Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date7 Nov 2024
Closing Soon3 Dec 2024
Tender Amount₹ 46,30,000
Costs
EMD
₹ 92,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682831_1Tender No
GE/Y-65/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
20
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
45.44
-
-
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, complete all as specified and directed.
242.35
-
-
Taking down roof trusses, coupled rafters or trussed beams of clear span exc 4m but n.exc 8m, complete all as specified and directed.
7
-
-
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section, in any postion, complete all as specified and directed.
500
-
-
Excavation in trenches not exc 1.50 metre wide and n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed.
40
-
-
Plain cement concrete M-7.5 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
5
-
-
Reinforced cement concrete M-15, nominal mix, B-1 using 20mm graded mechanically crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid separately.
5
-
-
Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate as) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
10
-
-
TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
800
-
-
TMT bars 5mm dia and over up to 10mm, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, spacers and binders, complete all as specified and directed.
300
-
-
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including curvature as per site requirement for fair finished flat surfaces of concrete, complete all as specified and directed.
50
-
-
Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
20
-
-
Removing excavated material exc 250m but not exc. 500m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed.
20
-
-
Hard core of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
7.1
-
-
Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed.
20
-
-
Walling of squared rubble masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
15
-
-
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
50
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
50
-
-
5mm thick PVC sheet fillet with 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification, complete all as specified and directed.
500
-
-
Solid/Hallow PVC Wall Lining consisting of 5mm thick wood grain (as approved by GE/Engr-In-Charge) printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing (or without PVC frame work), complete all as specified and directed by Engr-In-Charge.
150
-
-
Plain cement concrete M-15, nominal mix, type B-0, using 12.50mm graded mechanically crushed stone aggregate as in subbase floor/path surface, 25mm thick, surface finished even and rough for receiving floor finishes, complete all as specified and directed.
250
-
-
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
20
-
-
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
5
-
-
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc. set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed.
10
-
-
Vitrified ceramic tiles light shade, 10mm thick (Square/ rectangular) area of each tile exc. 0.42 Sqm but n.exc 1.00 Sqm, in floors and the like, set and jointed in neat cement slurry, woodenfinished and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
250
-
-
Vitrified ceramic tiles light shade, 10mm thick (Square/ rectangular) area of each tile exc. 0.42 Sqm but n.exc 1.00 Sqm, in vertical surfaces such as skirting and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
30
-
-
Glazed ceramic light shade/white tiles of size 350x250 /450x350/450x300 /600x300x7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
30
-
-
Disconnecting existing tanks and removing to store water tanks of capacity exc 250 ltrs but n.exc 500 ltrs, complete all as specified and directed.
2
-
-
Rotational moulded polyethylene three layered water storage tank 500 Ltrs capacity (Cylinderical vertical with closed top) hoisted and fixed in position including PVC float brass ball valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete all as specified and directed.
1
-
-
Vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat and cover for pedestal pan, fixed, complete all as specified and directed.
2
-
-
CP jet spray hygenic spray jet for 15mm bore dia fittings 1 to 1.5m long tube acrylic type, fixed in repair, complete all as specified and directed by Engr-In-Charge.
2
-
-
Supply and fixed in repair PVC valveless, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handle with brackets including 32mm dia PVC long bend flush pipe 90cm long and 15mm dia PVC connection 450mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed.
2
-
-
Wash basins, Vitreous China (Flat back type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450mm long PVC connections 15mm size with PTMT coupling nuts at both ends, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps fancy type, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed in repair, complete all as specified and directed.
4
-
-
Vitreous China bowl Urinal, flat back 465x355x265mm, white (minimum) with grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm bore PVC waste pipe and fixed in repair, complete all as specified and directed.
2
-
-
Demolition and breaking up drain pipes (Salt glazed stone ware, AC, PVC or RCC pipes) 100/110mm dia and removal of demolished materials from the site, complete all as specified and directed.
20
-
-
Demolition and breaking up drain pipes (Salt glazed stone ware, AC, PVC or RCC pipes) 75mm dia and removal of demolished materials from the site, complete all as specified and directed.
20
-
-
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of bore 110mm including fixing adjustable clamps, complete all as specified and directed.
20
-
-
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore 110mm, complete all as specified and directed.
20
-
-
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of bore 75mm including fixing adjustable clamps, complete all as specified and directed.
30
-
-
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore 75mm, complete all as specified and directed.
20
-
-
PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door, complete all as specified and directed.
10
-
-
PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door, complete all as specified and directed.
10
-
-
PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm, fixed in repair, complete all as specified and directed.
