distribution board SPN 12 way type 220 volt AC supply system with IP protection rating and having mounting channel with having suitable rating of bus bar and suitable size of common neutral and earth link for holding MCBs incomer and outgoing complete set dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface and making all necessary electrical connection complete all as specified and directed.
3
-
-
All as per item No.87 above but of rating of size/type of distribution board SPN 8 way complete all as specified and directed.
2
-
-
S&F in replacement MCB SPN 40 to 63 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
5
-
-
S&F in replacement MCB SP 6 to 32 Amps, 240 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
42
-
-
M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 2x6Sqmm and one run of 1x6 Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall and making electrical connection including taking down old submain wiring complete all as specified and as directed. Note:- 3 runs of 6sqmm wire and one run of PVC casing capping/conduit shall be measured and 1.0 RM.
10
-
-
Supply, laying and fixing of 1100 volts grade heavy duty twin core cable PVC insulated weather proof aluminium multistranded conductor and over all PVC sheathed, 16Sqmm twin core flat or circular including suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire using upto service bracket including taking down old unserviceable cable and connection complete all as specified and directed.
150
-
-
S&F ventilating exhaust fan made out of sturdy engineering plastic body complete with louvers and shutter operational of size 250mm sweep suitable to work on 230 Volts 50 Hz, 1200 RPM including making of suitable type /size of hole on wall and fixing compete with nut, bolt etc all as specified and directed.
18
-
-
S&F ceiling fan 1200mm sweep min air delivery 210CFM with BEE norms 5 star rating of single phase 220 volt AC alongwith blade and down rod and MS fan hook duly fixed in roof area alongwith flat flexible copper wire for all electrical connection complete all as specified and directed.
16
-
-
S&F in replacement LED mirror light fitting with high output diffuser 2' long 1 x 10W, 220V AC decorative type with electronic driver, holder including LED lamp with having energy efficient including providing of suitable type of flat flexible cable for electric connection complete all as specified and directed.
2
-
-
S & F surface wall mounted decorative bracket light fitting with having stainless steel rust free fixture with white glass diffuser alongwith bulb holder based adaptor suitable for 7.5/9W LED filament lamp E-27 base including providing of 1Nx9W LED lamp use in both warm/white type colour complete set and including providing of suitable type of flat flexible two/three core cable and making electric connection all as specified and directed.
5
-
-
S & F environmental friendly LED street light fitting of rated capacity 35W 230 volt AC with having LED driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, out door type, having IP 65/66 protection made out of high pressure die cast hosing with heat resistant glass complete light fitting set including providing of suitable dia or as recommended by manufacturer GI pipe light grade bracket and it to match/setting the new fitting fixture hole attachment system of suitable bracket length make to shape / bend including duly fixed alongwith existing pole /bldg wall/ roof with the help of 02 Nos of MS fixing clamp alongwith nut bolt and including providing of suitable type of flat flexible two/three core cable and making electric connection and including taking down of old fitting all as specified and directed.
2
-
-
S&F rigid non metallic PVC conduit of 15/20mm bore heavy duty with fittings laid in trenches/ fixed to wall with providing clamping arrangement for holding of pipe on wall in proper size of clamps, nut, bolt and washer complete all as specified and directed.
12
-
-
Dismantling of old bracket any type after refixing and laying of house service bracket with hook type complete made of GI pipe 40mm dia medium grade 3m long with 2 nos of 90 degree bends, MS hook and dully fixed on wall/roof with the help of 02 Nos of MS clamp with nut, bolt etc and making all necessary connection complete all as specified and directed.
1
-
-
M&L for earthing, complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI light grade pipe 20 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electrical plate No 03 of SSR-2009 Part-I and connecting to earth test point complete all as specified and directed.
2
-
-