Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,laying and spreading in layers dry clean river sand for cable cushioning with a layer of sand 8 Cm depth before laying & 15 cm depth after laying the cable punned down to a depth of 10 cm above the top of the cable.(punned thickness shall be measured and paid for)

122

-

-

... More
M& L for Old Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation all as directed by Eng in charge.

8089

-

-

... More
Supply & lay burnt bricks sub class 'B' in trenches for cable protection complete all as specified and directed by Engineer-in-Charge..

1754

-

-

... More
M & L for Laying connecting and testing of 1100 volts grade LT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty eletric power cable with aluminium conductor of size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/wall/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A'

-

-

-

... More
Cable of size 2 core 10 Sq mm

300

-

-

... More
Cable of size 4 core 10 Sq mm

600

-

-

... More
Cable of size 4 core 16 Sq mm

600

-

-

... More
Cable of size 4 core 25 Sq mm

600

-

-

... More
Cable of size 3.5 core 35 Sq mm

310

-

-

... More
Cable of size 3.5 core 50 Sq mm

250

-

-

... More
Cable of size 3.5 core 70 Sq mm

250

-

-

... More
Cable of size 3.5 core 95 Sq mm

200

-

-

... More
Cable of size 3.5 core 120 Sq mm

200

-

-

... More
S&F heat shrinkable Straight though jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 70 to 150 sqmm complete all as specified & directed

3

-

-

... More
S&F heat shrinkable outdoor termination cable jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 25 to 50 sqmm complete all as specified & directed

5

-

-

... More
All as per ser item No. 08.00 here in above but cross sectional area 70 to 150 0sqmm

5

-

-

... More
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.

800

-

-

... More
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.

800

-

-

... More
Material and labour for 80 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified & directed

18

-

-

... More
Material and labour for 50 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified & directed

18

-

-

... More
Material and labour for 40 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe complete all as specified & directed

18

-

-

... More
Material & Labour for cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts,washers,welding,bending,drilling of holes for bolts in any shape or size as indicated and applying two coats of aluminium paint over a coat of red oxide primer including dismantling of existing mild steel cross arm with clamps from LT poles of any height, place and position complete all as specified & directed

0.35

-

-

... More
Supply and fix and draw ACSR Weasel/Squirrelconductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed by Engr-in-Charge.

0.5

-

-

... More
Supply and fix LT Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised iron mild steel spindle two galvanised iron washers and one galvanised iron nuts, 100 mm height, 65 mm dia for conductor 1100 volts grade including dismantling of existing LT pin type insulator from HT poles of any height, place, and position.

5

-

-

... More
Supply and fix LT shackle type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of 90 mm dia, 75mm height including galavnised mild steel strips 31 x 3 mm size and 12 mm dia bolts, nuts, and washers on existing cross arms including dismantling of existing LT shackle type insulator from LT poles of any height place and position complete all as specified & directed

5

-

-

... More
Supply, fixing and erection truly in vertical position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00m long) complete in repairs all as specified.

5

-

-

... More
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays.

2

-

-

... More
Material and labour for PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge.

2

-

-

... More
Material and labour for PCC (1:3:6) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge.

2

-

-

... More
Material and labour for lightning arrester expulsion type high tension complete with all fittings transmission class discharge capacity 65 kilo amps suitable for 11 KV including necessary connections with Over head lines & earthing fixed on 2/4 pole structure, including dismantling the old unserviceable one complete all as specified & directed

2

-

-

... More
Material and labour for switch Air break gang operated Triple pole, mechanically operated mounted on insulator & steel frame with operating mechanisum worked from ground level for current rating upto 200 Amps 11000 Volts all with male & female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unserviceable switches vertical/horizontal mounted, including insulator & operating mechanisum for repair/replacement of broken/worn out components and insulators etc complete all as specified & directed.

