Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date15 Jan 2025
Closing Date21 Feb 2025
Tender Amount₹ 6,95,89,000
Costs
EMD
₹ 6,73,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693275_1Tender No
CEAFU-15/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Sch 'A' PART-II ( Section-II) (Internal water supply works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
S&F Two way bib cock ,cast copper alloy , chromium plated with wall flange quarter turn (Low-flow) 16 mm dia. complete all as specified and directed
34
-
-
... More
S&F Pillar Cock (Low-flow) 16 mm dia. cast copper alloy , chromium plated complete all as specified and directed .
34
-
-
... More
S&F Sink Cock with Regular Swinging Spout (Table Mounted Model) (Low-flow) 16 mm dia.cast copper alloy , chromium plated complete all as specified and directed
17
-
-
... More
Supply & Fixing 15 mm bore Brass Wall Mixer ( 2 in 1) for mixing hot & cold water screwed down for iron pipe including all fittings and flange,etc. complete all as specified & as direcetd.
34
-
-
... More
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed by Engineer-in-Charge..
34
-
-
... More
Total amount of Schedule 'A' PART-II (Section-II) (Internal water supply works)
-
-
-
... More
Total amount of Sch 'A' PART-IV (SECTION-I) ( INTERNAL ELECTRIC SUPPLY WORKS)
1
1130898
-
... More
Sch 'A' PART-IV ( Section-II) ( INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
S & F modular type 6 Amp 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
530
-
-
... More
S & F modular type 6 Amp 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
16
-
-
... More
S & F modular type 16 Amp 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
51
-
-
... More
S & F modular type 2/3 pin combined shuttered type 6 Amp socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
187
-
-
... More
S & F modular type 2/3 pin combined shuttered type 16 Amp socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
51
-
-
... More
S & F modular type 20 Amp 1P MCB with socket, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
34
-
-
... More
S & F MCB ,32 A, 230 V, 50 Hz, 2P MCB ('B' curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
37
-
-
... More
S & F MCB ,16 A, 230 V, 50 Hz, 2P MCB ('B' curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
1
-
-
... More
S & F 20 W surface / wall mounted LED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of 90 lumen/W, CRI 80, PF 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.
155
-
-
... More
S & F 10W 2 Feet LED Batten capable delivering 1000 lumen having luminous efficacy of 100 lm/W, starting time 0.5 s, CRI 80, CCT 6500K, PF 0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the engineer-in-charge.
51
-
-
... More
S & F 12W LED Downlight having Luminous efficacy of 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed by the engineer-in-charge.
23
-
-
... More
S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep, 1325 RPM with, blades, and frame and louvers complete all as specified and directed by engineer-in-charge.
17
-
-
... More
S & F modular type 1 module RJ-11 telephone scoket with shutter complete all as specified and directed by the engineer in charge
17
-
-
... More
S & F modular type 1 module co-axial type TV socket all as specified and directed by the engineer in charge
34
-
-
... More
M&L for Design ,supply and Install (DCU) data concentrator RF based unit for the 17 Nos of smart meters for the real time data metering data such as consumption of energy,any critical evenets/faults ,power consumption etc along with complete display unit with supporting infra like suitable battery back up / chargers /saftey device etc complete all as specified and directed by engr in charge.
1
-
-
... More
Total amount of Sch 'A' PART-IV (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
-
-
-
... More
Total amount of Sch 'A' PART-VI (SECTION-I) ( ROAD/PATH/CULVERT AND HARD STANDING ) )
1
2570844
-
... More
SCHEDULE `A' PART-VI(SECTION-II) ( ROAD/PATH/CULVERT AND HARDSTANDING) ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Material & Labour for making of central line/ edge line rad marking over speed breaker over bituminious pavement roads using thermoplastic limit (as per ASTM D36/Bs-3262-Part-l as approved by GE) (Hot application) white/yellow indigenous modern propelier road marking machine with single coat of 2.5mm thk as directed by Engr-in-charge including cost and conveyance, all ingredients such as binder, glassbeads, titanium dioxide, calcium carbonate, inters pillars, pigments as per MORTH specification of clause 803.4.1.2/ table 800-9 for the preparation of thermo plastic requirements the glass beads (Type-ll) confirming to MORTH specification clause 803.4.2.3 be sprayed at the rate of 250 gms/ sqm in succession the rate to include cost of all other materials labour charges for mixing the ingrediants to the required temperature, cleaning the road surfaces, pre marking cautionery sign boards, red flags, traffic cans as per traffic rules, safeguarding the newly painted centre line marking complete all as specified and directed.
48
-
-
... More
Total amount of Sch 'A' PART-VI (SECTION-II) ( ROAD/PATH/CULVERT AND HARDSTANDING)
-
-
-
... More
Total amount of Sch 'A' PART-VI (SECTION-I)( SEWAGE DISPOSEL )
1
180365
-
... More
Sch 'A' PART-VI ( Section-II) ( SEWAGE DISPOSEL ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Construction of Soakage Wells size 1.8 M dia 3. 0 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and sceen chamber made of Brick masonary in CM 1:4, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Construction of Conventional type RCC Septic tank 100 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and as directed.
1
-
-
... More
Total amount of Sch 'A' PART-VI ( Section-II) ( SEWAGE DISPOSEL )
-
-
-
... More
Total amount of Sch 'A' PART-VII ( AREA DRAINAGE )
1
307285
-
... More
Total amount of Sch 'A' PART-VIII (FENCING AND GATE )
1
511882
-
... More
Total amount of Sch 'A' PART-IX (SECTION-I) (FIRE FIGHTING SYSTEM)
1
316430
-
... More
SCHEDULE `A' PART-IX (SECTION-II) (FIRE FIGHTING SYSTEM) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Supply and Install Booster pump 36 meter head discharge 900 LPM, 415 volts, 50 Hz, 3 phase including welding work all fittings such as nuts , bolts, washers and rubber gasket etc complete in all respect all as specified and as directed.
2
-
-
... More
Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
1
-
-
... More
M &L signage made of aluminium of Hydrants of appropriate size complete all as specified and directed.
10
-
-
... More
M &L signage of fire point of appropriate size complete all as specified and directed.
10
-
-
... More
S & F Escape lighting and exit sinage wall mounted suitable for multistories buildings Aluminium housing with Four hour battery back up all as specified and directed.
5
-
-
... More
Supplying, Installation, testring & commissioning talk back slave station in surface / recess suitable for operation on simplex mode complete with PTT knob & speaker / microphone enclosed in a MS (16 SWG) / ABS box with break glass in fron
5
-
-
... More
Supplying, and drawing of cable Fire Reterdant PVC insulated copper conductor cale in the existing surface / recessed steel conduit of following pairs cores and size including connections and interconnections etc as required complete as required complete all as specified and directed.
Speaker cable Two pair , 2- core, 1.5 sqmm
50
-
-
... More
Supplying , installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system monitoring system including connections, interconnections etc complete as required .
6 zone panel for fire alarm system
100 watt amplifier racks suitable for operation on 230V AC / 24V DC supply conforming to IEC - 268-3 complete with all accessories as required -2 Nos ( one to act as standby) Talk back master station with LED PTT (press to talk) push botton for operation on 230V AC/24V DC supply conforming to IEC-268 for simplex mode of operation / communication suitable for 20 Nos , talk back unit - 1 set.
Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -01 set.
Amplifier change over switch for inter changing amplifier -01 No, Monitor panel for loudspeaker complete output selector ON/OFF.
Switch fuse visual indications etc complete as required -01 No,
Gooseneck microphone with stand and ON/OFF switch -01 No,
Mains ON/OFF switch fuse indication lamps DC and AC voltmeters & ammeters terminals block etc, complete as required - 01 set.
Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 Nos, 12 volt, 30AH each sealed maintenance free batteries - 01 set.
1
-
-
... More
Supplying, installing, testing & commissioning of cabling for fire detection and alarm system 1.5 sqmm with 2 core an standard copper conductor PVC insulated, flexible FRLS, wires in new MS conduits as required and complete all as specified and as directed by Enginner in Charge.
50
-
-
... More
S and F Fire Extinguisher ISI marked ABC Powder type multipurpose 4 Kg complete all inclusive with standard fittings,Hose,Pressure guage and accessories complete in all respect with wall mounting arrangement complete all as specified and directed.
7
-
-
... More
S and F Fire Extinguisher ISI marked CO2 Type 3 Kg suitable for Class B and C fires complete all inclusive with standard fittings,Hose,Pressure guage and accessories complete in all respect with wall mounting arrangement complete all as specified and directed.
7
-
-
... More
S and F fire stand along with 4 buckets made out of alloy steel duly painted in bright red colour and marked with fire logo all as specified and directed.
7
-
-
... More
Total amount of SCHEDULE `A' PART-IX (SECTION-II) (FIRE FIGHTING SYSTEM)
-
-
-
... More
Total amount of Sch 'A' PART-X (LIGHTNING PROTECTION)
1
65104
-
... More
Total amount of Sch 'A' PART-XI (TV CONDUIT)
1
511882
-
... More
Total amount of Sch 'A' PART-XII (LIFTS)
1
2645274
-
... More
Total amount of Sch 'A' PART-XIII (HOT WATER SUPPLY)
1
365208
-
... More
Total amount of Sch 'A' PART-XIV ( SECTION-I)(EXTERNAL WATER SUPPLY)
1
430084
-
... More
SCHEDULE `A' PART-XIV (SECTION-II) (EXTERNAL WATER SUPPLY) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type confirming of IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 ) , totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15 mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following: (A) Bus Bar (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs. B. INCOMER (i) MCCB Cap 63 Amp, 4 pole, 415V, 50 c/s confirming to IS:13947(Part-3) 1993, 25 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos
1
-
-
... More
(C) OUTGOING: (a) MCCB Cap 40 Amp, 4 pole, 415V, 50 c/s confirming to IS:13947(Part-3) 1993, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 02 nos ( 1 w+01 S/by) (b) MCB TPN capacity 40 Amps, 415V, 50 c/s confirming to IS:13947(Part-3) 1993, 10 KA - 01 No. (c) MCB SPN capacity 32 amp, 'C' series-01 Nos (D) Star -Delta(Automatic) starter suitable upto 07 HP motor 3 Phase, 415 volts 50 c/.s for induction motor pump including protection against over volatge,under voltage, over current , under current,reverse phasing , single phasing , earth fault etc protetion relays -02 Nos (D)METERING & MISC: (i) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete (ii) Indication lamps LED type (RYB) =01 set of three (iii) Volt meter (0-500V) digital type with selector switch-01 No. (iv) Ammeter (0-200 amps) digital type with CTs and selector switch-3 No E.Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, rendering in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel. Note: (i) LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 ) (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by Approved agency in respect of LT Panel (iii) Contractor shall submit drawing for approval prior to place order.
-
-
-
... More
Supply, Installed Testing and Commissioning Altoch chlorine dosing system consisting of 100 litres PE /FRP tank with PE / FRP lid and level gauge along with Agitator (1280 RPM) pump complete set (Hypo Chlorine chemical dosing System) incl chemical supply line & injection points & power of motors (AC Induction motor) with Gear box, 230V, 120 watt, 1280 RPM, 50HZ, panels are integrated with shaft and blade (FRP / Epoxy coated) plastic mounted on tank lid having port hole for pouring Altoch and water as required. Lid having provision for mounting Dosing pump on lid Agitator motor 90 watts, 1440 RPM 230V, 50 HZ, 0.2 Amps and having speedcontroller to reduce speed upto 800 rpm Electronic solenoid operated pumps, interconnecting tubing / piping, mixing tank 100 ltrs with mixture / agitator & instruments like pressure gauge, pressure switch, pressure transmitter, ORP Sensor, with granuals (Altoch GP) 45 kg,Chlorine sensor , PPM valve display , duly mounted on structure frame with Agitator support including suction and drain out pipe connection with valve complete fixing accessories complete set all as specified and directed by Engr-in-Charge. (Make:- DECLIBAC / UNITED ENGINEERING / POTER & WATT CORP / BRIOZING UNLIMITED).
2
-
-
... More
M & L for wall pit chamber internal dimension of 900 x 900 x 750mm built in brick masonry in cement mortar (1:6) including waster concrete PCC (1:4:8) mixed type D2 100mm thick. Plastering to brick work cement mortor 1:6. 15mm thick internally and externally including provision of 3.15mm thick MS sheet cover fixed with angle iron frame of size 50x50x6 abandon in PCC 1:2:4 mixed type B-1 including copying of 100mm thick with PCC 1:3:6 type C2 painting to steel and iron work two coat of synthetic enamel paint over one coat of red oxide of primer necessary earth work and excavation in any type of soil complete with locking arrangement all as specified. Inclusive of dismantling of existing damage wall pit chamber and disposed of the retrieved material all decorated by Engineer-in-Charge.
3
-
-
... More
S & F Cast iron air release valves with two air outlets, 50mm bore and fixing Up in cast iron water supply mains of size 100 mm dia complete all as specified and directed.
1
-
-
... More
M & L for SMC panel tanks for water storage capacity 11000 ltrs as conforming with IS 14399: 1996 and material conforming as per IS 4249 :1967 for fire retardant require capacity of suitable size including MS angle / channel frame work complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M & L for open bell type submersible pump with motor sets, electric driven, 3 phase, 415 V, 50 HZ ,discharge 366 LPM, capacity 7.5 HP complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Total amount of SCHEDULE `A' XIV (SECTION-II) (EXTERNAL WATER SUPPLY)
-
-
-
... More
Total amount of Sch 'A' PART-XV ( Section I) (EXTERNA LELECTRIC SUPPLY)
1
201693
-
... More
Sch 'A' PART-XV ( Section II) (EXTERNA LELECTRIC SUPPLY) (External water supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
S&F LT cable junction box outdoor shall be made out of polycarbonate with glass fiber reinforced then 205mm x 255mmx112mm ( the cable size upto 25sqmm) . The polycarbonate junction box shall be enviroment friendly, recyclable, halogen and silicon free, anti acid & anti corrosive . The junction box shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. weather proof , UV resistant. The gasket material of junction box shall be polyurethane and the gasket shall be internally embeded. The junction box shall be complies with requirement of the standards IEC 60998. The junction box with 25Amp connectors or terminal Trip or bus bar . The junction box / Enclosure shall be tested as per IEC including one No 4 pole connector and chlomium plated clamps and nuts, bolts, cable glands with lock nuts of 2 Nos for each box complete all as per menufacturer complete all as specified and directed.
Make: Cat part No. KF2525B of Hensel / Siemens / Legrand / GE Power.
8
-
-
... More
S&F LED avaiation light luminaires ,integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including connecting electricaly to location using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required and directed by Engr-in-Charge.
