Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date24 Oct 2024
Closing Date14 Nov 2024
Tender Amount₹ 38,81,000
Costs
EMD
₹ 78,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681102_1Bid Award Id
ViewTender No
GE/S(U)-59/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
28
-
-
Demolition of reinforced cement concrete of any description and in any position etc complete all as specified and as directed.
6
-
-
Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified .
4
-
-
Dismantling floor hearth or wall tiling including cement mortar beddig not backing and removing rubbish off the premises complete all as spd
60
-
-
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified.
6
-
-
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6.complete all as specified and directed.
40
-
-
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
20
-
-
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cementincluding mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed.
Note : Liquid WPC will be measured and paid separately.
1500
-
-
M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing even and smooth without using extra cement complete all as specified and directed..
1060
-
-
M&L for Preparation of new plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed.
1430
-
-
M&L for Preparation of old plastered wall surfaces including complete removal of existing surface and applying two coats of cement base paint complete all as specified and directed.
800
-
-
M&L for Preparation of new plastered wall surfaces and applying two coats of weather proof exterior emulsion paint complete all as specified and directed.
70
-
-
M&L for a 1mm thick layer wall care putty on wall including a coat of primer including preparation etc all as spd and as directed.
300
-
-
M&L Preparation of new plastered wall surfaces and applying two coats of oil bound distemper white or tinted with roller application over a coat of chalk whitening primer complete all as specified and directed.
1000
-
-
M&L Preparation of old plastered wall surfacesincluding complete removal of existing surface and applying two coats of oil bound distemper with roller application complete all as specified and directed.
1000
-
-
Supply only water proofing compound (liquid),ISI marked.
26.73
-
-
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate in foundations filling and mass concrete complete all as specified and directed.
140
-
-
M&L for 100 mm thick Plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor laid in alternate panels complete all as specified and directed.
266
-
-
M&L for cement concrete type D2, 1:4:8 (40mm graded aggregate) as in foundation, filling in sub base and mass concrete complete all as specified and directed.
43
-
-
M&L Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone agg) as Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresse complete all as specified and directed.
2
-
-
M&L Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone agg) as slabs supported on walls/chajjas, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like,all as specified and directed.
4
-
-
Use and waste of form work to soffits of suspended slab such as roof slab , walls/chajjas, beams and column, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete complete all as specified and directed.
45
-
-
Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping ends and binding with and incl mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
2000
-
-
M & L for 25 mm thick plain cement concrete type B-0 1:2:4 (12.50 mm graded aggregate) as infloor and finished even and fair complete all as specified and directed.
405
-
-
M & L for Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 laying floor finishes complete all as specified and directed.
50
-
-
M&L For Non - skid coloured Ceramic tiles 8 to 9 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
20
-
-
M&L for Virified dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
30
-
-
M&L for Glazed coloured ceramic tiles in dado/vertical surface 300x 450x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface complete all as specified and directed.
50
-
-
M&L for coloured Machine vibro mechenically floated glossy finish interlocking cement paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with topping of cement mixed with imported pigment , colour and shape shall be approved .
140
-
-
M&L for Machine cut kota stone slab flooring 18-20mm thick in riser of steps, skirting,dado and polishing laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
10
-
-
M&L for 150mm wide strip of makrana white Marble 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing types complete all as specified and directed.
5
-
-
M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
350
-
-
M & L for Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 laying floor finishes complete all as specified and directed.
355
-
-
M&L for pressed steel frames for doors made out of 1.25mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate ,12mm bar thresh hold etc. complete , of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed.
45
-
-
M&L for pressed steel frames for doors made out of 1.25mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate ,12mm bar thresh hold etc. complete , of frame size 105 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed.
15
-
-
M&L for 35 mm thick factory made, 2nd class hard wood , plain framed, panelled shutters (two or more panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
35
-
-
S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cat and mitred beads for securing glass etc fitted to chowkats for windows, ventilators,etc complete, size of member of shutter as spd in SSR Part -I, Sec 8, clause 8.24 (b).
12
-
-
S&F steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed.
Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
35
-
-
Description all as per item as above here in before but without glazing bar complete all as specified and directed.
Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
35
-
-
S&F factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all specified.
Note :- i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
2.55
-
-
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified and directed.
300
-
-
S&F Welded steel wire fabric mesh weight n.exc 4 kgs per sqm fixed to steel members complete all as specified and directed.
