Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Mar 2025
Closing Date21 Mar 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699807_1Tender No
CWE/JA-42/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only Closing and tripping coil for SF6/VCB as per site requirements.
4
-
-
... More
Supply only Auxillary switch for 33/11 VCB as per site requirements.
2
-
-
... More
Supply only Limit switch for 33 KV VCB as per site requirements
2
-
-
... More
Supply only Hooter suitable for 33/11 KV breaker
2
-
-
... More
Supply only T&C switch with locking arrangement.suitable for 33 KV breaker
1
-
-
... More
Supply only Remote selector switch suitable for 33 KV breaker
1
-
-
... More
Supply only LED Indicating lamps of desired colour dual input type.
10
-
-
... More
Supply only Vaccum Interrupting unit (bottle type) suitable for SF 6 breaker.
1
-
-
... More
Supply only Control Cable 8 core armoured control 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit.
120
-
-
... More
Supply only Control cable 4 core armoured control cable 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit.
150
-
-
... More
Supply and fixing new CT outdoor type oil immersed ratio 75-50/5+5A (three core type) Class I & 5P10 VA Burden-15 with first oil filled suitable for 33 KV power supply by providing suitable size of nuts, bolts on existing structure complete including taking out old unserviceable CTs. complete all as specified and as directed by Engr- in- Charge. Make-Jyoti(JSL)/Gyro/Laxmi/Areva, schneider.
1
-
-
... More
Supply, fixing, commissioning and testing of 33000 x 110 volts / √3 outdoor type single pole potential transformer and self air cooled type having 200 VA burden suitable for metering of equipment installed on existing structure with suitable fixing arrangement including dismantling of old PTs complete all as specified and as directed by Engr- in- Charge. Make : Huphen, Areva, schneider
1
-
-
... More
Supply and fixing in replacement of 33 KV rotating , horizontal type, isolator switch 400 Amp complete with all fixing arrangements after disconnecting all electric connections, and keeping aside for offering credits, complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
M&L for scrapping laid out aggregate of any size and removing from site and cleaning of dirt and vegetation from site and relaying of the same in switchyards complete all as specified and as directed by Engr- in- Charge.
600
-
-
... More
Preparation of iron fencing complete 33 KV grid including gates of iron gates by scrapping of rusted materials, and painting with two coats of aluminium paint of approved make and colour complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
Preparation of old cement based painted surfaces by scrapping of deposited materials, and painting with two coats of cement based paint of approved make and colour complete all as specified and as directed by Engr- in- Charge.
60
-
-
... More
M&L for painting of HT 33 KV HT grid steel structure including all MS channel isolators, CTs, PTs and MOCBs, VCBs, bus bar and other steel structure with synthetic enamelled aluminium paint on structure and other colour code for equipment after proper surface preparationcomplete all as specified and as directed by Engr- in- Charge.
2
-
-
... More
M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse) including dismantling old conductor and clamp complete all as specified and as directed by Engr- in- Charge.
30
-
-
... More
M&L for repalcement of PG clamps, parallel grove clamps, tee clamps, GI nuts bolts of required size other connectors for connecting ACSR conductor for jumpering complete all as specified and as directed by Engr- in- Charge.
20
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 25x4 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected to existing structure by means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and as directed by Engr- in- Charge.
15
-
-
... More
Supply and fixing Danger notice plate of 1.6 mm thick MS sheet,25X20CM Size vitreous enamelled white with letters, figures and conventional skull and bones with MS clamp, bolts and nuts of approved size for HT 33 KV/ 11 KV mark including taking down old u/s Danger notice plates etc, complete all as specified and as directed by Engr- in- Charge.
30
-
-
... More
M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9, Incl taking down old pole and remove from site complete all as specified and as directed by Engr- in- Charge.
5
-
-
... More
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles etc, complete all as specified and as directed by Engr- in- Charge.
4.8
-
-
... More
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engr- in- Charge.
0.13
-
-
... More
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 Sq mm, 3 core complete all as specified and as directed by Engr- in- Charge.