2
-
-
... More
Supply, installation, testing and commissioning outdoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 200 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No . ( Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
1
-
-
... More
OUTGOING: (a) MCCB Cap 125 Amp, 4 pole, 415V, 50 c/s 25 KA-02 No, MCCB Cap 100 Amp, 4 pole, 415V, 50 c/s 25 KA-02 No, Make : L&T or equivalent in Legrand / Schnieder / Havells / ABB (b) MCB TPN capacity 63 Amps, 415V, 50 c/s 10 KA-01 No. Make : Legrand / Schnieder / L&T/ Havells / ABB / Siemens (c) MCB SPN capacity 32 amp, 'C' series-01 Nos Make : Legrand / Schnieder / L&T/ Havells / ABB METERING & MISC (a) Volt meter (0-500V) digital type with selector switch-01 No. Make : Secure or equivalent approved make. ( b) Ammeter (0-200 amps) digital type with CTs and selector switch-3 No Make : Secure or equivalent approved make. (c) Set of indicating lamp LED type-01 Set . (d) Civil work PCC 1:2:4 for grouting of panel complete including excavation, earth work.
-
-
-
... More
Supply, installation, testing and commissioning indoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 2.00mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 2.00 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 200 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No . ( Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
1
-
-
... More
OUTGOING: (a) MCCB Cap 63 Amp, TPN, 415V, 50 c/s 25 KA-05 No, (04 No working +01 spair) Make : L&T or equivalent in Legrand / Schnieder / Havells / ABB (b) MCB TPN capacity 40 Amps, 415V, 50 c/s 10 KA-02 No. Make : Legrand / Schnieder / L&T/ Havells / ABB / Siemens (c) MCB SPN capacity 32 amp, 'C' series-02 Nos Make : Legrand / Schnieder / L&T/ Havells / ABB METERING & MISC (a) Volt meter (0-500V) digital type with selector switch-01 No. Make : Secure or equivalent approved make. ( b) Ammeter (0-200 amps) digital type with CTs and selector switch-3 No Make : Secure or equivalent approved make. (c) Set of indicating lamp LED type-01 Set . (d) Civil work PCC 1:2:4 for grouting of panel complete including excavation, earth work. (e) Digital Multi function meter for Ammeter, Volt, KWH, PF, frequency etc 3 phase 4 wire of suitable capacity.-01 No. Make : Secure or equivalent approved make. (f) Panel shall be installed at least 45 cm above ground level.
-
-
-
... More
Supply, installation, testing and commissioning outdoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 100 Amp, 4 pole, 415V, 50 c/s 25 KA-01 No . Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
1
-
-
... More
OUTGOING: (a) MCCB Cap 63 Amp, 4 pole, 415V, 50 c/s 16 KA-03 No, (02 No working +01 spair) Make : L&T or equivalent in Legrand / Schnieder / Havells / ABB (b) MCB TPN capacity 40 Amps, 415V, 50 c/s 10 KA-02 No. Make : Legrand / Schnieder / L&T/ Havells / ABB / Siemens (c) MCB SPN capacity 32 amp, 'C' series-01 Nos Make : Legrand / Schnieder / L&T/ Havells / ABB (d) Star / delta starter suitable upto 07 HP 3 phase, 415V, 50 c/s induction motor including protection against over voltage, under voltage, over current under current reverse phasing, single phasing, earth fault etc Qty 02 No, Make : L&T or equivalent model in BCH / Havells / ABB / Legrand / Schnieder METERING & MISC (a) Volt meter (0-500V) digital type with selector switch-01 No. Make : Secure or equivalent approved make. ( b) Ammeter (0-200 amps) digital type with CTs and selector switch-3 No Make : Secure or equivalent approved make. (c) Set of indicating lamp LED type-01 Set . (d) Civil work PCC 1:2:4 for grouting of panel complete including excavation, earth work. (e) Digital Multi function meter for Ammeter, Volt, KWH, PF, frequency etc 3 phase 4 wire of suitable capacity.-01 No. Make : Secure or equivalent approved make. (f) Panel shall be installed at least 45 cm above ground level.
-
-
-
... More
M&L laying well burnt old size Fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
6000
-
-
... More
Supply and Fix CI cable route indicators of appropriate size including excavation and PCC foundation work complete all as specified and directed by Engineer in Charge.
