Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date2 Dec 2024
Closing Date4 Jan 2025
Tender Amount₹ 49,48,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Description all as per serial item No 01 here-in-before but Suction tank/collection tank of 8000 gallons at Jib water point alongwith the capacity of the tank, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 01 here-in-before but Suction tank/collection tank of 50000 gallons at Golf Course alongwith the capacity of the tank, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from the clear water under ground sump cap 5 lakh gallon dewatering through drain out channel/ pipe with valve/by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade/scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proofing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash in inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance 50 to 100 meters and depositing where directed as and when on requirement basis and writing date of cleaning with paint in capital letters of 80mm stencil alongwith capacity of the tank at MH Filtration plant area complete all as specified and directed by Engr-in-charge alongwith the capacity of the tank, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but clear water sump of 200000 gallons capacity at MH filttration plant area, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but clear water sump of 150000 gallons capacity at Tawi filtration plant area, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but clear water sump of 150000 gallons capacity at MH filtration plant area, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but Rectangular clear water sump of 100000 gallons capacity having 2 partitions at Tawi filter and Jib filter plant, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Rectangular clear water sump of 50000 gallons at Jib filter point, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Semi U/G clear water sump of 100000 gallons at Jib filter point, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Semi U/G clear water sump of 2 lakh gallons capacity at CHNC, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but Semi U/G clear water sump of 60000 gallons capacity at Sansar Chand Vihar, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Circular U/G clear water storage tank of capacity 3.00 lakh gallons at 'B' Res area, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but Rectangular underground clear water storage tank of capacity 50000 gallons at 'B' Reservior, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but underground sump rectangular clear water storage tank of capatiy 25000 gallons at 15 FAD, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Circular clear water storage tank of capacity 50000 gallons at 15 FAD, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC reservoirs of capacity of 50000 gallons underground sump at MPH area, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC under ground sump of capacity 4625 gallons at NSOI area, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC under ground sump of capacity 10000 gallons at `A' Mess, MPH area, Taramount Kutir House, Ashok Vihar, Chinar PH (02 Nos), complete all as specified and directed by Engr-in-Charge.

7

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC under ground sump of capacity 50000 gallons at NCSR area, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Description all as per serial item No 06.00 here-in-before but Rectangular clear water sump of 50,000 gallons capacity at NCSR, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC under ground sump of capacity 100000 gallons at Bikram Enclve pump house, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but Rectangular clear water sump of 1,00,000 gallons capacity having 2 partitions at Tawi filter, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Description all as per serial item No 06.00 here-in-before but of RCC under ground sump of capacity 2.0 gallons at Tawi filter & R centre, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of overhead tank 1.5 lakh gallons dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 50 meters and depositing where directed as and when on requirement basis and writing date of cleaning with paint capital letter of 80mm stencil at `A' Reserviour area alongwith the capacity of the tank, complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Description all as per serial item No 27 here-in-before but over Head tank of capacity 50000 gallons at following area Key personel Qtrs, 4 Para, Arty, 9 Para, Chibber Enclave(New and old) , 10 DOGRA, complete all as specified and directed by Engr-in-charge.

7

-

-

... More
Description all as per serial item No 27.00 here-in-before but Over head tank of capacity 30000 gallons at 10 Garwal area, complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Description all as per serial item No 27.00 here-in-before but Over head tank of capacity 75000 gallons at 54 Engr Regt and Krimchi complex, Ashok Vihar, R Centre, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Description all as per serial item No 27.00 here-in-before but Overhead tank of capaicty 50000 gallons at 874 'A' Coy, 14 EME, R Centre, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Description all as per serial item No 27.00 here-in-before but Overhead tank of capacity 25000 gallons at Tawi filter plant, complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Description all as per serial item No 27.00 here-in-before but Overhead tank of capacity 100000 gallons a JNE (5071 ASC Bn), complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Description all as per serial item No 27.00 here-in-before but of RCC reservoirs of capacity 50000 gallons of 12 mtr staging at PBE area, Taramount, CP colony, 'A' Mess, Bikram Enclave & Sapper Enclave, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Description all as per serial item No 27.00 here-in-before but of PVC/RCC tanks of capacity1000 Ltrs to 5000 Ltrs at PBE area, Taramount, CP colony, 'A' Mess, Bikram Enclave Station HQ,Krimachi area,Transit camp & Sapper Enclave, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
Taking out sludge/foreign material/silt/vegetation /mud from Hopper tank (size 5 x4 x 4.5 metre) capacity of 300000 gallons dewatering through drain out channel /pipe with valve /by using suitable pump set and removing residual water and cleaning the walls with the help of blade/scrapper/wire brush, using disinfectant, after clearing the drainage channel / pipe with valve and repairing cracks/depressions/ cavities by filling cement mortar in CM 1:3 mixed with liquid water proofing admixture after applying cement slurry @ 3Kg/SM mixed with liquid water proofing admixture to entire satisfaction of Engr-in-charge, preparation of old surface and applying one coat of lime wash on inner surface including filling of cracks with suitable plastering in CM 1:3 and best quality putty, including removing the sludge/silt/foreign material to a distance not exceeding 50 metres and depositing where directed as and when on requirement basis and writing date of cleaning with paint in capital letters of 80mm stencil complete all as specified at Tawi filter plant and directed by Engr-in-Charge.

1

-

-

... More
Taking out sludge/foreign material/silt/vegetation /mud from the clarifloculator tank circular type capacity 500000 gallon of size 16 metre dia and 4.0 metre depth dewatering the residual water and cleaning the side walls with help of blade/scrapper/wire brush, using disinfectant, after clearing the drainage channel / pipe with valve and repairing cracks/depressions/ cavities by filling cement mortar in CM 1:3 mixed with liquid water proofing admixture after applying cement slurry @ 3Kg/SM mixed with liquid water proofing admixture to entire satisfaction of Engr-in-charge,preparation of old surface and applying one coat of lime wash including removing the sludge/silt/foreign material to a distance not exceeding 50 metres and depositing where directed as and when on requirement basis at Tawi filter point,and 2xMH Filtration plant and writing date of cleaning with paint in capital letters of 80mm stencil, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Making of temporary bundth using existing material from river bed of length 40 mtrs (approx) width 2.20 meter (approx) of height 1.65 metrs in Tawi river at intake water point area for cleaning of Tawi low lift pump house of suction point to main stream of Tawi river running water flow diversion into suction point by removing all the silt, ballies, boulders and sand collected at suction point of Tawi low lift pump house (new and old) contractor shall provide be necessary sand bag with excavator, and labour, complete all as specified and directed by Engr-in-charge. Note: The rate quoted by contractor for this item includes:- (i) All the dirt/silt/vegetation removed by the contractor while cleaning will be dumped to a distance 50-60 metres out side the installation premises. (ii) Arrangement for the portable pump required for empting the Reservoirs at installation & other places will be made by the contractor.

1

-

-

... More
M&L for dewatering the musical fountain sump, cleaning with cleaning agents & metal wire brush, washing all sides of walls and floor including removing water, mud, silt, slash and foreign materials obtained while cleaning the sump including cleaning the nozzles by opening them and refixing them after cleaning to the entire satisfactionand, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L for dewatering the Old swimming pool of capacity 1.0 lakh gallons by using pump set and cleaning the internal surfaces with cleaning agents & wire brush and washing all sides of walls and floor using bleaching powder including removing water, mud silt, slush and foreign materials obtained while cleaning the pool including cleaning, scrapping and washing over flow drain on four sides for the entire satisfaction of Engr-in-Charge, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for dewatering the swimming pool (NSOI) of capacity 2.5 gallons by using pump set and cleaning the internal surfaces, ladder and channels with cleaning agents & wire brush and washing all sides of walls and floor using bleaching powder including removing water, mud silt, slush and foreign materials obtained while cleaning the pool including cleaning, scrapping and washing over flow drain on four sides for the entire satisfaction of Engr-in-Charge, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
M&L for replacement of heavy duty Chemical Dosing system suitable to inject solution upto 25 LPH working pressure 10 kg/cm² comprising of dosing pump fitted on service tank of capacity 100 ltrs for injecting calcium hypochlorite solution and connected with chlorine dosing preparation tank of cap 170 litres coupled with electric motor driven agitator with motor capacity 0.5 HP, 1440 rpm assembly , agitator with S S sweep blade duly FRP coated, complete unit including starter, complete all as specified and directed by Engr-in-charge. Make : Declibac/ Sathya Sai Aqua Pura Services/ Verito Engg Pvt Ltd

