NHPC Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
NHPC Limited - NHPC Tender
Eprocure
Opening Date7 Mar 2019
Closing Date15 Apr 2019
Tender Amount₹ 1,41,25,863
Costs
EMD
₹ 2,83,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_NHPC_451293_1Bid Award Id
ViewTender No
NH/KG/ELECT/PandC/PKG-194Tender Authority
NHPC Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Distribution of Power Supply from 33/0.44 KV Sub-Station to Office cum Residential Complex through cable and feeder pillar at Kishanganga Power Station, Kralpora, Bandipora
BOQ FOR Distribution of Power Supply from 33/0.44 KV Sub-Station to Office cum Residential Complex through cable and feeder pillar at Kishanganga Power Station, Kralpora, Bandipora
Tender document for Distribution of Power Supply from 33/0.44 KV Sub-Station to Office cum Residential Complex through cable and feeder pillar at Kishanganga Power Station, Kralpora, Bandipora
BOQ Items
Strctural steel work in single section fixed without connecting plate including cutting ,hoisting, fixing in position and applying a priming coat of approved steel '" primer all complete.
11338.21
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer-in-charge.Made of G.I. wire of dia 4mm
299
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centring shuttering- All work upto plinth level. And 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size)) Nallah
94.25
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
288.41
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
2488.2
-
-
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centring shuttering, finishing smooth with 6mm thick cement plaster 1:3 ( 1 cement: 3 fine sand) on exposed surfaces complete but excluding cost of reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size).
79.17
-
-
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
22463.92
-
-
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and the like not exceeding 10sqm on plan, depth upto 1.5mtr. including disposal of excavated earth upto 1mtr from cutting edge, disposed earth is to be levelled and neatly dressed in: All kinds of soil
960.4
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.100 mm dia
72
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.150 mm dia
29
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.250 mm dia
54
-
-
Supplying, cutting and fixing of appropriate size of U-PVC pipes (conforming to 15-13592) Single socketed pipe 110 mm dia.
113
-
-
Supplying, cutting and fixing of appropriate size of 20 mm dia. ISI marked, PVC conduit
1206
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 70 sqmm,1100v grade as per IS7098
230
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 120 sqmm,1100v grade as per IS7098
523
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 150 sqmm,1100v grade as per IS7098
100
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 185 sqmm,1100v grade as per IS7098
549
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 240 sqmm,1100v grade as per IS7098
1757
-
-
Supply of PVC Sheathed PVC insulated Armoured Aluminium cable of size 3.5core 300 sqmm,1100v grade as per IS7098
1005
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm)
6
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 150 sq. mm (50mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62mm)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 300 sq. mm (70mm)
8
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
59
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
1110
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
2228
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
19
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm
103
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
204
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
149
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
247
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA-01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16kA-03 Nos, MCCB 63A 4P 16kA-02 Nos. 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 400A 4P 35KA - 02 Nos. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16kA-06 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 800A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16kA-05 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16KA-03 Nos,MCCB 63A 4P 16KA-02 Nos. 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 200A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 200/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-08 Nos. 01 No 10A 3 pin socket outlet with 10A switch and one no brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 400A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16kA-07 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 500A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-05 Nos. 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 100A 4P 16kA-05 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 400A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 160A 4P 16kA-01 Nos,100A 4P 16kA-02 Nos,63A 4P 16kA-02 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 500A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 320A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-07 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 400A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 250A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 250/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-07 Nos. 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 300A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 400A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-06 Nos, MCCB 160A 4P 16kA-01 No, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 500A Capacity
1
-
-
Fabrication,Supply,Installation,Testing & Commissioning of LT Outdoor Feeder Pillar (1500mmx1400mmx450mm)double door( Front & Back) with provision of gasket, fabricated by 14SWG(2.00mm) thick CRCA Sheet & mounted on angle iron frame(Feeder Pillar Leg size 600mm) powder coated paint, dust & vermin proof with provision of earthing with 25x6mm GI strip on both sides of feeder pillar. Feeder Pillar shall be of Class IP-55 with lifting hook for easy handling of feeder pillar & provided and fitted with following equipments and accessories:- Incomming: MCCB 400A 4P 35KA - 01 No. Voltmeter-01 No, Ammeter-01 No, LED Indicating lamp RYB-01 set, CT 400/5-01 set, Digital Energy Meter(3 Ph)-01 set. Outgoing: MCCB 63A 4P 16kA-07 Nos, 01 Set comprising of 01 No street light timer digital (astronomical) + 01 No 63A 4P Contractor + 01 No 63A Isolator (incommer) + 01 No TPN MCB (Outgoing) 01 No 10A 3 pin socket outlet with 10A switch and one brass batten holder fitted & directly fed from incoming. Busbar: 500A Capacity
1
-
-
Evaluation Notes How It Works ?
Potential Partner