3

-

-

... More
Material and labour for drop out fuse assembly expulsion type single pole for 11 KV, 100 amps capacity complete consisting of galvanised steel base plate fuse carrying brackets channels with post insulator, fuse carrier fiber glass tube with fuse eliment complete including dismantling the old unserviceable one complete all as specified & directed

1

-

-

... More
Repair, maintenance & overhauling of existing 11 KV A.B GOD switch of any type & size including cleaning of insulator,replacing male & female contacts (where as required),greasing & oiling to operating mechanisum,setting of contacts,renewals of connections etc all for smooth fuctioning of A.B GOD switch complete all as directed by Engineer- in- charge

3

-

-

... More
Restringing of existing LT over head line of ACSR conductor after opening of binding wire from insulator & bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire all including renewal of jumpers with providing alkathin pipe of approved quality of jumpers, reconnecting the service connection after removing the carban material complete all as directed by Engineer in Charge.

50

-

-

... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.

5

-

-

... More
All as per sl item No. 29above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No.29 & 30 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely

10

-

-

... More
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site complete all as specified & directed

30

-

-

... More
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge.

30

-

-

... More
Supply, installation and commissioning and testing of LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge Incoming:- (a) MCCB 4 pole, 630 Amp, 36 KA, 415 volts AC with adjustable thermal and magnetic setting- 01 Nos (b) Aluminium bus bar 600 Amp TPN - 04 Nos (c) Digital voltmeter 0-600 volts with selector switch - 01 No (d) Digital Amp meter 0-600 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set Outgoing:- (a) MCCB 3 pole, 315 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting - 01 Nos (b) MCCB 3 pole, 250 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting- 02 Nos (c) MCCB 3 pole, 40 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting- 02 Nos (01 Spare )

1

-

-

... More
Supply, installation and commissioning and testing of LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge Incoming:- (a) MCCB 4 pole, 250 Amp, 36 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 Nos (b) Aluminium bus bar 400 Amp TPN - 04 Nos (c) Digital voltmeter 0-400 volts with selector switch - 01 No (d) Digital Amp meter 0-400 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set Outgoing:- (a) MCCB 3 pole, 160 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting - 01 Nos (b) MCCB 3 pole, 100 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting- 02 Nos (c) MCCB 3 pole, 63 Amp, 25 KA, 415 volts AC with adjustable thermal and magnetic setting- 01 Nos

1

-

-

... More
Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.

12

-

-

... More
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 3 pole 125 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 3 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 3 pole 200 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed

2

-

-

... More
Supply & Fixing in replacement MCCB 3 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed.

2

-

-

... More
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.

3

-

-

... More
S & F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.

3

-

-

... More
S & F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.

3

-

-

... More
M & L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (Spray painting outside/inside surface) of the feeder pillar box / LT Panels Outdoor / Indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engineer in Charge. Base frame with Black enamel paint (Rate quoted shall deem to be included of Numbering of Panel/ Feeder pillar) complete all as specified.and directed by Engineer charge

10

-

-

... More
Taking down existing junction box and 'S & F junction box made from FRP sheet 2.00 mm thick readymade of size 400mm x 300mm x 200mm fixed to pole/Wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers complete all as specified.

5

-

-

... More
M & L for servicing of feeder pillar box/ LT Cubical Panel , after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items.

10

-

-

... More
Supply and fix aluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm

300

-

-

... More
Supply and fix aluminium lugs of any type / shape of capacity from 35 Sqmm to 95 Sqmm

500

-

-

... More
Supply and fix aluminium lugs of any type / shape of capacity from 120 Sqmm to 300 Sqmm

200

-

-

... More
Supply only GI Nuts, bolts, screws, washers of required sizes

20

-

-

... More
S&F Extension link four set for MCCB of cap 125/160 Amp. Make: Legrand / Havells / Standard / IndoAsian

6

-

-

... More
S&F Extension four link set for MCCB of cap 250 Amp. Make: Legrand / Havells / Standard / IndoAsian

6

-

-

... More
S&F Extension four link set for MCCB of cap 400 / 630 Amp. Make: Legrand / Havells / Standard / IndoAsian

6

-

-

... More
Taking down rusted portion of sheet of feeder pillar boxes, damaged hinges etc and supply and fix new hinges heavy duty type, MS sheet patch work by cutting, welding and fabricating at site as required not exceeding 0.5 Sqm , painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.