2

-

-

... More
S&F in replacement candle/filter media complete set for RO system of capacity 250 LPH, complete all as specified and directed by Engr-in-charge.

15

-

-

... More
S&F in replacement candle/filter media complete set for RO system of capacity 150 LPH, complete all as specified and directed by Engr-in-charge.

9

-

-

... More
S&F in replacement candle/filter media complete set for RO system of capacity 120 LPH, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement candle/filter media complete set for RO system of capacity 50 LPH, complete all as specified and directed by Engr-in-charge.

15

-

-

... More
S&F in replacement candle/filter media complete set for water purifire of capacity 3.5 LPH, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
S&F in replacement RO membrane complete set of RO system of capacity 250 LPH, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement RO membrane complete set for RO system of capacity 150 LPH, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement RO membrane complete set for RO system of capacity 120 LPH, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in replacement RO membrane complete set for RO system of capacity 50 LPH, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in replacement RO membrane complete set of water purifier of capacity 3.5 LPH, complete all as specified and directed by Engr-in-charge.

8

-

-

... More
S&F in replacement RO UV complete set for RO system of capacity 250 LPH, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement RO UV complete set for RO system of capacity 150 LPH, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in replacement RO UV complete set for RO system of capacity 120 LPH, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in replacement RO UV complete set for RO system of capacity 50 LPH, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in replacement RO UV complete set for water purifire of capacity 3.5 LPH, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in repair/ replacement RO pump for RO system of capacity 150 LPH to 250 LPH including motor winding, pump repair, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in replacement RO pump for RO system of capacity 3.5 to 120 LPH LPH, complete all as specified and directed by Engr-in-charge. Make: Aquaguard

5

-

-

... More
S&F in replacement SMPS adapter of RO system of capacity 120 LPH, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
S&F in replacement SMPS adapter of RO system of capacity 50 LPH, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S&F in replacement SMPS adapter of RO system of capacity 3.5 LPH, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&F in replacement of FRT, solenoid valve, water pipe of existing make & specifications for RO system, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
S&F in replacement of PVC 'T' junction, fittings of suitable RO of capacity upto 250 LPH of existing make & specifications, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Servicing of Aquaguard/RO/water purifier of cap 50 LPH to 250 LPH including washing of filter, taking out scaling etc refixing for reuse, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Servicing of Aquaguard/RO/water purifier of cap 3.5 LPH including washing of filter, taking out scaling etc refixing for reuse, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Taking out chlorine gas cylinder alongwith gases with proper safety equipments from Installations under GE(U) Udhampur (laying at site / connected with chlorination plant) and transport to the nearest chemical workshop for empity the chlorine gases from the cylinder and again deposited empty cylinder to MES store yard, complete all as specified and directed by Engr-in-Charge. Note : 1. It is intimated that safety equipments during taking out of chlorine gas cylinder for transportation is of contractor. 2. (Any) lifting of filled/ semifilled chlorine gas cylinder from the GE(U) Udhampur and its safe transportation to the neutralisation center/ workshop will be responsibility of contractor, any accident/ mishappening occured during the taking out / transportation of the cylinder, contractor will be responsible. 3. Certificate undertaking of empty cylinder from the workshop duly signed by contractor i.e. " No Chlorine Gas is residual in the Cylinder" may please be submitted.

