Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Dec 2024
Closing Date16 Jan 2025
Tender Amount₹ 44,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing surplus soil to a distance not exceeding 50 meter and sepositing where directed at a level not exceeding 1.5 meter above the starting point ,complete all as specified and directed by the Engr-in-Charge.

80

-

-

... More
Supply and laying new dry sand or Dry coarse sand as cushioning to cable 8 cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and coverning complete all as specified and directed by the Engr-in-Charge. Note:- Punned quntity will be measured and paid at this item.

49

-

-

... More
Supply and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peack, size 300mm x 180mm x 40 mm inluding taking down old UNSV cable cover complete all as specified and directed by Engineer-in-Charge.

3500

-

-

... More
M&L for GI tube light grade of size 80 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable, including taking down old, complete all as specified and directed.

20

-

-

... More
M&L for GI tube light grade of size 100 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cableincluding taking down old, complete all as specified and directed.

20

-

-

... More
M&L for cutting of Road and Concrete surfaces upto 300 mm depth and 500 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.

40

-

-

... More
M&L Danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts and nuts of approved size, for HT, 25mmX20mmX 1.6mm size complete all as specified and directed.

15

-

-

... More
M&L for PCC 1:3:6 type C-2 with (using 40 mm graded crushed stone aggregate) as in foundation of pole /for ducting with necessary form work complete as specified and directed

1

-

-

... More
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole/ ducting including necessary form work complete all as specified and directed.

1

-

-

... More
S&F end joint kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sqmm including taking down old, complete all as specified and directed by Eng-in-Charge. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.

10

-

-

... More
S&F end jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm including taking down old complete all as specified and directed by Eng-in-Charge. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.

10

-

-

... More
S&F Arial bunched cable jointing kit for 11 KV grade cable for heat shrink straight through type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 Sqmm x 1 Core including taking down old. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.

15

-

-

... More
S&F Arial bunched cable jointing kit for 11 KV grade cable for heat shrink straight through type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 Sqmm x 1 Core including taking down old , complete all as specified and directed by Eng-in-Charge. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.

15

-

-

... More
S&F cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 Sqmm including taking down old, complete all as specified and directed by Eng-in-Charge. NOTE:- Item rate quoted including excavating/required T&P/Refixing & Refilling.

12

-

-

... More
S&F cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm including taking down old , complete all as specified and directed by Eng-in-Charge. NOTE:- Item rate quoted including excavating/required T&P/Refixing & Refilling.

8

-

-

... More
S&F cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 1 core XLPE ,armoured,AL conductor cable of size 120 to 150 sqmm including taking down old, complete all as specified and directed by Eng-in-Charge.

9

-

-

... More
S&F cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty ) 33000 volts grade with stranded aluminium conductor of size 150 sqmm 1 core complete ,all as specified and directed by Eng-in-Charge. Note :- Rate of under ground cables include excavation in trenches, sand cushioning/GI tubing light grade in lieu of sand cushioning, burnt brick as covering material and testing etc including taking down old

90

-

-

... More
Disconnecting and taking down old unserviceable cable of any description and capacity and M&L for on existing poles of Arial Bunched cable 11 KV grade, stranded and compact aluminium phase conductor of size 95 sqmm, 3 core and 70 sqmmx 1 core (bare messenger/conductor) with aluminium alloy. The phase conductor should be insulated with XLPE Sioplas compound as per IS:14225-1995 Part-II complete all as specified and directed by Engineer-in-Charge.Note :- The rated quoted shall be deemed to include the cost of fittings such as anchor clamps, suspension clamps, in line connectors, service clamps, insulation piercing connectors, tapping from bare lines etc. and nothing extra shall be admissible on this account, complete ,all as specified and directed by Eng-in-Charge.

250

-

-

... More
Disconnecting and taking down old unserviceable cable of any description and capacity and M&L for on existing poles of Arial Bunched cable 11 KV grade, stranded and compact aluminium phase conductor of size 120 sqmm, 3 core and 95 sqmmx 1 core (bare messenger/conductor) with aluminium alloy. The phase conductor should be insulated with XLPE Sioplas compound as per IS:14225-1995 Part-II complete all as specified and directed by Engineer-in-Charge.Note :- The rated quoted shall be deemed to include the cost of fittings such as anchor clamps, suspension clamps, in line connectors, service clamps, insulation piercing connectors, tapping from bare lines etc. and nothing extra shall be admissible on this account, complete ,all as specified and directed by Eng-in-Charge.

