Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date7 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Summary

Ca No. Ge(af)/sgr-67/2024-25 Repair / Maintenance Of Eot Cranes, Low Voltage Switch Gear, Panels, Bus Bars Including Cabling Work At 1 Wing

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HOIST :- (a) Inspect wear/ tear of wire rope, Hook block and break lines etc. and testing of rope, (b) Checking of electrical circuit limit switch and wiring LOAD FOR LOAD TESTING :- (a) Contractor shall arrange necessary load as per the site requirement of the crane including shifting of load to the site by using crane, truck, labour, etc, (b) Contractor shall take care of the floor while shifting/ lifting the load and if any damage found at site shall be rectified with in 24 Hrs, (c) Load test shall not be more than 110% of the rated load. , (d) Contractor shall shift the load to inside the building for load testing of crane carefully by using crane/truck/fork lift/ labour without damage to the existing infrastructure, (e) Load testing shall be carry out as per ISO:4310 of 1981 and IS:14470 of 1997 with latest amendments on the IS . TEST REPORT:- (a) On completion of the load test, a test report shall be prepared listing the conclusions and finding of the test for each crane, The report shall identify the crane tested, shall give the date aned location of the tests, name of the Engineer tested, details of load, positions, configurations and findings if any in each case. (b) T&P for the load test and safety of the mechanic/ Engineer shall be at contractor's risk.

3

-

-

... More
Supply and fixing spares/components of the unserviceable crane of capacity 3 Ton complete all as specified and directed.

-

-

-

... More
3 pole Contactor 10 Amps, 415v,

3

-

-

... More
Over load relay

3

-

-

... More
Brake Pads.

3

-

-

... More
Gear box bearing

3

-

-

... More
Brake lining

3

-

-

... More
Limit switch for LT/CT

3

-

-

... More
S&F in repairs LT PVC insulated and PVC sheathed copper conductor cable 6.0 sqmm 4 core for pendent, complete all as specified and directed.

170

-

-

... More
S&F in repairs LT PVC insulated and PVC sheathed copper conductor control cable 2.5 sqmm 4 core, complete all as specified and directed.

135

-

-

... More
S&F in repairs LT PVC Copper cable of size 10.0 Sqmm single core, complete all as specified and directed.

250

-

-

... More
S&F in repairs LT PVC Copper cable of size 6.0 Sqmm single core, complete all as specified and directed.

230

-

-

... More
S&F Crane cable trolley , complete all as specified and directed.

3

-

-

... More
S&F in repairs MCB TPN 415 V, 32 Amps , C curve, complete all as specified and directed.

3

-

-

... More
S&F in repairs MCB TPN 415 V, 63 Amps , C curve, complete all as specified and directed.

3

-

-

... More
Disconnecting gear box assembly and taking out gear wheel and replacement of other worn out parts, oil seal and gear oil after over hauling including lath work as required at site, re-assembly and re-fixing the same and testing complete for 3 Ton capacity EOT crane, complete all as specified and directed. Note :- Gear oil and other major spares will be measured and paid in relevant items.

3

-

-

... More
Disconnecting and taking out the defective electric motor from the cranes, transporting to workshop for replacement of burnt out winding with existing gauge super enameled copper wire including insulating paper and varnishing and re-fixing motors to crane after testing, upto 7 HP motor, complete all as specified and directed.

3

-

-

... More
Disconnecting and taking out the defective electric motor from the cranes, transporting to workshop for replacement of burnt out winding with existing gauge super enameled copper wire including insulating paper and varnishing and re-fixing motors to crane after testing, upto 5 HP motor, complete all as specified and directed.

3

-

-

... More
Disconnecting and taking out the defective electric motor from the cranes, transporting to workshop for replacement of burnt out winding with existing gauge super enameled copper wire including insulating paper and varnishing and re-fixing motors to crane after testing, upto 1 HP motor, complete all as specified and directed.

3

-

-

... More
Repair/maintenance of sliding door mechanical/electrical driving mechanism with replacement of bottom wheel of 300mm dia made of EN-9 steel, top wheel 90mm with paint of epoxy greasing complete, out door type heavy duty electro mechanical drive unit 9 suitable for upto 8000 Kg with control panel duly with replacement of overload protection MCCB, Motor protection, Emergency switch, LED Push button switch for forward reverse stop function, festoon type arrangement, all cables conducting, and bunching wire, hardware hoter cum blinker for safety of door, manual de-clutching, arrangement in case of power failure EPM Gasket at edges of door to protect from rain and dust heavy duty buffer stopper at both ends, complete all as specified and directed.

3

-

-

... More
S&F in repairs of forward and backward motion indicator lights in Red/Green colour, complete all as specified and directed.

3

-

-

... More
M&L for welding work of angle iron of various sizes for driven portion of sliding doors with painting, complete all as specified and directed.

3

-

-

... More
Supply, laying, jointing and testing, LT cable 1100 volts grade of cross sectional area 120 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables including taking down old unserviceable XLPE LT cables, complete all as specified and as directed. (Note : MS clamps with nuts, bolts washer etc shall deemed to be included in quoted rate)

350

-

-

... More
All as per Ser Item No. 19.00 here in above but size of cable 70 Sqmm X 3.5 core

180

-

-

... More
All as per Ser Item No. 19.00 here in above but size of cable 50 Sqmm x 3.5 core

60

-

-

... More
All as per Ser Item No. 19.00 here in above but size of cable 35 Sqmm X 3.5 core

70

-

-

... More
All as per Ser Item No. 19.00 here in above but size of cable 16 Sqmm X 4 core

200

-

-

... More
All as per Ser Item No. 19.00 here in above but size of cable 16 Sqmm X 2 core

250

-

-

... More
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth and getting out for laying of underground cable etc in any type of soil, complete all as specified and directed.