15

-

-

... More
The following parameter are to be analysed for raw/treated water used for drinking purpose as per IS-TI-01/2010, complete all as specified and directed by Engr-in-Charge. (i). Turbidity,NTU,Max (ii). PH Valve (iii).E Coli,MPN/100 mli. (iv)Total hardness (as CaCO3) MG/L,Max (v). Iron (as Fe), mg/L, Max (vi). Magnesium (as Mg), mg/L, Max (vii). Sulphate (as SO4), mg/L, Max Note : Testing to be carried out at IIT/ NIT/CSIR/ Any NAPL Approved Lab

15

-

-

... More
Carrying samples for testing of treated water of STP (testing in NABL approved laboratory as approved by GE) and submission of detailed test report to the office of the Engr-in-charge, complete all as specified and directed by Engr-in-Charge. (a) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical, odour, PH Value TSS, BOD COD residual chlorine total nitogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms per 100 Ml (MPN) and E colilie in 100 ml Note - rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and from transportation charges for collection of sample (iii) testing to be done every 3 months or as and when directed by engr in charge.

8

-

-

... More
Labour for dismantling, disconnecting the Air Blower twin lobe positive displacement type of pressure upto 0.8Kg/cm2 and capacity upto 800 Cum/hr including disconnecting from chanel frame and electrical panel for repair of Gear Box, refitting of gear box after oiling, greasing, alingment of pump set and re-fixing/ assembling testing to make it functional complete inciuding cleaning of all dirt, dust etc, complete all as specified and directed by Engr-in-Charge including transportation to workshop for repair

2

-

-

... More
Supply and fixing in replacement following parts of Air blower twin lobe positive displacement type and pressure rating upto 0.8Kg/cm2, complete all as specified and directed by Engr-in-Charge.

-

-

-

... More
Replacement of Pully V Belt SPB-1800

2

-

-

... More
Ball Bearing 6311/C3 Make-SKF/ZKL

2

-

-

... More
Roller bearing 3213A

2

-

-

... More
Piston ring

2

-

-

... More
Oil seal

2

-

-

... More
Oil level glass

2

-

-

... More
Suction air filter

2

-

-

... More
Air compressor shaft werlding , turning , grinding

2

-

-

... More
Outer distance bush

2

-

-

... More
Pressure ring

2

-

-

... More
Asbestos graphite packing(casing cover)

2

-

-

... More
CI Belt Shaft Pulley

1

-

-

... More
Supply and fix B belt F-52 all as per existing as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply & pouring Compressor Oil in air blower at STPs, complete all as specified and directed by Engr-in-Charge. 460 Make : Castrol

100

-

-

... More
Disconnecting electric comnnections from LT control pannel and starter of Non clogging sub pump set at any size 2/3 HP and removing the pipe line connections from discharge side and taking out sub pump set alongwith, column pipe from Sewage sump with the help of chainpully including transportion to wksp for repair including replacement of rusted nuts bolts. rubber gasket, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement of following spare for Non clogging sub pump cap 2 HP to 3 HP, complete all as specified and directed by Engr-in-Charge.

-

-

-

... More
SS roter sleeve

4

-

-

... More
SS roter shaft ASS 410

2

-

-

... More
Water seal

4

-

-

... More
CI Lower Housing chamber

2

-

-

... More
CI upper housing chamber

2

-

-

... More
Connetion plate

5

-

-

... More
Remetaling of rotor & turning/grinding

2

-

-

... More
GM suction ring

4

-

-

... More
GM/CI Impeller

2

-

-

... More
SS stud with nut

12

-

-

... More
Impeller nut

2

-

-

... More
Impeller key

2

-

-

... More
Jointing of sub cable

4

-

-

... More
Painting of sub pump set with one coat of red oxide and two coat of synthetic enamel paint

