Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 21,57,871 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 61,640Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672721_1Bid Award Id
ViewTender No
GE/AFU-41/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for N2 Flushing, leakage testing & Vaccummissing for AC plant complete all as specified and as directed.
3
-
-
M&L for Motorized FP Dampers for Duct at distribution ends AC complete all as specified and as directed.
2
-
-
M&L for Motorized FP Dampers for ducts at Packaged AC complete all as specified and as directed.
2
-
-
S&F in repair Compressor of capacity 5.5 ton complete all as specified and as directed by Engr-in-Charge. Make: Voltas or its equivalent
1
-
-
S&F in repair PCB circuit forpackage type AC complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair 3HP ,415 Volt,50HZ Blower motor for package type AC complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Single Phase preventer complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair AL powder coated Grill complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair AL powder coated Diffusers complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair HP Switch Packaged type AC complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair LP Switch Packaged type AC complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Sensor for Packeged type AC complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Expension valve 5.5 TR complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Insulation Nitrile Rubber 13mm complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Canvass Connection fire proof complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Copper piping, Insulation, supporters, Nut bolts, painting of pipe ( If requierd ) Angle bracket etc complete all as specified and as directed by Engr-in- charge.
10
-
-
S&F in repair MCCB 4 Pole, 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos complete all as specified and as per existing size directed by Engr-in- charge.
2
-
-
S&F in repair MCCB 4 Pole, 100 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos complete all as specified and as per existing size directed by Engr-in- charge.
1
-
-
S&F in repair MCCB 4 Pole, 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection, -01 Nos complete all as specified and as per existing suitablesize directed by Engr-in- charge.
1
-
-
S&F in repair Power contactor 32 Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge.
10
-
-
S&F in repair Power contactor 100 Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge.
10
-
-
S&F in repair Air pressure meter /guage as per existing model complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair Temperature meter /guage as per existing model complete all as specified and as directed by Engr-in- charge.
2
-
-
S&F in repair strip heater 3 KW complete all as specified and as directed by Engr-in- charge.
25
-
-
Disconnecting the motor with centrifugal pump set and Repair/Rewinding of motor of capacity 3/5 HP three phase 415 Volts ,50 HZ by rewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed.
2
-
-
Disconnecting the motor with centrifugal pump set and Repair/Rewinding of motor of capacity 7.5/10 HP three phase 415 Volts ,50 HZ by rewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed.
1
-
-
Disconnecting of startor and Replacement of unserviceable/ burned spare parts robust 4 pole contactor type TC1-DX/ over load relay type LR3DM/ auto start switch with Auto/manual start DIP switch, voltmete with 3P selector switch & TP MCB for Short circuit protection, suitable for relay range 12 to 25 Amps etc complete all as specified and directed.
4
-
-
S&F in repair cast iron Butterfly Valve 100mm bore , SS dise type with hand lever operated, lining test pressure PN 1.6 ISI marked including welding work with all fittings such as nuts , bolts, washers and rubber gasket etc complete in all respect all as specified.
2
-
-
S&F in repair cast iron Butterfly Valve 80mm bore , SS dise type with hand lever operated, lining test pressure PN 1.6 ISI marked including welding work all fittings such as nuts , bolts, washers and rubber gasket etc complete in all respect all as specified.
2
-
-
Maintenance ,Repair and servicing, including of testing of vertically mounted Thermic Fluid Heater (TFH) capable of delivering a heat output 100000 K Cal/Hr, one working and one stand by ) total 04 Unit using HSD oil complete in all respect, including following item of work:-
(a) Heater unit : heat exchanger, consisting of closely wound, helical, concentric coils, arranged to give adequate no of passes on flue gas side & made out of ERW tubes, confirming to IS 3059 Pt-I, suitable for high temperature all as per manufacturer design and of required head and capacity.
(b) Pressure jet burner : suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity.
(c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity.
(d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contractors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity.
(e) Circulating Pumps : Centrifugal Thermic fluid circulating pumps suitable for high temp operation, coupled with electric motor drive, mounted on common base frame all as per manufacturer design and of required head and capacity.
