Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Oct 2024
Closing Soon19 Nov 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Maintenance Of 33 Kv And 11 Kv Ht Network Under Ge 864 Ews, Job No Tpp 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673131_2Tender No
CWEK-37/864 EWS/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
44
-
-
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
24
-
-
Supply and laying Unreinforced precast concrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX40mm (for 11KV HT cable) all as specified and directed by Engr-in-Chrage.
1445
-
-
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1with peak, size 450mm x 230mm x 50mm (for 33 KV HT cable) all as specified and directed by Engr-in-Chrage.
435
-
-
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata and relaxing taken out cable complete all as specified and directed.
1
-
-
M&L PCC (1:2:4) type C-1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary steel form work and finishing the surfaces fair in forms complete all as specified and directed.
0.15
-
-
Supply and fixing in renewal of u/s insulator post type insulator 254 mm height, 210 mm dia for 33000 volts grade. including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised iron nut straps etc including taking down old one complete all as specified and directed by Engineer-in-Charge.
5
-
-
S & F in renewal of u/s disc type, insulator three in series, polymer composite insulator, vitreous, 145mm height and 255mm dia ball and socket type, white brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts with GI nut, bdfs straps etc including taking down old one complete all as specified and as directed.
5
-
-
M&L in renewal of old unserviceable pin type, polymer composite insulator, vitreous, white,brown or green insulator includingone galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 50mm height, 150mm dia for11000 volts grade complete all as specified and directed
5
-
-
M&L in renewal of Cross arms, bracings, supports,clamps and back plates fabricatedfrom structural steel sectionsincluding nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shapeor size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of alumium paint, all as specified.
5.5
-
-
Supply and fix air break gang orerated switches for outdoor uses vertical/horizontal mounted including 12 insulators and operating mechanism for repair/renewal of broken /worn out components and insulators etc for current rating upto 200 Amps 11000 Volts complete all as specified and as directed.
2
-
-
Supply and fix air break gang orerated switches horizontal mounted including 12 insulators and oeprating mechanism for repair/renewal of broken /worn out components and insulators etc for current rating upto 800 Amps horizontal type isolator with copper tube 25 mm dia 3mm thick for switch connector for 33000 volts complete all as specified and directed.
2
-
-
Supply & fixing lightening arrestor for outdoor use, expulsion type complete with all fittings, transmission class, discharge capacity 11 kilo volts 65KA complete all as specified and directed
2
-
-
Supply & fixing lightning arrestor for outdoor use, expulsion type complete with all fittings, transmission class, discharge capacity 33 kilo volts 65KA complete all as specified and directed
2
-
-
Supply and fixing in renewal of old unserviceable steel tubular swaged poles type 410 SP-55, 11.00 meter long, complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/straps with white and black colour (30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black bitumenous synthetic enamel paint in 2.5 cm height including tarring one coat on steel surface embedded in concerete foundation complete all as per specified and directed
2
-
-
Supplying, laying or fixing, jointing and testing in renewal of u/s HT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi stranded, heavy duty, 11000 Volts grade (earthed), cross sectional area 95 sqmm 3 core, laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc.complete all as specified and directed of following sizes :- Note :- (a) Excavation , returning filling, sand cushioning and cable cover for the above work will be measured and paid seperately.
(b) Taking out of the old unserviceable cable is included in the quoted rates.
150
-
-
- Ditto - all as per Item No 19 but 120 sqmm 3 core cable complete all as specified and as directed.
110
-
-
Supply, laying, jointing, testing and commissioning in renewal of old unservicebale HT cable with new High Tension (HT) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty, earthed electric power cable, cross sectional area 300 Sqmm 3.0 core aluminum conductor 33000 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through roads etc, complete all as specified and as directed. Note :- (a) Excavation , returning filling, sand cushioning and cable cover for the above work will be measured and paid seperately.
(b) Taking out of the old unserviceable cable is included in the quoted rates.
