Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date16 Oct 2024
Closing Soon21 Nov 2024
Tender Amount₹ 8,00,000
Costs
EMD
₹ 16,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679767_1Tender No
AGE (I)/MNL-46/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for river sand free from organic material and silt ,including spreading ,levelling ,punning for laying /cushioning of cables complete all as specified and directed by Engr-in-charge.
22
-
-
Supply lay in trenches fly ash bricks, old size sub class “B” for cable protection,complete all as specified and directed by Engr-in-charge.
1220
-
-
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of following nominal cross sections, confirming to IS specifications :-
-
-
-
(a) 3.5 Core 50 Sq.mm
120
-
-
(b) 2.0 core 16 sq mm
200
-
-
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed :-
-
-
-
(a) 50 mm bore dia
12
-
-
M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface. Note Excavation and earth work below 150 mm thick will be measured and paid under relevent items.(pcc will be measured and paid sepretly) complete all as specified and directed by Engr-in-charge.
20
-
-
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 9.01 to 9.08. Note : Rates incl S&F of Following Serial Numbered Itmes as 9.01 to 9.08. .
1
-
-
INCOMING MCCB 800 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
-
-
-
OUTGOING MCCB 400 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
-
-
-
OUTGOING MCCB 250 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 04 No
-
-
-
Digital Volt meter 0-500 volts with selector switch – 01 No.
-
-
-
Digital Amp meter 0-400 Amps with selector switch and CT-01 No.
-
-
-
LED indicator RYB – 03 No
-
-
-
Danger Board With Conventional Sign
-
-
-
Bus - bars Aluminum 4X600 Amps with insulators
-
-
-
Note for item No- 9, 10, 11&13 : (a) Outgoing connection shall be mentioned on panel board with synthetic enamel paint all as directed by Engineer-in-Charge.(b) Semetric diagram and sizes of the panel board with bill of material, CPRI certificate shall be submitted for necessary approval of AGE(I) R & D, Manali before manufacture the panel board.
-
-
-
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 10.01 to 10.09. Note : Rates incl S&F of Following Serial Numbered Itmes as 10.01 to 10.09.
.
1
-
-
INCOMING MCCB 630 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
-
-
-
OUTGOING MCCB 400 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
-
-
-
MCCB 250 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
-
-
-
MCCB 200 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02No
-
-
-
Digital Volt meter 0-500 volts with selector switch – 01 No.
-
-
-
Digital Amp meter 0-400 Amps with selector switch and CT-01 No.
-
-
-
LED indicator RYB – 03 No
-
-
-
Danger Board With Conventional Sign
-
-
-
Bus - bars Aluminum 4X600 Amps with insulators
-
-
-
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 11.01 to 11.09. Note : Rates incl S&F of Following Serial Numbered Itmes as 11.01 to 11.09. .
1
-
-
INCOMING MCCB 250 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
-
-
-
OUTGOING MCCB 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
-
-
-
MCCB 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
-
-
-
MCB 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 04No
-
-
-
Digital Volt meter 0-500 volts with selector switch – 01 No.
-
-
-
Digital Amp meter 0-400 Amps with selector switch and CT-01 No.
-
-
-
LED indicator RYB – 03 No.
-
-
-
Danger Board With Conventional Sign
-
-
-
Bus - bars Aluminum 4X600 Amps with insulators
-
-
-
supply and fix on load change over 200 amp incl bus bar complete all as specified and directed by engineer in charge.
1
-
-
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge.The panel board should be of size to consist the following itmes as ser no 13.01 to 13.10 Note : Rates incl S&F of Following Serial Numbered Itmes as 13.01 to 13.10 .
1
-
-
INCOMING MCCB 250 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
-
-
-
OUTGOING MCCB 125 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
-
-
-
MCCB 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
-
-
-
MCB TPN 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02No
-
-
-
MCB DP 63 Amps 2 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 16 No
-
-
-
Digital Volt meter 0-500 volts with selector switch – 01 No.
-
-
-
Digital Amp meter 0-400 Amps with selector switch and CT-01 No.
-
-
-
LED indicator RYB – 03 No
-
-
-
Danger Board With Conventional Sign
-
-
-
Bus - bars Aluminum 4X600 Amps with insulators
-
-
-
M&L Electrical Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to Aluminum strip of size 25 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of siol , PCC 1 : 2 : 4 type C1 in chamber , RCC 1:2:4 type C1 40 mmthick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways,with 6 mm dia MS hook, Charcoal dust, salt , funnel for watering complete and testing the Earth resistence and writing on the chamber by paint, Complete all as specified and directed by Engr-in-charge.
12
-
-
M&L for Cement concrete 1:3:6 type C2, using 40 mm graded stone aggregates as in foundations,filling and mass concrete complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%