245
-
-
... More
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 Sq mm, 3 core complete all as specified and as directed by Engr- in- Charge.
145
-
-
... More
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 240 Sq mm, 3 core complete all as specified and as directed by Engr- in- Charge.
70
-
-
... More
M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 1.5 Mtr wide and not exc. 1.5 m in depth for foundation and getting out complete all as specified and as directed by Engr- in- Charge.
137.8
-
-
... More
M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 3.0 Mtr wide and not exc. 3.0 m in depth for foundation and getting out complete all as specified and as directed by Engr- in- Charge.
1.2
-
-
... More
M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavation complete all as specified and as directed by Engr- in- Charge.
99.5
-
-
... More
M & L for unwashed sand cushioning below and around cable in trenches with river sand complete all as specified and as directed by Engr- in- Charge.
39.5
-
-
... More
M & L for unwashed sand cushioning below and around cable in trenches with river sand complete all as specified and as directed by Engr- in- Charge.
35
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified and as directed by Engr- in- Charge.
1880
-
-
... More
S & F in replacement of 80mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and as directed by Engr- in- Charge.
9
-
-
... More
S & F in replacement of 100 mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and as directed by Engr- in- Charge.
9
-
-
... More
Supply and fix in replacement of cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 240 sqmm to 300 sqmm complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
Supply and fix in replacement of cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
Supply and fix in replacement of cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
Description all as per item No 30 above but 120 sqmm to 185 sqmm
2
-
-
... More
Supply and fix in replacement of cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and as directed by Engr- in- Charge.
2
-
-
... More
Description all as per item No 32 above but 120 sqmm to 185 sqmm
4
-
-
... More
Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and as directed by Engr- in- Charge.
6
-
-
... More
Supply insatallation, testing and commissioing of maintenance free earthing based on 300mm long GI earthing Electrode (Met -Chem) 80mm outer dia and inner rod with 10mm thickness 3000mm long duly filled with ITPC-EECP15 fixed with nuts an bolts incl excavation/ earth work in any strata & PCC chamber with CI Frame and cover (Earth pit not less than 2.25 mtrs below ground level). The electrode is surrounded by chemical (ITPC-EECP15) a mixture of sulphate, silica, Iron Oxide etc, magnesium oxide, sodium oxide, zinc oxide etc. Each Earth electrode should have resistance 2 Ohm by using earth electrode is used as per the site requirements. Chemicals compound powder to be provided minimum 50Kg per site. The inspection joint provide for earthing reference incl the man hole cover with locking facility be provided. complete all as specified and as directed by Engr- in- Charge. (Make: ITPC/KEGS/TERRAFILL)
4
-
-
... More
S&F in replacement of copper strip of size 20x3 mm as in earth continiuty conductor fixed to wall on batten or recess or cases or buried in ground or any other situation for loop earthing as required at site complete all as specified and as directed by Engr- in- Charge.
45
-
-
... More
Disconnecting electrical connections from HT 33/11 KV transformer of any descriptions by opening of earth & control connections of any type, sealing of oil leakage, replacement of unserviceable parts and filtration of oil, cleaning the transformer, including making all HT connections, control cable connection, earth connection etc including testing the transformer after necessary repairs, complete all as specified and as directed by Engr- in- Charge. Note:- Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items
2
-
-
... More
Supply and fixing in replacement of primary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engr- in- Charge.
Note:- Primary coil shall have same number of turns of winding wire and with matching to manufacturer design.
385
-
-
... More
Supply and fixing in replacement of secondary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engr- in- Charge.
Note:- Secondary coil shall have same number of turns of winding wire and with matching to manufacturer design.
325
-
-
... More
Disconnecting electrical connections from HT and LT sides of old unserviceable/ damaged/ burnt step down transformers of any descriptions, capacity upto 400 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed by Engr- in- Charge. Note:- Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ.