5
-
-
... More
Total amount of Sch 'A' PART-XV ( Section II) (EXTERNA LELECTRIC SUPPLY)
-
-
-
... More
Sch 'A' PART-XVI(DG SET) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Supply,install ,testing, commissioning of 'Silent type' diesel generating set alongwith having prime power rating of 40 kVA/32 kW,415Volts at 1500RPM , 0.8 lagging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor ,CPCB-IV /latest norms complied, acoustic enclosure,realy panel for automatic starting on main failure(AMF), anti vibration mountings,control panel and foundation.The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame.The DG set power rating indicated above is inclusive of altitude correction factor however the DG Set shall be designed and suitable to operate as per tropical condition of Udhampur Area and for more details on service condition refer particualr specification.The DG set shall be comprising of following item as under:- (a)Diesel Engine : The diesel engine shall be of four stroke cycle multi-cylinder,direct injection water cooled, turbo charged with after cooler, Air to air aftercooling and optimised turbocharger for increased altitude capabilities developing required BHP/KW @ 1500 rpm for a 40 KVA Alternator under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation,suitable for generating set application on AMF mode.The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046The engine shall have the following accessories:
Cooling fan and radiator. DM water cooling systems with pre-mix anti-corrosive additive Turbocharger. Fly wheel with fly wheel housing. Electrical engine starter motor (disengagement after start-up) with Batteries. Battery charging systems. Stainless steel exhaust flexible elbow. Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer. Required filters for fuel, lube oil, air etc. Sets of flexible hoses as required. Suitable rubber coupling to Alternator with guard. Suitable Engine controller for protection of the engine. Coolant heater and crankcase heater. Oil drain Pump. Heavy duty air cleaner. (c)Starting system :The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12volts/24 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initail exciation complete with suitable number of batteries(25 plates, 180AH Sealed Maintenance Free (SMF) Lead-Acid type) as required as per specifications.The battery shall be supplied with a suitable floor mounted MS stand treated with seven tank treatment, two coats of red oxide /primer & acid resistant paint.with wooden base, adaptor box etc . with copper conductor battery leads of required length and socket/clamps
1
-
-
... More
Item 27.03 Cont..(d ) Alternator :40 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm self-excited and self regulated through AVR confirming to IS :4722/BS 2613 suitbale for tropical condition with brush less exciter, housed in screen protected drip proof enclosure. The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delivering rated output at rated power factor with,a. Terminal voltage differing from the rated value by not more than +/- 5%.
b. Frequency differing from the rated value by not more than +/-0.5%.
c. Short circuit capacity of 300% for 10 seconds.
d. Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class F/ H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters. (e) Alternator Protection :Alternator should have following protections Over and Under voltage Under and Over frequency warning and trip
Loss of excitation Over current and Earth Fault and Short Circuit Protection
Unbalanced loads Restricted Earth Fault Protection. Differential protection. Diode Failure. (f) Voltage regulator :A rapid response voltage regulator shall be provided to regulate the generated voltage.The overall regulations from no load to full load,
including cold to hot variation and load power factor of 0.8 lag to unity shall be within 2% of the normal voltage. The excitation system shall be designed to promote rapid voltage recovery following sudden application and disconnection of load. (g) Acoustic enclousure : The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB-IV norm.Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper
parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less than 75 db (A) at a distance of 1 meter.High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ ISO 8528 (Part 10) standard.The canopy has the provision of emergency push button, external to the canopy
-
-
-
... More
Item 27.03 Cont..(h) Governor :The governor shall be of electronic type suitable for monitoring
constant engine speed within the specified limits for auto parallel and auto load sharing operation. (j) Exhaust : The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB.The exhaust piping and the silencer shall be wrapped with rock wool and/or calcium silicate. The outside shall be neatly wrapped with aluminum cladding. The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms.Suitable supporting structure for installation shalll be provided. (k) Hot air exhaust (Radiator cooling): GI duct shall be provided for hot air exhaust from DG set up to designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galvanized Iron (GI) Sheet.Galvanised Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from
radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall. (l) Fuel Tank : Inbuilt/internal bottom mounted (with-in DG set or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent, drain plug, level indicator, inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated as per tropical conditionof Leh with 210 Litres approx. capacity or designed capacity shall be suitable for 8 hrs continous operation. (m) AMF Control Panel :The control panel shall be designed for Automatic ON Mains Failure Operationof the Generator sets. The Panel will be totally enclosed, Dust tight, vermin proof,floor mounted, free standing, cubical compartmentalized type with hinged doors, fabricated from 14 SWG CRCA Steel metal having separatecompartments . The Panel will be epoxy painted powder coated with light grey shade, After Seven Tank treatment, and the Panel / compartment will be fitted with the following instrument and pre-wired with colour coded flexible copper cable with ferule Numbers for easy identification & maintenance. The panel shall be complete with interconnections, insulators, two nos. of earthing lugs and with suitable rating of MCCB at both the end & shall incorporate the followings (i)Neutral contactors.(ii) AMF PLC logic unit having protection for over frequency, under frequency, over voltage, under voltage, Low lube-oil, and high water temperature for Engine.The AMF unit will have provision for Auto Start, Auto Stop of the D.G.Set,with 3 attempts cranking relay.(iii) Main supply voltage monitor.(iv)Combined Meter (MFM) for Voltage, Current, Frequency, KVA,KWH & P. F.(v) CT’s of suitable rating (vi) Static Battery charger connected on mains consisting of Transformer, Rectifier, D.C. Voltmeter, D.C.Ammeter, charging rate selector switch (Trickle/Boost, Indicating Lamp, onoff switch)(vii) Auto / Manual mode switch(viii) Miniature Circuit Breaker for Fuses(ix) Hooter 24 volt(x) Annunciations, Alarms & Trips for High water Temperature,Over speed,Set fails to start and D.G. overload (xi) Push Buttons for Breaker on-off,D.G. Start / stop,Engine Trip,Hooter Accept and For Reset (xii)Indicating Lamps for Load on mains,Load on D.G. Set,Low lube oil pressure and High water temperature (xiii)Suitable size of Tinned Copper bus bar will be provided with current density of 1.2 Amp per mm².
-
-
-
... More
Item 27.03 Cont..(xiv) Set of relays and contractor of suitable capacity with MCCB, 4 pole, OF suitable Amps ratings , 415 Volt. KA for automatic start & automatically shut down of DG set or as per manufacturer recoomendation of suitable rating & capacity - 02 Nos. (xv) By pass arrangement by providing on laod change over switch of suitable rating in Amps 4 pole to be installed with AMF- 01 Nos. Note : 1.AMF Panel shall be installed outside the acoustic enclousre (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel) should be provided by the contractor .(iii) Cost of DG set foundation deemed to be included in cost of item.(iv) Contractor should submit necessary drawing to GE/Engr-in-Charge before placing the order.
-
-
-
... More
Total amount of Sch 'A' PART-XVI(DG SET)
-
-
-
... More
Total amount of Sch 'A' PART-XVII(Site clearance, excavation & earth works)
1
854611
-
... More
Total amount of Sch 'A' PART-XVIII (Sanitary/Plumbing Work)
1
118159
-
... More
SCHEDULE `A' PART-XIX (Operation of Lifts and AMC ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Phase-III : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
11
-
-
... More
Phase-IV : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
11
-
-
... More
Phase-V : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
12
-
-
... More
Phase-VI : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
11
-
-
... More
Phase-VII : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
12
-
-
... More
Phase-VIII : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
11
-
-
... More
Phase-IX : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
12
-
-
... More
Phase-X : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
11
-
-
... More
Total amount of SCHEDULE `A' PART-XIX (Operation of Lifts and AMC )
-
-
-
... More
NOTE: Amount against schedule of credit of Rs. 4,960.00 for retrieved materials mentioned under relevant part XIV of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%