240

-

-

... More
Returning filling including spreading, levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil, complete all as specified and directed.

185

-

-

... More
Removing of excavated soil to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.

55

-

-

... More
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed.

7721

-

-

... More
M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm, complete all as specified and directed. Note:- Only punned thickness shall be measured and paid.

72

-

-

... More
S&F in repairs MCCB, 4 pole, capacity 250 Amp, 25KA, complete all as specified and directed by Engr-in-Charge.

9

-

-

... More
S&F in repairs MCCB, 4 pole, capacity 200 Amp, 25KA, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
S&F in replacement of 50mm dia GI pipe, light grade, for housing/protection to the LT cables, complete all as specified and directed.

150

-

-

... More
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate), complete all as specified and directed.

80

-

-

... More
S&F in replacement of existing unsv street light fittings with LED street light fitting 50 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, having surge protection device 10 KV, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm, complete all as specified and directed.

25

-

-

... More
S&F in replacement of existing unsv flood light fittings with LED flood light fitting 100 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm, complete all as specified and directed.

20

-

-

... More
Supply, installation testing & commissioning, LT panel cubical type of size 0.9 x 0.6 x 0.6 Metre, CPRI Approved, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type, factory fabricated, duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 40 mm x 40 mm x 6 mm and 0.5 m long covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel, complete all as specified and directed.

2

-

-

... More
Incoming:- (a) MCCB 4 pole, 250 Amp, 35 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 No. (b) Copper bus bar 200 Amp TPN - 04 Nos (c) Digital voltmeter 0-500 volts with selector switch - 01 No (d) Digital Amp meter 0-200 Amp with selector switch & CT- 01 No (e) Indicator lamp LED type (R, Y, B) complete with Bakelite fuse fitting - 01 Set Outgoing:- (a) MCCB 4 pole, 63 Amp, 16 KA, 415 volts AC- 02 Nos (b) MCCB 100 Amp, 16 KA, 415 Volts AC- 01 Nos Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.

-

-

-

... More
Supply, installation testing & commissioning, LT panel cubical type of size 0.9 x 0.6 x 0.6 Metre, CPRI Approved, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type, factory fabricated, duly powder coated inside and out side, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 40 mm x 40 mm x 6 mm and 0.5 m long covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel, complete all as specified and directed.

1

-

-

... More
Incoming:- (a) MCCB 4 pole, 400 Amp, 35 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 No. (b) Copper bus bar 200 Amp TPN - 04 Nos (c) Digital voltmeter 0-500 volts with selector switch - 01 No (d) Digital Amp meter 0-200 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with Bakelite fuse fitting - 01 Set Outgoing:- (a) MCCB 4 pole, 63 Amp, 16 KA, 415 volts AC- 02 Nos (b) MCCB 4 pole 250 Amp, 16 KA, 415 volts AC- 01 No. Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.

-

-

-

... More
Supply, installation testing & commissioning, LT panel cubical type of size 0.9 x 0.6 x 0.6 Metre, CPRI Approved, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type, factory fabricated, duly powder coated inside and out side, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 40 mm x 40 mm x 6 mm and 0.5 m long covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel, complete all as specified and directed.

1

-

-

... More
Incoming:- (a) MCCB 4 pole, 400 Amp, 35 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 02 Nos. (b) Copper bus bar 200 Amp TPN - 04 No's (c) Digital voltmeter 0-500 volts with selector switch - 01 No (d) Digital Amp meter 0-200 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with Bakelite fuse fitting - 01 Set Outgoing:- (a) MCCB 4 pole, 160 Amp, 36 KA, 415 volts AC- 02 Nos (b) MCCB 4 pole, 63 Amp, 16 KA, 415 volts AC- 01 Nos Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.

-

-

-

... More
Supply, installation testing & commissioning bus bar chamber, factory made, weather and vermin proof having size 200 x 250 x 80 mm made out of 3.15 mm thick CRCA sheet, comprising of MCB SP 10A, C curve 10 KA breaking capacity 01 No's, 16 Amp 230 volt rated aluminium bus bar with mounting rail fixed on porcelein insulator, making holes on strips for connecting cables and fixing of bus bar chamber on street light pole with and including MS clamp of size 25 x 5mm including nut, bolts washers duly painted with 2 coats of enamel paint over a coat of red oxide primer including taking down old bus bar chamber, complete all as specified and directed.

3

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking out of existing earthing, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item.

6

-

-

... More
M&L for painting of steel tubular poles of hight 7 to 7.50m above GL with cross arms and bracings with two coats of aluminium paint painting, including 30 cm wide black & white alternate strips up to 1.5m above from ground level with synthetic enamel paint including numbering of the pole, complete all as specified and directed.

50

-

-

... More
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismentling/taking down items) worth Rs 72,891.00 during AOC. Note :- Tenderers shall not quote for this Schedule.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.