250
-
-
Material and labour for Providing cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregates as in filling of pressed steel door frame all as specified and as directed.
1.5
-
-
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
10
-
-
Supply and fix 4mm thick sheet glass, ordinary quality and glazing with rubber beading around the glass, in squares n exc 0.50 sqm in each pane complete all as specified and as directed.
22
-
-
Supply and fix 4mm thick sheet glass, frosted or grounded on one side with rubber beading around the glass, in squares n exc 0.50 sqm complete all as specified and directed.
2
-
-
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1mm and fixed with tinned tacks, or galvanised wire staple complete all as specified and as directed.
22
-
-
S&F for 250 mm Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
10
-
-
S&F for 150 mm Aluminium anodised,barrel tower bolts of extruded section and fixed complete all as specified and as directed.
36
-
-
S&F for 150 mm Aluminium anodised,handle, cast type anodised complete all as specified and as directed.
36
-
-
Preparation of new wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and as directed by Engr-in-charge/GE.
85
-
-
Preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and directed.
85
-
-
M & L for hardcore of gauge of borken stone or boulders n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
12
-
-
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
90
-
-
M&L for pre painted galvalume aluminium zinc coating GI based corrugated sheets 0.5 mm thick of any colour having tensile strenght of 550/MPA as in roof covering, cladding to wall fixed with self taping screws complete all as specified and directed.
450
-
-
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
50
-
-
M&L for Roof trusses (framed), trussed,purlins, crane gantries, rails,frame works as in door frame and fastenings and heavy bracket framing (Beam,coloum, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
6000
-
-
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed.
169
-
-
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
450
-
-
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
50
-
-
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified.Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
103
-
-
All as per srl item No 64 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly.
35
-
-
All as per srl item No 64 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly.
9
-
-
All as per Srl item No 64 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly.
22
-
-
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed by Engr In charge/GE.
147
-
-
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed by Engr In charge/GE.
22
-
-
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed by Engr In charge/GE.
44
-
-
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed by Engr In charge/GE.
22
-
-
M &L Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Blockcomplete all as specified and directed by Engr In charge/GE.
103
-
-
S & F in replacement sheet metal enclosures for DBs when MCBs to be used double door DB VTPN MCCB 125A 4way IP43 Protection with 125A MCCB 16kA all as specified and directed by Engr In charge/GE.
2
-
-
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
2
-
-
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and directed.
2
-
-
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and directed.
40
-
-
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and directed.
4
-
-
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire(For TPN DB to SPN DB). Make: Gloster/ Finolex/ Polycab.
180
-
-
S&F Sub main wiring with four single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified and directed.
140
-
-
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead all as specified. Including taking down old sub main wire(For street light ).
130
-
-
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost.
2
-
-
S&F electronic step type fan regulator 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and directed.
22
-
-
Taking down ceiling fan of any size after disconnecting the wire from existing ceiling rose and depositeed to MES Store (AGE E/M sub Divn) and Supply & fix ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with burshless direct current motor (BLDC) all as specified & directed by Engr-in-charge/GE.
32
-
-
Taking down exhaust fan of any size after disconnecting the wire from existing ceiling rose and depositeed to MES Store (AGE E/M sub Divn) and Supply & fix exhaust fan, steel body, AC single phase 230/240 volts heavy duty of size 300mm sweep with blades, frame, louvers and all fixing arrangements as all as specified & directed by Engr-in-charge/GE.
11
-
-
Supply and fixing LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
44
-
-
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
14
-
-
Supply and fixing LED building security light fitting 65 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
12
-
-
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , all as specified and directed by Engg- in-Charge/GE.
12
-
-
S&F in replacement of Sheet metal enclouser single pole and neutral with 2 pin and earth plug and socket 20A 240V complete with one double pole MCB capacity 25 Amp, C Curve, 10KA complete all as specified and directed by Engr-in-charge/GE.
4
-
-
Supply & fix onload changeover switch(side handle) capacity 63A, four pole, in sheet enclosure, 415V complete all as specified and directed by Engr-in-Charge. Make : Havells item code No IHBFFE0063 or equivalent make in Indoasian, HPL, Schneider.
2
-
-
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately.
170
-
-
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out all as specified and directed.
39.15
-
-
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed.
25.1
-
-
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
14.05
-
-
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete as specified. Note : for payment purpose punned thickness shall be measured.
11.75
-
-
M&L Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels all as specified and directed.
1160
-
-
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles all as specified and directed.
25
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements