Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Oct 2024
Closing Date13 Nov 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disconnecting and taking down the worn out jumpers in 33 KV yard and supply and fix new jumpers cutting to adequate length of ACSR conductor panther complete all as specified and directed.

2

-

-

... More
Material and labour for dehydration / filtration of distribution transformer oil of transformer in position till the di-electric strength of transformer oil is not less than 50 KV when measured at 2.5 mm gap for one minute including filling of new transformer oil as required for top up upto oil level complete all as specified and directed by Engr-in-Charge. Note : - New transformer oil as required shall be measured and paid separatly under respective item as supply only.

5000

-

-

... More
Supply and filling new transformer oil with dielectric strength not less than 60 KV for distribution transformer when measured at 2.5 mm gap for duration of one minutes, complete all as specified and as directed by Engr-in-Charge.

2100

-

-

... More
Supplying, installation, commissioning and testing in replacement of 33 KV Current Transformer (CT`s),outdoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 400/1-1 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA/as existing in MRS for metering including associated wiring complete all as specified and directed

1

-

-

... More
Supplying, installation, commissioning and testing in replacement of 33 KV Potential Transformer (PT`s),outdoor type, as existing at MRS all as specified and directed

1

-

-

... More
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 200/5-1 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering including associated wiring complete all as specified and directed.

4

-

-

... More
Supplying, installation, commissioning and testing in replacement of 11 KV Potential Transformer (PT`s), indoor type,/as existing including associated wiring complete all as specified and directed.

1

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for taking out HT underground cable and laying of new underground cable in replacement and getting out in soft / loose soil complete all as specified and directed by the Engr-in-Charge.

515

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge .

395

-

-

... More
Removal of surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge.

120

-

-

... More
Material and labour for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed by Engr-in-Charge.

115.8

-

-

... More
Supplying and laying in replacement of Un-reinforced precast concrete cable cover ' factory made' of class HV, Type 1 with peak, of size 300 mm x 180 mm x 40 mm complete all as specified and directed by Engr-in-Charge.

2460

-

-

... More
Taking out carefully unserviceable XLPE HT under ground cable of size 95 Sqmm /3-Core to 120 Sqmm /3-Core from trenches / Pipes including taking out bricks, complete all as specified and directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)

1310

-

-

... More
Supply, Laying, jointing, and testing in replacement of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade(Earthed) and cross sectional area 95 sqmm 3 core confirming to latest IS and ISI marked complete all as specified and directed by Engr-in-Charge.

480

-

-

... More
Laying only XLPE insulated, PVC inner sheathed, armoured, HT underground cable of size 95 Sqmm / 3-core to 120 Sqmm/ 3-Core (retrieved from item No 17 of BOQ) laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified and directed. Note:- (i) Earthwork, sand cushion, will be measured and paid separately.

830

-

-

... More
Material and labour for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petroleum jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of LED indication lamp for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc for 11/33 KV control panel including associated wiring, if reqd, complete all as specified and directed.

25

-

-

... More
Material and labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation as bushes grows during a period of contract and removing all rubbish to a distance not exceeding 50 m as directed.

130

-

-

... More
Material and labour for repairs/maintenance of 11KV HT VCB/ SF6 breakers Panel including bus coupler of any type, size and capacity complete including the following :- Taking out 11KV HT VCB/OCB/SF6 breakers of 400/630/800 Amps rating trolley from HT Panel after switching off electric supply, checking of mechanical/motorised system for proper functioning of upward/downward movement of HT VCB trolley including opening the VCB & checking the quality of insulating. Cleaning & servicing the fixed/moving contact & blowing out dust from bus bar chamber, spout gear mechanism and applying the proper lubrication/greasing and cleaning/servicing the entire motorised mechanism of VCB including all spare parts required at site, reassembling the VCB connection, testing, commissioning and putting on load to the entire satisfaction of Engr-in-charge.