150

-

-

... More
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.

10

-

-

... More
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.

10

-

-

... More
Taking down and Re-laying of HT cable of any size after rectify the fault or Laying of XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core 95 Sqmm to 3 Core 185 Sqmm including jointing and testing, laid in trenches / ducts / pipe or on poles , complete all as specified and directed.

200

-

-

... More
Preparation of old painted surface and painting of steel tubular HT poles 11 mtr long from bottom to top incl all iron structure in Zebra pattern 30 cm wide, with synthentic enamelled paint in black and yellow colour up to 1.2 metre height from pedestal, including painting of steel structure, cross arms, bracings, supports, clamps and back plates (all metalic parts) of Steel Tubular pole complete, with two coats of Spray aluminium paint including preparation of old painted steel surfaces including writing in 80 mm wide letters/ numbers in both side of pole MES,LT/HT and pole No complete all as specified and directed by Engr-in-Charge.

25

-

-

... More
Disconnecting all existig electrical connection from four pole structure & taking out unserviceable/burnout HT Jumper cable/conductor with nut, bolt, washer and Supply & fixing PVC insulated sheathed unarmoured stranded aluminium single core cable for HT Jumper of length not less than 2.5 m long in repair /replacement on existing OH circuit/two Pole /four Pole Structure etc including ACSR Conductor (Weasel) using PG clamp/lugs, fastners, aluminium lugs, GI nut, bolt, washer etc complete as per site requirment, complete all as specified and directed by Engr-in-Charge by Engr-in-Charge.

20

-

-

... More
Restreching / tightening of HT over head line ( ACSR Conductor all 3 phases) of any type including opening out binding wire from pin/disc insulator and rebinding the conductor with insulator by 14 SWG binding wire complete all as directed by Engr-in-Charge. Note :- Three runs of ACSR conductor i.e one for each phase shall be considered as one unit length.

600

-

-

... More
Restreching / tightening of existing Aerial Bunched cable of any size and make on HT Poles complete all as specified and directed by Engr-in-Charge. Note :- The contractor shall also replace any broken/unserviceable fitting viz , Anchor clamps, Suspension Clamps, one line connectors, Dead End Clamps, Mid Span joints, HT Eye Hooks, service Clamps, insulation piercing connector etc all as specified and directed by Engr-in-Charge.

2000

-

-

... More
S&F in replacement pin type porcelain vitreous white, brown or green insulator including one galvanized spindle two GI washer and one GI nut 150 mm height, 150 mm dia for 11000 volts grade including taking down old UNSV pin type insulator complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement disc type porcelain vitreous white, brown or green insulator of 145 mm high and 255 mm dia ball and socket type,including one galvanized spindle two GI washer and one GI nut 150 mm height, 150 mm dia for 11000 volts grade including taking down old UNSV pin type insulator complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for concrete graded stone aggrgate using 40mm to 63 mm grade, loose filling around distribution transformer, yard, MRS transformer and GOD after scarification and stacking the existing aggregate, removing grass/wild in panels/eqpt & relaying new & old aggregate complete all as specified and directed by Engr-in-Charge. Note : The payment shall only be allowed for new aggregate brought and filling in the yard etc.

20

-

-

... More
M&L for repair to VCB/RMU switch gears (of existing capacity ) broken front and rear doors of existing size with suitable locking arrangements by using suitable hinges including necessary welding work complete all as specified and as directed by Engineer-in-charge.

20

-

-

... More
PCC Cable Route Indicators of size 600mm x 300mm x 50mm with letters inscribed on both sides as "MES HT CABLE" or "MES LT / HT CABLE" of specified font size not less 60mm as directed and mounted on PCC 450mm x 300mm x 300 mm complete using PCC 1:2:4 B-1(using 20mm crushed stone aggregate) and including painting with cement based paint complete all as specified and as directed by Engr-in-Charge.

50

-

-

... More
S&F in repair ,laying, jointing, testing and commissioning HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 120 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc. complete all as specified and as directed by Engr-in-Charge.

400

-

-

... More
S&F in repair, laying, jointing, testing and commissioning HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 95 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc.complete all as specified and as directed by Engr-in-Charge.