3

-

-

... More
S&F locking arrangement with aldrop bolt set complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified.

4

-

-

... More
Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc. Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge.(Note- Accessories/components required for replacement i.e Driver, Surge protection device shall be measured and paid separately under relative item of Sch 'A' ) Note : Contractor responsibility is to liase with the department concerned for LT supply shut down required to carry out the work & also ensure the safety of labour employed by giving them safety equipments like helmet, gloves, safety belt , discharge rod etc and nothing extra shall be permisissible in this account.

400

-

-

... More
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed by Eng in Charge

102

-

-

... More
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 72 to 100 W capacity complete all as specified and directed by Eng in Charge

123

-

-

... More
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed by Eng in Charge

75

-

-

... More
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed by Eng- in- Charge

70

-

-

... More
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed.

1

-

-

... More
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of 5 and CRI70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge . Make : HPL cat Part No HPLLEDSL9060E or equivalent in PS

10

-

-

... More
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of 5 and CRI70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge . Make: Make : HPL cat Part No HPLLEDSL6060E or equivalent in PS

20

-

-

... More
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge .

5

-

-

... More
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.

20

-

-

... More
Supply & Fix street light brackets fabricated out of medium grade GI pipe of 50 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as directed.

10

-

-

... More
S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 16 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified

6

-

-

... More
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 16 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified

15

-

-

... More
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 16 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified

20

-

-

... More
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 6 Sqmm & connecting to light fittings/tertminal boxes

600

-

-

... More
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 10 Sqmm & connecting to light fittings/tertminal boxes

670

-

-

... More
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective switch/socket/ceiling rose/holders/fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc. complete all as directed.

2200

-

-

... More
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs / MCB DBs/TPN/ TPN DBs any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc. complete all as directed.

600

-

-

... More
NOTE FOR ITEM NO 74 to 75 :-(a) All T & P/Stationeries and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily, as directed. (b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted item. However, major items such as switches, sockets, bell push, fan regulator etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after reciving, Rs 500/- per complaint will be penalised.

-

-

-

... More
Supply & Fix in replacement, switch piano flush type 5 Amps single pole one way complete,

350

-

-

... More
Supply & Fix in replacement, socket out let multipurpose suitable for 2/3 pin 5 amp flush type complete all as spd & directed

150

-

-

... More
Supply & Fix in replacement, switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.

350

-

-

... More
Supply & Fix in replacement, switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.

350

-

-

... More
Supply & Fix in replacement, ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete .

120

-

-

... More
Supply & Fix in replacement, Step type fan regulator 300 watt, 230 volts, 50 HZ, AC. Supply complete .

100

-

-

... More
Supply & Fix in replacement, Batten/angle type holder insulated body with back plate complete all as spd & directed.

150

-

-

... More
Supply & Fix in replacement, bell push piano type 5 Amps complete.

50

-

-

... More
Supply & Fix in replacement, electric bell ding dong 230 volt AC complete,

50

-

-

... More
Supply & Fix in replacement, Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 20 watt complete with all accessories 230V 50 Hz. complete all as spd & directed.

700

-

-

... More
Supply & Fix in replacement, baton integrated LED channel of 10W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 complete all as spd & directed.

50

-

-

... More
Supply & fix in replacement, white powder coated (warm / white / cool white) CRCA housing with LEDs 36W, 230 V, 50 Hz recess mounting LED 2 feet x 2 feet luminaries, Swamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size.

10

-

-

... More
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz . complete all as spd & directed.

50

-

-

... More
Supply and fixing of LED Inverter Batten 9 Watt 230V frequency 50/60 Hz back up to 4 to 6 Houses including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as spd & directed.

50

-

-

... More
Supply & fix in replacement LED bulb 9 watt complete all as specified and directed.

600

-

-

... More
Supply & fix in replacement, modular switch piano flush type, 6 amps, 230V AC,single pole, one way, all as directed by Engr-in-charge.

50

-

-

... More
Supply & fix in replacement, modular switch piano flush type, 6 amps, 230V AC,single pole, one way, all as directed by Engr-in-charge.

30

-

-

... More
Supply & fix in replacement, modular socket out let with shutter multipurpose suitable for 2 pin and 3 pin 6 amp flush type, all as directed by Engr-in-charge.

50

-

-

... More
Supply & fix in replacement, modular socket out let with shutter multipurpose suitable for 6 pin 16 amp, flush type completeall as directed by Engr-in-charge.

30

-

-

... More
Supply & fix in replacement, modular bell swith,6Amp, 220 V, single pole all as directed by Engr-in-charge.

5

-

-

... More
Supply & fix in replacement, Electronic modular fan regulator ,Two module, electronic,step type and connection complete,all as directed by Engr-in-charge.

20

-

-

... More
Supply & fix in replacement, MCB DP 32/40 Amps 10 KA 230 volts "C" series complete

60

-

-

... More
Supply in replacement, MCB single pole 6 to 32 Amps 10 KA 230 volts "C" series complete

300

-

-

... More
Supply & fix in replacement, MCB single pole 40 Amps 10 KA 230 volts "C" series complete

60

-

-

... More
Supply & fix in replacement, MCB TP/TPN 50 to 63 Amps 10 KA 230 volts "C" series complete.

30

-

-

... More
Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit, complete, all as specified.

220

-

-

... More
Taking down unserviceable MCB DB SPN with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.

10

-

-

... More
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.

5

-

-

... More
Taking down unserviceable sub main wiring including wooden batten/PVC conduit of any size, complete, all as specified and directed by Engr-In-Charge.

50

-

-

... More
M & L for Point wiring with PVC insulated, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into with and including PVC casing capping not less than 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed steel concealed terminal boxes of reqd size made out of 1.2 mm thick sheet covered with 2.8 mm thick plastic laminated bakalite (hylam) ISI marked sheet suitable for switches/sockets/regulators complete all as specified & directed for the following :-

-

-

-

... More
(a) One light/fan point /bell point controlled by one switch

100

-

-

... More
(b) One point for socket outlet 5 amp on independent board

70

-

-

... More
All as per item No 105 here in before but point wiring for one 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board

50

-

-

... More
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete all as spd & directed

2

-

-

... More
S&F sheet metal enclosure (VTPN) double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCB as incomer, 125 Amp, 4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site.

2

-

-

... More
S&F MCCB 125A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as spd & directed

2

-

-

... More
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sq mm as earth continuity conductor connected to commen earth and earth dolly complete all as spd & directed

300

-

-

... More
Disconnecting & Taking down unserviceable ceiling fan 1400/1200 mm sweep 230 v, AC supply, single phase from position for winding and refixing for the same after winding, necessary connection comple all as specified and directed . Note winding and including repairs measured separately.

700

-

-

... More
All as per item No 111 here-in-before but exhaust fan of size 450/380/300 /255mm sweep

80

-

-

... More
All as per item No 111 here-in-before but wall mounted fan size 450/400 mm sweep

20

-

-

... More
M&L for collecting unserviceable ceiling fans 1200mm sweep 230 v, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling , greesing & painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface of the fan with and including replacement of rusted /unserviceable nuts, bolts split pin rubber reel , machine screws, shaft etc including replacement of defective / unserviceable parts / spares as required reassembling the fan and testing complete deposinging the complete repaired fan to E/M store yard of GE Nagrota including transportation complete all as specified and derected.

600

-

-

... More
All as per item No 114 here-in-before but ceiling fan of size 1400 mm sweep

100

-

-

... More
M&L for collecting unserviceable exhaust fan 450mm sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the exhaust fan and taking out complete burnt winding from exhaust fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface replacement of rubber pads and depositing the exhaust fan to E/M store yard GE Nagrota including transportation and testing etc complete all as specified and derected.

20

-

-

... More
All as per item No 117 here-in-before but exhaust fan of size 380 mm sweep

20

-

-

... More
All as per item No 118 here-in-before but exhaust fan of size 300 mm sweep

20

-

-

... More
M&L for collecting unserviceable PVC exhaust fan 250/300 mm sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the exhaust fan and taking out complete burnt winding from PVC exhaust fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing and depositing the exhaust fan to E/M store yard GE Nagrota including transportation and testing etc complete all as specified and derected.

20

-

-

... More
M&L for collecting unserviceable wall mounted fan 450/400mm, sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the wall mounted fan and taking out complete burnt winding from wall mounted fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface replacement of rubber pads and depositing the wall mounted fan to E/M store yard GE Nagrota including transportation and testing etc complete all as specified and derected.

20

-

-

... More
Taking down carefully from position , ceiling fan 230 volts single phase 50 Hz 1400 mm sweep from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note ; necessary accessaries paid seperately here in after.

180

-

-

... More
All as per item No 121 here-in-before but ceiling fan of size 1200 mm sweep

180

-

-

... More
Taking down carefully exhaust fan 230 volts single phase 50 Hz 450 mm sweep from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note ; necessary accessaries paid seperately here in after

10

-

-

... More
All as per item No 123 here-in-before but exhaust fan of size 300/380 mm sweep

50

-

-

... More
Taking down carefully wall mounted fan 230 volts single phase 50 Hz 450 mm sweep from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note ; necessary accessaries paid seperately here in after.

20

-

-

... More
Supply & Fix in replacement of gun metal bush of required size suitable for ceiling fans and exhaut fans complete all as specified and directed Make SKF / NBC

200

-

-

... More
supply & Fix in replacement of hanger for ceiling fan 1200mm/ 1400 mm sweep with nuts, bolts, washers complete all as specified and directed.

300

-

-

... More
Supply & Fix in replacement of aluminium blades for ceiling fan 1200 mm sweep complete all as specified and directed

50

-

-

... More
Supply & Fix in replacement of aluminium blades for ceiling fan 1400 mm sweep complete all as specified and directed

30

-

-

... More
Supply & Fix in replacement of bearing suitable for ceiling fan of any size complete all as specified and directed

250

-

-

... More
Supply & Fix in replacement of bearing suitable for Exhaust fan/Air circulator/wall mounted fan of any size complete all as specified and directed

10

-

-

... More
M&L scrbbing and preparing the old painted surfaces of ceiling fan of size 1200/1400mm sweep Complete including blade painting the same with white duco paint and writing the MES Nos of the fans, 25mm with black synthetic enamel paint and including oiling greasing of any make complete all as specefied and directed.

100

-

-

... More
M&L scrubbing and preparing the old painted surfaces of exhaust fan of size 300/450mm sweep (Complete including blade painting the same with white duco paint and writing the MES Nos of the fans, 25mm with black synthetic enamel paint and including oiling greasing of any make complete all as specefied and directed.

20

-

-

... More
Supply & Fix canopy top and bottom for ceiling fans complete all a spcified and directed.

100

-

-

... More
S & F in repairs flexible twin core 23/0.0076 with copper conductor including connecting fan of any make complete all as specified and directed.

300

-

-

... More
S&F 250/300 mm long fan down rod with clamp heavy duty as required in replacement complete all as specified and directed.

50

-

-

... More
S&F exhaust fan frame made out of MS sheet of any make and size of exhaust fan with suitable size of nut bolt and washers complete all as specified and directed

10

-

-

... More
Material and labour for replacement of Unserviceable Louvers with new louvers of exhaust fan 450mm sweep complete all as specified and directed.

5

-

-

... More
Material and labour for replacement of Unserviceable Louvers with new louvers of exhaust fan /250300/380 mm sweep complete all as specified and directed.