4

-

-

... More
CI suction chamber

4

-

-

... More
Repairing of stamping of stator

2

-

-

... More
O ring set

2

-

-

... More
Ball bearing 6306-2Z Make- SKF/ZKL

4

-

-

... More
Roller Bearing 3308A Make-SKF/ZKL

2

-

-

... More
Roller Bearing NU 305 Make-SKF/ZKL

2

-

-

... More
Disconnecting electric comnnections from LT control pannel and starter of single/double stage pump of capacity 5HP/3HP/2HP and removing the pipe line connections from discharge & delivery side and taking out pump set including transportion to wksp for repair including replacement of rusted nuts bolts. rubber gasket, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F New parts for single/double stage pump of capacity 5HP/3HP/2HP as per manufacturer's composition of existing make of pump as below, complete all as specified and directed by Engr-in-Charge :-

-

-

-

... More
Pump impeller made out of CI Make : Kirloskar/Wilo Mather Platt or equivalent make as approved be GE.

4

-

-

... More
Pump shaft stainless steel shaft complete with check nut and keys

2

-

-

... More
Casing bearing

4

-

-

... More
Bearing housing

3

-

-

... More
Tyre coupling/star coupling

3

-

-

... More
Gland cup with nut and bolts

2

-

-

... More
Disconnecting electric connection of 10/15 HP motor, removing the UNSV motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same, complete all as specified and directed by Engr-in-Charge. Note: (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser item no 76.00 here-in-before but of capacity 5HP/3HP/2HP, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement following parts of Induction motor of capacity 10/15 HP of existing make, complete all as specified and directed by Engr-in-Charge:-

-

-

-

1

-

-

... More
Fan cover

1

-

-

... More
Endshield

2

-

-

... More
Terminal box

2

-

-

... More
Supply and fixing in replacement following parts of induction motor of capacity 5HP/3HP/2HP of existing make, complete all as specified and directed by Engr-in-Charge :-

-

-

-

1

-

-

... More
Fan cover

1

-

-

... More
Endshield

2

-

-

... More
Terminal box

2

-

-

... More
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 2/3/10/15 HP as per existing with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time, complete all as specified and directed by Engr-in-Charge. Note:- Cost of labour for winding deemed to be included in the rate quoted.

21

-

-

... More
Periodical cleaning of DMF and removing filter media, cleaning , drying and refixing as before with top up of fiter media if required, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Periodical cleaning of ACF and removing filter media, cleaning , drying and refixing as before with top up of fiter media if required, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Periodical cleaning of tube shelter and cleaning , drying and refixing as before, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
M & L for cleaning of Moving Bed Bio Reactor(MBBR) tank of storage capacity upto 200000 to 300000 Ltrs and all drain thoroughly by removing mud, grits etc from tank complete all as required at site and directed by the Engineer-in-Charge by following method :- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed by engr-in charge (b) Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
M & L for cleaning of Sludge Drying Beds by removing mud, grits etc from beds complete all as required at site and directed by the Engineer-in-Charge by following method :- (a) Cleaning inner surface of bed complete by removing mud and sludge collected inside the bed manually at a distance not exceeding 50 mtr all as directed by engr-in charge (b) Washing with clean water and bleaching powder mixture throughly complete bed internally and removel of left out sludge if any at site at a distance not exceeding 50mtr, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
M & L for cleaning of chlorine contact tank , filter feed tank and treated water tank all drain thoroughly by removing mud, grits etc from tank complete all as required at site and directed by the Engineer-in-Charge by following method :- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed by engr-in charge (b) Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
M&L for repaire of Hypo dosing pump of discharge cap 0-6 LPH, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement following parts of LT Panel & Starter, complete all as specified and directed by Engr-in-Charge.