10
-
-
... More
Replacement of old unserviceable/ damaged 33 KV HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, any capacity complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
Replacement of old unserviceable/ damaged 11 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity, complete all as specified and as directed by Engr- in- Charge.
15
-
-
... More
Replacement of old unserviceable/ damaged cork sheet gasket with new cork sheet gasket, suitable for transformer of any capacity, complete all as specified and as directed by Engr- in- Charge.
10
-
-
... More
M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse) including dismantling old conductor and clamp complete all as specified and as directed by Engr- in- Charge.
4330
-
-
... More
Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 33/11 KV transformer including nuts, bolts and washers complete all as specified and as directed by Engr- in- Charge.
2
-
-
... More
Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel capacity 500 gm suitable for 11/.440 KV transformer including nuts, bolts and washers complete all as specified and as directed by Engr- in- Charge.
15
-
-
... More
Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification, examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment,complete all as specified and as directed by Engr- in- Charge. Make: IOCL/ HPCL/ BPCL/ Reliance.
1250
-
-
... More
Preparation of old, external surface of 11/0.44 KV transformers any capacity, by removing the scrap, rust, washing including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, at site or at workshop, complete all as specified and as directed by Engr- in- Charge.
2
-
-
... More
M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 12 kilo amp, 11000 volts including taking down old unserviceable lightening arrestor complete all as specified and as directed by Engr- in- Charge.
20
-
-
... More
M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 33000 volts including taking down old unserviceable lightening arrestor complete all as specified and as directed by Engr- in- Charge.
1
-
-
... More
M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 12 kilo amp, 11000 volts including taking down old unserviceable lightening arrestor complete all as specified and as directed by Engr- in- Charge.
6
-
-
... More
M&L for Gang operated Isolating Switch 11 kV Triple pole vertical type, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps, 15 insulators, incl drop out fuse assy including taking down old unserviceable GOD complete all as specified and as directed by Engr- in- Charge.
10
-
-
... More
Supply and fixing Electrical accident / shock treatment chart mounted on wodden framecomplete all as specified and as directed by Engr- in- Charge.
10
-
-
... More
M&L for guarding cradles, made to shape hexagonal/rectangular or any other shape fabricated with GI 4 mm dia wire including binding wire and taking down old unserviceable guarding cradles etc complete all as specified and as directed by Engr- in- Charge.
0.5
-
-
... More
S&F in replacement of Disc type insulator porcelain, vitrous 145 mm high and 255 mm dia ball and socket type, (white, brown or green) complete single disc assembly for ACSR conductor having working pressure 11000 volts grade complete all as specified and as directed by Engr- in- Charge
24
-
-
... More
S&F in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed by Engr- in- Charge.
15
-
-
... More
S&F in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade complete all as specified and as directed by Engr- in- Charge.
8
-
-
... More
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint Including old U/S taking down. complete all as specified and as directed by Engr- in- Charge.
1.5
-
-
... More
M&L for Hardcore Aggregate of guage n. exc 40mm deposited, spread and levelled in layers n exc. 15 cm thick, to a true surface complete all as specified and as directed by Engr- in- Charge.
15
-
-
... More
Taking out old unserviceable existing Relay and S&F digital protective relays 3 phase and earth fault (04 Nos output contact) with high set, CT ratingA, field selectable 20-110 volt supply, for existing HT OCB 11 KV, complete all as specified and as directed by Engr- in- Charge. Make : L&T Model MC-61A or equivaltent in ALSTOM/AE/Rishab/Meco/Enercon
2
-
-
... More
Servicing and complete overhauling of VCB 11 KV Indoor type 630 Amps capacity including disassembly of operating mechanism parts, well cleaning with petrol & CRC-226, replacing of moving parts, re-assembly, fine setting of mechanism, replacement of unserviceable parts and re-assembly of parts including well cleaning the complete panel board main bus bar, de-carbonizing all joints, bus bar, CTs’ PTs spouts, metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance complete all as specified and as directed by Engr- in- Charge.