(f) DE Tank : Derator cum expansion tank consisting of expansion, derator and buffer vessels , guage glass assembly and level switches. Nozal for inlet and outlet on derator for drain on buffer vessel and for overflow, air vent and topup on expansion vessel all as per manufacturer design and of required head and capacity.
8
-
-
Supply only in replacement of spare parts 33.01 to 33.12 complete all as specified and directed Engr-in- charge.
-
-
-
Temp controller-TC513
4
-
-
Sequence controller-LOA 24 171b27
6
-
-
Photocell-Qrb-1A
4
-
-
Fuel pump-D57a
4
-
-
igniation transformer
4
-
-
spark plug
20
-
-
Burner inlet out let pipe
12
-
-
Burner relay
10
-
-
solonied valve
2
-
-
Contactor 10/16 Amps
10
-
-
temp control
20
-
-
Blower Moter for boiler 1/8 HP
20
-
-
S&F in repair single phase permanently lubricated 1/2 HP-62 watt for indoor unit of central Air heating plant complete all as specified and as directed.
Make : GE motor India PVT Ltd- Model NO 5KCP 29DG686 or its equivalent.
3
-
-
S&F in repair of solenoid valve suitable for indoor unit of central heating plant complete all as specified and as directed.
1
-
-
S&F in repair SPE echo frame -ignition transformer - COFIE 820-T-120 complete all as specified and as directed.
3
-
-
Repair and sevicing of suspended / wall mounted type fan coil units constructed out of 20 SWG GI casing powder coated, with two no air blowers motor driven, 3rd heating coil, 12 mm thick pre filter with drain pan insulated with 12 mm thick closed cell nitric insulation of 1.0 Ton capacity including inlet/outlet valves, air guage valve, thermostatic control with all connected accessories and fitting required, suitable match with model of thermex plants incl internal wiring with PVC insulated flexible copper conductor cable of appropriate size including taking down all as specified and directed at site by Engr-in-Charge.
15
-
-
Repair and servicing of suspended / wall mounted type fan coil units constructed out of 20 SWG GI casing powder coated, with two no air blowers motor driven, 3rd heating coil, 12 mm thick pre filter with drain pan insulated with 12 mm thick closed cell nitric insulation of 1.5 Ton capacity including inlet/outlet valves, air guage valve, thermostatic control with all connected accessories and fitting required, suitable match with model of thermex plants incl internal wiring with PVC insulated flexible copper conductor cable of appropriate size including taking down all as specified and directed at site by Engr-in-Charge.
25
-
-
Servicing of hot water boiler, disconcting electric drain out water opening of burner chamber boiler asembly, al accessories and mounting taking out helical coil of make-alfa therm hot generator 100000K Cal / Hrs, cleaing of combustion chamber reparing/ replacement of any unsv part as specified in each it complete all as specifeid and directed , ms mentioned. Note:-The job shall be carried out during entire period of contract. Repair of hot wate boiler of cqapacity 100000K cal/Hr including repair / replacement of following parts from item No. (39.01) to (39.22) to make it functional as specified and directed by Engr-in-Charge.
8
-
-
Supply only in replacement helical coil asembly complete all as specified and as directed by Engr-in- charge.
2
-
-
Supply only in replacement input ignition transformer 220 volts of output 11KV to 14 KV complete all as specified and as directed by Engr-in-charge
3
-
-
Supply only in replacement gasket suitable for hot water boiler complete all as specified and as directed by Engr-in- charge.
4
-
-
Supply only in replacement sequence controller for hot water boiler complete all as specified and as directed by Engr-in- charge.
4
-
-
Supply only in replacement refactory plate as per sample complete all as specified and as directed by Engr-in- charge.
4
-
-
Supply only in replacement of differential pressure Gauge- 0 to 10 Kg/ Cm square suitable for hot water boiler complete all as specified and as directed by Engr-in- charge.
5
-
-
Supply only in replacement of photo cell for hot water boiler complete all as specified and as directed by Engr-in- charge.
4
-
-
Supply only in replacement motorised barrel pump of capacity 1 HP , 2850 RPM, Single phase with rubber hose pipe 15 RM complete with all accessories complete all as specified and directed by Engr-in-Charge . Make: Bharat, Kirloskar
4
-
-
Supply only in replacement gate valve of capacity 50mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash.
3
-
-
Supply only in replacement gate valve of capacity 40mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash ISI marked.
3
-
-
Supply only in replacement solenoid valve for hot water boiler complete all as specified and as directed by Engr-in- charge
4
-
-
Supply only in replacement of fuel TPL pipe to buring assembly for hot water boler complete all as specified and as directed by Engr-in- charge
5
-
-
Supply only in replacement of fuel filter assembly 1/2 Ltr capacity with filter complete all as specified and as directed by Engr-in- charge
4
-
-
Supply only in replacement burner of boiler for 1 L K cal make ecoflame or equivelant or as per sample complete all as specified and as directed by Engr-in- charge
1
-
-
S&F in repair starting panel of boiler for 1 LK cal make as per sample Rapid cool complete all as specified and as directed by Engr-in- charge
2
-
-
S&F in repair electronic buzzer for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge
2
-
-
Replacement of Gun-metal, globe or gate valves, 40mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
5
-
-
Replacement of Gun-metal, globe or gate valves, 50mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge.
5
-
-
S&F in repair MNX 9 contacter type for hot water boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
4
-
-
Supply only in replacement Bimetallic relay of 3 to 5 Amp for hot water boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
4
-
-
Supply only in replacement single phase preventer for hot water boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
4
-
-
Supply only in replacement control module for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge
5
-
-
S&F in testing and commissioning of centrifugal pump set of capacity 3 HP, 3 phase , 415 Volt, 50 HZ & discharge, Head 22 to 33 m, size 50x40mm, dischare 4.5 to 2.5 l/s asspecified and directed by Engr-in-Chage.
3
-
-
Taking down old unsv cable and supply and laying of PVC insulated sheathed 6 sqmm, 3 core flate multi strand copper conductor cable complete all as specified and directed by Engr-in-Chage.
120
-
-
S&F in repairs of nozzel for WHB as specified and directed by Engr-in-Chage
5
-
-
S&F in repairs reducer nipple for WHB as specified and directed by Engr-in-Cahge.
5
-
-
S&F teflon tape for WHB as specified and directed by Engr-in-Chage.
5
-
-
M&L pump motor of capcity 5 HP with super enamled copper and wire of same gauge etc using best quality of insulation materuals turning polishing of motor shaft by machining, of bearing -02 Nos including all necessary parts make the equipment functional, as per existing model complete all as specified and as directed by Engr-in-Chage.
3
-
-
M&L for Repair of pump up to 5 HP with replacement of different unsv parts including all necessary repair work to make the equipment fully functional, as directed by Engr-in-Chage. Note:- Spare parts to be replaced for this item will be measured and paid separately.
3
-
-
Supply only in replacement of following item as required for overhauling/ repairing the centrifugal pump set under srl item No. 47.01 to 47.06.
-
-
-
Impeller
2
-
-
Pump shaft
2
-
-
Thrust Bearing
2
-
-
Water seal
2
-
-
NRV
2
-
-
Bushing
2
-
-
M&L for & cleaning of water tank of capacity 10,000 ltr PVC insulated sintex tank using cleaning solution and de-silting as specifed and directed by Engr-in-chage.
4
-
-
S&F in repair star delta starter suitable for 5 HP submersible pump as specifed and directed by Engr-in-chage.
1
-
-
S&F in repair star delta starter suitable for 10 HP submersible pump as specifed and directed by Engr-in-chage.
2
-
-
S&F in repair star delta starter suitable for 3 HP submersible pump as specifed and directed by Engr-in-chage.
