Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date14 Oct 2024
Closing DateCancelled
Tender Amount₹ 14,94,000
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679476_1Bid Award Id
ViewTender No
CWEJP-41/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Roof treatment including removing all the debris and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as specified and as directed.
(a) Applying Ist course of 15 mm thick cement screed in CM 1:4 over concrete surface.
(b) Applying 2nd course of bituminious primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.
(c) Applying 3rd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.
(d) Applying 4th course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, complete all as specified and directed.
15
-
-
Cement concrete M-10 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and as directed.
7.38
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in foundation, including raft, footing, fdn beams, plinth beams bases for columns complete all as specified and as directed.
21.03
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in columns , pillars, piers, posts and struts etc complete all as specified and as directed.
8.19
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5 m spancomplete all as specified and as directed.
4.65
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in salves and like. complete all as specified and as directed.
5.31
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in walls, basement wall of any thickness above top of footings incl attached pilasters & buttresses complete all as specified and as directed.
1.8
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as fins, facias, louvers, parapet and railing exc 60 cm ht, newals, balustrade & the like complete all as specified and as directed.
1.86
-
-
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in stairways,incl steps, string pieces complete but excluding railing complete all as specified and as directed.
3.72
-
-
Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of plinth beams complete all as specified and as directed.
52.32
-
-
Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal fair finished surface of concrete complete all as specified and as directed.
108
-
-
Form work to sides and soffits of floor or roof beams beam , lintels, cantilevers, shelves etc with fair finished complete all as specified and as directed.
38.61
-
-
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with fair finished complete all as specified and as directed.
30
-
-
Form work to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work with fair finished complete all as specified and as directed.
99.21
-
-
Form work to staircase with slopping or stepped soffits incl risers & strings (exc landing) with fair finished complete all as specified and as directed.
25.32
-
-
TMT bars 10 mm dia & over cut to length bent to shape required including cranking bending spirally or hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or seuring with chip with deep quality confirming to FE 500/FE 500D complete all as specified and as directed.
5250
-
-
All as per description Srl item No 18 here-in-before but 6 to 8 mm dia complete all as specified and as directed.
750
-
-
TMT bars 5mm dia and over upto and including 10mm dia as in stirrups and spacers complete all as specified and as directed.
2704.74
-
-
Brick work with old size brick curved or straight on plan exceeding 6m area radius built in cement mortar 1:6 brick crushing strength not less than 75 kg/square cm complete all as specified and as directed.
9.48
-
-
Rendering 10mm thick on other than fair face of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
35.37
-
-
Rendering 15 mm thick on fair face of brick work or concrete surface in cement mortar 1:4 (with water proofing compound, WPC measured & paid seprately) finished even and smooth without using extra cement complete all as specified and as directed.
39.09
-
-
Rendering 5 mm thick on concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
56.79
-
-
Rendering 5 mm thick on concrete surface as in columns, RCC walls, fins etc in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
156.9
-
-
Preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
60.09
-
-
Preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc complete all as specified and as directed.
56.79
-
-
Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of white wash complete all as specified and as directed.
171.27
-
-
Preparation of new or previously untreated surfaces of steel of any description not otherwise described over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and as directed.
11.1
-
-
Sand filling under floors or in foundation incl watering and consolidating complete all as specified and as directed.
1.71
-
-
75 mm thick, PCC M-10 (nominal mix) using 40 mm graded crushed stone aggregate as in sub-base to floor complete all as specified and as directed.
22.92
-
-
30 mm thick, PCC M-15 (nominal mix) using 20 mm graded crushed stone aggregate as in sub-base to floor complete all as specified and as directed.
22.92
-
-
20 mm thick screed bed or bedding layer of mortar in cement mortar 1:4 for laying floor finishes complete all as specified and as directed.
60.24
-
-
10 mm thick screed bed or bedding layer of mortar in cement mortar 1:3 as in vertical surfaces for laying wall finishes complete all as specified and as directed.
10.68
-
-
Brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
37.92
-
-
Machine cut Kota stone slab flooring, 20-25 mm thick over cement screed bed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
18
-
-
All as per description of Srl item No 36 here-in-before but on vertical surfaces such as in riser, skirting etc complete all as specified and as directed.
8.07
-
-
Terrazo tiles 25cm x 25cm x 22 mm thick with size of chips upto 6mm set jointed and pointed in neat cement slurry in floors, cut and polished with grey cement and pigments complete all as specified and as directed.
42.24
-
-
All as per description Srl item No 38 here-in-before but on vertical surfaces such as in riser, skirting etc complete all as specified and as directed.
2.61
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any time of soil complete all as specified and as directed.
77
-
-
Rendering 10 mm thick on fair face of brick work or concrete surface in cement mortar 1:4 (with water proofing compound, WPC measured & paid seprately) finished even and smooth without using extra cement complete all as specified and as directed.
21.06
-
-
Supply only liquid water proofing compound/admixture, ISI marked complete all as specified and as directed.
6.75
-
-
15 mm thick screed bed or bedding layer of mortar in cement mortar 1:4 for laying roof tiles/ finishes complete all as specified and as directed.
21.06
-
-
Cement concrete tiles 25cm x 25cm x 22 mm thick machine pressed set jointed in neat cement slurry as on roof complete all as specified and as directed.
21.06
-
-
MS framed work as in steel doors complete all as specified and as directed.
179
-
-
Point wiring with multi stranded copper conductor of size 1.5 Sqmm PVC FRLS insulated unsheathed cable in and including PVC conduit of size 20MM dia for concealed wiring including 1.50 Sqmm PVC FRLS copper earth wire (green colour) for one light point or fan point or bell point controlled by one, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including cutting chases and making good to disturbed surfaces of wall/floor complete, all as specified and as directed.
12
-
-
All as per ser item No 46 hereinbefore but for one 3 pin socket outlet 5 Amp Same board complete, all as specified and as directed.
3
-
-
All as per ser item No 46 hereinbefore but for one 3 pin socket outlet 5 Amp independent. complete, all as specified and as directed.
3
-
-
All as per Item no 46 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 Sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete, all as specified and as directed.
6
-
-
Replacement of Switch piano flush type single pole, one way 5 Amp , complete, all as specified and as directed.
12
-
-
Replacement of Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete, all as specified and as directed.
6
-
-
Replacement of Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete, all as specified and as directed.
6
-
-
Ceiling rose surface bakelite three terminals 240 voltscomplete, all as specified and as directed.
9
-
-
Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings complete, all as specified and as directed.
3
-
-
LED lamp, 6500K, 900 lumen in white colour of 9 Watt B-22 with poly carbonate difusser and aluminium heat sink, complete, all as specified and as directed..
3
-
-
Electronic fan regulator stepped type with five step 240 volts suitable for 1200/1400 mm sweep AC ceiling fan, complete, all as specified and as directed.
3
-
-
LED light fitting 1x20 watt, 220 volts AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable suitable size from ceiing rose, complete, all as specified and as directed.
3
-
-
Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 4 ways, complete, all as specified and as directed.
3
-
-
MCB SP-06 to 32 Amp, 240 volts complete, all as specified and as directed..
6
-
-
MCB SPN- 32 Amp, 240 volts 50Hz AC supply, complete, all as specified and as directed.
3
-
-
Ceiling fan BEE 5 star (BLDC) rated super energy efficient electric driven ceiling fan with double ball bearing 1200mm (48 inch) sweep,copper wound stator ( with brudhless direct current motor) having three blades made of aluminium alloy suitable for operation on single phase 140-285 Volts, AC ,50Hz , with power factor not less than 0.99,service value minimum 8 Cu.metre / Min/Watt or higher ,air delivery minimum 230 cubic metre per minute or more ,power consumption maximum 28 watts or lower , top speed minimum 350 (+/-) 10% RPM or higher, speed control by 5 step regulator with copper winding complete as per IS:374-1979 or latest IE rule complete, all as specified and as directed.
3
-
-
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and as directed.
3
-
-
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete, all as specified and as directed.
230
-
-
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soil complete, all as specified and as directed.
42
-
-
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and as directed.
70.27
-
-
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete, all as specified and as directed.
15
-
-
Steel pipe glavanized light grade of 40 mm core laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers complete, all as specified and as directed.
12
-
-
Sub class ‘B’bricks for machenical covering to cables laid dry flat ,with width equal to the length of brick complete, all as specified and as directed.
1609
-
-
Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 including GI pipe 40mm, medium grade , 1.7mtr long mounting bracket and providing fixing clamps, bolts, nuts of suitable size, complete, all as specified and as directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements