Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date10 Jan 2025
Closing Soon1 Feb 2025
Tender Amount₹ 32,50,000
Costs
EMD
₹ 65,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692623_1Tender No
GER-75/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.
(Note: Punned thickness of sand shall be measured and paid).
51
-
-
... More
Supplying and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class 'B' bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and directed.
5040
-
-
... More
M&L in repair for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, lightening protectioncrossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
43
-
-
... More
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed.
(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
120
-
-
... More
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed.
(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
90
-
-
... More
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed.
(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
220
-
-
... More
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed.
(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
180
-
-
... More
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed.
(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
120
-
-
... More
Supply, Fixing and testing of street light control panel digital 24 Hrs timer of Max load 6 KW, in an inlcuding of contactor rating 32Amp TP, MCB 40Amp TPN, three phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed.
2
-
-
... More
Supply, Fixing and testing of street light control panel digital 24 Hrs timer of Max load 6 KW, in an inlcuding of contactor rating 432Amp TP, MCB 40Amp SPN, single phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed.
2
-
-
... More
S&F for decorative LED Bollard light with diffuers outdoor type LED Bollard light 9W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable including taking out old bollard light, complete as in repair all as specified and directed.
15
-
-
... More
S&F in repair for LED 15 watt bush and spike light luminaire with IP-65 protection complete with all accessories duly prewired and connecting with PVC insulated, sheathed flexible copper conductor cable 3 core 0.5 sqmm of adequate length from looping box to light fitting, complete as in repair all as specified and directed.
6
-
-
... More
S&F in repair for LED post top lantern light fitting 20 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete as in repair all as specified and directed.
25
-
-
... More
S&F in replacement for LED street light fitting 35 watts dusk and down type, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, complete all as specified and directed.
473
-
-
... More
S&F in replacement for LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, complete as all as specified and directed
300
-
-
... More
S&F in replacement for LED street light fitting 72 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, complete all as specified and directed.
245
-
-
... More
S&F in replacement for 72 watt 230 volts, LED flood light luminaire AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
25
-
-
... More
S&F in replacement for 180 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc, complete all as specified and directed.
18
-
-
... More
M&L in replacement for GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers, complete all as specified and directed.
30
-
-
... More
S&F for FRP looping box of size 200x140x95 with aluminium bus bar (04 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed.
60
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed.
(Note:-Earth strip, earthwork and protection pipe upto board is included in the rate quoted)
2
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed.
(Note:-Earth wire, earthwork and protection pipe upto board is included in the rate quoted)
2
-
-
... More
S&F in repair for rigid Non metallic PVC conduit of 25mm dia (medium grade) including conduit accessories for encasing the cable from looping box to streel light fittings on PCC poles/on wall surfaces as per site requirement with necessary base saddles etc. all as specified and directed
260
-
-
... More
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable complete all as specified and directed.
260
-
-
... More
M&L for complete removal of existing paint from the steel tubular swaged pole of 9 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each and winding of reflective strip of 10 cm on each pole, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed.
37
-
-
... More
Window AC M & L for repair and maintenance including disconnecting, taking down & refixing of window type AC's of capacity 1/1.5 TR comprising of the following works at different locations & including refixing, commissioning, testing, complete all as specified and directed :-
(i) Inspecting, taking down, brushing cleaning with blower & including acid/detergent wash of condenser and cooling coil.
(ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts.
(iii) Inspecting for leakage in the system.
(iv) Checking the earth continuity of electrical parts.
(v) Checking the functioning of thermostat.
(vi) Inspection of all electrical parts.
(vii) Testing the machine for satisfactory operation.
Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of window type AC.
9
-
-
... More
S & F in replacement of air filter of window type AC of capacity 1/1.5 TR as per existing Make & Model as required at site complete all as specified and directed.
4
-
-
... More
M & L for cooling coil as per existing Make and Model for window AC 1/1.5TR & including soldering/welding, commissioning & testing, complete all as specified and directed.
3
-
-
... More
Disconnecting & taking down of window type AC 1/1.5 TR of any Make and re-fixing the same after replacement of condenser coil as per existing make and model & including soldering/welding, commissioning & testing complete all as specified and directed.
