Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Sep 2024
Closing DateCancelled
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down the old corroded / damaged HT Poles from the substation. Supply and fix steel tubular pole (12 m) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 complete all as specified & directed. Note : Necessary exacavation, foundation and coping is inclusive of rate quoted by contractor.

2

-

-

... More
Taking down the 33 KV circuit breaker from the system decarbonising the complete circuit system with CTC( carbon) Tetra chloride). Checking the complete moving / fixed contacts for any loose & retighney. The bus chamber should be inspected for loose joints.

4

-

-

... More
Panel side : 33 KV panel side the circuit sprouts / Bus sprouts has to be checked. Proper closing of sprouts to be checked. Any mechanical imbalance is found to be rectified. Proper DC system has to be checked for functioning indication system & tripping & closing system has to be properly checked and mentioned.

-

-

-

... More
Breaker side : The trowlley to be checked for mechanical fitment inside the chamber, Proper checking of tripping / closing system application of greasing to complete mechanison. Minor repair related to mechanism to be rectified. Are chector. SF-6 punty test to be done on intemptons to maintain dielectric properly of are quenching in breakers.

-

-

-

... More
Following routes test are to be peformed on breaker a) SF-6 gas leakage test. b) Tightness test. c) Design/Visuel test. d) Mechanical operaton test. e) Measurement of resistance of main circuit(or) contract resistant test. f) Dielectric test on auxialry circut & control circut. g) Power freqing over voltage with starter test.

-

-

-

... More
Taking down the 11 KV circuit breaker from the system decarbonising the complete circuit system with CTC( carbon) Tetra chloride) .Checking the complete moving/fixed contracts for any loose & retighney. The bus chamber should be inspected for loose joints.

15

-

-

... More
(a) Panel side: 11 KV panel side the circuit sprouts /Bus sprouts has to be checked. Proper closing of sprouts to be checked. Any mechanical imblance is found to be rectified. Proper DC system has to be checked for functioning indication system & tripping & closing system has to be properly checked and mentioned.

-

-

-

... More
(b) Breaker side: The trowlley to be checked for mechanical fitment inside the chamber, Proper checking of tripping/closing system application of greasing to complete mechanison. Minor repair related to mechanism to be rectified . Arc chutes. SF-6 punty test to be done on intemptons to maintain diclectric properly of are quenching in breakers.

-

-

-

... More
Servicing, repairing and overhauling of 33 KV isolator including cleaning of complete moving and fixed contracts oiling/ greasing operating mechanismtightening connections and replacement of unserviceable parts including reassembling the isolator after complete repair, routine and periodical testing complete all as specified and directed.

8

-

-

... More
S&F in repair fixed contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.

2

-

-

... More
S&F in repair moving contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.

2

-

-

... More
Complete draining out the transformer oil from radiators after closing the inlet valve from main body of 6.3 MVA power transformer including filling transformer oil of good quality having not less than 70 KV dielectric strength, having low viscosity all as specified and directed by Engr-in-Charge. Note: Oil as per IS 335 of 1983 all as specified and testing of Transformer after filling new oil upto 10 Hrs minimum as per entire satisfaciton complete all as specified and directed.

3100

-

-

... More
Dehydration & filtration of transformer oil in existing transformers installed at site with portable plant to improve the dielectric strength 70 KV including testing of dielectric strength after dehydration & filteration at site. Note:- (a) Pre-heated oil shall be topped up as required at site before the process; oil will be measured and paid seperately under respective item. (b) Qualified technician for filters of transformer shall be deputed. (c) Transforaton of filtrations from 132 KV sub station to 33 KV S/S is deemed to be included in rate quoted by Contractor.

18000

-

-

... More
S & F in replacement silica gel breathers assembly filled complete suitable for transformer cap 6.3 MVA (As per Sample) complete all as specified and directed.

4

-

-

... More
S & F in replacement of current transformer CT Ratio 150/75/1-1A of 33 KV, 15VA, Core 1, class-0.5, STC 20 KA for 1 sec complete all as specified and directed.