12

-

-

... More
Material and labour for replacement of Earthing complete with copper plate electrode 600x 600x 3 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level with top edge of earth plate, not less than 1.5 mtr below normal ground level connected to copper strip earth lead of size 20 x 3 mm by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 50 mm dia and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm cc both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3 SSR Part I and testing complete including removing unserviceable any type of items all as specified and directed. Note : Copper strip and GI pipe 50 mm dia beyond 7.5 metres per earth will be measured and paid separately.

4

-

-

... More
All as per item No. 23 above but using 32 x 6 mm galvanised MS strip earthing lead and MS galvanised plate of size 600 x 600 x 6 mm as earth electrode.

4

-

-

... More
Supply & Fix Gasket in replacement for upto 6.3 MVA transformer (SRC RC 70C Grade) with including all required T&P for drain out and refilling trainsformer oil after proper filteration,comminissioning and testing complete complete all as directed.

2

-

-

... More
Testing and re-setting and calibration of protection relay of 11 KV RMU/VCBs/SF6 breaker (indoor/outdoor) for incoming and out going feeders with control panel and control cable differential relay through authorised service engineer, Checking of instruments function and taking corrective action for improvement if found improper, Checking the condition of transformers (Oil & winding temp and B/H relay) and taking corrective checking and operating the switchgear and trip circuit of HT panel/breakers for its proper functioning complete all as specified and directed. Note:- Reports after calibration to be submitted and the autherised techinicion should attend the malfunctioning/routine service complaints as and when required for entire contract period under warranty.

12

-

-

... More
Material and labour for replacement of stay assembly complete with accessories as shown in electrical plate no 1 including loop type isolator stay clamps stay strands excavation work and PCC work with 20 mm dia complete all as specified and directed.

3

-

-

... More
Supply, fixing and testing in repair power pack with battery backup input 230 V AC, output 110 V DC, 1Amp suitable for existing HT 11 KV VCB panel complete all as specified and directed.

1

-

-

... More
Material and labour for replacement of Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified. Make:BHEL, PACTIL OBLUM, ABB

3

-

-

... More
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive on one primer coat, one under coat and one finishing coat of paint.

1.2

-

-

... More
Supply, Install and erect steel tubular swaged pole type 410 SP-55 of 11.0 mtrs long complete with cast iron base plate finial taper plug, pole cap, bolts, nuts and washers pole made out of MS tubing confirming to IS-2713 Part-II, including drilling of holes painting with two coats of bituminous paint internally and externally embedded portion in ground/concrete and painting to exposed surfaces with two coats aluminium paint and one coat of red oxide primer complete all as specified and directed. Note :- Excavation/Earth work in any type of soil/ strata PCC foundation, coping of poles, cross arms, clamps shall be measured and paid separately. Make :- M/s Bombay Tubes/ M/s Jindal Steel Products/ M/s India Tubes Co/ M/s Bharat poles/ National Tubing.

2

-

-

... More
Supply, Install and erection of steel tubular swaged pole type 410 SP-31 of 9.0 mtrs long complete with cast iron base plate finial taper plug, pole cap, bolts, nuts and washers pole made out of MS tubing confirming to IS-2713 Part-II, including drilling of holes painting with two coats of bituminous paint internally and externally embedded portion in ground/concrete and painting to exposed surfaces with two coats aluminium paint and one coat of red oxide primer complete all as specified and directed. Note :- Excavation/Earth work in any type of soil/ strata PCC foundation, coping of poles, cross arms, clamps shall be measured and paid separately. Make :- M/s Bombay Tubes/ M/s Jindal Steel Products/ M/s India Tubes Co/ M/s Bharat poles/ National Tubing

1

-

-

... More
Material and labour for PCC 1:3:6 type C2 using 40 mm stone aggregate for foundation of poles/transformer bed/cable duct foundation/panel base/ chain link supports etc including necessary form work etc complete all as specified and directed.

1.35

-

-

... More
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole including necessary form work etc complete all as specified and directed.

2

-

-

... More
Material and labour for spreading the 20mm coarse aggregate in various sub stations and other locations complete all as specified and directed.

