Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Apr 2025
Closing Soon28 Apr 2025
Tender Amount₹ 45,15,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,installation,connecting, testing & commissioning Split AC 1.5 Ton capacity cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 5 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.

12

-

-

... More
Supply,installation,connecting, testing & commissioning Window AC 1.5 Ton capacity hot & cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.

4

-

-

... More
Supply and Install automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 5 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minute complete all as specified and Directed by Engr in charge.

39

-

-

... More
S&F Sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing complete all as specified and directed by Engineer-in-charge .

485

-

-

... More
Supply and Install for integration of AC for ambient temperature monitoring with integrated temperature sensor circuit. It should have programmable system for ON/OFF of ACs and if room temperature exceed the set point, the controller should start both ACs till temperature is maintained. voltage range 220V-230V Current 500 mA 12V or better Display Minimum 4 Digit display Sensori Transmitter P1100 RTD stem Type with minimum 5 m wire Conversion Type Sigma Delta Resolution Minimum 18 BIT yes Sample & Hold Cortrol Relay Output Minimum 25A 230V Status Relay Output ALL AC status, Hooter & Fault Fire Trip Yes Communication Yes Weight Not more than 4 Kgs complete all as specified and Directed by Engr in charge.

8

-

-

... More
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 40 amp 240V complete all as specified and directed.

39

-

-

... More
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/Transformer as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

114

-

-

... More
M&L for earthing complete in replacement with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to copper strip 20x3 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ Transformer as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

12

-

-

... More
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25X4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

95

-

-

... More
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ DB box as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

113

-

-

... More
Supply and fixing in aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.

525

-

-

... More
Supply and fix in GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified and directed.

250

-

-

... More
Supply and fix in GI strip of size 32 x 6 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified and directed.

50

-

-

... More
Supply and fixing GI earthing continuty conductor wire of 4mm dia with saddles/ insulators and fixing screws for roof/ down conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ hangar (roof/down conductor)/ pipe/ trench complete all as specified and directed.

200

-

-

... More
M&L for recharging of earthing pits by filling of Water soluble earth soil reactivation earthing compund in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/ poured in earth pit after mixing in water in appropriate quantity.

186

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.