2

-

-

... More
Supply & fixing testing and commissioning feeder protection and control relay for 33 kv VCB REF615,50,51 N, 46,49,95 measurement for 3I,I0,4DI+6DO, One Rear RJ 45 port for IEC-61850 protocol, draw out type with CT shorting feature. Graphical LCD display, uaux48-250VDC/100-240 VAC all as specied and directed by Engr-in-charge. Make:- ABB & L&T, Simens, Schneider or equqlent

2

-

-

... More
S & F of Chequr plates / GI sheet / cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. including taking down complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Pin insulator porcelain viterous brown including 01 galvanized M.S.spindle, two galvanised iron washers and one gal. iron nut suitable for HT 33000 Volts complete all as specified and directed.

15

-

-

... More
Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 33000 volts grade cross sectional area 185 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed.

150

-

-

... More
Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 120 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed.

200

-

-

... More
Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 150 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed.

180

-

-

... More
Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm complete all as specified and directed.

12

-

-

... More
Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm complete all as specified and directed.

5

-

-

... More
Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 Sqmm complete, all as specified and directed.

5

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.

10

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.

5

-

-

... More
Cable jointing kit for 33 KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm complete all as specified and directed.

1

-

-

... More
Supply and fixing lightning arresters for non linear resistance type for 33 KV normal discharge count 5 Amps and high current impulse withstand 65 Kilo Amps conforming to IS-3070 Part-I for OH line including bracket, clamps, nuts and washers. Including taking down old, complete all as specified and directed by Engineer -in-Charge.

6

-

-

... More
Supplying and fixing in repair/replacement of 33 KV HT out door type Gang operated rotating type, triple pole,mechanically operated Air Break Switch Volts rating, 400 Amp capacity, horizontal mounting, double break, mounted on insulation and steel frame, GI operating rod of suitable length to be worked from ground leve, complete as specified and as directed.

2

-

-

... More
Supplying and fixing in repair/replacement of 11 KV HT out door type Gang operated rotating type, triple pole,mechanically operated Air Break Switch Volts rating, 400 Amp capacity, horizontal mounting, double break, mounted on insulation and steel frame, GI operating rod of suitable length to be worked from ground level. including taking down old, complete as specified and as directed.

12

-

-

... More
M & L for providing earthing with Copper earth plate electrode 600 X 600 X 3.15 mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 20x3mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.

5

-

-

... More
S & F New 11 Kv Numerical relay. Necessary plug setting and injector shall be done. Taking down Old U/S Numerical relay system from HT Breakers 11 kv.Test report for the said calibration submit to Engr-In-Charge. Make - ASHIDA -ADR-141C/ABB/Schinder

8

-

-

... More
Taking down the Numerical relay system from HT Breakers (33kv or 11 kv). calibration shall be done by primary injector kit. Necessary plug setting and injector shall be done (wind) load. Test report for te said calibration

15

-

-

... More
Supply and fixing in repair/replacement of 11 KV HT VCB Tripping Coil. Taking down old U/S Tripping Coil from VCB complete all as specified and directed by Engineer-in-Charge

11

-

-

... More
Supply and fixing in repair/replacement of 11 KV HT VCB Closing Coil. Taking down old U/S Closing Coil from VCB complete all as specified and directed by Engineer-in-Charge.

11

-

-

... More
Supply and fixing in repair/replacement of 11 KV HT VCB Vaccum Interruptor. Taking down old U/S Vaccum Interpreator from VCB . complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Repairing of spring charge motor of 11 Kv VCB with all necessary required T&P and Tools etc all as specified and directed by Engineer-in-charge.

10

-

-

... More
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Supply and spreading stone aggregates of size 20mm evenly at outdoor 33/11 KV sub stations after removing uprooting of tiny trees, bushes, beeds, grass, elephant grass, removing poly bags, brick bats, stone pebbles and other debris etc complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Material and labour of ACSR conductor of requried size for over head lines on poles including streching, tightning of poles insulator with winding wire of suitable with insulator/streching of ACSR conductor all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Drain out 6.3 MVA Transformer oil complete & do proper welding and ensure that no leakage from the transformer is observed after welding or apply other tactics to stop the leakage complete as specified. A qualified team of technicians OEM shall conduct a thorough inspection which shall be consisting of all standard tests with reports for proper diagnosis of transformer and maintenance according to OEM's recommendations at site. Ensuring that protective devices, such as overload relays, temperature sensors shall function correctly.

1

-

-

... More
Taking down unserviceable ACSR conductor HT any typeand size all as directedby Engr-in-Charge.

4

-

-

... More
Taking down unserviceable Cross arm any typeand size all as directedby Engr-in-Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.