Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date20 Dec 2024
Closing Date17 Jan 2025
Tender Amount₹ 42,99,250 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down existing unserviceable distribution board, switch fuse unit, enclosure for MCB / DB (inclusive of MCBs of any type and capacity) and making good the disturbed surface all as specified and as directed.

1396

-

-

... More
Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed.

4450

-

-

... More
Taking down Electric meter any type including disconnection electrically and refixing the same at same or new location as directed and specified by the Engineer in charge.

50

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface including taking down old unserviceable submain wiring complete all as specified and as directed.

2200

-

-

... More
All as per Item No- 7 above but in casing N caping

750

-

-

... More
All as per item No- 7 but two single core 6 sq mm FRLS PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in existing surface/concealed conduit including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.

750

-

-

... More
All as per item No- 7 but in surface conduite with two single core 6 sq mm FRLS PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.

750

-

-

... More
S&F in repair factory made epoxy powder coated Distribution board vertical TPN 4 ways (TPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 160/250 Amp as incomer and SP/TP MCBs outgoing including taking down of existing of unserviceable DB, complete all as specified and confirming to IS : 8623.

49

-

-

... More
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 4 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing including taking down of existing of unserviceable DB, complete all as specified and confirming to IS : 8623.

10

-

-

... More
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 8 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing including taking down of existing of unserviceable DB, complete all as specified and confirming to IS : 8623.

45

-

-

... More
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing including taking down of existing of unserviceable DB, complete all as specified and confirming to IS : 8623.

43

-

-

... More
Supply and fix in replacement of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 25 KA 0f size 63 amp complete all as specified.

49

-

-

... More
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 40 Amps , 240 volts in proper position all as specified and as directed by the Engineer-in-Charge. (Make : Legrand , schneider Electric)

150

-

-

... More
Supply & fixing MCB Single Pole (SP) of capacity 6 to 40 amps , 240 volts in proper position all as specified and as directed .

1050

-

-

... More
Supply and fixing fully diffused recessed mounted luminaire 2'x2' LED 36Watt suitable for POP/Gypsum false ceiling complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed.

42

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point, 20 mm bore medium grade GI watering pipe, 15mm bore light grade GI protection pipe, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test on completion all as specified and as directed.

22

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 35 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed .

720

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 25 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed.

750

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 16 Sqmm 4 core with necessary cable lugs, including taking down unserviceable cable, complete all as specified and directed .

950

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 16 Sqmm 2 core with necessary cable lugs, including taking down unserviceable cable, complete all as specified and directed .

750

-

-

... More
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 10 Sqmm 2 core with necessary cable lugs, including taking down unserviceable cable, complete all as specified and directed .

750

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 125Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, Pole, 415 volts,50Hz,breaking capacity 36KA,rating 160Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 200Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 250Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 350Amp,complete as per OEM standard design,all as specified and as directed .

2

-

-

... More
M&L for GI pipe 80 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .

50

-

-

... More
M&L for GI pipe 50 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .

40

-

-

... More
M&L for GI pipe 40 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .

60

-

-

... More
M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 90 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.

80

-

-

... More
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 600 Amps rated high conductivity copper bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-

1

-

-

... More
(a) MCCB 400 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 250 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 08 Nos (outgoing) (c) Multifunctional meter Make-HPL (NEFVIFPE000)---01 Nos (d) Indicator lamp RYB :01 Set (e) CT'S 600/5 01 Set Make-Kappa

-

-

-

... More
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity copper bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-

12

-

-

... More
(a) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 12 Nos (outgoing) (c) Multifunctional meter Make-HPL (NEFVIFPE000)---01 Nos (d) Indicator lamp RYB :01 Set (e) CT'S 400/5 01 Set Make-Kappa

-

-

-

... More
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.

600

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed.

400

-

-

... More
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified.

200

-

-

... More
M&L for Sand cushioning to cable laid in tranches using clean, dry fine sand free from organic particle complete all as specified and as directed. Note :- Finished thickness of sand cushioning after punned down shall be considered for calculating the volume for payment.

220

-

-

... More
Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed

10000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.