15

-

-

... More
S&F in repairs oil filled condenser of 2.5 MFD capacity after removing existing unserviceable condenser from any situation complete all as specified and directed,

600

-

-

... More
All as per item No 66 here-in-before but condenser 4 MFD capacity

50

-

-

... More
Supply & fix blade suitable for wall mounted fan 400/450 mm sweep fan complete all as specified and directed

5

-

-

... More
Supply & fix in replacement for shackle assembly for c.fan complete all as specified and directed

100

-

-

... More
Taking down the water heater storage type of any make of any capacity. dismantling the water heater carefully from its position fixed on walls, reassembling the water heater after replacement of defective parts and reinstalling the water heaters to their original locations or as directed, commissioning and testing the water heater complete, all as directed by the Engr-in-charge. Note: Any material/part found unserviceable during servicing shall be replaced by the contractor and measured and paid separately under respective items.

50

-

-

... More
S&F in place of unsv PVC connection of any make with (ISI Mark) having10mm dia, 45 cm long with steel reinforcement suitable for hot water geyser outlet supply with 02 Nos of Unions/ cup shaped cover with washers all as directed by Engr-in-charge. Make- Prayag/Sona/Horizon.

20

-

-

... More
S&F in place of un PVC connection of any make with (ISI Mark) having 10mm dia, 45 cm long suitable for cold water geyser inlet with 02 Nos of Unions/ cup shaped PVC cover with washers all as directed by Engr-in-charge. .

20

-

-

... More
S&F in place of unserviceable inner tank of 25 litres capacity water heater storage type, tank made out of copper sheet of size 22SWG, MS collar with six/seven/eight/ nine holes for fitting the flange assembly with vent pipe of brass, 3 “ long, 15 mm dia, threaded, including MS sheet ring all as directed by Engr-in-Charge.

5

-

-

... More
All as per srl item 147 above but of 35/ 50 litres capacity.

3

-

-

... More
S&F in place of unserviceable inlet /outlet assembly of any make of geyser having six/seven/eight /nine hole suitable for Bathwell/ Bajaj / pearl water heater of capacity 25/50 litre all as directed by Engr-in Charge.

15

-

-

... More
S&F in place of unsv rubber gasket suitable for six/seven/eight/ nine hole assembly of suitable size of water heater of capacity 50/35/25 ltr.

15

-

-

... More
S&F in place of unsv 4'' long and 1/2'' dia Chrome plated bolt with suitable washers all as directed by Engr-in-Charge.

5

-

-

... More
S&F in place of insulating material (glass wool) suitable for 25/50 litres capacity water heater, all as directed by Engr-in-Charge.

5

-

-

... More
S&F in place of unsv split bottom cover (two pieces) suitable for water heater of any capacity duly painted, all as directed by Engr-in-Charge

10

-

-

... More
S&F in place of unsv neon indicating lamp, rectangular /round as required at site, all as directed by Engr-in-Charge.

25

-

-

... More
S&F in place of unsv heating element 1.5 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater .complete all as specified and directed .

45

-

-

... More
S&F in place of unsv heating element 2.0 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater. .complete all as specified and directed

25

-

-

... More
S&F in place of unsv heating element 1.5 KW, single phase, 230 volt with round base suitable for 25/50 Ltr water heater. .complete all as specified and directed

25

-

-

... More
S&F in place of thermostat switch range upto 80”C suitable for 25/50 ltrs cap water heater.complete all as specified and directed

20

-

-

... More
S&F in replacement of steel outer body 50 Ltrs capacity, any make complete all as specified and directed

1

-

-

... More
S&F in replacement of steel outer body 25/35 Ltrs capacity, any make complete all as specified and directed

6

-

-

... More
S&F in place of unserviceable plug top 3 pin 15 Amps. .complete all as specified and directed

45

-

-

... More
S&F in place of unserviceable safety nut for geyser of capacity 25/50 ltrs..complete all as specified and directed

25

-

-

... More
Painting to outer body of geyser of capacity 25/35/50 ltr with white synthetic enamel paint of approved make after preparation of surface including filling cavities with filler of all as directed by Engr-in-Charge.

