Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Oct 2024
Closing Date3 Dec 2024
Tender Amount₹ 41,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) 70 Sqmm, 4 core

100

-

-

... More
(d) 50 sq mm, 4 core

100

-

-

... More
(e) 35 sq mm, 4 core

100

-

-

... More
(f) 25 sq mm, 4 core

100

-

-

... More
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT cable as in any type of soil and getting out complete all as specified and directed.

222

-

-

... More
Excavation in trenches n exceeding 1.5 Mtr wide and not exceeding 3 mtr depth and getting out in any type of soil complete all as specified and directed.

13.16

-

-

... More
Returning filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed.

106.37

-

-

... More
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.

119.7

-

-

... More
Sand cushioning to underground cables 8 cm below the cable before laying and 15cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.

66.8

-

-

... More
Supply and laying of fly ash bricks of best quality laid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and directed.

7

-

-

... More
M&L for mild steel cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms, complete all as specified and directed.

1

-

-

... More
M&L in replacement of ACSR conductor of any size and any type (as required on site) including stretching, fixing and binding to insulator on OH LT/HT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified and directed.

3

-

-

... More
M & L for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 (LT) volts grade. Including taking down old unserviceable pin insulator complete all as specified and directed.

40

-

-

... More
M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and complete all as specified and directed.

10

-

-

... More
Supply ,erecting and fixing the true vertical position, steel tubular swaged pole(410 SP-31),09 mtr long, complete with cast iron base plate, pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole ,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.(Numbering of the poles shall be done with synthetic enamelled painted letter of shape & size as directed. Note:-(a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately.

8

-

-

... More
S&F of on load change over switch 415 volt in sheet metal enclosure 3/4 pole of capacity from 63 Amp to 250 Amp complete all as specified and directed.

2

-

-

... More
M&L for Stright through joint of size 25 up to 240 Sqmm Sqmm 3½ ,4 core regin cast complete heat shrink outdoor type LT PVC / XLPE cable upto 1.1 KV complete with all accessories and generally conforming to IS 8438/1977 complete all as specified and directed.

10

-

-

... More
Supply and fixing copper thimble of size 50 to 120 Sqmm, all as specified and directed.

30

-

-

... More
Supply and fixing Aluminium thimble of size 25 to 70 Sqmm, all as specified and directed.

30

-

-

... More
Supply and fixing Aluminium thimble of size 95 to 150 Sqmm, all as specified and directed.

30

-

-

... More
Supply and fixing Aluminium thimble of size 185 to 240 Sqmm, all as specified and directed.

30

-

-

... More
Material and labour for Cement concrete 1:4:8 (using 40mm graded stone aggregate) as in sub base of poles / Strut including necessary frame work complete all as specified and directed.

0.43

-

-

... More
Material and labour for Cement concrete 1:3:6 (using 40mm graded stone aggregate in foundation filling and mass concrete including necessary frame work complete all as specified and directed.

14.13

-

-

... More
Material and labour for Cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in pole coping complete all as specified and directed.

0.83

-

-

... More
M&L for re stretching of LT ACSR conductor and GI wire of any size and on any type of poles carrying up to six conductors in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including refixing /re-adjusting line spans , line separators , cross arm on poles complete all as specified and directed.

40

-

-

... More
Cutting/Trimming/Chopping of tree trenches along the overhead line up to 3m from electric line clearance on both side of LT lines and disposing off the cut tree / Branches site to a distance not exc. 50m and clearing the site complete all as specified and directed.

40

-

-

... More
M&L for painting to LT poles, 9 mtr with cross arms, bracing and clamps with one coat of synthetic enamel paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of red and black from foot of pole up to 5 feet each strip of 30 cm height complete all as specified and directed.

40

-

-

... More
S&F MCCB 400 Amp 4 Pole 415 Volt breaking capacity 36kA.

1

-

-

... More
S&F MCCB 250 Amp 4 Pole 415 Volt breaking capacity 36kA.

1

-

-

... More
S&F MCCB 200 Amp 4 Pole 415 Volt breaking capacity 25kA.

1

-

-

... More
S&F MCCB 125 Amp 4 Pole 415 Volt breaking capacity 16kA.

1

-

-

... More
S&F MCCB 63-100 Amp 3/4 Pole (As per site Requirement) 415 Volt breaking capacity 16kA. complete all as specified and directed.