500

-

-

... More
Cleaning the sub station in side & out side building /fencing of transformer / two/ four structure and also incl around 2 m radious out side of fencing in every month duly taking down unwanted material/grass/vegetable roots/small tree/trimming of branches of tree inside and outside etc complete all as specified and directed.

2000

-

-

... More
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 (1 litre chemical and 3 litre water) for buring the grass complete all as specified and as directed by Engr-in-Charge.

3000

-

-

... More
M&L in repair for providing of male and female for GOD including servicing of GOD mounted on pole with cleaning the old grease properly and greasing of the GOD with new grease incl tighting of nut,bolt and washer of GOD easly , complete all as specified and as directed by Engr-in-Charge.

30

-

-

... More
S&F Electric shock chart dust proof, water proof in which written electric shock and its treatment which is written in English and hindi for Sub Stations complete and fixed with good quality wooden frame and mirror of size 50 x 75 cm, complete all as specified and as directed by Engr-in-Charge.

10

-

-

... More
S&F in repair, testing and commissioning of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators of rating up to 200 Amps complete with drop out fuse assy having fuses of rating 40 Amps and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including padlock complete all as specified and as directed by Engr-in-Charge.

5

-

-

... More
M&L for cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
S&F in repair of Lightning arresters expulsion type complete (Each Set -03 Nos ) with all fittings, transmission class, discharge capacity 65 kilo amp and hight current with stand 100 KA outdoor type for 11000 volts, including clamps, nuts and bolts, washers and connection to earth with 32 mm x 6 mm GI strip to Lightning arrester complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and errect steel tubular, swaged pole, 11 Mtr long type 410-SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts and screws duly painted with two coats anti corrosive paint internally complete and externally upto planting depth alternate black and yellow straps of synthetic enamel paint 30 cm each up to 1.5 mtr from GL and remaining pole painted with aluminium paint including writing No , complete all as specified and directed by Enge-in-Charge.

2

-

-

... More
M&L for using of Petrolium jelly on GOD after removing carbon, dust etc complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.

150

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 20x3 mm copper strip complete all as specified and directed by Enginer-in-Charge.

150

-

-

... More
Maintenance and complete servicing of 11 KV VCB Make: Crompton/Kirloskar/Alsthom or as existing. including disassembling of operating mechanism parts, well greasing of springs/repair of mechanical parts, spring charge assembly and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts, rewiring the control circuit/Lt circuit and components etc complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Note - (i) Replacing new items shall be measured and paid separately as supply only. The labour charges for fixing shall be included in this item. (ii) Minor items such as nut,bolt/pins and control internal wiring are included in the quoted rate. (iii) If any defect occurred at any place of AF Stn Udhampur, the contractor will provide machnic with in two hours for rectification of defects. If the contractor not provide the machanics and material for defective /UNSV schedule time, the amount will be deduct 2000/per day as penality treatment after receiving phone/massage/ what app /email etc complete as specified and directed. (iv) Other part which is not included but required for functioning of equipment i.e refelling of gas etc shall be included in the quoted rate.No extra payment will be made for the spare parts/relay.The contractor shall be arranged standby supply for testing of relays etc. (v)Taking out relay set (2 Nos over current & 01 No earth fault relay) of any make from HT11KV VCB/(SF6 type) panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (vi) Any other T & P required shall be included in the quoted rates.

-

-

-

... More
(a) Supply only in repair closing coil indoor type for 11 KV VCB in replacement as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
(b) Supply only in repair triping coil indoor type for 11 KV VCB in replacement as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
(c) Supply only in repair spring charging motor suitable for fixing with 11 KV indoor type VCB panel as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
(d) Supply only in repair digital volt meter/ammeter as per existing make/ model/capcity.