10
-
-
PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 100/110mm, fixed in repair, complete all as specified and directed.
5
-
-
PVC (SWR) bends any radius, 75mm bore jointed with solvent cement, complete all as specified and directed.
10
-
-
PVC (SWR) bends any radius, 100/110mm bore jointed with solvent cement, complete all as specified and directed.
10
-
-
600mmx450mm bevelled edge looking mirror of selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers fixed in repair, complete all as specified and directed.
4
-
-
Soap dish approximate size 160x160x90mm, chromium plated, fixed to plugs with chromium plated, brass screws, fixed in repair, complete all as specified and directed.
2
-
-
Brass Chromium Plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges, with brackets, fixed with chromium plated screws, fixed in repair, complete all as specified and directed.
2
-
-
Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed.
50
-
-
Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed.
50
-
-
Mild steel galvanized iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed.
40
-
-
All as per Serial Item No 56 above but except pipe. (Note:- Serviceable pipe retrieved from Serial Item No 54 shall be used).
10
-
-
Mild steel galvanized iron water tubing 20mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed.
40
-
-
All as per Serial Item No 58 above but except pipe. (Note:- Serviceable pipe retrieved from Serial Item No 55 shall be used).
10
-
-
Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
340
-
-
GI frame work for seamless ceilling comprising of GI permeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each lips of 10.50mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, complete all as specified and directed by Engr-In-Charge.
250
-
-
Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately), complete all as specified and directed by Engr-In-Charge.
250
-
-
Powder Coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame/chowkhat for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed by Engr-In-Charge.
100
-
-
Powder Coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, aluminium 150mm handles 2 Nos in each shutter, one aluminium door stopper, hinges type B-21 100mm, anodised aluminum snap beading screws, anodised aluminium fittings etc., complete all specified and as directed by Engr-in-charge.
10
-
-
Powder Coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprane packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) each shutter, complete all specified and as directed by Engr-in-charge.
50
-
-
12mm thick toughened glass high quality, exceeding 0.50 sqm in each pane fixed with rubber gasket and aluminium powder coated snap beading etc. and by any necessary means including all fittings and fixtures, complete all specified and as directed by Engr-in-charge.
35
-
-
Mortice lock, brass, vertical type, size 100mm, 4 lever, fixed in repair to aluminium door shutter, complete all as specified and directed.
6
-
-
Aluminium (extruded section body) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed in repair, complete all as specified and directed.
6
-
-
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins angle for shed where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc. conforming to grade Fe.410-W.Gde-E-250 quality A, steel work, complete all as specified and directed.
1000
-
-
Rolled mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc, complete all as specified and directed.
100
-
-
Mild Steel framed work as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete, conforming to Fe 290 Gde E-165, complete all as specified and directed.
100
-
-
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.290 Gde E-165, steel work, complete all as specified and directed.
1500
-
-
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
320
-
-
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
20
-
-
Harrison 25mm bore Curtain rails, aluminium anodised, chromium plated with fixing brackets, stops and roller etc. fixed in repair, complete all as specified and directed.
80
-
-
Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
300
-
-
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed.
Note : Supply only Water proofing compound shall be measured and paid for seperately.
350
-
-
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement :4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
300
-
-
Factory made solid PVC window/ventilator Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 176- of MES SSR 2020 Part-II, complete all as specified and directed.
20
-
-
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, Sheet No 1/1), complete all as specified and directed.
6
-
-
Preparation of newly plastered wall surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 Litre/ 10 sqm, complete all as specified and directed.
650
-
-
Applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel or steel based surfaces of any description, exceeding 10cm width or girth including preparation of surfaces, complete all as specified and directed.
100
-
-
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper including preparation of surface, complete all as specified and directed.
300
-
-
Preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper including preparation of surface, complete all as specified and directed.
250
-
-
Glazed ceramic, premium quality, coloured/printed tiles of size 450x350x7 to 8mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed.
224.64
-
-
Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed.
174
-
-
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed.
5
-
-
Point wiring with 1.50 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduit medium grade, ISI marked of suitable size with all fittings/ accessories such as bends, cross, elbow, tees etc. of suitable size and also including PVC insulated ISI marked unsheathed 1.50 Sqmm copper multistranded conductor, 1100 volts grade FLRS as phase, neutral and earth wire connected to common earth dolly and including concealed MS pressed steel (modular sunken box) of suitable sizes terminal boxes made from 1.60mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. and modular cover plate as top cover (ISI marked) for one light point or one fan/exhaust fan point complete all as specified and directed. Note:- (i) Wiring colour code i.e Red/Yellow/Blue for phase, Black for neutral and Green for earth shall be maintained. (ii) Point wiring is considered for modular switches and sockets. Rate of metallic sunken box and other connected accessories required for modular point wiring included in quoted rates. (iii) Rate of modular switch and sockets will be paid seperately under relevant item. (iv) Rate of cutting chases, cement plaster, white wash and making good as existing surface included in quoted rates.
126
-
-
All as per serial item No '88' above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
16
-
-
All as per serial item No '88' above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
16
-
-
All as per serial item No '88' above, but for 3 pin 15 amps socket out let on independent with 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed.
16
-
-
Supply and fix modular switch piano flush type one way 6 Amps, 1 module, 230V, Fixed, complete all as specified and directed.
158
-
-
Supply and fix modular switch piano flush type one way 16 Amps, 1 module, 230V, Fixed, complete all as specified and directed.
16
-
-
S&F Modular socket 6 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
32
-
-
S&F Modular socket 6/16 Amp 5 Pin, two module 230 Volts, complete all as specified and directed.
16
-
-
S&F Modular fan regulator step type 100 Watt two module 230 volts, complete all as specified and directed.
8
-
-
Supply and fix modular cover plate with frame, 3 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
32
-
-
Supply and fix modular cover plate with frame, 8 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
18
-
-
Supply and fix modular metal flush box 3 module Fixed in repair, complete all as specified and directed.
32
-
-
Supply and fix modular metal flush box 8 module Fixed in repair, complete all as specified and directed.
18
-
-
Ceiling rose, surface type 3 terminals 65x20mm, fixed in repair, complete all as specified and directed.
78
-
-
Single pole and neutral sheet metal enclosure with a two pin and earth plug top and socket complete with one double pole MCB 20 Amps, fixed, complete all as specified and directed.
2
-
-
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed.
4
-
-
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, complete all as specified and directed.
1
-
-
MCB SP 6 to 32 Amp, 240 Volts, 10 KA, C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
36
-
-
MCB SPN 32 Amp, 240 Volts, 10 KA, C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
4
-
-
MCB TPN 63 Amp, 415 Volts, 10 KA C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
1
-
-
Taking down carefully the existing aluminium/copper sub main wiring of any size and capacity and type by disconnecting from the either terminals complete including any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing, complete all as specified and directed by Engr-In-Charge.
220
-
-
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including concealed rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly, complete all as specified and directed.
Note:- (i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
220
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as required at site and directed by Engr-in-Charge.
30
-
-
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 1x16 watt LED, 230V, and making connection with 2 core copper conductor twisted flexible cable with suitable size from ceiling rose/ PVC connector to light, complete all as specified and directed.
20
-
-
Supply and fix LED focus light fitting integral type 12W, 5000K-6500K range, 230V, round type cool white profile LED ceiling spot lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with cabin ceiling with twin core twisted flexible copper conductor cable of suitable size, including taking down old light, complete all as specified and directed by Engr-in-Charge. Make:- Philips, Wipro
14
-
-
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 1x20 watt LED, 230V, and making connection with 2 core copper conductor twisted flexible cable with suitable size from ceiling rose/ PVC connector to light, complete all as specified and directed.
32
-
-
Supply and fixing of 35 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens enbedded PC cover having top opening seperate toughtned glass/verminproof driver compartment, SPDs with IP66 protection and impact resistance of IK07, connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of size 32mm dia lenght 1.2m along with clamps, including taking down old light, complete all as specified and as directed.
8
-
-
Supply and installing of the electric water storage heater of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge.
2
-
-
Supply and fixing of Exhaust fan of sweep 300mm, single phase, with louver shutter and connecting with electrical system, including provision of cable copper flexible, PVC three core 23/0.0076 from ceiling rose to fan and grouting of holding down bolts, fixed on wall with suitable angle iron frame, complete all as specified and directed by Engr - in - Charge.
2
-
-
Supply and fixing of wall mounted fan of sweep 450mm, single phase, with louver shutter and connecting with electrical system, including provision of cable copper flexible, PVC three core 23/0.0076 from ceiling rose to fan and grouting of holding down bolts, fixed on wall with suitable angle iron frame, complete all as specified and directed by Engr - in - Charge.
12
-
-
Supply and fixing of ceiling fan of sweep 1200mm, single phase, with louver shutter and connecting with electrical system, including provision of cable copper flexible, PVC three core 23/0.0076 from ceiling rose to fan and grouting of holding down bolts, fixed on wall with suitable angle iron, complete all as specified and directed by Engr - in - Charge.
8
-
-
Replacement of earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%