Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Dec 2023
Closing Date12 Jan 2024
Tender Amount₹ 24,98,000
Costs
EMD
₹ 49,960Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_631180_1Bid Award Id
ViewTender No
CWE/JA-26/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for fixing in replacement of ACSR conductor Size 3 of 6/1 x4.72(dog) drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre to centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Scraping of old paint from two pole structure without removing accessories and preparation of surfaces for repainting. Repainting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of alumn paint or PCC pole with snowcem of approved color all as required at site or directed.
32
-
-
... More
Material and labour for Rubber tiles 5mm thick with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive all as specified and directed.
80
-
-
... More
Trimming and cutting of tree branches coming across 33KV overhead HT line clearing around line 1.5m single/both sides and disposal of branches to distance not exc 50m and complete site all as specified and directed Note:- 1. length of span 100 to 150mtr. 2. Due care is given while cutting /trimming tree branches that there should be no damage to existing conductor/poles. In case due to negligence,damaged is caused is to make good/renewal by the contractor from his own resources and nothing extra will be admissible.
80
-
-
... More
Taking down old unsv 33 KV Isolator and M&L for rotating isolator triple pole double break capacity 33KV 630A 25 KA rotating type with earth switch gang operated outdoor having each pole has galvanised steel base, solid core or post type insulators,EC grade copper fix and moving contacts, GI coupling pipe of adequate length for rotating operation from ground level and operating handle for smooth operation, ferrous parts are hot dip galvanized and non ferrous parts are heavily tinned to withstand weather. The handle fabricated from channel, lever and turned pipe gripper with locking arrangement in both ON and OFF position all as specified and directed by Engr-in-charge.
3
-
-
... More
Taking down unsv lightening arrestor and M&L for 33KV 10 KA surge type lightening arrestor for 33000V(-15% to +10%,3 phase,50HZ(-5% to +30%) power supply. The lightening arrestor shall be line type and gapless and of non-linear resistors made of Zinc oxide having counter meter and to sustain spark over voltage upto 100 KV, withstand standard impulse voltage of 115KV,maximum residual voltage at nominal discharge capacity current shall be 100KV all as specified and directed. Make- ABB, Siemen,L&T,Electricfield
2
-
-
... More
M&L for preparation of old painted surface of outer surface of steel structure of 33 KV Grid bus bay strucure at Grid,length 30 Rm, Height 3Rm,width 7.5Rm by brushing/cleaning stain,greasy spots with thinner, incl painting on two and four pole structures in the yard applying two coats of spray painting(synthetic enamel paint) all sides with spraying machine in the yard after disconnecting power supply including writting description of equipment in block english letter 100mm size with whie and black synthetic enamel paint as per details given by deppt all as specified and directed.
1
-
-
... More
Taking down old unsv and Supply, installation, connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 200 amps and working voltage 11000 volts all as required at site or directed by Engr-in-charge. Make- Jaipuria, BHEL
4
-
-
... More
M&L for sieving out graded coarse aggrgrate and and taking out sand dust/gravel of size less than 20mm of nominal size and Supply filling and laying coarse aggregrate normal size 25mm at 33 KV Grid bay/yard , deposted spread and levelled in layers not exc 100mm thick,rammed and watered to a true surface all as specified and directed.
7
-
-
... More
M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
6
-
-
... More
Labour only for restringing of over head line ACSR of any size and upto 3 wires in a span with GI earth wire of 4 mm dia of span length 30 to 60 m to permissiable sag incl winding with Aluminium conductor and triming of branches of tree beside the span all as directed.
35
-
-
... More
Suplying and fixing in replacement of Pin type, porcelin, vitreous, white, brown or green insulator, size 150mm height, 150mm dia for 11000 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge.
35
-
-
... More
Supply and fixing in replacement of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as spd and as directed by Engineer-in-Charge.
40
-
-
... More
Supply and fixing in replacement of polymer Disc insulator with hard ware fittings 33 KV grade standard size ISI marked all as specified and directed.
40
-
-
... More
Taking down old/burnt supply, laying,jointing testing and connecting cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) of size 11KV(E) volts grade with stranded aluminium conductor ofsize 120 sqmmx3 core all as specified and directed by Engr-in-charge Make Havells,Gloster,Bolton
90
-
-
... More
Taking down old/burnt and supply, laying,jointing testing and connecting cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) of size 11KV(E) volts grade with stranded aluminium conductor ofsize 95 sqmmx3 core all as specified and directed by Engr-in-charge Make Havells,Gloster,Bolton
100
-
-
... More
Supply and fixing in replacement polymer post insulators with hardware fittings 33 KV graded all as specified and directed.
30
-
-
... More
Supply and fixing in replacement PG aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/panther/Zebra with nuts and bolts all as specified and directed.
20
-
-
... More
Supply and fixing in replacement T connector Clamp aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/panther/Zebra with nuts and bolts all as specified and directed.
20
-
-
... More
Supply and fixing in replacement rigid type terminal connector ,stud to conductor/cable aluminium cast alloy clamps suitable for existing ACSR conductors of type sheep/ panther/ Zebra with nuts and bolts all as specified and directed.
20
-
-
... More
M&L for centifuging and dehydration including filteration and cleaning of transformer oil of 33/11KV, 3.15MVA Transformer on site on load by dehydrattion machine including sample before and after dehydration and filteration oil all as specified and directed( contractor shall have to arrange dehydration machine and testing kit at his own resources all is specified and directed.
1000
-
-
... More
Supply and filling of top up of transformer oil in transformer of die-electric strength not less than 60 KV(AT 2.5MM gap) at high voltage of IS specification of low viscosity.(Note:- Transformer oil should be provided in sealed container) Make HP,BPL,Oil corporation of india
400
-
-
... More
Supply and fixing in replacement metal heavy duty Exhaust fan 450 mm, Single phase complete with louvre all as specified and directed.
1
-
-
... More
M&L for Cable end termination joint outdoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 185sqmmx3 core cross sectional area including testing and commissioning etc complete all as specified. Make-Raychem, Denson
3
-
-
... More
M&L for Cable end termination joint indoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 240 sqmmx3 core cross sectional area including testing and commissioning etc complete all as specified. Make-Raychem, Denson
3
-
-
... More
M&L for Cable end termination joint indoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 50 sqmm to 95sqmm core cross sectional area including testing and commissioning etc complete all as specified. Make-Raychem, Denson
4
-
-
... More
M&L for Cable end termination joint indoor cold shrinkable type suitable for stranded aluminium conductor 3 core,11 KV XLPE of 240 sqmmx3 to 300 sqmm core cross sectional area including testing and commissioning etc complete all as specified. Make-Raychem, Denson
4
-
-
... More
M&L in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified. Make-Raychem, Denson or equivalent
4
-
-
... More
Disconnecting all HT connection of VCB panel and Taking down exisitng unsv/ broken vaccum interupter and Supply and fixing vacuum interupter suitable for indoor VCB 11KV 800 Amp as per sample of Make CG all as specified and directed.
3
-
-
... More
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole and laying of HT cable as in soft/loose soil and getting out complete all as specified and directed.
76.95
-
-
... More
Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
54.07
-
-
... More
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point
22.88
-
-
... More
Supply and laying sub class 'B' bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
1.08
-
-
... More
Material and labour for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed.
14.48
-
-
... More
M & L for cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete.
3.24
-
-
... More
M & L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundation, filling and mass concrete
0.22
-
-
... More
Taking out after disconnection of existing old protection relay, Multifunction meter, master trip relay, T&C switch, all indications and selector switches from VCB panels, complete all as specified and directed.
2
-
-
... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
5
-
-
... More
Supply, Erection, wiring, testing and commissioning of new static under Voltage relay, voltage setting & time setting, complete all as specified and directed. Make:- L&T/ Schneider / ABB
5
-
-
... More
Supply, Erection, wiring, testing and commissioning of new Trip Circuit Supervision relay, complete all as specified and directed. Make:- L&T/ Schneider / ABB
5
-
-
... More
Supply, Erection, wiring, testing and commissioning of new Master Trip relay, complete all as specified and directed. Make:- L&T/ Schneider / ABB
5
-
-
... More
Dismantling existing old 30 VDC battery bank-1&2 and Supply, erection, wiring, testing and commissioning of new maintenance free 30 V DC battery bank-1&2 by providing 16 cells of 2.0V, 100 AH rating each and laying of new 2Cx16 sqmm copper cables, PVC sheathed, PVC insulated, armoured having core color code red and black, freuling and termination, complete all as specified and directed. Battery Make :- Exide/ Amron or equivalent, Wire Make :- KEI/ Havells or equivalent
2
-
-
... More
Supply, installation, testing in replacement of Battery Charger new components of 32 V DCDB cubicle viz. 2 pole DC MCBs, voltmeter, ampere meter, wiring, cabling, ferruling and termination. a) Double pole MCB for controlling DC supply b) Digital Voltmeter DC, range: 0-50V DC c) Digital Ampere meter DC, range: 0-30A DC Make :- Sasa / panasonic/ Exide/Luminous
2
-
-
... More
Supply and fix and in repair 11 KV out door type Air Break gang operated device of rating 400 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators 15 Nos, incl drop out fuse assy and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply cand testing complete all as specified and directed. Make :- Atlas/Elpro/ECE/Pactil/Oblum
2
-
-
... More
Supply and fixing trip coil , closing coil, 30 Volts DC suitable for 11KV VCB, complete all as specified and directed.
7
-
-
... More
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of ₹ 109500.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements