Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date21 Jun 2024
Closing Date17 Jul 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_661151_1Bid Award Id
ViewTender No
GE/KC-26/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling of asbestos cement /CGI/PGI (corrugated, semi corrugated,etc.) sheets in roof coverings complete all as specified and directed.
975
-
-
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
600
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed.
34
-
-
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
175
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
667
-
-
Dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed.
13
-
-
Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed.
2
-
-
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
1
-
-
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in padding on roof, for levelling of roof slab, finished even and fair, complete all as specified & directed..
40
-
-
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
4
-
-
M & L for brick work with sub class ‘B’ old size bricks (EXCEPT BRICKS) straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. NOTE: - OLD BRICKS OBTAINED FROM DEMOLITION SHALL BE USED UNDER THIS ITEM.
1
-
-
Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 20 cm in girth complete all as specified and directed.
50
-
-
S & F of mild steel framed work such as gate grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
280
-
-
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe 410 -W(Gde-E- 250) quality-A including cutting, welding etc. complete all as specified and directed.
3100
-
-
S&F for suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 25x25mm, main runner ‘T’ of size 25x38mm, secondary runner ‘T’ of size 25x28mm with 4 mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note :- All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
600
-
-
S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
900
-
-
S & F of Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed .
75
-
-
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
50
-
-
S& F Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls
in the same manner complete all as specified and directed.
75
-
-
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slope of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
110
-
-
M & L for40 mm thick cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as laid in alternate bays finished the surface even and fair without using extra cement complete all as specified and directed.
25
-
-
M & L for 100 mm thick cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in sub base floor complete all as specified and directed.
100
-
-
M & L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
80
-
-
M & L Non - skid joint free ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
560
-
-
M & L Non - skid Ceramic joint free coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
27
-
-
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
100
-
-
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed.
25
-
-
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed. NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items
100
-
-
M & L for 10 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling with cement mortar 1:3 finished even and smooth (without using extra cement)complete all as specified and directed.
50
-
-
Supply only water proofing compound ( (Liquid) complete all as specified.
3
-
-
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
560
-
-
M & L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
107
-
-
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding and fixing of GI wire netting 0.90 mm dia and 12 mm mesh in pathes area n.exc 5.00 Sqmm where ever required and rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:- Integral water proofing compound shall be measured & paid seprately.
10
-
-
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
50
-
-
M & L for preparation of old decorated plastered or unplastered surfaces of ceiling, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of white wash complete all as specified and directed. NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items
20
-
-
M&L for preparation of old decorated plastered or unplastered surfaces of walls, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of cement base paint complete all as specified and directed.
200
-
-
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
100
-
-
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
25
-
-
M & L for surface preparation including final cleaning of the sufrace treating of construction joints, filling of hineycombs and making fillrts (Wattas) 75 mmx 75 mm in a cocave profile with polymer modified mortar ( cement:sand Asian paints Smartcare Professional Multipurpose Polymer having acrylic emulsion chemistry, solid centent %54+1% and specific gravity;1.04) complete all as specified and directed.
15
-
-
Supplying and applying single component , elastomeric, acrylic fibre reinforced water proofing and anticarbonation coating Smart Care Damp Proo Ultra or approved equivalent with minium elongation of 350% tensile strength 2.90 Mpa and shall have crack bridging ability of upto 2.5 mm and shall resist 10 bars of hydrostatic pressure reduces surfaces temp upto 10 degree celsius. The system consists of self priming with 33% dilution followed by two undiluited coats complete all as specified and directed.
250
-
-
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes by using bleaching powder, hoisting if required, reconnecting and re-fixing in position of capacity exc. 250 & n. exc. 500 ltr, making good for running of water from tank to inside of bldgs and writing of date of cleaning and due on by synthetic enamel paint on water tank, complete all as specified & directed.
NOTE :- Cost of bleaching powder shall be deemed included in the quoted rate of this item.
10
-
-
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes by using bleaching powder, hoisting if required, reconnecting and re-fixing in position of capacity exc. 500 & n. exc. 1000 ltr, making good for running of water from tank to inside of bldgs and writing of date of cleaning and due on by synthetic enamel paint on water tank, complete all as specified & directed.
NOTE :- Cost of bleaching powder shall be deemed included in the quoted rate of this item.
2
-
-
Dismantling of precast RCC water tank exc. 250 Litre but not exc.500 Litre capacity complete all as specified and directed.
10
-
-
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
13
-
-
S & F of 1000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
2
-
-
Taking up or down 15 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
10
-
-
Taking up or down 20 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
100
-
-
Fixing only 20 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
20
-
-
S&F 15mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
10
-
-
S&F 20 mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
80
-
-
S&F in repair bib taps, cast copper alloy with crutch or butterfly handle, screwed down, externally threaded having weight @ 0.40 Kg/Each, ISI marked with IS : 781, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
20
-
-
S&F in repair fancy type angular stop cock with flange, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, externally threaded, screwed both ends for iron pipe or for unions of 15mm bore complete all as specified and directed.
2
-
-
S & F in repair 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
15
-
-
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
11
-
-
S & F low density PVC waste pipe 32 mm bore for flushing cistern complete all as specified and directed.
4
-
-
S & F in repair chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union size 125 mm complete all as specified and directed.
2
-
-
S&F in repair 15 mm bore angle stop valve cast copper alloy,CP with capstan heads, fancy type any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.
14
-
-
S & F in repair 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
15
-
-
S & F in repair 15 mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT' or 'COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
2
-
-
S & F in repairs water closet vitreous china squatting pan ‘Orrisa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed.
2
-
-
S & F of vitreous china, wash hand basin, flat back, white of size 580mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed
3
-
-
S & F in repair polymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed.
4
-
-
S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass 4 mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
2
-
-
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall /floor including demolition of old pipe etc. complete all as specified and directed.
155
-
-
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
30
-
-
S & F of 110 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed
6
-
-
S & F of 110 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal complete all as specified and directed
8
-
-
S & F of 110 mm bore PVC (SWR) Slotted vent cowl complete all as specified and directed
8
-
-
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed wall /floor including demolition of old pipe etc complete all as specified and directed.
50
-
-
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
10
-
-
S & F of 75 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed
3
-
-
S & F of 75 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal complete all as specified and directed
3
-
-
S & F of 75 mm bore PVC (SWR) Slotted vent cowl complete all as specified and directed
7
-
-
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :-
(a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces.
(b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed.
(c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat.
(e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying a coat of bitumious based aluminium