10

-

-

... More
Supply and fixing in repair of Impluse Emergency First aid kit box with basic medicine like Band Aid strips of min 20 Nos, Anteseptic cream, Cotton, Surgical tape 1 inch, non sterial gauge swabs, Hydrogen peroxide bottle, medical spirit bottle complete all as specified and directed.

6

-

-

... More
Material and labour for Preparation of old painted inner and outer surfaces of indoor/out door HT/LT panels, spray painting the same with two coat of synthetic enamel paint grey and a coat of red oxide primer to achive smooth finish including writing of SM/MES No complete all as directed.

10

-

-

... More
Testing and re-setting and checking connection of control cable from transformer tap changer to panel of auto tap changer relay up to 6.3 MVA transformer through authorised service engineer, Checking of instruments function and taking corrective action for improvement if found improper, Tap changer panel l/breakers and tranformer control panel complete for its proper functioning complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs of Alarm annucator 12 window of model MBAS-0600 suitable for 33/11KV HT breaker complete all specified and directed.

1

-

-

... More
Supply and fixing in replacement of cable jointing kit for straight through joint (epoxy) for 1.1 KV grade XLPE, PVC insulated and sheathed aluminium conductor under ground cable including thimbles, nuts & bolts, washers etc and testing after jointing complete all as specified and directed for the following sizes. Make: M-seal/Raychem/Transeal/Denson 25 sqmm to 50 sqmm 3.5 core

2

-

-

... More
70 sqmm to 120 sqmm 3.5 core

2

-

-

... More
150 sqmm to 400 sqmm 3.5 core

2

-

-

... More
Material and labour painting of HT two pole structure 11 KV complete by scrapping the existing old paint and making the surfaces smooth including cross arms bracings complete and applying two coats of synthetic aluminium paint complete all as specified and directed.

5

-

-

... More
All as per Item No : 41 above but four/Six pole structure

4

-

-

... More
Labour for cutting the bushes and plants grown near the substation/ structures premises using necessary tools and plants and removing the plants from the root level at any depth and cleaning the premises completely and making good the site suitable for spreading the stone aggregate including disposing all the waste to a distance not exc 50M form the site, complete all as specified and directed by the Engr-in-Charge.

120

-

-

... More
Supply and fixing in replacement of digital type Ammeter suitable for Eleven KV breaker ranging (0-400) Amps suitable for auxilary voltage 230 volts including taking down old unserviceable Ammeter complete all as specified and directed. Make- MECCO/CONZERV

3

-

-

... More
Material and labour for spreading the 40mm coarse aggregate in various sub stations/Structure premises and other locations complete all as specified and directed.

10

-

-

... More
Cutting of trees and tree branches of girth up to 20cm and to a radius of 3M all around LT/HT OH line complete all as specified and directed. Note: The distance between two adjacent poles will be considered as one span

22

-

-

... More
Material and labour for replacement of 11KV grade pin type, Porcelien insulator of clevis/Tounge/socket or ball type spindle including nuts and bolts of size type as specified by the manufacturer including all galvanised steel fittings as required at site and removing of unserviceable insulators complete all as specified and directed. Make :- Jaipuria/Rashtriya Electrical/Denson or make approved in the state Electricity board.

12

-

-

... More
Material and labour for replacement of LT line zig zag PVC spacer including replacing the broken u/s spacers and necessary ladder arrangement should be made by the contractor during replacing as required at site.

40

-

-

... More
Supply, installation and testing in replacement of Lightening Arrestor expulsion type for outdoor use complete with all fittings station class discharge capacity 65 kilo Amps suitable for 11000 V including bracket, clamps, nuts and washers and connecting to earth wire complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Repairs to AB switch (GOD) including replacement of male and female contacts, bolts & nuts and cleaning the carbon/ dust deposited on the switch contact surfaces and applying mineral jelly, oil grease to the moving/rotating parts etc after cleaning, removing carbon deposits including testing and commissioning the same for operation complete all as specified and directed. Note: The repairs to three poles of AB switch will be measured as on job.

12

-

-

... More
Labour only for removing the binding of ACSR conductor of LT 3 phase 4 wire over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the same ACSR conductor on insulator by proper binding, jumper connection etc complete all as specified and directed.

14

-

-

... More
Labour only for removing the binding of ACSR conductor of HT 3 phase 3 wire over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the same ACSR conductor on insulator by proper binding, jumper connection etc complete all as specified and directed.

6

-

-

... More
Supply and fixing rust free Acrylic Danger notice plate duly marked voltage danger and conventional skull and bones in signal red colour written in one local language and english with retro reflective stickering and fixing with GI/MS. clamps, bolts and nuts of approved size, for LT 440 volts all as specified and directed.

8

-

-

... More
All as per item No 53 above but for HT 11000 volts.

6

-

-

... More
All as per item No 53 above but for HT 33000 volts.

12

-

-

... More
Material and labour for anti climbing devices spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.

0.5

-

-

... More
Material and labour for locating UG cable fault through high voltage UG cable testing van through TSSPDCL or any authorised service provider in HT cables of any size or distance complete all as specified and directed to the entire satisfaction of Engr-in-Charge.

8

-

-

... More
Supply and fixing rectangular RCC cable route indicator of size not less than 1m long with curved on top surface duly marking with size of cable, location including painting with two coats of synthetic enamel paint on surface directed.

80

-

-

... More
Material and labour for fabricating feeder distribution layout board on ACP sheet of thickness 3mm and size as required at site designing the layout as per the sketch provided by the Engr-in-charge using ecosolvent print including lamination and fixing to the wall using necessary fixing nuts, bolts and spares as required at site. The job includes removing of old layout board from its position complete all as specified and directed.

25

-

-

... More
Supply and fixing in repairs MS chequered plate of 6 mm thick confirming to FE 290 grade 165 including provision of lifting handle for each plate on existing cable ducts and manhole covers for semi under ground sumps including painting with two coats of synthetic enamel paint over a coat of red oxide primer all complete all as specified and directed.

1.5

-

-

... More
Supply only Male contacts suitable for 33/11 KV Air Break switch complete all as specified and directed.

10

-

-

... More
Supply only Female contacts suitable for 33/11 KV Air Break switch complete all as specified and directed.

10

-

-

... More
Material and Labour for cutting existing bitumen road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed.

25

-

-

... More
Supply and laying in replacement of GI tubing 100mm dia, light grade for cable protection at road crossing/on poles and tubing sealed at bith ends after laying the cables including taking out old GI tubing complete all as specified and directed.

35

-

-

... More
All as per iem No 64 here-in-before but 80mm dia Make : ZENITH/ TATA/ JINDAL/SWASTIC

30

-

-

... More
Supply and fixing in repairs MCCB 200 Amps, 4 pole 50 HZ, complete all as specified and directed.

5

-

-

... More
Supply and fixing in repairs MCCB 100 Amps, 4 pole 50 HZ, complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs MCCB 125 Amps, 4 pole 50 HZ, complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs MCCB 400 Amps, FP, 50HZ, complete all complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs MCCB 630 Amps, 4 pole 50 HZ, complete all as specified and directed. Note for item No 66 to 70 : Cost of fixing on to walls/surface on suitable angle iron bracket support and civil work shall be included quoted rate.

2

-

-

... More
Replacement of air breather of any type up to 6.3MVA transformer complete with filled silica gel complete all as specified and directed.

2

-

-

... More
Disconnection of all Primary/Secondary connection of the defective transformer of any KV rating, out door / indoor any make taking down / out from plinth / pole / platform with the help of crane and transporting the same carefully to workshop for repair and bringing back and install, with all connections as per directions, after repair to its existing position, upto 750 KVA capacity of transformer complete with testing and commissioning, complete all as specified and directed.

6

-

-

... More
Opening of the 11 KV / 0.433 KV transformer upto 500 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of leaked cork seal with insulator or LT/HT bush (which is unsv) complete from the shell and making again connections of LT/HT bush to avoid leakage of oil refilling back to existing oil into the transformer testing & commissioning complete all as specified and directed. Note : HT/LT bush will measured and paid separately under relevant item and cork seal with insulator is deemed to be included in quoted rate.