10

-

-

... More
(e) Supply only in repair indicator lamp as per existing make/model/capcity

10

-

-

... More
(f) Supply only in repair cast regin CT of ration 400/200/5/5A as per existing ratio/make/model/capacity

4

-

-

... More
(g) Supply only TnC switch (Tripping neutral & closing) as per existing make/model/capacity

2

-

-

... More
(h) Supply only in repair insulating gear charging handle as per existing make/model/size

2

-

-

... More
(j) Supply only in repair Power Pack units 230 volt AC, 7 Ah with battery back up 24 volt DC in sheet metal enclosure as per existing make/model/capacity

1

-

-

... More
Maintenance and servicing, tunning, caliberation and testing of RMU/SF6 gas filled circuit breaker/Isolator/remote panel of make:- Schnieder-electric including checking of all electrical wiring, disassembling of operating mechanism parts, well cleaning, replacing unserviceable parts and accessories, oiling/greasing of moving parts including reassembling, proper setting of all mechanism, and making SF6 Breaker in perfect operational in manual and electrical mode including well cleaning the complete panel board, main bus bar coupler, decarbonizing all joints, bus bars coupler, CTs, PTs, spouts metal parts and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge.

20

-

-

... More
Note: (i) Replacing new items shall be measured and paid separately as supply only.The labour charges deemed to be included in the unit rate quoted for this item. (ii) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer/service centre. (iii) If any defect occurred at any place of AF Stn Udhampur, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanic and material for defective/UNSV schedule time, the amount will be deduct 1000/day as penality treatmen after receiving phone/message/ whatsapp /email etc complete all as specified and directed. (iv) Other part which is not included but required for functioning of equipment is included in the quoated rate & The contractor shall arrange for the standby supply for testing of relays etc. (v) Any set of LBS, Bus Coupler, SF6 Breaker etc in single RMU Unit shall be considered one item. (vi) Spare parts will be measured and paid seperately as supply only under respective items.

-

-

-

... More
(a) S &F in repair spring charging motor (230 Volt AC) suitable for RMU 11 KV as per existing make/model/capacity

2

-

-

... More
(b) S &F in repair digital multifunction meter as per existing make/ model/capcity

5

-

-

... More
(c) S &F in repair digital indicator lamp for breaker ON/OFF/Trip/Breaker spring charged/R-Y-B etc in 11 KV HT panel including associated wiring, if required complete all as per existing make/model/capcity all as specified and directed by Engr-in-Charge.

5

-

-

... More
(d) S &F in repair cast regin wound CT as per existing ratio/make/model/capacity

1

-

-

... More
(e) S &F in repair only cast regin wound PT as per existing make/model/ratio/capacity

1

-

-

... More
(f) S &F in repair locking arrangement handle for RMU as per existing make/model

4

-

-

... More
(g) S &F in repair Voltage presence indicator as per existing make/model

4

-

-

... More
(h) S &F in repair battery 12 VDC, 12 AH of relay as per existing make/model

10

-

-

... More
(j) Refilling of SF6 gas with gas Cylinder with appropiate hoses and fittings to connect the SF6 gas source ensure all connections are secure and leak free all as specified and directed.

25

-

-

... More
Disconnecting and taking out the unserviceable battery from battery bank any capacity supply and fix new lead acid maintenance free battery 2 volt 100 AH or as per existing make/model/capacity including connecting of all battery in battery bank and testing upto satisfaction of engineer - in-charge complete as specified and directed

30

-

-

... More
S&F of 11 KV HT Bus bar, Outdoor type, suitable for 11000 Volts, AC 3 Phase supply, 400 Amps, Unit fabricated out of 3.15 mm steel or MS steel enclosure suitable with MS Base Channel. The panel contains the equipments & components complete with copper bus bar interconnections, designation labels caution notices and pad locking facilities wherever required. The size of the bus bar not less than 1200x1000x800 mm to accommodate the incoming and outgoing cable connections with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated. The cubicle shall have frame work, bottom & 50 Cm long four legs of size 50 x 50 x 6 mm Angle iron. The panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above the ground and 60 cm below the ground level. The panels is finished with powder coated paint - Siemens Grey Ral 7032 and the panels is consisiting of following accessories :- (a) Copper Bus Bar 50 x 12 mm, suitable rating, 3 P, Air insulated with colour coded RYB Heat shrinkable sleeves (b) Earth bus 40 x 6 mm copper bus bar. (c) Danger Notice Board Note : 1.All civil work shall be included in the quoted rate. 2. drawing of HT bus bar shall be got approved from GE.

2

-

-

... More
S&F, laying cable duct cover of size 600 mm deep and 450 mm wide including MS sheet of 8 mm thick for protection of HT cable line in MRS or from outdoor Transformer /GOD to indoor VCBs of any size, complete as specified and directed

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.