1

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode of size 60×60cm×6mm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 metres deep below ground level with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to equipment by using GI strips of size 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No.5 of MES schedule and connected to earthing test point all as specified and directed including earth pit of size 30cm x 30cm x 45 cm made of PCC 1:3:6 and PCC 1:2:4 cover, funnel, GI Tubing etc & testing on completion all as specified. Note :- The unit rate includes the cost of excavation & earth work in any type of soil, charcoal and salt in alternate layers, 20mm bore GI Pipe (med grade) for watering 40mm GI protection pipe (light grade) funnel, wire mesh, lugs, PCC 1:2:4 type B1 chamber in cement concrete 50mm thick precast RCC M-25 (design mix) cover duly reinforced with XPM (weight not less than 3kg/sqm) and CI frame etc and including provision of test point, connecting to test point and testing on completion etc complete all as specified. The unit rate also includes earthing lead and protection pipe upto 7.5mtr from top of earth plate.

8

-

-

... More
M&L for painting of stabilisers/ AVRs/ VCB panel set/ OCB Panel Set of any capacity after cleaning the body surface of transformer by rubbing with emery Paper and acetone to remove oil stains, dust etc and applying one coat of synthetic enamel paint (colour to be decided by MES) by spray painting including writing SM No/MES No, capacity of transformer, OCB panel complete all as specified and directed.

25

-

-

... More
Dehydration and filtration of transformer oil of transformer / Servo voltage stabilizer/ AVR installed at site with portable plant to improve the dielectric strength to 50 KV during filling after initial filtration including testing of dielectric strength after dehydration at site complete all as specified and directed. Note: Any damage to transformer/ stabiliser/ AVR caused during oil dehydration and filtration will be rectified by the contractor without any extra cost.

9000

-

-

... More
M&L for transformer oil having minimum dielectric strength of 60 KV, supplied in hermetically sealed steel barrels, confirming to IS-335, all as directed at site by engineer-in Charge (Part of this Transformer oil may be required to be filled in Transformers, which is included in this schedule)

1200

-

-

... More
M&L for dismantling the voltage stabilizers/ AVRs (any type) by taking out transformer oil and storing for reuse (after cleaning, filtering and removing moisture from it) and repairing / replacing the unserviceable parts, reassembling it after repair testing and commissioning the voltage stabilizer of capacity 10 to 400 KVA unbalanced type Installed at different location of AOR (spares to be measured and paid separately under relevant item of this schedule). Note : The Stabilisers/ AVR have to be taken for repair and a replacement Stabiliser/ AVR of same/ higher capacity to be placed within 168 hrs (seven days) from intimation in phone/ through WhatsApp, irrespective of any weather issues. For this purpose, the contractor has to submit a functional phone and WhatsApp number that is not to be switched off at any time. Any delay beyond this time will be fined at the rate of Rs. 1000 per day per stabiliser/ AVR

16

-

-

... More
M&L for replacement of burnt/ unserviceable defective HT/ LT copper coil of , AVRs and Servo Voltage Stabilisers, transformer with new one made out of suitable size/ gauge of copper super enamel wire strip of high quality matching with the existing impendence and insulated all as specified and directed. Note :- (a) The cost of coil shall be inclusive of cost of varnish, insulating paper and other insulating materials and no extra payment will be made for the same.

650

-

-

... More
(b) The cost is inclusive of disconnecting of all electrical connections and transportation of transformer from site to reputed repair workshop and back including reinstalling & reconnecting electrical connection and no extra payment will be made for the same.

-

-

-

... More
(c) Standby transformer/ stabiliser/ AVR will be arranged by contractor at his own cost to avoid failure of supply on site and the capacity of transformer should be matched with repaired transformer. This standby transformer will be brought within 48 hours of intimation (either by phone or by WhatsApp) of unserviceability of the original transformer (for this purpose, the contractor has to provide a WhatsApp number that is always functional).

-

-

-

... More
Taking out old unserviceable gasket of voltage stabilizer supply and fix rubber gasket of suitable size complete all as specified and directed.

16

-

-

... More
Supply and fixing in repair servo motor of 3 Kg torque capacity/rating complete for voltage correction having speed of correction 8 volt per second complete all as specified and directed.

8

-

-

... More
Supply and fixing in repair servo motor of 10 Kg torque capacity/rating complete for voltage correction having speed of correction 8 volt per second complete all as specified and directed.

8

-

-

... More
Supply and fixing in repair of Dimmer stat for unbalanced servo stabilizer complete all as specified and directed.

5

-

-

... More
Supply and fixing in repair of RC network for 10 Kg servo motor part/circuit for (any type of) voltage stabilizers If suitable RC network is not available in the market, then necessary modifications to the voltage stabiliser is also included complete all as specified and directed.

5

-

-

... More
Supply and fixing in repair of RC network for 3 Kg servo motor part/circuit for (any type of) voltage stabilizers If suitable RC network is not available in the market, then necessary modifications to the voltage stabiliser is also included complete all as specified and directed.

10

-

-

... More
Supply and fixing in repair for PCB Holder for unbalanced type voltage stabilizer all as specified and directed by engineer-in-charge. Note: If compatible PCB holder is not obtained by the contractor, then all suitable modifications (to the stabiliser to fit a PCB holder available with the contractor) with labour and material are also included complete all as specified and directed.

12

-

-

... More
Supply and fixing in repair push button for voltage stabilizer complete all as specified and directed.

30

-

-

... More
Supply and fixing in repair auto manual switch for voltage stabilizer complete all as specified and directed.

30

-

-

... More
Supply and fixing in repair rotary switch for RYB phases of voltage stabilizer complete all as specified and directed.

24

-

-

... More
Supply and fixing in repair for carbon bush of voltage stabilizer at site of any capacity complete all as specified and directed.

16

-

-

... More
Supply and fixing PCB /control card of (any type of) voltage stabilizer of capacity 50 KVA to 400 KVA for unbalanced type voltage stabilizer If suitable control card/ PCB is not available in the market, then necessary modifications to the voltage stabiliser is also included complete all as specified and directed.

16

-

-

... More
Supply and fixing in repair of bushing assembly including brass nut, stud, washer and insulator suitable for voltage stabilizers/ AVR complete all as specified and directed.

60

-

-

... More
Supply and fixing digital three phase Voltmeter - 0-500 Volt range square shape 96 mm complete all as specified and directed.

15

-

-

... More
Supply and fixing digital three phase Ammeter - 0-500 Ampere range square shape 96mm, with necessary CTs complete all as specified and directed.

15

-

-

... More
Material and Labour for replacement of Control Wiring complete with suitable copper wire of required size or as per sample/directed including accessories for voltage stabilizer (of any type) of capacity 200-400 KVA. If suitable control wiring is not available in the market, then necessary modifications to the voltage stabiliser is also included complete all as specified and directed.

6

-

-

... More
Material and Labour for replacement of Control Wiring complete with suitable copper wire of required size or as per sample/directed including accessories for voltage stabilizer (of any type) of capacity 50-200 KVA. If suitable control wiring is not available in the market, then necessary modifications to the voltage stabiliser is also included complete all as specified and directed.

8

-

-

... More
Supply and fixing Panel Lamp for balanced/unbalanced type voltage stabilizer complete all as specified and directed.

20

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

24

-

-

... More
Shifting of good conditioning voltage stabilizer from store yard / any sub division to cantt area/Unit area with proper safety to using hydro/JCB/crane etc and disconnecting old voltage stabilizer cable and earth connections and shifting back (to and from) to store yard /sub division including cable and earth connections with voltage stabilizer, fixing, testing, commissioning and checking the supply etc complete all as specified and directed.

5

-

-

... More
S&F Aluminium lungs thimble/bottle type of following size including taking down old one complete all as specified & directed.

-

-

-

... More
S & F in replacement of Modular metal flush box 4 module, complete all as specified and directed.

60

-

-

... More
S & F in replacement of Modular metal flush box 6 module, complete all as specified and directed.

60

-

-

... More
Taking out old unserviceable underground cable PVC insulated, PVC sheathed armoured heavy duty aluminium conductor LT 1100 v grade UG Cable of any size, wall and trenches etc after disconnecting of size complete all as specified and directed.

790

-

-

... More
Supply and lay in trenches, fixed to wall/pole UG Cable XLPE insulated screened PVC beaded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor, 1100V grade of size 16 sqmm 4 core complete all as specified and directed.

340

-

-

... More
Supply and lay in trenches, fixed to wall/pole UG Cable XLPE insulated screened PVC beaded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor, 1100V grade of size 10 sqmm 4 core complete all as specified and directed.

350

-

-

... More
Supply and lay in trenches, fixed to wall/pole UG Cable XLPE insulated screened PVC beaded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor, 1100V grade of size 25 sqmm 3.5 core complete all as specified and directed.

100

-

-

... More
Supply and fixing in replacement of 40mm dia steel tubes galvanised with fittings, laid in trenches/wall/pole for protection of underground cable when crossing the road complete all as specified and directed.

42

-

-

... More
Supply & Fix in repair 35/45 Watts LED integral floodlight luminaries, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source with IP 66 protection and including driver unit etc and taking down old unserviceable any size/watt of flood light complete all as specified and directed.

58

-

-

... More
Supply only LED street light fitting 70Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

22

-

-

... More
Supply & fix in repair street light fitting LED type 90 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unserviceable any size/watt of security light complete all as specified and directed.

20

-

-

... More
Supply & Fix in Repair 70 Watts LED integral floodlight luminaries, Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source with IP 66 protection and including driver unit etc and taking down old unserviceable any size/watt of floodlight complete all as specified and directed.

10

-

-

... More
S & F in repair bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm complete all as specified and directed.

25

-

-

... More
Supply and fix in replacement of FRP looping box of size 155x210x95 mm (HWD) with fuse/6 amps MCB provision and suitable connector for single phase connections loop in and out 10 to 16 sqmm 2 core aluminium armoured cable branch out 1.5 sqmm single core copper PVC insulated cable enclosed in thermoplastic /polycarbonate enclosure which should be shock proof safe IP 66/67 thermoplastic metric size glands ,GI clamps made out of GI flat of size 25mmX 3mm channel including making connections, taking down of old FRP box complete all as specified and directed.

20

-

-

... More
S&F driver unit suitable for LED street light 90 Watt /70Watt/45/35 complete all as specified and directed.

14

-

-

... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0/11 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one coat of alternate Yellow & Black Strips Painting (4 No. Each Strip 300 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and directed.

131

-

-

... More
S&F multi stranded Copper Conductor cable of size 3 Core 1.5 Sqmm complete all as specified and directed.

220

-

-

... More
M&L for Earthing complete with galvanized steel pipe electrode 40mm bore medium grade, 2.5m length, buried directly and preferably vertically in ground with top edge not less than 1.25 meter below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in electrical plate no 2 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated including testing complete all as specified and directed.

4

-

-

... More
M&L for M&L for dismantling and taking down the existing defective street light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 core 1.5 sqmm size multi stranded copper conductor including taking down old unserviceable 3 core 1.5 sqmm size copper conductor complete all as specified and directed. Note- 3 core 1.5 sqmm size multistranded copper conductor and driver will be measured and paid separately in respective item of schedule A.

100

-

-

... More
M&L for cement concrete in foundation of bed of poles streets and stays (1:4:8) type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed.

0.2

-

-

... More
M&L for cement concrete (1:2:4) type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly complete all as specified and directed.

1

-

-

... More
M&L for cement concrete in foundation of poles streets and stays 1:3:6 type D-2 using 40 mm graded crushed stone aggregate complete all as specified and directed.

4

-

-

... More
S & F in replacement steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-31 (9.0 metres long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally & portion embedded in concrete, making five black & yellow bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height all as specified and directed.

6

-

-

... More
M&L in replacement of Stay assembly for electric pole complete with accessories as shown in electrical plate No 1 of SSR Pt-I and drawing using loop type insulator, stay clamps, stay rod of 16 mm dia including stay wire of size 7/3.15 mm complete all as specified and directed. Note:- Excavation, earth work and concrete shall be measured and paid separately.

3

-

-

... More
Supply only in replacement of off load change over switch 415 volt in sheet metal enclosure 3/4 pole of capacity from 200 Amp complete all as specified and directed.

2

-

-

... More
Supply and fix cable jointing kit straight for 1100 volts (Earthed) grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE /(ABC), armoured, Aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed.

5

-

-

... More
M&L for hot Press Moulded SMC boxes with 200 Amps rating bus bar (04 Nos) and distribution board including MCB's, MS clamps fabricated from 25x3mm MS Flat iron, nuts, bolts etc for mounting complete all as specified and directed.

15

-

-

... More
Supply and fixing LED Flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection cable as required complete all as specified and directed.

7

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection cable as required complete all as specified and directed.

15

-

-

... More
Supply and fixing in maintenance LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. Excavation & earth work shall be measured and paid separately.

4

-

-

... More
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 6 Sqmm complete all as specified and directed.

250

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.