Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date20 Sep 2024
Closing DateCancelled
Tender Amount₹ 13,14,000
Costs
EMD
₹ 26,280Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675586_1Bid Award Id
ViewTender No
CWE/RAJ-37/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down old / unservicable LT U/G cable, keeping away from site and supply, laying and testing of cable XLPE Insulated, Screened PVC bedded, galvanized steel strip or wire armoured, electric Power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sq mm 3 1/2 core complete all as specified and as directed
30
-
-
Taking down old / unservicable LT U/G cable, keeping away from site and supply, laying and testing of cable XLPE Insulated, Screened PVC bedded, galvanized steel strip or wire armoured, electric Power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sq mm 3 1/2 core complete all as specified and as directed
180
-
-
Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade of size 95 sq mm 3 core complete all as specified and as directed.
55
-
-
Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI for rupturing capacity upto 25KA, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50x50x6 mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables including Glands as approved drawing before manufacturing of Panel by GE. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, bus bar capacity 600 amps and consisting of following:-
Incomer MCCB
(a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA Nos-1
Outgoing MCCB
(a) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. Nos-4
(b) Digital Multifunction meter with LED display- 01 Nos
(c) LED phase indication lamps RYB-01 set
(d) Cupper Bus Bar rating 400 amps including Painting etc.
1
-
-
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip of size 32x6 mm (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
6
-
-
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 11 KV 3 core XLPE armoured aluminium conductor cable of 50 to 95 Sqmm including testing and commissioning, complete all as specifed & directed.
2
-
-
Shifting of 100 KVA Transformer from the existing site (Transit camp) to the KALSIAN. complete all as specified and directed by Engineer-in-Charge.
1
-
-
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft / lose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
66.82
-
-
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed.
41.31
-
-
Removing excavated material soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
25.51
-
-
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified.
18.22
-
-
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
1.8
-
-
GI tubing (light grade) with all fittings, laid in trenches or under road crossing as protection pipe, or fixed alongwith walls/poles with clamps including bolts, nuts & washers, bore of pipe 50mm, complete all as specified.
12
-
-
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 21 of tender doucments.
-
-13250
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements