Military Engineer Services Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Military Engineer Services - MES Tender

Works
Solid Waste Management
Eprocure
Opening Date28 Dec 2024
Closing Soon20 Jan 2025
Tender Amount₹ 36,25,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm & n exc 20cm in width type C1,1:3:6 using 20mm graded crushed stone aggregate and setting in mortar 1:6, complete all as specified and directed.

8.2

-

-

... More
M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.

1.8

-

-

... More
M&L for PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete of post holes, etc., complete all as specified and directed.

0.9

-

-

... More
S & F Steel work in tubular trusses as in vertical posts, rafter, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specififed and dircted by Engr-in-Charge.

1066

-

-

... More
S&F for roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy brackets framing (beam, tee, angle, channel or flat sections) of Fe-410-W (Gde-E-250) quality A, including distance places, cleats etc., complete all as specified and directed.

420.5

-

-

... More
M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.

70

-

-

... More
M&L for Hardcore of gauge n exc. 63 mm Broken stone or boulders, depositing, spreading, watering, ramming and levelling in layers n exc. 15 cm thick to a true surface, complete all as specified and directed.

5.4

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

80

-

-

... More
S&F for pre-painted galvalume aluminum zinc coating GI based plain mild steel sheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed), complete all as specified and directed.

7.2

-

-

... More
M & L for Preparation of new or untreated surface of iron and applying two coats of synthetic enamel paint over and incl a coat of red oxide primer complete all as specified and directed.

3.5

-

-

... More
M&L for Reinforced cement concrete 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregates) as in foundations, footing, foundation beams, plinth beams, bases for columns and mass concrete (reinforcement to be measured separately) complete all as specified & directed.

7

-

-

... More
M & L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed.

24.4

-

-

... More
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.

24.32

-

-

... More
M & L for preparing newly plastered or previously untreated walls surfaces and applying two coats of cement base paint over and incl one coat of primer complete all as specified and directed.

24.4

-

-

... More
M&L for precast RCC 1:2:4 type B-1 using 20mm graded crushed stone agg as in cover slab and like except set in cement mortor 1:4 complete incl necessary form work complete all as specified and directed.

0.23

-

-

... More
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.

290

-

-

... More
M&L for mild steel TMT bars 6-8mm dia bar cut to length, bent to shape required including cranking, bending spirally for hoping for fencing posts and binding with mild steel wire ( annealed) not less than 0.9 mm dia complete all as specified and directed.

194

-

-

... More
Supply & fixing 500 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical triple layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted incl material and fixing of ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20mm bore and fixed in position complete, all as specified & directed by Engineer-in-charge.

2

-

-

... More
S&F for 20 mm bore of pipe, Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed by Engr In Charge.

2

-

-

... More
S&F 15mm bore Galvanised steel tubes 'medium grade' with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr In Charge.

20

-

-

... More
S&F 20mm bore Galvanised steel tubes, 'medium grade' with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr In Charge.

30

-

-

... More
S&F fancy type chromium plated, 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.

2

-

-

... More
S&F PVC (SWR) pipe 75 mm bore type B pipe single socketed, in any length, with rubber rings joints fixed to wall using clamps, etc complete all as specified and directed.

20

-

-

... More
S&F PVC (SWR) bends any radius for 75mm bore pipe, complete all as specified and directed.

2

-

-

... More
S&F 32mm bore High Density Poly-ethylene pipes of pressure rating 6 kgf/cm2, laid in trenches, complete all as specified and directed by Engr In Charge.

10

-

-

... More
S&F 20mm bore High Density Poly-ethylene pipes of pressure rating 6 kgf/cm2, laid in trenches, complete all as specified and directed by Engr In Charge.

10

-

-

... More
Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified & directed.

27.74

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed.

23.14

-

-

... More
M&L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.

15

-

-

... More
M&L for factory made, Machine made, precast cement concrete blocks (interlocking paver) pre-polished of 60mm thick confirming to IS 15658-2006 of M-35 grade, with grey cement and pigment laid over 25mm thick sand cushioning including watering and consolidation, the interlocking joints shall be filled with fine sand, complete all as specified and directed by Engr-in-charge. (Note: Sand filling shall be paid separately as material only)

15

-

-

... More
Supply only for sand filling under floors or in foundations, complete all as specified and directed by Engr-in-charge.

0.38

-

-

... More
M&L for Cement concrete (1:2:4), type B-1 using 20mm graded crushed stone aggregate for span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered on edges, throating and incl necessary form work complete all as specified and directed.

0.15

-

-

... More
S&F mild steel Framed work such as grills, gratings, etc with ends of bars shouldered or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balluster; walk ways; railings; framework of water tanks and simillar works conforming to Fe290 gde-E-165, complete all as specified and directed by Engr-in-charge.

185.82

-

-

... More
S&F for MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding etc. Fe-410-W (Gde-E-250) quality A, complete all as specified and directed.

290.6

-

-

... More
M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC Conduit with accessories having ISI mark fixed on wall surfaces / ceiling including provision PVC Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
All as per item No 38 here-in-before but for one multipin socket outlet 15 Amp, on independent board, using 2.5 Sqmm copper conductor cable, complete all as specified and directed.

4

-

-

... More
Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge.

8

-

-

... More
Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge.

4

-

-

... More
S & F of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed.

4

-

-

... More
Supply and fixing surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt along with all accessories complete all as specified and directed by Engg-in-Charge.

8

-

-

... More
Supply and fix ceiling rose 3 terminal PVC/polycarbonate, isolated body complete all as specified and directed.

8

-

-

... More
Supply, laying, commisisioning and testing cable XLPE insulated IS 7098(part-i)-1988, ISI marked screened, PVC sheathed, steel armoured electric power cable (heavy duty) with aluminum stranded conductor for working voltage upto and including 1100 volts, cross sectional area of cable 10 sqmm 4 core laid in trenches /fixed on pole/wall/passed through pipe/cutting of road with making good wherever required as per site including jointing and testing complete all as specified & directed.

160

-

-

... More
M & L for Sand cushioning for under ground cables, the trenche shall be provided with a layer of sand 8 cm deep before laying the cable and with a layer of 15 cm depth after laying and straightning of cable and then gently punned down to a depth of 10 cm above the top of the upper-most cable, complete all as specified and directed. Note: Punning shall be done by hand; mechanical punners shall not be used.

11.52

-

-

... More
M&L for laying dry old size bricks with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight in trench for protection of cable complete all as specified and directed.

1.28

-

-

... More
M&L for Earthing complete with GI steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth wire of 4 mm dia protected by GI protection pipe light grade of 40mm bore dia from mechanical injury, 20 mm medium grade for watering with funnel, including test point up to 7.5 meter from earth pit, adequate quantity of common salt, charcoal dust, chemical and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earthwork and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc. complete all as specified and directed by Engr-in-charge. Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately. 2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost.

6

-

-

... More
Supply and fixing of sheet metal enclosure double door for DBs TPN for 8 way 415 volt complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F MCB TPN 40 Amp, 10 KA in accordance with IS/IEC:60947-2 & 60898-1, 415V, 50 Hz, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F MCB SP 6-32 Amp, 10 KA in accordance with IS/IEC:60947-2 & 60898-1, 240V, 50 Hz, complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Supply and fixing LED Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

8

-

-

... More
Supply and fixing of PVC Terminal /junction pole box, 4 pole strips, mounted on DMC insulator and MCB SP 6 Amps, 10 KA, Size 310 x 210 x 120mm and fixed with MS flat iron clamps to pole complete all as specified and as directed.

8

-

-

... More
S&F bracket made of GI pipe light grade 40mm bore bend to shape in 120 degree of 1.2 m in length suitable for fixing street light luminaire and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed.

8

-

-

... More
Supply and fix of 2 runs of 1.5 Sqmm PVC FRLS insulated stranded copper cable for connection of street light including PVC conduit 20 mm external dia, fixed on pole with proper clamping/ saddling etc. complete all as specified and directed.

30

-

-

... More
Supply, laying and testing 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16), UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water, including all PP-R Plain & brass threaded polypropylene random fitting of size 25mm (outer diameter of pipe), complete all as specified and directed. Note:- Excavation and earth work shall be paid separately.

120

-

-

... More
Supply & fixing PP-R Ball Valve (brass inserted) suitable for PPR pipe line of size 25mm (outer dia), complete all as specified and directed.

4

-

-

... More
Supply & fixing PP-R Gate Valve (brass inserted) suitable for PPR pipe line of size 25mm (outer dia), complete all as specified and directed.

4

-

-

... More
Cutting of Existing water supply main any size upto 25 mm for taking branch connection including screwing of old steel tube, insertion of Tee unequal complete all as required at site, specified and directed by Engr-in-charge. Note:- Each cut shall be measured and paid separately.

2

-

-

... More
Supply, installation, Testing, and Commisioning fuel free solid waste disposal system machine of capacity 50 KG/Hour with pollution control device of following description as below:- Make: Model EWD 50PCD ECO Warriors or eqvt as recommended by Engr-in-charge and approved by GE before installation of the system. Notes:- (A) Material: Non Corrosive mild carbon steel of IS 2062 GRADE B category cylindrical chamber as specified by BIS, having minimum thickness of 6mm, manufactured by Jindal Steel or equivalent. (B) Dimensions: 1. Upper cone, dia 600mm height-580mm, thckness-6mm. 2. Cylindrical chamber dia 600mm, height-650mm, thickness-6mm. 3. Lower cone dia 600mm, height-550mm, thickness-6mm. 4. Loading door height - 400mm, width-450mm. 5. Inspection door height-150mm, width-250mm. 6. Ash door size- 300mm.

2

-

-

... More
Notes:- (C) Pollution control device: Multi level wet scrubber made using stainless steel plate of GR 304 with 4mm thickness, with activated charcoal filter and Emission testing port (D) Thermal Insulation :- 1. Inner phase- High quality imported Fire cement concrete (CALDRY's, WYTEHEAT K) (Thermally treated and cured), IS 8 End Arch fire Bricks. 2. Outer phase with 100mm thick glass wool (Density-96 kg/cum) 3. Protected with 1.0mm thick Aluminum sheet (22 gauge). Brand:- HINDALCO (E) Chimney:- Stainless steel 6", GR 304 Effective height from ground level: 8 m & thickness-3 mm (F) Additional Neck Reinforcement:- Double core technique Inner:- 6" seamless pipe schedule 40. Outer:- 8" seamless pipe schedule 40. Brand:- TATA/ Jindal/ equivalent.

-

-

-

... More
Material and Labour for Comprehensive Warranty/AMC of the Solid waste disposal system machine of capacity 50 kg/Hr complete all as mentioned below and as directed by Engr-in-charge from the date of completion of the work:- (a) Two years replacement warranty from the date of completion of the work incl necessary AMC (all machine parts, cleaning included). (b) After warranty, Comprehensive AMC for the period of four years of the complete system. All as specified and directed by Engr-in-Charge. Note for item No 60 & 61: Contractor may visit the site and submit the Drgs & approved the Make before installaltion of the system.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.