Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date12 Feb 2024
Closing Date6 Mar 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/smb/t-62/2023-24 Repair And Maint To Internal Electrification Works Including Led And Bldg Lights In Certain Bldgs At Zone I Area Mil Stn Samba Under Ge Samba
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_631328_2Bid Award Id
ViewTender No
GE/SMB/T-62/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR AND MAINT TO INTERNAL ELECTRIFICATION WORKS INCLUDING LED AND BLDG LIGHTS IN CERTAIN BLDGS AT ZONEI AREA MIL STN SAMBA UNDER GE SAMBA
BOQ Items
All as per srl item No 2 above but for 3 pin 5 amps on independent board complete all as specified and directed.
400
-
-
All as per srl item No 2 above but for 3 pin 5 amps on same board complete all as specified and directed.
150
-
-
Point wiring for one power point controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked for switches and sockets , including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.
Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
300
-
-
Switch piano flush type one way 5 amps SP complete all as specified and directed.
2050
-
-
Switch Socket combination multipurpose 2 in 1, 3 pin 6 and 16 amps controlled by one switch flush type universal.
300
-
-
Switch Socket combination multipurpose 2 in 1, 3 pin 6 and 6 Amps controlled by one switch flush type universal.
550
-
-
Ceiling rose 65 x 50mm three terminals complete all as specified and directed.
765
-
-
Bell push flush type with indicator 6 Amps complete all as specified and directed.
20
-
-
Ceiling fan regulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specified and directed.
250
-
-
Lamp holder/batton holder/angle holder insulated body(Metal ring) with back bakelite plate suitable for batten fittings, complete all as specified and directed.
100
-
-
Electronic bell ding-dong AC 230 Volts single pole complete all as specified and each directed.
20
-
-
Inverter LED batten with square profile and polycarbonate channelm lithium lon battery with charging time 8 hours to 10 hours and back up time upto 4 hours of capacity 20 watt 230 volt, complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conducter cable with suitable size mounting on rectangular PVC black complete all as specified and directed, Cat part No-LHEXACP7FN1W020 of Havells or equivalant make of crompton/phlips/bajaj/EVEREADY/ASCEN TECH/HPL/BENLO
Note : (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboraory.
(ii) Contractor shall give gurantee of complete fitting/fixtures for minimum of 2 years form the date of completion. (iii) Contractor shall conduct the inspection of company representative at site befor installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70% material at site for approval of GE before incorporation in the work.
500
-
-
LED Tube light 20 Watt LUMILINE Basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver. including taking down old u/s tubelights with fittings, complete all as sepcified as directed.
720
-
-
LED Bulk head Sirius Series 10 watt LED light, Make - Wipro Cat Part No. DA11027 or technocommerically equivalent make of Havells/Bajaj/Syska/EVEREADY/ASCEN TECH/BENLO/HPL.
30
-
-
Sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 16 KA=01 NO (for incoming )
(b) MCB SP 63 amps = 4 Nos (for outgoings) . Note :- (i)The DB shall be VTPN series of Make : Schneider ,cat part no: A9HVD04L or equivalent make of L&T/ ABB/ Legrand/BENLO . (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.
(iii)connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped.
(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost .
30
-
-
Sheet metal enclousre for TPN DBs 4 way when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts three pahse and neuton 4 way complete all as specified and directed.
10
-
-
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways complete all as specified and directed.
15
-
-
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed.
20
-
-
MCB TPN 63 amps 240 Volt 'B' series complete all as specified and as directed.
12
-
-
MCB SPN 63 amps 240 Volt 'B' series complete all as specified and as directed.
30
-
-
MCB SPN 6 to 32 amps 240 Volt 'C' series complete all as specified and as directed.
20
-
-
MCB SP 6 to 32 amps 240 Volt 'B' series complete all as specified and as directed.
250
-
-
Submain wiring in and including PVC conduit 1.8 mm thick ,25 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 4 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 4 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
600
-
-
Submain wiring in and including PVC conduit 1.8 mm thick ,25 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
700
-
-
Submain wiring in and including PVC conduit 1.8 mm thick ,32 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 10 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc including taking down old U/S brunt sub main wiring from wooden battens, complete all as specified and directed. (Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
250
-
-
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of nuts bolts,washers of GI upto test point,GI tubing light grade 15mm bore protection pipe and GI watering pipe 20mm light grade with funnel and wire mesh ,charcoal and salt,40mm thick pre-cast RCC M-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and removing surplus soil to a distance n.exc.50m) and connecting, Testing on complition, Complete all as specified and shown on Electrical Plate No 3 of SSR-2009 Part-1. complete all as specified and directed.
Notes:- 1. Earth lead & protection pipes length upto & including 7.50 mtr is included in the quoted rate.
2. Soil should be free from stone, boulders, aggregate, gravels etc.
20
-
-
Recess mounting LED 2X2 luminaire light fitting 36 watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sq mm with suitable size of 36 watt complete as specified and directed at site. make : Cat part No :-STARTO2X2PLR36WLED840MOD of Havells or technocommerically equivalent make of philips/crompton/BENLO /EVEREADY/ASCEN TECH/HPL
60
-
-
Surface mounting LED downlighter with white power coated aluminium housing with integrated electronic driver 15 watt in repair, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sqmm with suitable size of 40/42 watt, complete all as specified and directed. Make : Havells,cat part no:ENDURANEOHESURFACEDLS15WLED84OS or technocommerically equivalant make of Crompton/Philips/BENLO/EVEREADY/ASCEN TECH/HPL.
30
-
-
Repair Round shape 18 watts 220 volts AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.Make:- Havells/Polycab/Crompton/Wipro/HPL/EVEREADY/ ASCEN TECH/BENLO.
30
-
-
LED Street light fitting made out of pressure dia cast aluminium housing with IP65 protection of 35 watts LED cool day light complete fitted on bldgs with suitable dia of GI pipe medium grade 1.5 m in length long with suitable size of 2 nos MS flat clamps FI-25X3 mm including nuts bolts including connecting up with PVC copper conductor wire 1.5 sqmm s/c from security light to ceiling rose etc., complete all as specified and directed.
Make Havells or technocommerically equivalant Philips/Crompton/EVEREADY/ASCEN TECH/BENLO/HPL. Note: (i) Contractor shall produce LM 79 & LM 80 test report from OEM owned NABL accredited laboraory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 2 years from the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70% material at site for approval of GE before incorporation in the work.
75
-
-
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
-
-
-