Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Construction Material
Eprocure
Opening Date9 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 2,65,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition cement concrete in ground floors and paving (unreinforced) not exceeding 15cm thickness (below or above ground floor), complete all as specified and directed.

112

-

-

... More
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pilars etc; but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.

16

-

-

... More
Earth work in excavation by mechanical means Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out in any type of soil (the excavated soil) and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed.

914.5

-

-

... More
Excavation in post holes (or similar holes) each not exceeding 0.5 cum in any type of soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering and removing surplus soil to a distance not exceeding 50m and making good surface, complete all as specified and directed.

26

-

-

... More
Plain Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate), as in foundations, filling and mass concrete, complete all as specified and directed.

142

-

-

... More
Stone walling of random rubble stone masonry, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and directed.

218

-

-

... More
Plain cement concrete 1:2:4, (nominal mix) type B-1, using 20mm graded crushed stone aggregate as in damp proof course and other similar bands, plinth courses, coping, benching, kerb, benching, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork and use of water proofing compound all as per manufacture instruction, complete all as specified. (Note: Water proofing will be measured and paid separately)

92

-

-

... More
Brickwork with sub class "B" bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed.

263

-

-

... More
100mm thick, PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate, as in flooring including, finishing the surface even and smooth, without using extra cement, complete all as specified and as directed.

628

-

-

... More
40mm thick, PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate, as in flooring laid in slope to drain out waste water including finishing the surface even and smooth without using extra cement, complete all as specified and as directed.

544

-

-

... More
Taking down cement plaster on brick or stone walls etc; including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed.

461

-

-

... More
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished the surface even and smooth without using extra cement, complete all as specified and directed.

2470

-

-

... More
Supply only liquid Integral water proofing compound.

36

-

-

... More
Hard core of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface, complete all as specified and directed.

11

-

-

... More
Providing 50mm thick, cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed.

145.5

-

-

... More
Mild steel rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc of Ge 410W (Gde E-250 Quality A), complete all as specified and directed.

20800

-

-

... More
Expended metal, welded steel wire fabric weight not exceeding 4kg per sqm, supplied and fixed complete to wood or steel members, complete all as specified and directed.

4312

-

-

... More
Butt hinges, 100mm, medium weight, cold rolled mild steel fixed to steel/angle iron frame by welding, complete all as specified and directed.

498

-

-

... More
Mild steel, 100mm pressed handles, oval type, stove enamelled black, complete all as specified and directed.

498

-

-

... More
Galvanised mild steel, wire cloth, 0.56mm, nominal dia wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staple, complete all as specified and directed.

3689

-

-

... More
MS flat iron, rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc, Fe 290 Gde E-165, complete all as specified and directed.

12784

-

-

... More
Structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W, (Gde -E-250), complete all as specified and directed.

4083.5

-

-

... More
Mild steel framed work such as grills, gratings, etc; with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders, framed balusters, walk ways, ailings, framework of water tanks and similar work con-forming to Fe.290.Gde-E-165, complete all as specified and directed.

5071

-

-

... More
Mild steel framed work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, suitable for manhole covers etc; complete all as specified and directed.

565.2

-

-

... More
Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60 mm thick of any colour and any pattern (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.

953

-

-

... More
Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.60 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.

52

-

-

... More
Providing 150mm bore RCC pipes concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in mix 1:3:6 type C-2 using 40mm graded crushed stone aggregates, complete all as specified and directed.

41

-

-

... More
Reinforced concrete pipe 150mm dia, class NP-3, laid and jointed complete with collars, complete all as specified and directed.

107

-

-

... More
PVC (SWR) floor trap, 75mm plain with grating including jointing with solvent cement, complete all as specified and directed.

60

-

-

... More
PVC (SWR) pipes, single socketed, 75mm bore, in any length with rubber ring joints, laid in floors/fixed to walls, complete all as specified and directed.

60

-

-

... More
Preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of chalk whiting on walls, complete all as specified and directed.

1911

-

-

... More
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of zink chrome primer, complete all as specified and directed.

660

-

-

... More
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of zink chrome primer, complete all as specified and directed.

2547

-

-

... More
Rotational moulded (three layered as per IS 12701) polyethylene water storage storage tank (cylindrical vertical with closed threaded top) hoisted and fixed in position including connecting inlet/outlet pipe connecting with necessary fittings all as required at site and specified in SSR part -I of capacity 1000 litres including 20mm ball brass valves, float valve high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.

2

-

-

... More
Galvanised steel, water tubing, "medium grade" 20mm, with all fittings and fixed, complete to walls and or laid under floors etc; complete all as specified and directed.

100

-

-

... More
Gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.

4

-

-

... More
Bib tap 15mm bore, brass, chromium plated, fancy type conforming to IS, screwed down, screwed for iron pipes or for brass ferrule, complete all as specified and directed.

2

-

-

... More
Machine cut kota stone slab flooring 20-25mm thick, over and including cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.

75

-

-

... More
Machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, over and including cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 10mm thick plaster in cement mortar 1:3 complete all as directed.

7

-

-

... More
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.

478

-

-

... More
Surface excavation not exceeding 30cm deep and averaging 15 cm deep getting out in any type of soil complete all as specified and directed.

617

-

-

... More
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors/fixed to walls, completion complete all as specified and directed.

30

-

-

... More
Plain Cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.

62

-

-

... More
Machine Pressed precast concrete interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, laying over and including 25mm thick sand cushion including watering and ramming (Compacted) and joints filled with sand complete all as specified and directed.

617.5

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including getting out in any type of soil and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in charge.

86

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5m in depth and not exceeding 3.00m, 1.5m in width as well as 10sqm on plan) including getting out in any type of soil and disposal of excavated earth lead upto 50m and lift upto 3m, as directed by Engineer-in charge.

86

-

-

... More
Loose filling with broken stone or boulders of gauge 80mm to 150mm in soakage pits complete all as specified and directed.

2.7

-

-

... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work; not exceeding 200mm thick (horizontal or sloping), rough finished surface of concrete flat complete all as specified and directed.

24

-

-

... More
Mild Steel TMT steel bars 10mm dia, as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooping ends and binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified.

375

-

-

... More
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.

3.5

-

-

... More
Providing precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles and set in cement mortar 1:6, complete all as specified.

1.5

-

-

... More
PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate), as in concrete bed to 150mm dia drain pipes including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified and directed.

55.5

-

-

... More
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in surface channels and drains surface complete all as specified and as directed.

8

-

-

... More
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified.

338

-

-

... More
Add or deduct from item No 57 above for each 25mm girth or part thereof over or under 30cm.

338

-

-

... More
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes of bore 300mm including packing under,and completely surrounding pipes with concrete after they are laid and tested in including necessary shuttering and supports, complete all as specified.

10

-

-

... More
Reinforced concrete pipes 300mm dia, class NP-2, laid and jointed complete with collars, complete all as specified and directed.

10

-

-

... More
Point wiring for One light/fan point controlled by one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including unaction earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed PVC conduit of not less than 20mm dia and (ISI marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed.

94

-

-

... More
All as per srl item No. 61 above but for 3 Pin socket outlet 6 Amp on independent board.

16

-

-

... More
All as per srl item No. 61 above but for 3 Pin socket outlet 6 Amp on same board.

16

-

-

... More
All as per srl item No. 61 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly.

16

-

-

... More
Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC, with outer strip complete all as specified and directed.

126

-

-

... More
Modular switch 16 Amps single pole one way 230 V, 50 Hz, AC, with outer strip complete all as specified and directed.

16

-

-

... More
Modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed.

32

-

-

... More
Modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC, flush type with outer/inner cover complete all as specified and directed.

16

-

-

... More
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and directed.

94

-

-

... More
Sheet metal enclosure double door type for MCB, TPN, DB upto 125 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link , fixing DB and making good distributed surfaces to match with existing specification complete all as specified and directed.

17

-

-

... More
Sheet metal enclosure double door type for DBs, 8 way, 240 volts, with 200 Amps, rated busbar and neutral link including chassis wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.

8

-

-

... More
Sheet metal enclosure double door type for DBs, 4 way, 240 volts, with 100 Amps, rated busbar and neutral link including chassis wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.

8

-

-

... More
MCB triple pole & neutral capacity of 100 amps, 415 volts, rupturing capacity 16 KA, complete all as specified and directed.

17

-

-

... More
MCB triple pole, 415 volt, 25 to 63 amps "C" series, with rupturing capacity 10 KA, inculding providing thimble for out going cable complete all as specified and directed.