4
-
-
... More
Routine preventive and annual maintenance of RTCC Panel, dismantling complete and cleaning, repair / replacement of burnt out electrical accessories, checking of connections , repair and replacement of complete internal wiring, current and earth fault relay, voltmeter, ammeter, tripping coil with system, burnt out elecrical parts etc. as existing specification, setting of relays with provided values complete all as specified and directed by Engr-in-charge. All minor/ Burnt spares/works, bolts, nuts, washers, connectors, pins, panel hinges, locks, allignment, lubricants etc shall also be included in quoted rates.
1
-
-
... More
Supply and fixing by stringing stretching and strengthening on insulators ACSR conductor of desired size including aluminium binding wire of suitable cross sectional area including joints sleeve for jointing conductors of equal or unequal size and for jumpers connections including treatment of connector and ACSR conductor joints/jumpers with conducting jelly, and taking down of UNSV conductors complete all as specified and as directed by Engr- in- Charge.
2
-
-
... More
S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER / 11 KV CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required / ordered at site) complete all as specified and as directed by Engr- in- Charge.
75
-
-
... More
Cutting unaxious green groth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed by Engr- in- Charge.
Note:- The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
1500
-
-
... More
Clearing and cleaning of vegtation and creeper around various 4/2 pole structure complete all as specified and as directed by Engr- in- Charge.
25
-
-
... More
M & L for replacement of old unserviceable/ damaged 11 KV LT bushing assembly with new LT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity, complete all as specified and as directed by Engr- in- Charge.
20
-
-
... More
Repairing/ servicing/ overhauling of gang operated device 11000 volts, 200/ 400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points tightening all jointing/ bolts nuts including replacing wornout the bolt and nuts commissioning and testing including dismantling and replacing the unserviceable parts/ spares complete all as specified and as directed by Engr- in- Charge.
Note:- All the spares replaced will be measured & paid separately (labour cost for replacement of spares not covered berein below is also deemed included in the above quoted rate. Supply only the following spares for replaceing in reapirs/ servicing.
20
-
-
... More
(a) Moving contact blades
10
-
-
... More
(b) Fixed contact jaw copper
10
-
-
... More
(c) PG clamps of suitable size as per site requirement.
30
-
-
... More
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete of HT Pole (above the planting depth and PCC copings) and MS cross arms, cable protection pipe, brackets etc and applying two coats of of exterior weather proof paint (Cement based paint) of approved colour to pole and to MS cross arms, cable protection pipe, brackets etc with two coats of Aluminium Paint over a coat of red oxide primer including Synthetic enamel Painting in alternate lines of Yellow & Black Strips min of 6 Nos (each Strip 200 mm wide) at bottom of pole complete all as specified and as directed by Engr- in- Charge.
145
-
-
... More
M & L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles of HT Pole (above the planting depth and PCC Copings) and MS cross arms, cable protection pipe, brackets etc and applying two coats of Aluminium Paint over a coat of red oxide Zinc Chrome Primer, including Synthetic enamel Painting in alternate lines of Yellow & Black Strips min of 6 Nos (each Strip 200 mm wide) at bottom of pole complete all as specified and as directed by Engr- in- Charge.
20
-
-
... More
M & L for Writing Lettering on Steel Tubular/Pre-stressed Concrete Pole (8 Cm in height) with Synthetic Enamel Paint (White) on base of Black Paint in round shape of 15 Cm dia, complete all as specified and as directed by Engr- in- Charge.
165
-
-
... More
M & L for loop type insulator, porcelain vetrieous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm complete all as specified and directed by Engr - in - Charge.
12
-
-
... More
M & L in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 16 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all assprcified and directed including necessary excavation and earth work and PCC 1:3:6 all as shown in electrical plat No.1 of SSR-1991 Part-I (PCC and earth work, loop type insulator, stay clamps shall be measured and paid for separately under the respective item of schedule) including taking down existing old unsv stay assembly complete all as specified and directed by Engr-in-Charge.
6
-
-
... More
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
15
-
-
... More
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of ₹ 2,83,582.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%