-

-

-

... More
MCCB 100 Amp 4 Pole 36 KA

1

-

-

... More
Contactor 3 pole with AC coil AC-3 duty rating at 415 Volts 50 Hz, frame size1 suitable for 3 HP to 15 HP pump set

1

-

-

... More
Relay 3A, 4 Pole, 240V AC

1

-

-

... More
Cyclic Timer

1

-

-

... More
Fusible combination starter disconnect switch

1

-

-

... More
Wiring single core 1 sqmm

10

-

-

... More
Indicating lamps RYB as per existing

9

-

-

... More
Selector switch for ON-Off as per existing

9

-

-

... More
Analog Voltmeter Range (0-500V)

1

-

-

... More
Analog Ampere meter (0-60A)

1

-

-

... More
S&F in replacement of MS stud bolts of existing size with nuts suitable for pumps and motors of various capacity installed at installations, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
S&F in replacement of grouting nuts and bolts of existing size suitable for pumps and motors foundation of various capacity installed at installations, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply & Fixing in replacement of CI butterfly valve PN 1.6 of following size/bore conforming to IS 13095, complete all as specified and directed by Engr-in-Charge. Make :- ADVANCE / KARTAR/ JOHNSON/ Zoloto

-

-

-

... More
125 mm bore

2

-

-

... More
100 mm bore

2

-

-

... More
80 mm dia

26

-

-

... More
65 mm dia

2

-

-

... More
40 mm dia

2

-

-

... More
Supply only PVC insulated, sheathed, Copper conductor flexible cable, 1100 volts grade Heavy Duty, cross sectional area 4 sqmm, Four core round flexible, complete all as specified and as directed by Engr-in-Charge.

60

-

-

... More
Supply only of PVC insulated sheathed copper conductor flexible cable 1100 volts grade heavy duty of size 35 sqmm nominal cross section area single core, complete all as specified and directed by Engr-in-Charge. Make of cable Polycab /Plaza /Grandlay.

60

-

-

... More
Supply only of PVC insulated sheathed unarmoured copper conductor flexible cable 1100 volts grade heavy duty of size 50 sqmm nominal cross section area single core, complete all as specified and directed by Engr-in-Charge. Make of cable Polycab /Plaza /Grandlay.

18

-

-

... More
Supply & laying of flexible pipe of 15/20 mm dia used for wiring purpose, complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
Supply & pouring Bio-Culture in aeration tank/MBBR tank at STPs, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply and mixing of Di Amonium Phospate fertilizer for developed bacteria in equilisation tank, MBBR 1 and MBBR 2 tanks of STP chamber, complete all as specified and directed by Engr-in-Charge. Make: IFFCO or equivalent make as specified by E-In-C Br

100

-

-

... More
S&F in replacement of auto air release valve of capacity 3HP, discharge 17.3 cum/hr, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in replacement of Pressure gauge with needle valve & bush of 100 mm dia having pressure range 0-7 Kg/sqcm, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in replacement of NRV (Sandwich type) of size 65 mm dia, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of overhead tank at MAP accns of cap 40,000 Ltr dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 250 meters and depositing where directed as and when on requirement basis, complete all as specified and directed by Engr-in-Charge. Note: Date of cleaning should be written in white colour with black background on tank after cleaning & rate of this should be included in quoted rate.

43

-

-

... More
M&L for brick/ stone masonary valve pit chamber of size 0.5 mtr x 0.5 mtr x 0.5 mtr internal dimention) with 3.15 mm thick MS cover including 50 x 50 x 6 mm angle iron frame with 100mm hinges embedded in coping with locking arrangement and painting the MS surfaces with two coat of redoxide primer & syntheatic enamel paint. The chamber shall be of PCC 1:4:8 type D2 40mm graded aggregate for foundation, brick work in cement mortar, 75mm PCC coping with PCC 1:3:6 type C1, 15 mm thick plastering in cement mortar 1:4 including necessary excavation, earth work and colour washing internally and externally surfaces, complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
M & L for painting of DMFs, ACFs, Pipelines of STPs, Header (naming of delivery lines of header with white colour) & sluice valve of Pump houses including surface preparation by scrapping with emery paper and painting with one coat of red oxide primer and two coats of synthetic enamel paint of existing colour of approved make to the satisfaction of Engr in Charge, complete all as specified and directed by Engr-in-Charge.

60

-

-

... More
S&F of Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.