1
-
-
M&L in repair K-flex for following MS/ GI pipe 19 thick K-flex insulation including jointing and fixing material such as tape insulation self adhesive with aluminium cladding size of aluminium cladding is not less than 0.1mm
-
-
-
80 mm dia
72
-
-
50 mm dia maek: K-flex/ superion
42
-
-
M&L in repair K-flex for following MS/ GI pipe 19 thick K-flex insulation including jointing and fixing material such as tape insulation self adhesive with aluminium cladding size of aluminium cladding is not less than 0.1mm
-
-
-
40 mm & 25 dia
175
-
-
20 mm & 15 mm dia
100
-
-
S&F steel water tube medium grade galvanised with all fittings including short lengths, laid in trenchs/ floors / wall with all fittings (such as bends, elbows, Tee, short, pieces, connectors, back nuts, diminishingpieces, caps and plugs, nuions etc.) following size as specified.
-
-
-
50 mm dia
160
-
-
40 mm dia
450
-
-
25 mm dia
350
-
-
20 mm dia
350
-
-
15 mm dia
250
-
-
Supply and fixing of Gun metal globe PVC / gate valve from the pipe line and supply and fixing of gun metal globe gate valve (ISI) marked with iron wheel head, screwed both ends for iron pipe all as specified and as directed for the following sizes:- ( Make: Leader / BIR / Zoloto / TATA / KSB / Kartar / Kirloskar)
-
-
-
80mm dia
4
-
-
50mm dia
10
-
-
40mm dia
15
-
-
20mm dia
15
-
-
15mm dia
25
-
-
S&F Bends up to 100 bore (any type.radius and angle tappers any type,(Straight) ,bend,increasing,decreasing.or double socket etc Tee pieces single branch."Y" junction ,double branch ,cross (all socket or socket and spigot ) colars ,caps and plugs.
150
-
-
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and getting out, complete all as specified and directed by Engineer-in-Charge
180
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
140
-
-
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
40
-
-
Taking down of existing MS sheet hot water storage 1500 Ltrs tubular tank from the mounting and checking it forany leakages , damges etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wraping with insulation at the existing height and dully fixing with fastner, nust and bolts etc complete all as specified and directed by Engr-in-chage.
2
-
-
Supply and laying of PVC insulated sheathed multi starnded copper conductor cable 10 sqmm , 4 core mutistandard copper conductor cable complete all as specified and directed by Engr-in-charge.
120
-
-
S&F in repairsof GI socket 20/25 MM complete as per existing size all as specifeid and as directd
40
-
-
S&F in repair of GI socke40/50 MM complete as per existing size all as specifeid and as directd
50
-
-
S&F in repairs of MCB single pole 240 volts 6 to 32 amps C' Curve, with rupturing capacity 10 KA, all as specified.
10
-
-
S&F in repairs of MCB SPN 240 Volts 40 Amps with rupturing capacity 10KA complete all as specified and as directed.
5
-
-
S&F in repairs of MCB Tripple pole 240 Volts 40 Amps with rupturing capacity 36KA complete all as specified and as dierected .
5
-
-
S&F in repairs of MCB Tripple pole 240 Volts 63 Amps with rupturing capacity 36KA complete all as specified and as directed .
12
-
-
M&L for lagging / insulation of pipe in repair of GI pipe including plumbing etc if required with 25mm thick bounded mineral wool pre sections 'SNAP ON' pipe sections of denicity 144 Kg/cum conforming to IS-9842 for 50mm dia GI pipe including chicken mesh wire netting 25 mm gauge, 20mm mesh added and with alluminium foil of .01 mm 15/20mm GI pipe suitable complete all as specified and directed.
150
-
-
S&F in repair of Stop valves,cast copper alloy screwed down high pressure with crutch or butterfly handel screwed both ends for iron pipe or for brass ferrule and fixed for 25 mm bore pipe,complete all as specified and directed at site.
5
-
-
S&F in repair of Stop valves,cast copper alloy screwed down high pressure with crutch or butterfly handel screwed both ends for iron pipe or for brass ferrule and fixed for 20 mm bore pipe,complete all as specified and directed at site.
5
-
-
S&F in repair of Off Load Change over switch 200 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
2
-
-
S&F in repair Off Load Change over switch 400 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
2
-
-
S&F in repair Off Load Change over switch 100 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
3
-
-
Dismentalling of squirrel cage induction of motor capacity 3 HP ,440 volts 1500 RPM and rewinding with supper enamelled copper conductor wire as per existing gauge and Nos of turns including insulation material and taking out from its orginal position and transportation from site to workshop complete all as directed.