12

-

-

... More
Supply and fixing in replacement of air termination single pointed copper rod 12mm dia and 300 mm long including removal of the existing and complete all as specified and directed.

75

-

-

... More
Supply and fixing in replacement of Aluminium strip 25 x 3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including removal of existing and complete all as specified and directed.

100

-

-

... More
Supply and fixing in replacement of Copper strip 32 x 6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including removal of existing arrangement, complete all as specified and directed.

25

-

-

... More
Supply and fixing in replacement of Aluminium strip 25 x 4 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including removal of existing arrangement, complete all as specified and directed.

95

-

-

... More
Supply and fixing in replacement of GI strip 32 x 6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground including removal of existing and complete all as specified and directed.

70

-

-

... More
Material and labour for replacement of for Renewal of Fuse wire by using appropriate amp rating tinned copper fuse wire with all safety precaution like hand gloves Earth rod at site of any height of six/four/two pole structure complete all as specified and directed.

60

-

-

... More
Supplying only Tinned Copper fuse wire of 16SWG to 22 SWG or 30 Amps to 200 Amps capacity(200Gm packing) .

40

-

-

... More
Supply and fixing in repairs for Test point terminal block made out of gun metal or phosphorus bronzed size 75x75x25mm, drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.

20

-

-

... More
Supply and fixing in repairs for GI pipe light grade 50 mm bore , 1.2 mtr long duly threaded on both side for fixing GI socket & making necessary arragement for holding of air terminal rod all as specified and directed.

25

-

-

... More
Material and labour for replacement of Aluminium conductor, steel reinforced, Weasel type complete all as specified and directed.

1

-

-

... More
Supply and fixing in repair of HT bushing (33 KV Side) including metal parts and washer complete for any make of plinth/pole mounted transformer cap 6.3 MVA capacity complete all as specified and directed.

2

-

-

... More
Supply and fixing in repair of HT bushing (11 KV Side) including metal parts and washer complete for any make of plinth/pole mounted transformer cap 6.3 MVA capacity complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of burnt copper coil winding complete with suitable size/gauge of super copper enameled wire of high quality matching with existing size of wiring of transformer of capacity 63 KVA to 500 KVA complete all as specified and directed.

250

-

-

... More
Supply and fixing in replacement Insulation of copper strip limb for LT side with existing coil of transformer of capacity 100 KVA to 500 KVA complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing in replacement of of HV porcelain bushing of 11 KV grade with gasket complete all as specified and directed by Engr-in-Charge. (i) 63 KVA to 160 KVA

5

-

-

... More
(ii) 200 KVA to 400 KVA

4

-

-

... More
(ii) 500 KVA

2

-

-

... More
Supply and fixing in replacement of of LV porcelain bushing of 1100 volts grade with gasket suitable for the following capacity of transformer :- (i) 63 KVA to 160 KVA

8

-

-

... More
(ii) 200 KVA to 400 KVA

5

-

-

... More
(iii) 500 KVA

3

-

-

... More
Supply and fixing in replacement of of LT brass stud with 5 Nos brass nut, brass washers, check nuts, conical rubber bush for the following capacity of Transformer. (i) 63 KVA to 160 KVA

6

-

-

... More
(ii) 200 KVA to 400 KVA

6

-

-

... More
(iii) 500 KVA

4

-

-

... More
Supply and fixing in replacement of of HT brass stud with 3 Nos brass nut, brass washers, check nuts conical rubber bush for the following capacity of transformer. (i) 63 KVA to 160 KVA

6

-

-

... More
(ii) 200 KVA to 400 KVA

8

-

-

... More
(iii) 500 KVA

5

-

-

... More
Supply and fixing in replacement of tap changer rotary type suitable for following capacity Transformer complete all as specified and directed by Engr-in-Charge.. (i) 63 KVA to 160 KVA

6

-

-

... More
(ii) 200 KVA to 400 KVA

6

-

-

... More
(iii) 500 KVA

2

-

-

... More
Supply and fixing in replacement of breather assembly with fresh filling of silica-gel (colour of silica gel should be deep sky blue) capacity in non metallic breather of transformer up to 500 KVA capacity complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply and fixing in replacement of oil level indicator suitable for Transformer up to 500 KVA capacity complete all as specified and as directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing in replacement of Oil temperature gauge as per IS specification complete as specified and directed, suitable for Transformer up to 500 KVA capacity complete all as specified and as directed by Engr-in-Charge.

8

-

-

... More
Preparation of old painted surfaces of transformer and painting with two coats of synthetic enamel paint including writing SM No and MES No with approved colour paint with letters 30 mm high for the following capacity of transformer:- (i) 63 KVA to 200 KVA

8

-

-

... More
(ii) 250 KVA to 400 KVA

5

-

-

... More
Material and labour for replacement of HT Cable path indicator shall be provided at distance of min 100 mtrs and at every joint,and turning of cable . The cable path indicator should be brown colur and fixed of min 45 cm long made of 40x40x6 mm of MS angle iron frame, complete all as specified and as directed by Engr-in-Charge.

55

-

-

... More
Supply, connecting and testing in replacement of tripping coil DC 30 Volt suitable for 11KV VCB panel complete all as specified and directed by Engr in charge.

4

-

-

... More
Supply, connecting and testing in replacement of closing coil DC 30 Volt suitable for 11KV VCB panel complete all as specified and directed by Engr in charge.

5

-

-

... More
Supply, connecting in replacement of Ammeter digital type with CT ratio200/5 and current rating 0-50 Amp suitable for 11 KV VCB panel complete all as specified and directed by Engr in charge.

5

-

-

... More
Supply, connecting in replacement of Ammeter selector switch 10A/440 Volt suitable for 11 KV VCB panel complete all as specified and directed by Engr in charge.

5

-

-

... More
Supply, connecting in replacement of Voltmeter digital type 0-15 KV PT ratio, 11KV/110 Volt suitable for 11 KV VCB panel complete all as specified and directed by Engr in charge.

3

-

-

... More
Supply, connecting in replacement of voltmeter selector switch 10A/440 Volt suitable for 11 KV VCB panel complete all as specified and directed by Engr in charge.

4

-

-

... More
Supply and fixing in replacement of gear system assembly with handle for charging discharging of VCBs complete all as specified and directed by Engr in charge.

5

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

2

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

3

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

3

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and all as directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

2

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to300 sqmm complete all as specified and all as directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

2

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

1

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

6

-

-

... More
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed. Make: DENSON, M-SEAL, BIRLA 3M, RAYCHEM, CABSEAL

1

-

-

... More
Supply and fixing in replacement of synthetic insulating rubber mat ISI marked of size 2 mtr x 1 x mtr x 8mm 33 KV / 11 KV at MRS 90 B Grid complete with all fitting complete all as specified and directed

6

-

-

... More
Supply and Fixing in repairs moving carbon rollers of existing size and make suitable for 2000 KVA AVR Unit as per existing make & model.

4

-

-

... More
Matrial and labour for repair to AVR of capacity 2000 Kva outdoor type by opening the top cover and checking the oil level and top-up the same, tighening of connections, nut, bolts, gasket etc and refixing the same for proper functioning.

2

-

-

... More
Supply and fixing in repairs Tie & Tac brass connector suitable for 2000 KVA AVR Unit.

2

-

-

... More
Supply and fixing in repairs Chain rack (double) including bearing as per existing make & model.

2

-

-

... More
Supply and fixing in repairs Limit switch suitable for 2000 KVA AVR Unit as per existing make & model.

2

-

-

... More
Supply and fixing in repairs SS coupling suitable for 2000 KVA AVR Unit as per existing make & model.

2

-

-

... More
Supply and fixing in repairs Chain assembly suitable for 2000 KVA AVR Unit as per existing make & model.

2

-

-

... More
Tie & Tac/Chain rack/Limit switch/SS coupling/Chain assembly

2

-

-

... More
Supply and fixing in repairs Synchronous motor suitable for 2000 KVA AVR Unit as per existing make & model.

2

-

-

... More
Supply and fixing in repairs PCB card suitable for 2000 KVA AVR Unit as per existing make & model.

1

-

-

... More
Supply and fixing in repairs PT unit 11000/110 volts suitable for 2000 KVA buck booster Unit as per existing make & model.

1

-

-

... More
Supply and fixing in replacement of Winding temperature assembly complete suitable for 2000 KVA AVR Unit as per existing make & model.

2

-

-

... More
Supply and fixing in repairs Oil temperature relay complete suitable for 2000 KVA AVR Unit as per existing make & model.

3

-

-

... More
Supply and fixing in repairs Buchloz relay assembly complete suitable for 2000 KVA AVR Unit/ Transformer as per existing make & model.

2

-

-

... More
Supply and fixing in repairs Aux contactor suitable for 2000 KVA AVR Unit as per existing make & model.

1

-

-

... More
Material and labour for preparation of old painted surface of HT 33 KV MRS at 90 B Grid consisting of steel pole/power transformers,VCBs cross arm, GOD , pipe , clamp, chain link fencing etc having any description and applying one caot of aluminium paint by compressor gun complete all as specified and directed. Note : (a) The rate shall be inclusive of painting all minor items as clamps , brackets, nut, bolt and washer which is not particularly mentioned in this item. (b) The painting work will be carried out during shutdown approved by JKPDD.

1

-

-

... More
Material and labour for repair to Power transformer 33 KV outdoor type of capacity 6.3 MVA after dismentling the transformer carefully opening the top cover of of transformer for inspection / repair draining out the transformer oil from the housing complete, removing the carbon / sludge deposit in transformer housing core, renewal / replacement of unservisiable rubber bushes and washer, replacement of tap changer motor winding and thimble , replacement of silica gel , replacement of top cover gaskit set including jointing with pasting material, replacement of worn out and bolt , replacement of unsv LT & HT bushes , keeping the coil in electric oven chamber for 48 hr to remove the moister content , replacement of temp gauage of oil and winding , painting of complete transformer body from outside and inside . Marking of MES/SM number etc, replacement of conservator tank glass, reinstalling the core and winding inside properly, marking th all connection with suitable copper lugs, refilling of dehydrated transformer oil including dedydration, reinstalling the top cover after cleaning and painting of housing, conservator tank , expulsion vent etc, Meggering the HT of transformer and testing complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of HT feeder pillar box outdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs all across the panel made of angle iron 50x50x5 mm of size 1.2 mtrx1 mtrx1 mtr with 3 Nos required length Aluminium bus bar of size 40x10mm or 400 Amps for 11 KV , 11 KV post Insulator 6 Nos duly drilled hole for HT Cable connection including front and rear side openable with locking arrangment suitable for 11 KV HT and provision for incoming and out going HT cable connection including painting with two coats of smoke gray synthetic enamels paint over a coat of red oxide primer complete and providing security fence XPM jally type of 2 mtr height from ground level square type all rounded 2.5 mtr length with 9nos angle iron of 25x25x5mm of hight 2.25mtr (2mtr above ground 0.25 mtr under ground) including necessary location gate of same XPM jally all as specified and directed . Note:- Feeder piller box shall be mounted on brick plate form built in PCC not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and XPM jally supported on 9 nos angle iron with concrete base.

2

-

-

... More
Material and labour for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65/100mm dia for 550 volts grade complete all as specifed and directed.

18

-

-

... More
Supply and fixing in repairs post top porcelain insulator vitreous brown with GI clamp, nuts, bolts etc suitable for 33000 Volts grade working pressure complete all as specifed and directed.

5

-

-

... More
Material and labour for replacement of Shackle Type insulator 33000V 100mm hight 115 mm dia same as per existing complete.

