Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date25 Sep 2024
Closing Date24 Oct 2024
Tender Amount₹ 47,70,000
Costs
EMD
₹ 95,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676603_1Bid Award Id
ViewTender No
864/WS-65/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Fixing only 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' type hook or cranked bolt and washers, in roof, wall etc complete all as specified and directed. Note: Old sheets obtained from dismantling shall be re-used.
340
-
-
... More
Dismantling wall, ceiling and floor boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
660
-
-
... More
S&F 9mm thick plywood, grade BWR, type BB, fixed with screws to timber frame-work in ceiling complete all as specified and directed.
480
-
-
... More
S&F 9mm thick plywood, grade BWR, type BB, fixed with screws to timber frame-work in wall complete all as specified and directed.
180
-
-
... More
Dismantling of timber scantlings 40 sq. cm and over in section, in any position unframed work complete all as specified.
10
-
-
... More
M&L for second class hard-wood in scantlings clean swan timber fixed complete all as specified.
8.5
-
-
... More
Fixing only second class hard-wood in scantling clean swan timber fixed complete all as specified and directed. Note: Old timber obtained from dismantling shall be re-used.
1.5
-
-
... More
Dismantling wooden boarding, any description, fixed in any position with nails all as specified and directed.
565
-
-
... More
S&F second class hard wood, 20mm thick, wooden boarding, planed one side with butt joints fixed with nails as in eaves board in any position complete all as specified and directed.
70
-
-
... More
S&F second class hard wood, 40mm thick wooden boarding, planed one side with butt joints fixed with nails as in floor and skirting complete all as specified and directed.
275
-
-
... More
Fixing only 20/40mm thick wooden boarding, planed one side with butt joints fixed with nails as in floor and skirting complete all as specified and directed. Note: Old boarding obtained from dismantling shall be re-used.
200
-
-
... More
S&F 20mm thick wooden boarding or planks, clean swan width n.exc 25cm fixed with nails as in eaves board/wall complete all as specified and directed.
20
-
-
... More
M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
265
-
-
... More
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of suitable primer over and including 1-2mm thick layer of wall putty to obtain even/smooth surface using sand paper complete all specified and directed.
445
-
-
... More
M&L for preparation of previously treated wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
150
-
-
... More
M&L for preparation of previously treated wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
300
-
-
... More
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
300
-
-
... More
M&L for preparation of previously treated steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint at any height complete all as specified and directed.
300
-
-
... More
S&F in replacement curtain rod 20mm dia mild steel, chromium plated fancy type with fixing brackets and knobs at both ends complete all as specified and directed.
80
-
-
... More
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
2.4
-
-
... More
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed.
16
-
-
... More
Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
925
-
-
... More
M & L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
900
-
-
... More
M & L for rendering 5mm thick in CM (1:3) on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
25
-
-
... More
M & L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:3) complete all as specified and directed.
32
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of suitable primer over and including 1-2mm thick layer of wall putty to obtain even/smooth surface using sand paper complete all specified and directed.
900
-
-
... More
M&L for preparation of old treated surfaces of wall and applying two coats of cement base paint white or tinted all as specified and directed.
350
-
-
... More
M & L for preparation of previously treated plastered surfaces of walls and applying two coats of oil bound distemper complete all specified and directed.
1100
-
-
... More
Demolition of plain cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
36.1
-
-
... More
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base/levelling course complete all as specified.
470
-
-
... More
M&L for coloured Non - skid Ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed in CM 1:6 complete all specified and directed.
300
-
-
... More
M&L for 20-25mm thick machine cut kota stone slab, as in floor, laid over and including cement screed base 15mm thick in CM 1:4, set and jointed in neat cement slurry and pointed with grey cement slurry mixed with pigment to match the shade of the slab rubbing and polishing complete all as specified and as directed.
175
-
-
... More
M&L for 100mm thick PCC 1:2:4, type B-2, using 40mm graded crushed stone aggregate as in foot path/hard standing finished even and fair complete all as specified and directed.
50
-
-
... More
M&L for Chequered cement concrete tiles 30cmx30cmx22-25mm thick, with white cement and pigments set, jointed in neat cement slurry in floors laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
50
-
-
... More
M&L for 75mm thick PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in plinth protection, finished concrete surfaces even and smooth without using extra cement and filling joints with bitumastic filling in proportion bitumen and coarse sand mixture. 1:2 complete all as specified and directed.
75
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
210
-
-
... More
M&L for 20-25mm thick machine cut kota stone slab, as in riser of steps, dado and pillar etc, fixed over and including cement screed base 10mm thick in CM 1:4, set and jointed in neat cement slurry and pointed with grey cement slurry mixed with pigment to match the shade of the slab rubbing and polishing complete all as specified and as directed.
10
-
-
... More
M&L for coloured glazed ceramic tiles on vertical surface as in dado, skirting etc of size 350x250x7mm/ 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile fixed over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
200
-
-
... More
Taking down chowkats or frame with shutters (without taking off shutters from frame) n.exc 1.5 sqm each and removing from site complete all as specified and directed.
12
-
-
... More
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
80
-
-
... More
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
23
-
-
... More
S & F butt hinges medium weight 100mm size cold rolled mild steel complete all as specified and directed.
48
-
-
... More
S & F 150mm size aluminium anodised barrel tower bolts of extruded section all as specified and directed.
32
-
-
... More
S&F 150mm size extruded aluminium handles fabricated type, anodised all as specified and directed.
32
-
-
... More
S&F 15mm bore tubes medium grade, galvanized with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
50
-
-
... More
S&F 20mm bore tubes medium grade, galvanized with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
30
-
-
... More
Lagging to pipes internal dia 15mm used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144Kg/cum conforming to IS-9842 provided with 0.01mm aluminium foil complete all specified and directed.
20
-
-
... More
Lagging to pipes internal dia 20mm used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144Kg/cum conforming to IS-9842 provided with 0.01mm aluminium foil complete all specified and directed.
30
-
-
... More
S&F in repairs brass chromium plated tubular towel rail 'D' type, 600mm long between flanges complete all as specified and directed.
4
-
-
... More
S&F in repair 15mm bore Bib taps, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified and directed.
16
-
-
... More
S&F in repair 15mm bore stop valves CP fancy type, screwed down, screwed for iron pipe or for unions complete all as specified and directed.
28
-
-
... More
S&F in repair vitreous china wash hand basin white, size 550 x 400mm (flat back) including CP pillar tap heavy duty, brackets cutting for and pinning in ends of brackets including 32mm bore waste fittings, brass, chromium plated and PVC waste pipe complete all as specified.
8
-
-
... More
S&F in repairs 15mm bore Brass CP single lever basin mixer with double action for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
8
-
-
... More
S&F in repair 600mm x 450mm mirror of selected quality glass mounded on 6mm thick building AC board or commercial plywood with PVC frame and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
8
-
-
... More
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
6.25
-
-
... More
M&L for rendering 15mm thick in CM (1:3) on faces of sunken portion mixed with and including water proofing compound Dr Fixit pidiproof LW+ or equivalent @ 200ml/50kg of cement and fixed 32mm GI spout pipe in each room complete all as specified and directed.
63
-
-
... More
M&L for applying two coats of flexible polymer water proofing coating 1.0mm thick (Dry film in two coats) using Dr Fixit pidifin 2K of M/s Pidilite Industries or equivalent including necessary pond testing for 48 hrs in sunken portion complete all as specified and directed.
63
-
-
... More
M&L for treatment to sunken slab complete all as specified and directed as under :- (a) Preparation of surfaces and applying one coat of bituminous primer @ 0.50 Ltr/sqm (b) Applying hot blown cutback bitumen @ 0.70 kg/sqm (c) Providing and laying APP membrane 3mm thick of weight not less than 3kg /sqm with min 15cm over lap
15
-
-
... More
M&L for PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in sunken floor finished even and fair complete all as specified and directed.
5
-
-
... More
M&L for 40mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub bas of floor of wc/bath/toilet finished even and smooth without using extra cement mixed with and including water proofing compound Dr Fixit pidiproof LW+ or equivalent @ 200ml/50kg of cement complete all as specified and directed.
50
-
-
... More
M&L for coloured Non - skid Ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed in CM 1:6 complete all specified and directed.
50
-
-
... More
S&F in repair of vitreous china squatting pan ‘Orissa pattern’ size 580 x 440 mm white with integral foot rest including replacement of ‘P’ or ‘S’ trap, lime concrete bedding and making good floor complete all as specified and directed.
12
-
-
... More
S&F in repair PVC valve less, symphonic action type low level flushing cistern, white with inlet ball valve, float handle, including brackets 10 ltr capacity including 32 mm PVC flush pipe complete all as specified and directed.
12
-
-
... More
S&F 450mm long (PVC connection) 15 mm bore with PTMT nut complete all as specified and directed.
28
-
-
... More
S&F in repair PVC (SWR) floor trap with grating including jointing with solvent cement 75mm bore outlet complete all as specified.
12
-
-
... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and directed.
75
-
-
... More
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
45
-
-
... More
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
30
-
-
... More
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
12
-
-
... More
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
3
-
-
... More
S&F 500 litres capacity rotational moulded polyethylene water storage tanks three layers (cylindrical vertical with closed top) hoisted and fixed in position including ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia all as specified in SSR Part-I including dismantling old unserviceable water tanks complete all as specified and directed.
6
-
-
... More
Taking down carefully existing old burn out/unserviceable copper/aluminium point wiring any type (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing old materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
334
-
-
... More
M&L for point wiring with PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 1.5 Sqmm (Nominal area) drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all connected fittings accessories including providing of modular type/size of pressed steel terminal sunken boxes 1.2 mm thick or PVC flush type box and dully fixed it concealed on wall or surface on wall and covered with suitable size of modular type back and face cover plate frame for housing/mounting of switches, sockets, regulators etc and also providing 1.5sqmm PVC insulated FRLS wire, 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as a continuous earth wire complete and including making good all disturbed surfaces to match the existing surface of wall/floor/ceiling etc. all as specified and directed for following:-
-
-
-
... More
One light/fan point controlled by one way switch 5 Amp
238
-
-
... More
One 3/5 pin socket outlet, 5 Amps on same board controlled by one way switch
32
-
-
... More
One 3/5 pin socket outlet point, 5 Amps on independent board controlled by one way switch
32
-
-
... More
All as per Sl item No.76 above but using single runs of PVC insulated FRLS wire, 1100volt grade with multistranded copper conductor wire of size 2.5 Sqmm (Nominal area) power point wiring system with controlled by one way switch fixed on independent board and also providing of 2.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as continuous earth wire complete all as specified and directed
32
-
-
... More
S&F modular type switch 5/6 Amps 220 Volts for one way switching system complete as specified and directed.
302
-
-
... More
S&F modular type socket 5/6 Amps 220 Volts, 3/5 pin complete as specified and directed.
64
-
-
... More
S&F modular type switch 15/16 Amps 220 Volts for one way switching system complete as specified and directed.
28
-
-
... More
S&F modular type socket 15/16 Amps 220 Volts, 5/6 pin complete as specified and directed.
28
-
-
... More
S&F ceiling rose three terminals type made out of polycarbonate , isolated body complete all as specified and directed.
154
-
-
... More
S & F angular/batten type shape lamp holder with PVC/ Polycarbonate insulated body, alongwith brass adaptor and back plate for housing of bulb complete all as specified and directed .
16
-
-
... More
S&F one/two modular type step type electronic fan regulator with hum free step alongwith speed control knob complete all as specified and as directed.
32
-
-
... More
S & F in replacement LED tube light fitting 1 x 20W/ 22W, 220V AC decorative box type with electronic driver, holder including LED tube light with having energy efficient including providing of suitable type of flat flexible cable for electric connection complete all as specified and directed.
108
-
-
... More
S & F in replacement LED mirror light fitting with high output diffuser 2' long, 1x10W, 220V AC decorative type with electronic driver, holder including LED lamp with having energy efficient including providing of suitable type of flat flexible cable for electric connection complete all as specified and directed.
8
-
-
... More
S&F in replacement recessed / ceiling concealed mounted down lighter light fitting of round/square flat shape decorative type with high efficiency PMMA diffuser soft glare free light with driver & LED luminaire with rating capacity 15W, 220 volt AC complete set including making extra corner cutting in existing hole of ceiling and fixing the fitting by providing of suitable type flat flexible two/three core cable for electric connection complete all as specified and as directed.
56
-
-
... More
S&F surface mounted LED bulk head luminaries light fitting of rated capacity 10W including LED lamp & driver, out door type with dust and water proof, energy efficient for ready to use and required in both warm/white type colour fixture complete including dully fixed on bldg wall surface including providing of suitable type of flat flexible two/three core cable and making electric connection and including taking down of old fitting all as specified and directed.
8
-
-
... More
S & F environmental friendly LED street light fitting of rated capacity 35W 230 volt AC with having LED driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, out door type, having IP 65/66 protection made out of high pressure die cast hosing with heat resistant glass complete light fitting set including providing of suitable dia or as recommended by manufacturer GI pipe light grade bracket and it to match/setting the new fitting fixture hole attachment system of suitable bracket length make to shape / bend including duly fixed alongwith existing pole /bldg wall/ roof with the help of 02 Nos of MS fixing clamp alongwith nut bolt and including providing of suitable type of flat flexible two/three core cable and making electric connection and including taking down of old fitting all as specified and directed.
6
-
-
... More
S & F in replacement sheet metal enclosure duly powder coated with double pole and neutral enclosure with having a two pin and earth plug socket base & metal plug top and having mounting channel with one MCB SPN 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface all as required at site complete all as specified and as directed.
4
-
-
... More
S&F in replacement sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangement system suitable of rating of size/type for vertical type distribution board vertical load line type of rating VTPN 4 way type 415volt, 3 phase AC supply holding system with IP protection rating with ISI marked and having fitted neutral and earth link bus bar and mounting base channel and blanking plates suitable for holding of main MCCB as incomer and outgoing MCB complete system alongwith providing and mounting in side of DB box 01 Nos MCCB TP 160 Amps with breaking capacity 25 KA having adjustable setting & adjustable magnetic type and also providing of 8 Nos MCB SP 63Amps 10 KA 'C' curve same as per make of distribution board and also making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface complete all as specified and as directed.
2
-
-
... More
S&F in replacement sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangement system suitable of rating of size/type of distribution board of rating SPN 12 way type 220 volt AC supply system with IP-43 protection rating and having neutral and earth link bus bar mounting base channel for holding MCBs incomer and outgoing complete set and also making all necessary electrical connection and dully fixed surface on wall or concealed in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface complete all as specified and as directed.
8
-
-
... More
All as per Sl item No. 92 above but SPN 8 Way complete all as specified and as directed.
8
-
-
... More
S&F MCB SPN 40 to 63 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
19
-
-
... More
S&F MCB SP 6 to 32 Amps, 240 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
124
-
-
... More
M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 2x10Sqmm and one run of 1x10 Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old sub main wiring and making good the disturbed wall surface complete all as specified and as directed. Note:- 3 runs of 10sqmm wire and one run of PVC casing capping/conduit shall be measured and 1.0 RM.
80
-
-
... More
M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 2x6Sqmm and one run of 1x6 Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall and making electrical connection including taking down old sub main wiring complete all as specified and as directed. Note:- 3 runs of 6sqmm wire and one run of PVC casing capping/conduit shall be measured and 1.0 RM.
130
-
-
... More
Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 70 sqmm 3.5 core including laid in trenches or fixing on poles or passing through pipes complete including taking out of old unserviceable cable any type any size complete all as specified and directed.
50
-
-
... More
Excavation in trenches/under road/PCC path/ hard standing not exc. 1.5 m wide and n. exc. 1.5m depth for laying cable/pipe etc in soft/loose soil and getting out complete all as specified and directed.
13
-
-
... More
M&L for sand cushioning for under ground cable provided with a layers of sand before laying cable and sand after laying and stretching the cable complete all as specified and directed.(Punned thickness shall be measured)
5
-
-
... More
M&L for brick covering width equal to length of brick for mechanical protection to cable with well burnt sub class 'B' bricks laid dry flat complete all as specified and directed.
350
-
-
... More
Returning filling in including, spreading, levelling and well ramming in layers not exceeds 25 cm thick in any type of soil complete all as specified and directed.
8
-
-
... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
5
-
-
... More
S&F ventilating exhaust fan made out of sturdy mild steel body complete with louvers and shutter, 300mm sweep suitable to work on 230 Volts 50 Hz, copper winding including making of suitable type /size of hole on wall and fixing compete with nut, bolt etc all as specified and directed.
4
-
-
... More
Supply and laying GI pipe 40mm bore medium grade with all fitting laid in trenches/ under road /floor/ pole/ wall for protection of cable including providing clamping arrangement for holding of pipe on pole/wall in proper size of clamps, nut bolt and washer etc complete all as specified and directed.
3
-
-
... More
M&L for earthing, complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI light grade pipe 20 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electrical plate No 03 of SSR-2009 Part-I and connecting to earth test point complete all as specified and directed.
2
-
-
... More
M&L for taking down carefully existing ceiling/exhaust fan and geyser any type and capacity and removing fan blade and body parts and cleaning all dust and filling cavities with filler material, oiling, greasing including painting fan with blade and geyser complete body by applying two coats of synthetic enamel paint and assemble the same alongwith all connecting & fixing accessories such as rubber reel, nut, bolt, washer, lock pin, clamp etc and hanging and refixing the same in position with providing nut, bolt and washer etc and making electric connection complete all as specified and directed.
32
-
-
... More
S&F rigid non metallic PVC conduit of 20/25mm bore heavy duty with fittings laid in trenches/ fixed to wall with providing clamping arrangement for holding of pipe on wall in proper size of clamps, nut, bolt and washer complete all as specified and directed.
5
-
-
... More
Supply, fixing, commissioning and testing of three star rated dual inverter wall mounted split AC invertor based type with cooling and heating function and digital inverter type complete set of hi wall split type indoor and outdoor complete set of air conditioner unit with cordless remote control and full filling of initial refrigerant gas along with having in built heating and cooling arrangement and digital invertor twin rotary of rating capacity 2.0 TR and suitable for operation for 230 Volt 50Hz single phase electric supply including providing of MS stand & bracket for fixing of outdoor unit and indoor unit system and also providing of both type/size of suction and discharge copper refrigerant piping attachment system of any lengthy and duly fixed both piping connected from outdoor unit to indoor unit system along with duly over lapped it by nitrile insulation, with insulation taping work and suitable drain pipe line system up to ground level for dropping out the water outside from evaporator unit and making electric connection with 3 core copper cable of suitable size and including making of hole on wall/ roof etc and after making good to all disturbed surface match to existing wall complete all as specified and directed.
6
-
-
... More
Supply, fixing, commissioning and testing of wall mounting hanging based automatic digital operation based voltage stabilizer with copper winding based unit of single phase naturally air cooled indoor type with having digital display and suitable for operation on single phase AC supply and with having designed voltage for input & output voltage 90 Volt to 230 Volt with accuracy + 2.5% and having low and high voltage cut low voltage cut off 90 (-) 5 volts high voltage cut off 230 V (+ 5) Volts along with start time delay system with time delay adjustable from 30 second to 1.5 minutes system complete unit set of rating capacity 5 KVA complete.
6
-
-
... More
Supply and fixing of sheet metal enclosure duly powder coated with single pole and neutral enclosure with having a two pin and earth plug & top and mounting channel alongwith one 01 MCB DP 20 Amp and dully fixed surface on wall or concealed in wall and making all necessary electrical connection complete all as specified and directed.
6
-
-
... More
Supply and fixing of sub main wiring system with PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size single core 2 run of 25 Sqmm and 1 run of 16 Sqmm FRLS wire (Nominal area) and drawn through in heavy duty PVC Casing capping/ PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed in wall or surface on wall all as per decision and direction by EIC including and making electrical connection of complete system all as specified and directed by EIC.
60
-
-
... More
Supply and fixing of sheet metal enclosure DB box duly powder coated & framing work with locking system and having double door fixing arrangement system suitable of size/type of distribution board of rating SPN 4 way type 220 volt AC supply system with IP protection rating with ISI marked and having neutral and earth link bus bar and mounting base channel suitable for holding MCBs incomer and outgoing system complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical complete all as specified and directed.
2
-
-
... More
Supply, fixing & jointing of heavy duty copper tubing suitable use for refrigerant gas for suction/discharge piping system as recommended and suitable using for AC complete with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.
10
-
-
... More
M&L for sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 2x6Sqmm and one run of 1x6 Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall and making electrical connection complete all as specified and as directed. Note:- 3 runs of 6sqmm wire and one run of PVC casing capping/conduit shall be measured and 1.0 RM.
60
-
-