Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date24 Jun 2024
Closing Date17 Sep 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair/Maintenance of LT OH line, LT UG Cable, AB Cable, Feeder pillar and ACB at Janglote Stn under GE Basoli
Repair/Maintenance of LT OH line, LT UG Cable, AB Cable, Feeder pillar and ACB at Janglote Stn under GE Basoli
Repair/Maintenance of LT OH line, LT UG Cable, AB Cable, Feeder pillar and ACB at Janglote Stn under GE Basoli
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)

230

-

-

... More
Material and labour for well burnt, old size Sub Class 'B' brick for covering protection to the eletric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.

7.5

-

-

... More
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and directed.

238

-

-

... More
M&L for PCC (1 : 3 : 6 ) type C-2 using 40mm graded crushed stone aggregate for foundation of poles and stay assembly.complete all as specified and directed.

5.5

-

-

... More
M&L for PCC (1 : 4 : 8 ) type D-2 using 40mm graded crushed stone aggregate for foundation of poles and stay assembly complete all as specified and directed.

13

-

-

... More
Restretching of existing loose OH,LT ACSR conductor wire including GI wire along the span of poles for sagging within the permissible limit,(five/four/two wireline), including binding/rebinding/joining with aluminium winding wire in case of breakage of conductor, size of winding wire shall not be less than 2 sqmm complete all as specified and directed. Note : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during the stretching.

2000

-

-

... More
S&F structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and directed.

3.5

-

-

... More
S & F shackle type,vitreous Insulator including one galvanised mild steel spindle, two galvanised iron washerrs,and one galvanised iron nut, 100 mm height, 115 mm dia, suitable for 1100 Volt,and complete all as specified and directed.

110

-

-

... More
S & F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded with nuts, including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly complete all as specified and directed. (Note: Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).

16

-

-

... More
S & F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and directed.

0.2

-

-

... More
S & F loop type insulator with complete fiting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm complete all as specified and directed.

6

-

-

... More
M&L for earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick burried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanised Iron earth lead 32x6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling and removal of surplas soil to distance not exceeding 50 mtr plate No 3 of SSR 2009 Part-I and connecting to feeder pillars and Transformer all as specified including testing on completion complete all as specified and directed.

14

-

-

... More
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 120 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .

400

-

-

... More
All as per item above but 95 Sq mm X 3.5 core complete all as specified and directed

400

-

-

... More
All as per item above but 70 Sq mm X 3.5 core complete all as specified and directed

400

-

-

... More
All as per item above but 50 Sq mm X 3.5 core complete all as specified and directed

550

-

-

... More
All as per item above but 35 Sq mm X 3.5 core complete all as specified and directed

430

-

-

... More
All as per item above but 25 Sq mm X 4 core complete all as specified and directed

500

-

-

... More
All as per item above but16 Sq mm X 4 core complete all as specified and directed

650

-

-

... More
All as per item above but16 Sq mm X 2 core complete all as specified and directed

550

-

-

... More
All as per item above but10 Sq mm X 4 core complete all as specified and directed

515

-

-

... More
All as per item above but10 Sq mm X 2 core complete all as specified and directed

600

-

-

... More
Taking out the old unsv cable for repair in trenches or passing through pipe/fixed to pole/ wall XLPE insualted 120/95 Sqmm X 3.5 core armourned heavy duty electric cable and depositing in the MES store yard complete all as specified and directed.

800

-

-

... More
All as per item above but 70/50/35 Sqmm X 3.5 core complete all as specified and directed

1380

-

-

... More
All as per item above but 25/16/10 Sqmm X 3.5/4/2 core core complete all as specified and directed

2815

-

-

... More
S & F in repairs cable straight through joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 50 sqmm to 300 sq mm complete all as specified and directed.

12

-

-

... More
S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.

1400

-

-

... More
S&F DWC high density polyethelene pipes in replacement having outer dia 90/76 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.