5

-

-

... More
Material and labour for replacement of analog type Winding temperature indicator,(33 KV 50-60 HZ, 110-220 V IP 65 temperature 0-160 degree) mild steel body and indicator for oil/ temperature for any type/size for power transformer all as specified and directed.

2

-

-

... More
Material and labour for replacement of analog type Oil level indicator, (33 KV 50-60 HZ, 110-220 V IP 65 temperature 0-160 degree) steel body and indicator for oil/ temperature or any type/size for power transformer all as specified and directed.

2

-

-

... More
Material and labour for replacement of Mog Magnetic oil level indicator,of aluminium body, industrial use of size 1500mm, temperature indication upto 30 DC , works on max pressure 4Kg/sqcm accuracy 95% complete for any type/size /capacity transformer all as specified and directed

1

-

-

... More
Material and labour for replacement of buchholz relay/gas operative relay (11KV) of existing size and shape all as specified and as directed

2

-

-

... More
Material and labour for charcoal dust/breeze to fill in existing earthing pit to recharge the pit.

105

-

-

... More
Material and labour for common salt to fill in existing earthing pit to recharge the pit .

100

-

-

... More
Supply and fixing in repair PVC control cables (copper) from AVR to C&R panel and VCB s panel comlete all as specified and directed.

-

-

-

... More
All as per item No 141 but size 2.5 sqmm 1100 volt

185

-

-

... More
All as per item No 141 but size 4.0 sqmm 1100 volt

90

-

-

... More
Supply, erect, Testing & Commissioning of numerical protection relay relay Model Micom P127, complete control wiring with material, Programming/setting/calibration including software of relays required and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay. Make- Schneider or Techno Commercially equivalent ABB/L&T/Semiens

3

-

-

... More
Supply, erect, Testing & Commissioning of numerical protection relay relay Model Micom P 122, complete control wiring with material, Programming/setting/calibration including software of relays required and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay. Make- Schneider or Techno Commercially equivalent ABB/L&T/Semiens

2

-

-

... More
Supply, erect, Testing & Commissioning of VAA Auxilary relay Alstom Model VAA11,22,33,21,3123 , 110V complete control wiring with material, Programming/setting/calibration including software of relays required and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay. Make- ALSTOM or eqiuvalent

1

-

-

... More
Supply and fixing wiring and commissioning including thormostate switch space heater 200w for VCB/SF6 breaker/RMU complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs Silica gel complete all as specified and directed.

80

-

-

... More
Material and labour for repair of microprocessor based over current and earth fault relay with highest element event recording & current scanning/display feature suitable for 30 V to 110 V AC/DC suitable for 11 KV VCBs panels/C&R panels/AVR panels complete all as specified and directed.

8

-

-

... More
Material and labour for repair of microprocessor based over current and earth fault relay with highest element event recording & current scanning/display feature suitable for 30 Vto 110 V AC/DC suitable for 33 KV VCBs panels complete all as specified and directed.

2

-

-

... More
Supply and fixing of breaker control switch for 11 KV breakers.

3

-

-

... More
Supply and fixing of Auxiliary spring set as per sample.

2

-

-

... More
Supply and fixing of Vacuum interrupter type WL3379M3.

3

-

-

... More
Supply and fixing of rachet assembly buterfly as per sample.

2

-

-

... More
Material and labour for repair of UPS 5.0 KVA capacity single Phase 72 Volt. of Microtek.

1

-

-

... More
Material and labour for repair of copper wounded battery charger input voltage120 Volts to 240 Volts , output voltage 36 Volt along with protection DC MCB on DC side for reverse polarity, AC MCB on AC side,inbuilt stabiliser and fault indicator.

1

-

-

... More
Material and labour for taking out of inclind HT pole & repairing and refixing the same including excavation, removal, PCC foundation complete all as specified and as directed by Engr-in-charge.

35

-

-

... More
Material and labour for painting of steel tubular poles (perimeter) approximately 9.5 meter above GL in height including cross arms and bracings with two coat of aluminium paint painting paint incl numbering of the pole complete all as specified and directed.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.