Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date21 Dec 2024
Closing Date17 Jan 2025
Tender Amount₹ 48,47,000
Costs
EMD
₹ 97,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689881_1Tender No
GER-74/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings, complete all as specified and directed.
364
-
-
... More
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work as in purlin and rafter, complete all as specified and directed.
1.05
-
-
... More
Demolition of cement concrete (unreinforced) (spalling concrete without disturbing reinforcement) of any description and in any position not otherwise specifically provided for, and removing debris outside MoD land, complete all as specified and directed. (Note:- Rate of scaffolding required at site in r/o height of bldg will be included in the quoted rate.)
25
-
-
... More
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. (Note:- Rate of scaffolding required at site in r/o height of bldg will be included in the quoted rate.)
850
-
-
... More
M&L for 100mm thick plain cement concrete 1:2:4, type B-2 using 40mm graded crushed stone aggregates as in flooring in alternate pannels, finished surface even and smooth without using extra cement using surface vibrator, complete all as specified and directed.
1350
-
-
... More
M&L for 75mm thick plain cement concrete, type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
100
-
-
... More
S&F of rolled mild steel as in stair (framed) including stringers, treads, landing, baluster, hand rails etc (Fe- 410-W, Gde-E-250, quality-A) including cleats, brackets etc, complete all as specified and directed.
450
-
-
... More
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
280
-
-
... More
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
84
-
-
... More
S&F in repair 1.25mm thick mild steel plain black sheet in wall cladding, eaves gutters, and similar work, cut to size, holes punched , including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up , mitered angles and making provision for funnel shape at site etc as required, complete all as specified and directed.
84
-
-
... More
M&L for plain cement concrete 1:2:4, type B-0 using 12.5mm graded crushed stone aggregates as in levelling course (o as to provided slope) , benching kerb of mud stops, rounded or chamfered on edge including form work, complete all as specified and directed.
10
-
-
... More
Supply only integral water proffing compound, complete all as specified and directed.
50
-
-
... More
Heavy Duty reinforced acrylic coating for terrace/walls water proofing over a coat of Primmer for Sealer coat with roller, complete all as specified and directed. Make:- Dr Fixit/ Sikka/ Texa Ind Ltd
160
-
-
... More
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:4 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound as per manufacturer's instructions.
(b) Apply a coat of bituminous primer confirming to IS-3384@ 0.3kg/Sqm on newly plastered surface after curing as per IS-456 and dried.
(c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. (iii) WPC shall be measured and paid separately.
1300
-
-
... More
M&L for applying one coat of "rust remover" or "Defroster" or equivalent chemical (as approved by Engr-in-Charge) to old rusted reinforcement after necessary preparation of surfaces by brush application, complete all as specified and directed. Make:- Dr Fixit/ Sikka/ Texa Ind Ltd
810
-
-
... More
S&F for hard drawn steel wire fabric cut to length bent to shape, fabric 2mm dia, 50mm mesh cover entire steel surface not exc 4kg per Sqm, complete all as specified and directed.
810
-
-
... More
M&L for bonding the entire exposed surface with one coat of bonding agent (as per manufacturer's instruction) to enhance the bond strength of concrete or mortar, complete all as specified and directed. Make:- Dr Fixit/ Sikka/ Texa Ind Ltd
810
-
-
... More
M&L for applying one layer of shortcrete concrete 20mm to 25mm thick (comprises composition PCC 1:2:1, one part of cement two parts of fine aggregate and one part of 10mm and down size trap stone aggregate) mixed with spray set SL 2 to 2.5% weight of cement and 12.5 to 16.5 litres of water mixed as per manufacturer's instruction and gunniting pressure nozzle with a delivery capacity of 2.5Kg per sqm over column, beam, roof slab and other similar works, complete all as specified and directed. Note:- Contractor shall provide the even surface without any exta cost to govt. duly floated and clearance from wall, floor or site damaged due to splashing of cement grouts. Make:- Dr Fixit/ Sikka/ Texa Ind Ltd
810
-
-
... More
M&L for mild steel deformed or twisted TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality comfarming to Fe-410-S, or FE-410-O, complete all as specified and directed.
50
-
-
... More
M&L for dubbing out average 20mm thick in cement mortar 1:4 on irregular face of old walls/ ceiling, fin facia chajjas etc, complete all as specified and directed.
100
-
-
... More
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed.
3
-
-
... More
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling surface, finished the surface even and smooth without using extra cement (at any height upto 7mtr), complete all as specified and directed.
400
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished the surface even and smooth without using extra cement, complete all as specified and directed.
350
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished the surface even and smooth without using extra cement, complete all as specified and directed.
150
-
-
... More
M&L for providing plain cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregates) as in coping etc, complete all as specified and directed.
0.3
-
-
... More
S&F in repair for 100mm bore cast iron rainwater socketed pipes with cement joints with ears including stack clamps made out of 50x5mm flat iron and 16mm dia round iron stays of suitable length including bolts and nuts and securing ends of stay to wall or roof, complete all as specified and directed.
40
-
-
... More
S&F in repair for 100mm bore cast iron bends or elbows, square or obtuse for rain water socketed pipes, complete all as specified and directed.
15
-
-
... More
M&L for preparation of newly plastered surfaces of wall and applying two coats of cements base paint over a coat of primer, complete all as specified and directed.
150
-
-
... More
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
350
-
-
... More
M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
1150
-
-
... More
M&L for preparation of old plastered surfaces of wall and applying one coat of white wash, complete all as specified and directed.
1450
-
-
... More
M&L for preparation of old plastered surfaces of wall and applying two coats of cements base paint over a coat of pimer, complete all as specified and directed.
750
-
-
... More
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
15
-
-
... More
M&L for preparation of old steel surface of any description over 10 cm width or girth not and applying one coats of synthetic enamel paint, complete all as specified and as directed by Engr-in-Chagre.
150
-
-
... More
M&L for anti-termite treatment to treatment of soil under existing floors using emulsion @one litre per hole, 300mm apart including
drilling and plugging 12mm dia holes with cement mortar 1:2 to atch the existing floors, complete all as specified and directed.
1590
-
-
... More
M&L for anti-termite treatment to treatment of soil along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
29
-
-
... More
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
522
-
-
... More
Sch 'A' Part-II (E/M works)
S&F in repair of single pointed air termination, copper rod 12mm dia 300mm long, including aluminium base plate of size 125mm x 125mm x 10mm fixed over hylum sheet of size 175mm x 175mm x 10mm fixed on roof top, complete all as specified and directed.
36
-
-
... More
S&F in repair for GI pipe light grade 25mm bore for installation of air termination rod, complete all as specified and directed.
72
-
-
... More
S&F in repair of test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw inlcuding connecting down conductor and earth strip, complete all as specified and directed.
12
-
-
... More
S&F in repair of copper strip of size 20x3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles, complete all as specified and directed.
619.2
-
-
... More
M&L for precast cement concrete 1:3:6, type C-1 using 20mm graded crushed stone aggregate for fixing of 25mm GI pipes and air termination rod, complete all as specified and directed.
2
-
-
... More
M&L for earthing complete with copper earth plate electrode 600x600x3.15mm thick burried directly in ground earth pit not less than 4m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 20x3mm thick copper strip for from earth electrode to test point/ equipment of upto 7.5 m whichever is less by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed.
(Note:-Earth strip and protection pipe upto test point/equipment upto 7.5m is included in the rate quoted)
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%