350

-

-

... More
Supply, installing, testing and commissioning factory made and tested LT Panel out door type, platform mounted suitable for 3 phase 4 wire, 50 Hz, AC supply system base bus bar chamber with insulated busbar 200 amps (3 Nos) phase and 100 amps for neutral rating installed on porcelain insulator. The panel shall be dust and vermin proof IP-65 class protection and made out of 3.15 mm thick CRCA MS sheet and 40 mm x 40 mm x 6 mm thick angle iron frame works, powder coated finish over one coat of red oxide primer outside two coats of red oxide primer inside, front opening type with approns for cable ending with double door shutter and locking arrangement (Including provn of 65 mm Godrej (freedom) lock with 2 keys, insulated copper conductor FRLS IS-699 marked 1100 volt grade but seathed cable adequate size but not less than 4 mm size including necessay civil work complete all as specified and directed. (a) MCCB 160 Amps, 4 Pole, 415 Volts 36 KA Ics=100% Icu including all arrarngments. (Incoming) (b) MCCB 63 Amps TP 25 KA 415 Volts 25 KA Ics=100% Icu -4 Nos (Outgoing) (c) RYB LED Indicator lamp- 03 Nos (d) Digital Volt meter with selector switch 0-500 Volts - 01 No Note :- (i) MCCB,s shall be fixed in independent cabin in horizontal position,Main bus bar in step way, the depth of the panel shall not be less than 350mm ,All the rates deemed to be included in the cost of the job. No extra cost shall be paid. Before placing the order Drg's shall be approved by the GE and shall be kept in record. (ii) Necessary PCC work of foundation/plateform of panel is included in this item and foundation should be 60 CM above the GL

1

-

-

... More
Supply, erecting and fixing in position, steel tubular swaged and welded poles of type 410 SP-31, 9 mtr long, IS-2713 marked, with mild steel base plate (fillet welded to poles), bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 05 Nos band/strip with fluorescent, PO box red synthetic enamel paint and alternate white strip (30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles complete all as specified and directed. Note : (i) Excavation, earth work and PCC will be measured and paid for separetely under respective items of Schedule 'A'. (ii) Poles shall be swaged and welded at manufacturer's factory and not at site. The inner surface shall be factory painted. complete all as specified and directed

14

-

-

... More
S&F aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps , jumpers etc complete of any size as per site requirement complete all as specified and directed.

4.5

-

-

... More
S&F galvanised steel wire 3.15 or 4mm dia , cradle guards, hexagonal/rectangular fabricated of galvanised steel wire 3.15mm dia including binding wire aluminium complete cradle guard complete all as specified and directed.

1.3

-

-

... More
Material and labour for painting of LT Steel/PCC poles with one coat of red oxide and two coat aluminium pait complete all as specified and directed.

300

-

-

... More
Material and labour for painting of LT Steel/PCC poles with yellow and black paint marking and numbering of poles complete all as specified and directed.

200

-

-

... More
Dismantling Old UNSV ACSR Condctor complete all as specified and directed.

4.5

-

-

... More
Dismantling old UNSV PCC/steel pole 9 metre long complete all as specified and directed.

14

-

-

... More
Dismantling of steel work (brackets, clamps, channels including disc and pin insulators, nut & bolts) from existing HT pole complete all as specified and directed

3.5

-

-

... More
Dismantling insulators any type, any size complete all as specified and directed.

6

-

-

... More
Dismantling of earth wire/ stay wire complete all as specified and directed

0.2

-

-

... More
Trimming /cutting tree branches with clearing space upto 2 metre from the over head conductor system all around for LT distribution system and as directed. Note : (i) contractor shall take electric shutdown befor start work from main station and start line after triming of tree and informed to the JE/Engineer-In-Charge. (ii) Tool for trimming of tree braches is provide by conctractor.

300

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply anf fix new MCCB triple pole with neutral, 250 Amp, 35 kA breaking capacity suitable for 415 Volts, 50HZ, 3 phase supply fixed in existing panel and connecting with existing cable including nuts,bolts, washers etc complete all as specified and directed.

1

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply anf fix new MCCB triple pole with neutral, 200 Amp, 35 KA breaking capacity suitable forv 415 Volts, 50HZ, 3 phase supply fixed in existing panel and connecting with existing cable including nuts,bolts, washers etc complete all as specified and directed.

1

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply anf fix new MCCB triple pole with neutral, 100 Amp, 25 kA breaking capacity suitable forv 415 Volts, 50HZ, 3 phase supply fixed in existing panel and connecting with existing cable including nuts,bolts, washers etc complete all as specified and directed.

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply anf fix new MCCB triple pole with neutral, 63 Amp, 25 kA breaking capacity suitable forv 415 Volts, 50HZ, 3 phase supply fixed in existing panel and connecting with existing cable including nuts,bolts, washers etc complete all as specified and directed.

3

-

-

... More
Material and Labour for fixing spacer three way to maintain the space between the conductor, including taking out the old existing spacer from the existing conductor complete all as specified and directed.

46

-

-

... More
Material and Labour for fixing spacer five way to maintain the space between the conductor, including taking out the old existing spacer from the existing conductor complete all as specified and directed.

10

-

-

... More
Material and Labour for cleaning of vegitation around (upto 5 metre from corner/edge) the LT Panel and welding of hinges and locking arrangement complete all as specified and directed.

32

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.