35

-

-

... More
All as per ser item No 112.00 above here-in-before but upto 40 mm bore. complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
All as per ser item No 112.00 above here-in-before but upto 25 mm bore, complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
M&L for replacement of heavy duty Chemical Dosing system suitable to inject solution upto 25 LPH working pressure 10 kg/cm² comprising of dosing pump fitted on service tank of capacity 100 ltrs for injecting calcium hypochlorite solution and connected with chlorine dosing preparation tank of cap 170 litres coupled with electric motor driven agitator with motor capacity 0.5 HP, 1440 rpm assembly , agitator with S S sweep blade duly FRP coated, complete unit including starter, complete all as specified and directed by Engr-in-Charge. Make : Declibac/ Sathya Sai Aqua Pura Services/ Verito Engg Pvt Ltd

1

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of overhead tank at New MH of cap 50,000 Ltr dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 250 meters and depositing where directed as and when on requirement basis, complete all as specified and directed by Engr-in-Charge. Note: Date of cleaning should be written in white colour with black background on tank after cleaning & rate of this should be included in quoted rate.

5

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of UG sump at New MH of cap 6 Lakh Ltrs dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 250 meters and depositing where directed as and when on requirement basis, complete all as specified and directed by Engr-in-Charge. Note: Date of cleaning should be written in white colour with black background on tank after cleaning & rate of this should be included in quoted rate.

2

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of UG sump at New MH of cap 2.5 Lakh Ltrs dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 250 meters and depositing where directed as and when on requirement basis, complete all as specified and directed by Engr-in-Charge. Note: Date of cleaning should be written in white colour with black background on tank after cleaning & rate of this should be included in quoted rate.

1

-

-

... More
M&L for taking out sludge /foreign material/silt/ vegetation/mud from surface of UG sump at Naubat Ram Vihar PH of cap 1.25 Lakh ltr dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfectant after repairing cracks/ depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/ best quality putty after applying cement slurry @ 3kg/SM mixed with liquid water proffing admixture to entire statisfaction of Engr-in-Charge preparation of old surface and aplying one coat of lime wash on inner surface including removing the sludge/silt/foregin material by using suitable T&P/man power to a distance not exceeding 250 meters and depositing where directed as and when on requirement basis, complete all as specified and directed by Engr-in-Charge. Note: Date of cleaning should be written in white colour with black background on tank after cleaning & rate of this should be included in quoted rate.

1

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil, complete all as specified and directed by Engr-in-Charge.

49.98

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested, complete all as specified and directed by Engr-in-Charge.

44.18

-

-

... More
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.

5.79

-

-

... More
Taking up or down old unseviceable GI pipe of size 80 mm dia including all fittings, complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
All as per ser item No 123.00 here-in-before but of 50 mm dia, complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
Supply & fixing GI pipes of size 80 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc, complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
All as per ser item 125.00 here-in-before but of 50 mm dia, complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
Supply and fixing GI fittings medium grade ISI marked including, complete all as required at site and as directed by Engr-in-Charge :-

-

-

-

... More
Elbow 50mm

8

-

-

... More
Elbow 80mm

8

-

-

... More
Socket 50mm

14

-

-

... More
Socket 80mm

14

-

-

... More
Union 50mm

7

-

-

... More
Union 80mm

8

-

-

... More
M&L for cutting of existing road for crossing of MS/DI/CI/GI Pipes for laying of any size Pipes including necessary excavation and earth work including repairing the same as per existing with pre mix bituminous carpet, Width of trench shall be 0.45m & depth shall be upto 1.5m, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
M&L for cement concrete in foundations, filling and mass concrete. Type B2 1:2:4 (40 mm graded aggregate), complete all as specified and directed by Engr-in-Charge.

1.2

-

-

... More
Supply and laying DWC (Double wall corruguated) pipe 90/75 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engr-in-Charge.

60

-

-

... More
Supply and laying DWC coupler for pipe 90/75 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply only PVC insulated, sheathed, Copper conductor flexible cable, 1100 volts grade Heavy Duty, cross sectional area 70 sqmm, 3.5 core round flexible, complete all as specified and directed by Engr-in-Charge.

24

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.