25

-

-

... More
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.

5

-

-

... More
Material and Labour for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator & Deep Freezers :-

-

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity.

20

-

-

... More
Refrigerator of 165 to 310 ltrs capacity.

8

-

-

... More
Deep Freezers any capacity

3

-

-

... More
Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge.

-

-

-

... More
Water coolers of capacity up to 150 liters.

22

-

-

... More
Refrigerators of capacity 210 to 320 ltrs.

5

-

-

... More
Deep freezers 100 to 400 ltrs capacity.

2

-

-

... More
Supply and replace starting relay suitable for :- Make : as per exiting make

-

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity

15

-

-

... More
Refrigerator of 165 to 320 liters capacity.

15

-

-

... More
Deep freezers of 100 to 400 ltrs capacity.

3

-

-

... More
Supply and replace thermostats of :-Make : as per exiting make

-

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity.

15

-

-

... More
(b) Refrigerator of 165 to 320 ltrs capacity.

15

-

-

... More
(c) Deep freezers of 100 to 400 ltrs capacity.

2

-

-

... More
Supply and charging refrigerant gas R-22/R-134 (A) up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge

-

-

-

... More
Water cooler 40/80 ltr cooling cap.

10

-

-

... More
Water cooler 60/120 ltr cooling cap.

10

-

-

... More
Water cooler 150/150 ltrs cooling cap

10

-

-

... More
Deep freezers of any capacity.

8

-

-

... More
Refrigerators of any capacity.

10

-

-

... More
Supply and replace condenser coil unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. Make : as per exiting make

-

-

-

... More
Water coolers 40 to150 ltrs capacity.

15

-

-

... More
Refrigerator of 165 to 320 ltrs capacity.

5

-

-

... More
Deep freezers of 200 to 400 ltrs capacity.

2

-

-

... More
Supply & Fix Timer delay Relay assembly in replacement of unserviceable Relay assembly of any cap all as specified and directed by Engr-in Charge Make : as per exiting make

-

-

-

... More
(a) Water coolers 40 to150 ltrs capacity.

10

-

-

... More
(b) Refrigerator of 165 to 320 ltrs capacity.

5

-

-

... More
(c) Deep freezers of 200 to 400 ltrs capacity.

2

-

-

... More
Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.

10

-

-

... More
Supply and replace overload protector of :-Make : as per exiting make

-

-

-

... More
(a) Water coolers upto 150 ltrs cooling capacity.

15

-

-

... More
(b) Refrigarator upto 320 ltrs cooling capacity.

10

-

-

... More
(c) Deep freezers of upto 400 ltrs capacity.

2

-

-

... More
Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :-Make : as per exiting make

-

-

-

... More
(a) Water coolers of any make and cap 40 to 150 ltrs capacity.

15

-

-

... More
(b) Deep freezers of any make & cap 100 to 400 ltrs capacity.

2

-

-

... More
Supply and replace capacitors of the following capacities for Acs

-

-

-

... More
3.15 ,4 & 6 Mfd

30

-

-

... More
10 Mfd

10

-

-

... More
40/60 Mfd

20

-

-

... More
50+6 Mfd Seven Pin

10

-

-

... More
Taking down existing unserviceable fan motor assembly complete with blades mounting frame leg with rubber bush from desert coolers and S&F Fan motor assembly complete with blades, mounting frames legs with rubber bush for desert cooler of capacity 4000/5000/6000 cum/hrs and testing complete all as specified and as directed.

77

-

-

... More
Supply & Fix Replacement of water circulation submersible pump of desert cooler suitable for operation on AC supply single phase 230/250 volts 50 Hz. complete all as directed by Engr-in-Charge.

80

-

-

... More
Taking out existing old wood wool pads from desert coolers and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F PVC insulated protective guards for holding the wood pads complete all as specified and as directed.