48

-

-

... More
MCB single pole, 240 volt, 06 to 32 amps "C" series, with rupturing capacity 10 KA, inculding providing thimble for out going cable complete all as specified and directed.

64

-

-

... More
MCB single pole, and neutral 240 volt, 63 Amps "C" series, with rupturing capacity 10 KA, inculding providing thimble for out going cable complete all as specified and directed.

16

-

-

... More
Sub main wiring with four single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (4 run of cable) of size 16 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 16 sqmm two run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections, complete all as specified and directed.

120

-

-

... More
Sub main wiring with four single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (4 run of cable) of size 10 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sqmm two run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections, complete all as specified and directed.

150

-

-

... More
Sub main wiring with four single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor (4 run of cable) of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm two run as earth continuity conductor connected to commen earth and earth dolly complete including taking out existing unserviceable service connections, complete all as specified and directed.

698

-

-

... More
Earthling complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exceeding 50m, testing on completion complete all as specified & directed.

17

-

-

... More
Ceiling fan, AC single Phase. 230V, of size 1200mm sweep with blades, down rod, min Air delivery 210 CFM and service value 6.0 BEE five star rated with brushless direct current motor (BLDC) along with all electrical wire connection all as specified and directed.

10

-

-

... More
Electronic, stepped type, fan regulator 120 watt, 230 volts, 50Hz, two module complete all as specified and directed.

10

-

-

... More
LED lights fitting 1x 20W, 230V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.

30

-

-

... More
LED flood light 70 watt, 230 V, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

6

-

-

... More
LED building security light fitting 35 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, clamps, suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including GI pipe of 25mm dia, medium grade, 1.2m long, bent to shape as per site requirement, complete all as specified and directed.

8

-

-

... More
Supply, Testing and Commissioning Powder coated Turbo Ventilator (motorized roof exhaust fan), made up of stainless steel , maintenance free, Rain and storm proof, complete all as specified and as directed (i) Motor Capacity 1 HP,RPM-1440, single phase, Sweep size -600mm. (ii) Structure mounting & Blade made up of FRP (Fibre) based high quality resin (iii) Motor Mounting Base Frame of Powder coated mild steel (iv) Air discharge 6500 CFM -10000 CFM. (v) Fan Canopy made up of FRP (Fibre) based high quality resin. (vi) Metallic net provided on both side of structure for the protection of birds and animals. Complete all as specified and as directed

48

-

-

... More
GI Tubes, "medium grade" with all fittings, laid in trenches, of size 40mm bore, complete all as specified and directed.

90

-

-

... More
GI Tubes, "medium grade" with all fittings, laid in trenches, of size 25mm bore, complete all as specified and directed.

140

-

-

... More
Gun metal gate valve 40mm dia cast copper alloy screwed down high pressure screwed both ends for iron pipe or for union and fixed, complete all as specified.

1

-

-

... More
Gun metal gate valve 25mm dia cast copper alloy screwed down high pressure screwed both ends for iron pipe or for union and fixed complete all as specified.

6

-

-

... More
Cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary excavation and earth work including repairing the same with pre mix bituminous carpet, complete all as specified and directed.

10

-

-

... More
Cutting of existing GI/CI water main pipe line upto 100mm bore in position for making branch connection (insertion of GI Tee) including excavation and earth work complete all as directed.

1

-

-

... More
Construction of brick masonry valve pits of size 0.5m x 0.5m x 0.6m) internal dimension with brick work in cement mortar (1:4) including excavation and earth work, concrete work, 3mm thick MS sheet cover with locking arrangement hinges and handle, rendering work, painting to all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and as specified.

1

-

-

... More
Supply, installation, testing and commissioning factory made (CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following:- Incoming (a) MCCB 160 Amps, 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No. Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set

2

-

-

... More
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fitted with solid busbar connectors (iv) Cables shall be terminated using gun metal /SS glands and including suitable thimbles/lugs, nut bolts, washers fitted the cables, cable glands suitable for incoming and outgoing LT cable is including rate quoted by contractor.

-

-

-

... More
Supply, installation, testing and commissioning factory made (CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following:- Incoming (a) On load Changeover 160 Amps, 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No. Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set

1

-

-

... More
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fitted with solid busbar connectors and (iv) Cables shall be terminated using gun metal /SS glands including suitable thimbles/lugs, nut bolts, washers fitted the cables, cable glands suitable for incoming and outgoing LT cable is including rate quoted by contractor.

-

-

-

... More
Supply, installation, testing and commissioning factory made (CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following:- Incoming (a) MCCB 100 Amps, 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25/26 KA-01 No. Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 150 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set

1

-

-

... More
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fitted with solid busbar connectors and (iv) Cables shall be terminated using gun metal /SS glands including suitable thimbles/lugs, nut bolts, washers fitted the cables, cable glands suitable for incoming and outgoing LT cable is including rate quoted by contractor.

-

-

-

... More
Supply, installation, testing and commissioning factory made (CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following:- Incoming (a) MCCB 63 Amps, 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25/26 KA-01 No. Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 100 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set

2

-

-

... More
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fitted with solid busbar connectors and (iv) Cables shall be terminated using gun metal /SS glands including suitable thimbles/lugs, nut bolts, washers fitted the cables, cable glands suitable for incoming and outgoing LT cable is including rate quoted by contractor.

-

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 185 Sqmm, 3.5 core complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

300

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 150 Sqmm, 3.5 core complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

255

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 120 Sqmm, 3.5 core complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

300

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

310

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

260

-

-

... More
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 25 Sqmm, 3.5 core, complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid for separately complete.

315

-

-

... More
Galvanised steel tubing, light grade, 80mm dia for protection of under ground cable on poles / walls under road crossing etc, complete all as specified and directed.

40

-

-

... More
Boring of existing road/path for laying of GI pipe protection for UG cable including making good disturbed area/surface, complete all as specified and directed.

40

-

-

... More
150 Amps, copper bus bar with enclosure wall mounted size (300X250)mm, suitable for 415 volts 3 phase, 4 wire , 50 Hz, AC, dust and vermin proof, made of 1.8 mm ,CRCA, MS sheet for cable entry and locking arrangement complete all as specified and directed.

10

-

-

... More
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.

7

-

-

... More
Double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable complete all as specified and directed.

600

-

-

... More
Double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable complete all as specified and directed.

550

-

-

... More
Supply, fixing, Testing and Commissioning Organic Waste Shredder (Capacity to shred all types dry & semi wet agricultural/kitchen produce bio mass, wood sticks, coconut leaves etc in to small pieces for compost) , with motor capacity upto 10 HP single shaft type , Three phase Supply, 440 Volt,50 Hz, working/shredding capacity -500 Kg /Hr, complete all as specified and as directed.

1

-

-

... More
Supply, fixing, Testing and Commissioning Kill Waste Machine 250 Kg/Hour Fuel-Free Solid Waste Disposal System with pollution control device, complete all as specified and as directed (i) Material- Non-Corrosive mild carbon steel of IS2062-GRADE B category Cylindrical Chamber as specified by BIS. (ii) Pollution Control Device: Multi-Level Wet Scrubber, with activated charcoal filter, baffle filter, emission testing port. (iii) Chimney made up of Stainless Steel (iv) Additional Neck Reinforcement for storm proof (v) Necessary Thermal Insulation of (Cement concrete, Fire brick, Glass wool, Aluminium sheet) (vi) Body Parts as following: (1) Upper cone (2) Cylindrical Chamber (3) Lower cone (4) Loading door (5) Inspection door (6) Ash door. Note: OEM should produce certificate and test report of emissions as per SWM rule 2016 after installation

2

-

-

... More
Supply, fixing, Testing and Commissioning Wet Waste Shredder (capacity to shred Organic waste, Wet waste ,Kitchen waste etc) dual shaft with motor capacity of 15 HP (7.5 HP x 2) , 3 Phase supply, (440 Volt/ 50 Hz) shredding capacity -500 Kg/Hr, Harden Blade material of high quality, complete all as specified and as directed.

2

-

-

... More
Supply, fixing, Testing and Commissioning Industrial Grade Fly Catcher/Insect Killer Machine , comprises of fitting on Wall/Ceiling, UV Tubes ( 4 x 20 W), Power Consumption Upto 100 W, Effective area Open approx. 900 sq ft , Design for high Roof Area, Heavy and strudy, Big size bottom tray to collect dead insects, MS Epoxy powder coated body, complete all as specified and as directed

40

-

-

... More
Deduction to be made from BOQ for Sch 'A' Part -II (Schedule of credit) Amount of Rs. 2,18,450.00 during AOC. Note: Tenderers shall not quote for this schedule.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.