100
-
-
M&L for detecting the fault in 33 KV underground cable of 300 sqmm with the help of cable fault detector and taking up or down defective/faulty HT underground cable 33000 volts 300 sqmm 3.0 core from the existing trench/duct/pole etc and re-laying the same in the trenches/duct/pole etc after rectification of defects , including meggering of cable, provn of cable lugs, glands, thimble, insulation tape and connecting up with existing control gears, panels etc as per site requirement, complete all as specified and as directed. Note:- (a) Excavation, returning filling etc shall be measured and paid seperately.
(b) Cable end termination joints/straight through joints required for the same will be paid separately. (c) All the tools required for the same is included in the quoted rates.
4
-
-
Supply, jointing, commissioning and testing cable end jointing kit, outdoor type, suitable for 11KV 'E' grade ABC XLPE cable of size 95 sqmm 3 core and 1 bare messanger 95 Sqmm including jointing material complete all as specified and directed.
2
-
-
Supply, laying, jointing, commissioning in renewal 11000 volts (earthed) grade Aerial Bunched Cable with 3 (three) power Cores Stranded, compacted Circular Aluminium Conductor 95 Sqmm screened with Black extruded semi-conducting Compound, natural colored XLPE insulated core screened with Black extruded semi-conducting compound and one layer of copper tape and covered with Black extruded PVC (Core identification by ridges one, two and three over PVC covering) and one bare Messanger wire 95 Sqmm ( combination of glavanized steel wire and Al. Alloy wires), complete all as specified and directed.
Note:- Quoted Rates shall be deemed to include cost of MS clamps required for fixing of cable on HT pole.
100
-
-
Supplying, fixing, jointing and testing & renewal of u/s heat shrinkable cable end termination joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size (50 to 95) sqmm , 3 core, complete all as specified and directed.
2
-
-
Supplying, fixing, jointing and testing & renewal of u/s Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size (120 to 185) sqmm , 3 core , complete all as specified and directed.
1
-
-
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in renewal of u/s straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
2
-
-
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in renewal of u/s straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 Sqmm to 185 Sqmm complete all as specified and directed.
2
-
-
M&L for fixing in repair outdoor termination heat shinkable type jointing kit for 33 KV (Earthed) grade cable complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm, all as specified.
2
-
-
M&L for fixing in repair outdoor Straight through heat shinkable type jointing kit for 33 KV (Earthed) grade cable complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm, all as specified.
2
-
-
S&F in renewal of u/s tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps/ bolts / nuts/ washers or laid in floors/under roads 150 mm bore complete all as specified and directed.
20
-
-
-Ditto- all as per Item No 31 here-in-before but 80mm bore complete all as specified and as directed.
20
-
-
-Ditto- all as per Item No 31 here-in-before but 50mm bore complete all as specified and as directed.
20
-
-
S&F in renewal for power tansformer 6.3 MVA(OLTC), AC 3 phase, outdoor type for following items complete all as specified and directed. Make: Alstom/ABB HT VCB's
-
-
-
(a) Epoxy Arm - 01NO
1
-
-
(b) Transit resistance coil - 03Nos
1
-
-
(c) Main moving contact - 03Nos
1
-
-
(d) Arc/resistance contact - 03Nos
1
-
-
(e) OLTC Auxiliary PVC insulated armoured copper cable 4 core 25 sqmm 1100 volt
30
-
-
(f) Topping up of power transformer oil having BDV value not less than 60
100
-
-
Material & labour dehydration/cleaning sprarked/old transformer oil and all other foreign materials from external surface of power transformer of capacity 6.3 MVA and preparing the surface to paint the transformer body one coat of synthetic enamel while paint, including writing MES No & SM No with smooth grey paint on back base complete all as directed by Engineer –in-Charge including renewal of outlived silica gel with new silica gel ‘A’ grade with breather assembly of existing size complete for power transformer of capacity 6.3 MVA, all as specified.
Note: Transformer oil filteration & dehyration by Ultra High Vaccum double stage machine will be done on existing installation place on same days and report of the same be obtained from the vendor).
5000
-
-
S&F in renewal of over current and earth fault relay suitable for CT ratio 5/150 Amp for 33 KV VCB's panel, complete all as specified and directed
4
-
-
M & L for renewal of damaged copper bus bars having length 5-6 mtr,25 mm dai complete all as specified and as directed
3
-
-
S & F in renewal of heat shrink insulation tubes for all the bus bars and maintaining the RYB sequence in the system complete all as specified and as directed
80
-
-
M & L for calibration and programming of all 11 KV, PF, AMP and multifunction meters on different settings and as per the CTR Ratios complete all as specified and dirceted
50
-
-
M&L for testing complete with testing kit for HT VCB / Panel 33 KV indoor/ outdoor complete with calibration of all protective devices & over hauling of all mechanical parts of VCBs comprising (6 Nos out door type and 3Nos indoor type VCB and OLTC-03 Nos for 33 KV ) all as directed.
10
-
-
Maintenance and complete overhauling with callibration of 11 KV, VCB/OCB including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing minor parts reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete all as specified and directed. Note : Spare parts will be measured and paid separately
20
-
-
S&F in renewal for HT VCB 11 KV, AC 3 phase, 50 HZ indoor type for following items complete all as specified and directed.
-
-
-
(a) Control wiring of HT VCB pannel with suitable size of copper wire complete with color code ferruls and tinned copper lugs.
1
-
-
(b) Trip coil 110 volt DC.
2
-
-
(c) Bakelite housing set.
1
-
-
(d) Spout set (set of three) shower and rose contacts.
2
-
-
(e) Auxiliary switch.
2
-
-
(f) Limit switch.
2
-
-
(g) Rotary switch.
2
-
-
(h) Auxiliary Contactor.
2
-
-
(j) Closing Coil 110 volts.
1
-
-
(k) Tripping lever.
2
-
-
(l) Charging lever.
1
-
-
(m) Charging gear for VCB.
2
-
-
(n) Indication lamp 110 volts (R, Y, B).
3
-
-
(o) Tripping pin.
1
-
-
(p) Push Button.
1
-
-
(q) Charging Motar complete 220 Volts.
1
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, including test point complete all as specified and as directed
5
-
-
M & L for Chemical earthing with copper earth plate 90x60cmx5mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to & copper earth strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of copper or brass connected to earthing test point complete all as specified and directed by Engr-in-Charge
4
-
-
S&F CT 33 KV outdoor type single phase oil cooled CT of ration 33 KV DC class 150/5/5, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable CT complete all as specified and directed.
1
-
-
S&F PT 33 KV outdoor type single Phase oil cooled PT of ration 33 KV DC class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable PT complete all as specified and directed.
1
-
-
M & L for renewal of damaged earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation fer loop earthing etc.as required 25x4mm galvanised iron strip complete all as specified and as directed
24
-
-
M&L for topping up of graded course aggregate 20mm to 40 mm of nominal size in base of 2/4 pole (electrical poles) structure and electrical sub stations/Main power house 33 KV Grid etc complete all as speciried and directed.
10
-
-
M&L boring of holes under roads pavements hards standing by trenchless technology using ulta sound technique & necessary machine including HDPE pipe of 6 kg/sqmm of 150 mm dia suitable 0.4 Mpa working pressure all as specified & directed bt E-in-Charge.
12
-
-
M&L for trimming of tree branches touching with 33/11 KV HT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines complete all as specified and directed.
Note :- one span will be counted in between the distance from one pole to another pole and all T&P reqd for the same is included in quoted rates
220
-
-
Demolition of cement concrete in any description and in any position not otherwise specifically provied for complete all as specified and as directed.
7
-
-
M&L for preparation of old painted surface of 33 KV yard channel, angle iron by scrubbing, cleaning and painting with one coat of aluminium paint including writing SM No / MES No of all other items complete all as specified and directed by Engr-in-Charge.
150
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%