90

-

-

... More
Supply & Fix outer body of desert cooler 4000/5000/6000 cum/hrs capacity made out of galvanized iron sheets with bottom tank of 22 gauge, top cover of 24 gauge and side panels of 22 gauge GI sheet duly fitted with 2” thick wood wool pads including on heavy duty 22 guage front grill fitted with one piano type 5 Amps switch three speed selector switch of approved make with arrangement of changing the direction of air flow in replacement of unserviceable body complete all as directed.

20

-

-

... More
Replacement of PVC water distribution system 4 way suitable for 3000/4000/5000/6000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end ) heavy duty 15mm dia all as directed.

50

-

-

... More
Supply & Fix three speed selector switch complete with knob of approved make for desert cooler in replacement of unserviceable three speed selector switch complete. Make: USHA/KHAITAN/BAJAJ.

60

-

-

... More
Replacement of unserviceable side panels with wood wool 2" thick for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler complete. (Each Set Of Three Panels) complete all as directed by Engr-in-Charge.

15

-

-

... More
Replacement of damaged/rusted front grill made out GI sheet of 20 gauge heavy duty complete with knob to separate the shutter and S&F one piano type switch 6 Amp and one three speed selector switch complete all as specified and as directed by Engr-in-Charge.

15

-

-

... More
Painting of desert coolers in side out side at site of work with two coats of synthetic enamel paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.

15

-

-

... More
Supply & Fix Push cock of brass outer thread type 15mm chromium plated in replacement of unserviceable Push cock all as specified and directed by Engr-in Charge.

20

-

-

... More
Supply & Fix Push cock of brass inner thread type 15mm chromium plated in replacement of unserviceable Push cock all as specified and directed by Engr-in Charge.

20

-

-

... More
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size capacity 2/3 KVA complete all as specified.

10

-

-

... More
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 4 KVA complete all as specified.

2

-

-

... More
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 5 KVA complete all as specified.

2

-

-

... More
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 6 KVA complete all as specified.

1

-

-

... More
M & L for Replacement limit switch suitable for SP voltage stabilizer capacity 1/3/5 KVA complete all as specified

4

-

-

... More
Supply & Fix PVC float valve assembly in replacement of unserviceable PVC float valve assembly for water coolers of any capacity complete all as specified and directed. .

15

-

-

... More
Supply & Fix freezer cabinet suitable for cap upto 280 liters cap refrigerator in replacement of unserviceable freezer cabinet complete all as spd & directed.

2

-

-

... More
Supply & Fix freezer cabinet suitable for 300/ 320 liters cap refrigerator in replacement of unserviceable freezer cabinet complete all as spd & directed.

2

-

-

... More
Single pole and neutral enclosure with a two pin and earth plug and socket 20 A ,240 V complete with one single pole MCB complete all as spd & directed.

5

-

-

... More
Supply and fix 16 A 3 Pin plug top 240 V complete all as specified and directed

30

-

-

... More
Supply and fix 6 A 3 Pin plug top 240 V complete all as specified and directed

30

-

-

... More
Supply & Fix Bulb in replacement of unserviceable Bulb suitable for refrigerator of any size complete all as specified and directed

5

-

-

... More
Supply & Fix Waste water tray in replacement of unserviceable Waste water tray suitable for refrigerator of any size complete all as specified and directed

4

-

-

... More
Supply and fix PVC insulated Multicore standard Copper Cable 1.5 sqmm , 3 Core Complete all as specified and directed.

60

-

-

... More
Supply and fix PVC insulated Multicore standard Copper Cable 2.5 sqmm , 3 Core Complete all as specified and directed.

50

-

-

... More
Supply and fixing GI tubings medium grade 15 mm bore dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wall/floor for the following sizes including taking down of existing old GI pipes complete all as specified and directed by Engr-in-charge :-

18

-

-

... More
All item same as Ser item no 205 but 20 mm bore dia complete all as spd & directed.

12

-

-

... More
Supply and Fixing 15 mm Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe of the following bore sizes complete all as per spd and directed by Engineer-in-charge.

5

-

-

... More
All as per Ser item no 204 above but 20mm bore complete all as spd & directed.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.