4
-
-
... More
S & F in replacement of fan and blower motor as per existing make & model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
4
-
-
... More
S & F in replacement of fan and blower motor as per existing make & model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
3
-
-
... More
S & F in replacement of blower as per existing make & model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
4
-
-
... More
S & F in replacement of blower as per existing make & model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
3
-
-
... More
S & F in replacement of fan blade as per existing make & model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
4
-
-
... More
S & F in replacement of fan blade as per existing make & model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
4
-
-
... More
Split AC M & L for servicing and maintenance of split type AC's of capacity 1 TR/ 1.5 TR/ 2.0 TR comprising of the following works & installed at different locations & including testing complete all as specified and directed :-
(i) Checking and rectifying the Indoor/outdoor units for noise free operation.
(ii) Checking and rectifying the electrical connection & water leaking problem.
(iii) Cleaning the Out-door unit condenser and In-door unit cooling coil with air blower and latest technology cleaning system.
(iv) Greasing/Oiling of condenser fan motor and blower motor.
(v) Checking and rectifying for any kind of refrigerant leakage.
(vi) Checking the serviceability of remote control unit.
Note:- (i) Any parts found unserviceable/defective rectified/changed shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make(s) of AC's to be repaired are specified in Appx 'D'. (Voltas, Hitachi, Lloyd, Godrej, Bluestar) (iv) Providing Common tools, Special Tools, latest cleaning devices and Connected accessories is the responsibility of contractor.
14
-
-
... More
S & F in replacement of capacitor combo running 36/45 mfd for split/ window type AC unit as per existing as required at Site, complete all as specified and directed.
8
-
-
... More
S & F in replacement of running capacitor 60/80 mfd for split/window type AC unit as per existing as required at Site, complete all as specified and directed.
6
-
-
... More
S & F in replacement of indoor blower fan motor, single phase, 230 Volt of split/window type AC Suitable for 1.5/2 TR capacity, complete all as specified and directed.
4
-
-
... More
S & F in replacement of burnt compressor of capacity 1.5 TR of split type AC unit and re-fixing the same after replacement from the company make original compressor as per existing Rotary Type make & model and including gas charging complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
4
-
-
... More
S & F in replacement of burnt compressor of capacity 2.0 TR of split type AC unit and re-fixing the same after replacement from the company make original compressor as per existing Rotary Type make & model and including gas charging complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
3
-
-
... More
M & L for repair to leaking area of split type AC unit of capacity 1.5 TR and including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
3
-
-
... More
M & L for repair to leaking area of split type AC unit of capacity 2.0 TR and including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
2
-
-
... More
S & F in replacement of air filter of indoor unit for split type AC units of capacity 1.5 TR as per existing make & model, complete all as specified and directed.
4
-
-
... More
S & F in replacement of air filter of indoor unit for split type AC units of capacity 2.0 TR as per existing make & model, complete all as specified and directed.
3
-
-
... More
S&F in replacement of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) fixed with clamps, complete all as specified and directed.
50
-
-
... More
S & F in replacement of 3 core copper PVC insulated cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694, complete all as specified and directed.
100
-
-
... More
S & F in replacement of swing motor of indoor unit as per existing Make & model for split type AC, 1.5 TR, complete all as specified and directed.
3
-
-
... More
S & F in replacement of swing motor of indoor unit as per existing Make & model for split type AC, 2 TR, complete all as specified and directed.
4
-
-
... More
S & F in replacement of suction line (1/4") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site, complete all as specified and directed.
100
-
-
... More
S & F in replacement of discharge line (5/8") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site, complete all as specified and directed.
120
-
-
... More
S & F in replacement of PCBs indoor/ outdoor units as per existing make & model for Split type AC of Capacity 1.5 TR, complete all as Specified and Directed.
4
-
-
... More
S & F in replacement of PCBs indoor/ outdoor units as per existing Make & model for Split type AC of Capacity 2.0 TR, complete all as Specified and Directed.
4
-
-
... More
S & F in replacement of electronic cordless remote control unit as per existing Make & model of split type AC's of capacity 1.5 TR, complete all as specified and directed.
4
-
-
... More
S & F in replacement of electronic cordless remote control unit as per existing Make & model of split type AC's of capacity 2.0 TR, complete all as specified and directed.
4
-
-
... More
S & F in replacement of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR, complete all as specified and directed.
80
-
-
... More
S & F in replacement of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 2 TR, complete all as Specified and directed.
2
-
-
... More
S & F in replacement of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 1.5 TR, complete all as Specified and directed.
2
-
-
... More
S & F in replacement of outdoor unit condenser fan motor as per existing Make & model and suitable for 1.5 TR capacity air conditioner, complete all as specified and directed.
2
-
-
... More
S & F in replacement of outdoor unit condenser fan motor as per existing Make & model and suitable for 2 TR capacity air conditioner, complete all as specified and directed.
2
-
-
... More
S & F in replacement of indoor unit complete set (Refrigerant Compatibility R22, R410A & R-32) compatable with all BEE Star Ratings AC's, copper tubes in evaporator coil as per existing Make & model & suitable for 1.5 capacity air conditioner and including gas charging, complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
1
-
-
... More
S & F in replacement of outdoor unit (Refrigerant Compatibility R22, R410A & R-32) without compressor, Compressor compatibility; Rotary or Reciprocating both as per existing Make & model & suitable for 1.5 capacity air conditioner and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
1
-
-
... More
S & F in replacement of copper condenser coil as per existing and suitable for 1.5 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
4
-
-
... More
S & F in replacement of copper condenser coil as per existing and suitable for 2 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
3
-
-
... More
S & F in replacement of low pressure valve as per existing Make & model of AC, complete all as specified and directed.
10
-
-
... More
S & F in replacement of four way valve as per existing Make & model and suitable for 2.0 TR / 1.5 TR capacity of air conditioner, ISI marked, complete all as specified and directed.
8
-
-
... More
S&F in replacement of AC refrigerant charging pin NRV Valve, complete all as specified and directed.
7
-
-
... More
Shifting of Split AC's of capacity 1.5/2.0 TR with indoor, outdoor and including all the connected accessories after pumping down the gas, refitting, topping up the gas, testing and commissioning complete all as specified and directed.
5
-
-
... More
S & F in replacement of ducting insulation sheet (9mm thick) for insulating refrigeration pipe line for 1.5/2.0 TR capacity of air conditioner, complete all as specified and directed.
40
-
-
... More
S & F in replacement of brass flare union connector (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC, complete all as specified and directed.
2
-
-
... More
Water cooler M & L for servicing & maintenance of water coolers of any capacity comprising of the following works at different location complete all as specified and directed :-
(i) Inspection, taking down, opening, dismantling, descaling, brushing & cleaning of storage tanks.
(ii) Examination water tightness, leak proof of storage tank after cleaning.
(iii) Carry out operation of all stop cock, push cock, float valve etc.
(iv) Inspect overflow and remove blockage if any.
(v) Check and correct earth continuity of electric items.
(vi) Check thermostat and test its functioning.
(vii) Inspect drain pipe and remove blockage if any.
(viii) Check and correct all electrical wiring & test its functioning.
(ix) Testing of water cooler after repair.
Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of water coolers.
30
-
-
... More
S & F in replacement of thermostat switch as per existing Make & Model for water cooler of any Capcity, complete all as specified and directed.
18
-
-
... More
S & F in replacement of overload protector relay as per existing Make & Model for compressor of water cooler of any capacity as required at site, complete as specified and directed.
10
-
-
... More
S & F in replacement of condenser fan motor, single phase of 1/30 HP as per existing Make and Model & suitable for water cooler of capacity 40/80 Ltrs, complete all as specified and directed.
6
-
-
... More
S & F in replacement of condenser fan motor, single phase of 1/20 HP as per existing Make and Model & suitable for water cooler of capacity 60/120 Ltrs, complete all as specified and directed.
7
-
-
... More
S & F in replacement of 15mm bore brass float valves accessories as per existing Make and Model & suitable for water coolers at site, (ISI marked), complete all as specified and directed.
16
-
-
... More
Disconnecting and taking down water coolers of capacity 40/80 Ltrs & 60/120 Ltrs of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-22/R-134A/Environmental Friendly Gas) suitable for compressor model & testing the water cooler for smooth & satisfactory operation complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
10
-
-
... More
S & F in replacement of CP push cock of size 15mm dia as per existing Make & model, (ISI marked), complete all as specified and directed.
20
-
-
... More
S & F in replacement of capacitor 10 Mfd as per existing Make & model (ISI marked) for water cooler of any capacity, complete all as specified and directed.
25
-
-
... More
M & L for repair rusted body as per existing of water cooler and replacing MS sheet and fixing new MS sheet (size upto 1.50 Sqm) thickness 21 SWG by remitting/gas welding and including replacement of angle iron of size 35mm x 35mm x 4mm (Minimum Weight-2.5 Kg), making the broken cover lid into working condition and including painting, complete all as specified and directed.
4
-
-
... More
S & F in replacement of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 40/80 Ltrs and including gas charging, complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
3
-
-
... More
S & F in replacement of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 60/120 Ltrs and including gas charging, complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
2
-
-
... More
Deep Freezer M & L for repair & maintenance of Deep Freezer of capacity 200 to 320 Ltrs comprising of the following works at different location complete all as specified and directed :-
(i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.
(ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.
(iii) Inspecting the leakage in the system.
(iv) Checking of the earth continuity of electrical parts.
(v) Checking the functioning of thermostat.
(vi) Inspection of all electrical parts.
(vii) Testing the machine for satisfactory operation.
(viii) Check and correct all electrical wiring & test its functioning.
(ix) Testing of Refrigerator after repair.
Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Deep freezer.
10
-
-
... More
S&F in replacement fan motor of deep freezer 16 watts, 230 Volts single phase, complete all as specified and directed.
6
-
-
... More
S & F in replacement of burnt compressor as per existing Company Make original & model and suitable for deep freezer of capacity 200-320 Ltrs and including gas charging, complete all as specified and directed.
Note :- (i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate.
(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
3
-
-
... More
S&F in replacement Deep freezer 1/2 hp, 3/8 hp, 1/3 hp compressor start relay, complete all as specified and directed.
5
-
-
... More
S&F in replacement Deep freezer relay capacitor 12/15 mfd, complete all as specified and directed.
10
-
-
... More
S & F in replacement of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amps, 240 Volt, MCB, 'C' curve type with AC box, rupturing capacity 10 KA, complete all as specified and directed.
10
-
-
... More
S & F in replacement of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
30
-
-
... More
S & F in replacement of metal clad plug for all type of AC's as per existing Make and size, complete all as specified & directed.
10
-
-
... More
S & F in replacement of metal clad socket for all type of AC's as per existing Make and size complete all as specified & directed.
10
-
-
... More
Refrigeretor
Dismantling refrigerator of any make any capacity for taking out compressor/condenser/freezer unit etc. for repair/ replacement of unserviceable parts, cleaning condenser/ freezer unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas, reassembling the appliance, testing and placing in position complete all as specified and directed.
Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
10
-
-
... More
S&F in replacement hermetically sealed compressor unit 1/8 HP for 165/175 Ltr refrigerator, complete all as specified and directed.
7
-
-
... More
S&F in replacement hermetically sealed unit compressor 1/6 HP for 280 to 310 Ltr refrigerators, complete all as specified and directed.
6
-
-
... More
S&F in replacement of PCB (printed control board) and sensor, complete all as specified and directed.
8
-
-
... More
Supply and filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters, complete all as specified and directed.
10
-
-
... More
S&F in replacement of copper capillary tube of refrigerator, any description complete all as specified.
50
-
-
... More
S&F in replacement starting relay of refrigretor any capacity, complete all as specified and directed.
10
-
-
... More
S&F in replacement over load protector for refrigerator, any description complete all as specified and directed.
10
-
-
... More
S&F in replacement thermostat of refrigretor of any capacity, complete all as specified and directed.
10
-
-
... More
S&F in replacement freezer compartment including hinges for door and all petty accessories for any capacity any make refrigerator, complete all as specified and directed.
10
-
-
... More
Voltage stabilizer Dismantling electric connection of any make any capacity voltage stablizer for inspecting of burnt out relay, circuit board, etc. for repair/ replacement of unserviceable parts, testing and placing in position, complete all as specified and directed.
Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
20
-
-
... More
S & F in replacement of electromagnetic relay for capacity of 2.5 KVA stablizer, complete all as specified and directed.
8
-
-
... More
S & F in replacement of electromagnetic relay for capacity of 3 KVA stablizer, complete all as specified and directed.
6
-
-
... More
S & F in replacement of electric circuit board for capacity 2.5 KVA stablizer, complete all as specified and directed.
10
-
-
... More
S & F in replacement of electric circuit board for capacity 3 KVA stablizer, complete all as specified and directed.
4
-
-
... More
M & L of rewinding of transformer of capacity 0.5 to 5 KVA for refrigerator & AC with super enamelled copper winding wire, complete all as specified.
20
-
-
... More
Servicing of RO water purifier of 50 ltr capacity incl pump motor,Ro membrane,carbon candle,sendimentation candle,adopter,UV chamber,PCB, complete all as specified and as directed. Note : U/S items of RO will be measured and paid separately.
6
-
-
... More
Repair/replacement of RO pump motor suitable for water purifier 50 Ltrs capacity of voltage 240 V 55 W, complete all as specified and directed.
2
-
-
... More
Replacement of RO membrane 75 GPD suitable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
... More
Replacement of carbon candle suiatable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
... More
Replacement of sedimentaion candle suiatable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
... More
Replacement of adopter suitable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
... More
Replacement of UV chamber suitable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
... More
Replacement of PCB suitable for water purifier 50 Ltrs capacity, complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%