Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date1 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682122_1Tender No
GE (AF) AWA-44/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
INCOMING:-
(a) MCCB 200 Amps,36 kA rupturing capacity, Ics=100%Icu ,4 pole, 415 volts, 50 Hz, Adjustable thermal Fixed magnetic release type - 01 No.
(b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No
(c) Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No
(d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:-
(a) MCCB 63 Amps, 25 kA rupturing capacity, Ics=100%Icu 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type,connected through solid busbar of suitable size in both incoming & outgoing side - 06 No.
-
-
-
Supply, installation, testing & commisioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable size, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 630 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space front ground level. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note:- The rate of PCC on which panel is grouted is deemed to be in quoted rate by the contractor.
1
-
-
INCOMING:-
(a) MCCB 350 Amps,45/50 kA rupturing capacity, 4 pole, 415 volts, 50 Hz, Adjustable thermal Fixed magnetic release type Ics=100%Icu- 01 No.
(b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No
(c) Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No
(d) Indicating lamp (LED type) RYB - 01 Set of three
OUTGOING:-
(a) MCCB 100 Amps, 25 kA rupturing capacity Ics=100%Icu, 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type,connected through solid busbar of suitable size in both incoming & outgoing side - 05 No.
-
-
-
Supply, installation, testing & commisioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable size, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 800 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space front ground level. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note:- The rate of PCC on which panel is grouted is deemed to be in quoted rate by the contractor.
2
-
-
INCOMING:-
(a) ACB 630 Amps 50 kA 4 pole electrically draw out type-01 Nos
(b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No
(c) Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No
(d) Indicating lamp (LED type) RYB - 01 Set of three
OUTGOING:-
(a) MCCB 250 Amps, 35 kA rupturing capacity Ics=100%Icu, 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type,connected through solid busbar of suitable size in both incoming & outgoing side - 01 No. (b) MCCB 200 Amps, 35 kA rupturing capacity Ics=100%Icu, 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type,connected through solid busbar of suitable size in both incoming & outgoing side - 06 No.
-
-
-
S&F in replacement of MCCB 4 Pole, 415 vots AC, 50 Hz 630 Amps, 50 KA with micro processor based release Ics=100%Icu setting complete including thimbling carrying out modification in existing panel to fixed MCCB, complete all as specified and directed.
1
-
-
S&F in replacement of MCCB 4 Pole, 415 vots AC, 50 Hz 400 Amps, 36 KA with micro processor based release Ics=100%Icu setting complete including thimbling carrying out modification in existing panel to fixed MCCB, complete all as specified and directed.
3
-
-
S&F in replacement of MCCB 4 Pole, 415 vots AC, 50 Hz 250 Amps, 36 KA with micro processor based release Ics=100%Icu setting complete including thimbling carrying out modification in existing panel to fixed MCCB, complete all as specified and directed.
3
-
-
S&F in replacement of MCCB 4 Pole, 415 vots AC, 50 Hz 200 Amps, 25 KA with adjustable thermal magnetic release Ics=100%Icu setting complete including thimbling carrying out modification in existing panel to fixed MCCB, complete all as specified and directed.
5
-
-
M&L for disconnecting of old un insulated cable of any size from exixting panel from all the MCCB's (incoming/ outgoing) and refixing the cable after cutting the un insulated part inculding thimbling of cable properly by crimpling tool and welding of old/broken LT panel door with LT panel including hinges and all other connected accessories including scrapping of old LT panel and painting of complete panel as required at site, complete all specified and directed. Note:- Rate of thimble is deemed to be in quoted rate by the contractor.
6
-
-
Dismantling unsv and S&F RYB phase indicating LED lamp on existing LT panel including wiring where required, complete all as specified and directed.
3
-
-
Dismantling unsv and S&F analog Voltmeter (0-500) V on existing LT panel including wiring where required, complete all as specified and directed.
3
-
-
Dismantling unsv and S&F RYB analog Ammeter (0-400) Amps on existing LT panel including wiring where required, complete all as specified and directed.
2
-
-
Dismantling unsv and S&F voltage/ammeter selector switch on existing LT panel, complete all as specified and directed.
4
-
-
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and directed.
5
-
-
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of new/serviceable cables or for fault finding in existing cable and getting out soil in any type of soil, complete all as specified and directed.
902
-
-
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
529
-
-
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil, complete all as specified and directed.
373
-
-
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable, complete all as specified and directed. Note:- Punned thickness of sand shall be measured & paid.
271
-
-
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick, complete all as specified and directed.
30060
-
-
Taking out old underground serviceable/unserviceable cable of any type and size and keeping aside for the purpose of rerouting/relaying in new location/for requisite replacement/further disposal complete including taking out bricks, complete all as specified and directed.
(Note: Earth work shall be measured & paid separately).
3340
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 300 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
40
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 185 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
200
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 150 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
200
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 95 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
900
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 50 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
1000
-
-
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 3.5 core including making electrical connection, complete all as specified and directed.
1000
-
-
Material and labour for straight through joints suitable for armoured XLPE cable 1.1 KV rating heat shrinkable type complete with jointing accessories including cutting of faulty cable of size 50 sqmm to 95 sqmm, 3.5 core, complete all as specified and directed.
2
-
-
All as per Srl item No. 27 above but 120 sqmm to 185 sqmm, 3.5 core, complete all as specified and directed.
3
-
-
Material and labour for straight through joints suitable for armoured XLPE cable 11 KV 120 sqmm to 185 sqmm rating heat shrinkable type complete with jointing accessories including cutting of faulty cable of any size, complete all as specified and directed.
4
-
-
Material and labour for end joints suitable for armoured XLPE cable 11 KV 120 sqmm to 185 sqmm rating heat shrinkable type complete with jointing accessories including cutting of faulty cable of any size, complete all as specified and directed.
4
-
-
Dismantling air break gang operated switch vertical/horizontal mounted including insulators and operating mechanism for replacement and removal from site, complete all as specified and directed.
5
-
-
S&F air break, gang operated switches, 11KV, triple pole, vertically mounted type, mechanically operated, mounted on mild steel channel with operating mechanism, worked from ground level, for current rating upto 630 Amps with drop out fuse element of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles, making neccesary electric connections and testing, complete all as specified and directed.
5
-
-
Supply & fix in replacement automatic Transfer switch 100 A, 4 Pole in sheet metal enclosure 3Phase 415 V, 50 Hz supply with complete protection suitable for automatic/manual operation complete with all mounting arrangement, complete all as specified and directed. Make:-Havells IHYFCDE100, ABB, Schneider, L&T
4
-
-
M&L for replacement of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 630 Amps, complete all as specified and as directed.
1
-
-
Note :- An amount of Rs. 1,16,260.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%