2
-
-
S&F in repair up to 3 HP motor complete rewinding and replacing condensior ,fan complete as per existing Model all as specified and directed by Engr-in- charge.
4
-
-
S&F in repair 5 HP motor with long shaft ,3 phase, 415 volt, 50 Hz complete as per existing Model complete all as specified and directed by Engr-in- charge.
3
-
-
M&L in repair of wiring for circuit 2 core 2.5 sqmm copper conductor flexible cable PVC insulated PVC sheated as per is 694 up to date all including one earth wire drawing through PVC surface conduit making connection with LED Building security Light/ tower light / fitting etc complete all as specified and as directed by enginer in charge .
120
-
-
M&L in repair of wiring for circuit 3 core 4.0 sqmm copper conductor flexible cable PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC surface conduit making connection with LED Building security Light/ tower light / fitting etc complete all as specified and as directed by enginer in charge .
179
-
-
M&L in repair of wiring for circuit 3 core 6.0 sqmm copper conductor flexible cable PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit making connection with LED Building security Light/ tower light / fitting etc complete all as specified and as directed by enginer in charge .
123
-
-
Supply and fix in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of including necessary electric connection 2.5 sqmm 3 core pvc insulated PVC copper cable as per manufacture's requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.Cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips
1
-
-
Taking down/ dismentling the old / UNSV duct of central AC plant and M&L to assembly/ eroction of GI sheet with C&SS , rectangular / boxed, incls all accessories such as corner, cleat , carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 26 gauge . In Laid Wool installation not less than 30 mmthick over all surrounding the duct and 15 mm thick cement randering work over / around the complete duct with chicken wire mess of suitable size all is specified and directed. Note: The inner size of duct is not less than existing.
55
-
-
Supply and fixed rolled mild steel Joist channel,angle or tee sections fixed independently ,with out connecting plates etc conforming to FE 410-W Quality -A alonwith welding/ riveting of specifeid shape and necessary civil /PCC work(ie 30cm below ground level and 40 cm above level )etc.complete all as specified and as directd.
150
-
-
Servising of OFR 25 watt 13 fin oil filled radiator for Noiseless and checking of heating adjustable thermostate and three heat setting featuring safety tilt and an autothermal cut off to prevent overheating complete all as specified and as directed.
40
-
-
Supply only in replacement of following item as required for radiator 83.01 to 83.04
-
-
-
Heating Adjustable thermostate
25
-
-
Three Heat setting featuring safety tilit
15
-
-
Auto thermal cut off Switch to prevent overheating
15
-
-
On off switch
25
-
-
Repair of Corded Electric Rod of 1500 watt to 2400 watt copper heat pillar portable type room heater 230 volts AC with twin hallogen rods complete all as specified and directed.
60
-
-
Supply and fixing of heater /blower heating rod halogen type warm white startrack 24 & 23 cm pin type corded electric any size any cap or as per existing size complete all as specifeed and as directed
30
-
-
M&Lof motor of capcity 1.5 HP with super enamled copper and wire of same gauge etc using best quality of insulation materuals turning polishing of motor including all necessary repair work to make the equipment functional, as directed by Engr-in-Chage.
1
-
-
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
6
-
-
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground with top edge of the earth plate not less than 2.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providing watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 10 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note : (i) (ii) The grid of earthing trhough earth strip to achieved earth resistance less than 01 ohm to 05 ohm shall be deemed into the quoted rate and no extra payment shall be made to contractor. (iii) The test point shall be made after the grid of earthing and algebric sum of of strip with GI protation pipe shall be measured after 7.5 mtr earth pit.The strip beyond the total sum shall be paid seperately (c) Earthing will be carried out in presence of users and MES rep with entire satisfaction. (d) The ground enhansing material (GEM) / chemicals shall be added with soil and the GEM/chemicals shall be deemed to be included shall be quoted rates.
6
-
-
M&L of Aluminium strip 25x 3mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed.
140
-
-
M&L of Copper strip 20x 3mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed.
160
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements