Military Engineer Services Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date6 Jan 2025
Closing Soon27 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.

136.37

-

-

... More
Excavation over areas, n.exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.

12.66

-

-

... More
Hard core of broken stone or boulders of gauge not exc 100 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed.

20

-

-

... More
Boulder filling dry, hand packed tightly, as in retaining wall complete all as specified and directed.

16.32

-

-

... More
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.

0.83

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or wit hout grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified.

5.58

-

-

... More
Pre construction anti termite treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified.

100

-

-

... More
Pre construction anti termite treatment by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified.

100

-

-

... More
Pre construction anti termite treatment by treating the soil along with externalperimeter of building at the rate of 2.25 litreof emulsion per metre of the perimeter wall, complete all as specified.

39.5

-

-

... More
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.

6.5

-

-

... More
PCC 1:2:4 (nominal mix) type B-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.

4.22

-

-

... More
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork where required complete all as specified and directed.

0.67

-

-

... More
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.

5

-

-

... More
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.

15

-

-

... More
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in chajjas and like complete all as specified and directed.

6

-

-

... More
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in Columns, pillars, piers, posts and struts complete all as specified and directed.

0.7

-

-

... More
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.

13

-

-

... More
Concrete bed to drain pipe of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) complete all as specified and directed. Note :- Thickness of bed and width of bed shall be provided all as per preamble a (i) & a (ii) on Srl page no 391 of SSR Part-II Rates (2020).

28.5

-

-

... More
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 150mm, complete all as specified & directed.

30

-

-

... More
Precast reinforced cement concrete as in landing, cover slabs (for manhole etc) and similar articles with precast cement concrete Type B-1, 1:2:4 (20mm graded crushed stone aggregate) and setting in cement mortar 1:4 complete all as directed.

0.08

-

-

... More
Precast cement concrete M-10, nominal mix, type C-1, using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, coloums, posts, boundry pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling) etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:6 complete with joints to match, complete all as specified.

2.07

-

-

... More
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfor rough finished surfaces of concrete flat, complete all as specified & directed.

80

-

-

... More
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beamsfor rough finished surfaces of concrete, complete all as specified & directed.

120

-

-

... More
Use & waste of form work to Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete for Square, rectangular or polygonal surface, complete all as specified & directed.

85

-

-

... More
Use & waste of form work to Formwork to chullah hoods, chajjas, troughs and similar items including edges, for rough finished surfaces of concrete flat complete all as specified & directed.

6

-

-

... More
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:4 (01 cement : 04 coarse sand) all as specified & directed.

0.75

-

-

... More
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.

32.2

-

-

... More
Walling of random rubble stone masonry uncoarsed, well bonded bedded and soilidly hearted built in CM 1:6, complete all as specified and directed.

34.76

-

-

... More
Powder coated, Anodised aluminium frame powder coated for doors, windows, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed.

110

-

-

... More
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified.

15

-

-

... More
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Pane of 4 mm thick sheet glass to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ), and joined together with solvent cement, suppling & fixing in the frame at site, complete as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed.

4.68

-

-

... More
Powder coated, Anodised aluminium door shutters powder coated, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, anodised aluminum snap beading screws etc. complete all as specified.

2

-

-

... More
Powder coated, Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.

16

-

-

... More
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.

6

-

-

... More
Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed.

9

-

-

... More
Aluminium (die cast) body ,door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg ,complete all as specified and directed.

1

-

-

... More
Brass mortice lock, 4 levers, vertical type, 100 mm size for doors all as specified.

1

-

-

... More
Mild steel butt hinges of size 100 mm medium weight cold rolled complete all as specified and directed.

9

-

-

... More
Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples complete all as specified and directed.

10

-

-

... More
Sheet glass, 4.8mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.

10

-

-

... More
Hi Steel Clip in false Ceiling System with Steel Tile 595 mm X 595 mm manufactured out of 0.50 mm thick polyester coil-coated Galvanized Steel having 180 gms zinc coating Coil-coated Steel tile shall have a 20-micron polyester-coated finish on front side and a backcoat of 5-micron alkyd primer. Two sides of each tile shall have raised, piped and stopped to ensure positive engagemant into the spring clip in profile allowing for demlition of individual tiles . The rgid susoension system consists two rows of 0.5mm galvanised steel clip in profile od size 38mm installed at 600mm centre to centre spacing to support the tiles.Wall suspesion Wall Suspension angles /Hangersof size 24 mm X 24 mm X 0.4 mm thick are fixed to the roof by expansion fasteners. Wall suspension angles to be made out coil coated Steel matching the color of the tile. They will be jointed to the clip-in-profilr system by hold on clamps. The Tiles/Planks shall be held in place by pressure clips as per manufacturer's instructions for spacing. in the flexible system the hanger and butterfly clip shall replace the suspension angle, including necessary scaffolding as per manufactruer,s specifications/ instructions, complete all as specified. ‍

70

-

-

... More
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.

110

-

-

... More
Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified

7

-

-

... More
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.

1442

-

-

... More
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.

2732.12

-

-

... More
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.

1190

-

-

... More
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard sectionand fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge

15

-

-

... More
100mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. .

90

-

-

... More
75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. .

477

-

-

... More
Plain cement concrete , 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75m thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).

50

-

-

... More
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic Non skid tiles 7-8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.

20

-

-

... More
Glazed ceramic coloured tiles of size 450 mm x 350 mm x 7 mm/350 mm x 250 mm x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.

30

-

-

... More
Vitrified ceramic tiles (Dark shade) 10mm thick (square/rectangular) polished, area of each tile exceeding 0.36 sqm but not exc 0.42 Sqm as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.

70

-

-

... More
20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick screed base in cement mortar 1:6 over and complete all as specified and directed.

5

-

-

... More
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator complete all as specified and directed.

477

-

-

... More
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.

167

-

-

... More
Rendering cement plaster 10mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (5mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.

155.4

-

-

... More
Rendering cement plaster 15mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.

4.47

-

-

... More
5 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling , surface finished even & smooth without using extra cement complete all as specified and directed .

30

-

-

... More
Supply only intergal water proofing compound, complete all as specified.

2.28

-

-

... More
Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 40mm, complete all as specified & directed.

24

-

-

... More
Flush pointing to random , uncoursed or brought upto courses in cement mortar 1:4, complete all as specified.

2.4

-

-

... More
Preparation of new plastered or unplastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.

167

-

-

... More
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.

150

-

-

... More
Three coats of white wash on newly plastered or un plastered, previously undecorated ceiling surfaces including preparation of surfaces complete, all as specified.

30

-

-

... More
Three coats of white wash on newly plastered or un plastered, previously undecorated wall surfaces including preparation of surfaces complete, all as specified.

5.4

-

-

... More
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.

20

-

-

... More
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.

5

-

-

... More
G I tubing medium grade of 25 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.

40

-

-

... More
G I tubing medium grade of 40 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.

70

-

-

... More
Anodised Aluminium alloy, chromium plated , curtain rod, 20 mm bore, with all fittings i.e. wall bracket, bracket screws, stope and rollers, all as specified.

15

-

-

... More
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws complete all as specified

2

-

-

... More
PVC flexible waste pipe, 40mm dia, suitable for WHB including threaded PVC Socket suitable for shank of waste, coupling, complete all as specified.

1

-

-

... More
15mm bore, chromium plated, centre hole mixer half turn complete, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, complete all as specified.

2

-

-

... More
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.

2

-

-

... More
Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified

1

-

-

... More
Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (including fixing bolts, flush pipe, PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 7.0 litres), with grating and union for discharge pipe, flush pipe and waste pipe, Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and as directed.

1

-

-

... More
Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15mm bore iron pipe or for unions, complete, all as specified.

6

-

-

... More
Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore complete all as specified and directed.

6

-

-

... More
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed bore dia of pipe 25mm complete all as specified and directed.

1

-

-

... More
PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed.

3

-

-

... More
Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of 'Cera' or equivalent in makes mentioned in Appx 'C'

1

-

-

... More
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends , all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx 'C'.

1

-

-

... More
600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers, complete all as specified.

2

-

-

... More
110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls, complete all as specified and directed.

5

-

-

... More
75mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls, complete all as specified and directed.

13

-

-

... More
110 mm dia PVC(SWR) bend, any radius complete all as specified and directed.

2

-

-

... More
75 mm dia PVC(SWR) bend, any radius complete all as specified and directed.

1

-

-

... More
75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.

3

-

-

... More
50mm bore, Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm as in weep holes, complete all as specified.

14.4

-

-

... More
Cutting th existing CI/GI pipe (40 to 150mm bore) or screwing existing CI/GI pipe for addn/altn as required at site including GI fittings , complete all as specified. Note : Earth work shall be measured and paid seperately.

1

-

-

... More
Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified.

1

-

-

... More
LLDPE septic tank designed to carry sewage and sludge water, Comprising earth work, excavation in hard rock, returning filling, disposal of surplus spoils to a distance not exc 50 meter from starting points, PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) in foundation, 200mm thick, Vent shaft, connections etc. for 10 users (1600 litre capacity) including all fittings, fixtures, testing on completion Approximate Dimensions. Dia 1440 mm, height 1550 mm and total HRT 48 hr complete all as specified and directed. MAKE:- Sintex or equivalent make as approved.

1

-

-

... More
Soakage well excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40m dia and 3m effective depth, complete all as speciifed.

1

-

-

... More
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC conduit not less than 20mm dia, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.

15

-

-

... More
All as per serial item No '98' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.

1

-

-

... More
All as per serial item No '98' above, but for one 3 pin 5 Amps socket outlet on the independent board all as specified and directed.

6

-

-

... More
All as per serial item No. '98' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.

2

-

-

... More
Switch piano flush type, single pole, one way, 5 Amps, all as specified.

22

-

-

... More
Switch piano flush type, single pole, one way, 15 Amps, all as specified.

2

-

-

... More
Socket outlet two & three pin 5 Amp flush type, all as specified.

7

-

-

... More
Socket outlet two and three pin, 5 Pin, 5/16 Amp flush type controlled by one switch, all as specified.

2

-

-

... More
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.

15

-

-

... More
Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. 1x20W, 6500K ,230V, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havells cat part No. LHEXAWP7IN1W020 or equivalent in Appx

9

-

-

... More
Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack , 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havell's Cat Part No. LHEXACP7IN1W010 of "Havells" or equivalent in makes mentioned in Appendix

2

-

-

... More
35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket made up og 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx

3

-

-

... More
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar, all as specified.

1

-

-

... More
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).

10

-

-

... More
MCB SPN 40 Amp, 240 Volts, 10 KA all as specified.

1

-

-

... More
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.

5

-

-

... More
Supply and installing of Electric Water storage heater of ABS body type 25 Litre Capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated Mild steel tank with, glass line coating inside he tank alongwith glass line incoloy heating element with anti corrosive magnesium anode, NRV, theremostate, indicators and temperature adjustable knob including steel braided flxible connection for pipe of size 15mm dia bore GI hexagonal adopeters./ Nuts on both sides of inlet (Cold water supply) & outlet (hot water supply) and including provision of wall mouting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as dierected by Engr-in-Charge.

2

-

-

... More
Exhaust fan, 300mm sweep, steel body AC single Phase. 230V complete with with, blades, and frame and louvers including provision of cable copper flexible PVC three core 23/0.0076 from ceiling rose to fan, complete all as specified. Note : Quoted rate shall include for making hole in wall for grouting, fixing the fan on outer side of wall with suitable size anchor bolt and making good disturbed surfaces without ant extra cost.

2

-

-

... More
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.

16.71

-

-

... More
Un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and directed.

1850

-

-

... More
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.

175

-

-

... More
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.

50

-

-

... More
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.

150

-

-

... More
Outdoor type factory made bus bar chamber of size 0.75x 0.45x 0.40 meter depth made out of CRCA sheet 3.15 mm thick with 4 Nos aluminium busbars of capacity 200 Amps with colour code supported on incoming and outgouing under ground cables with LED R, Y, B indicator lamp, panel having angle iron frame made of 40 x 40 x 6 mm angle iron and 50 cms long legs embeded upto 20 cms in PCC & 30 cms clear above ground complete includng painting with two coat of powder coated paint over a coat of red oxide primer on exterior and interior faces, errection of Bus Bar chamber duly grourted with PCC including earth work complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.

1

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32X6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.

4

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25x 4mm dia (as earth lead), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.

4

-

-

... More
Air termination, single pointed aluminium rod 12mm dia and 300mm long, with necessary fixing arrangement on blocks on roof,complete all as specified and directed.

3

-

-

... More
Aluminium strip 25 x 3.15mm with saddles & fixing fixing screws etc.on roof with rubber and bitumen washer and fixed to insulator on wall for down conductors complete all as specified and directed.

30

-

-

... More
25x4mm galvanised iron strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, complete all as specified and directed.

10

-

-

... More
Vitreous china porcelain insulator with busbar support white type, complete all as specified.

20

-

-

... More
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal head screw, complete all as specified and directed.

2

-

-

... More
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-

1

-

-

... More
Incoming:- (a) MCCB having current rating 63 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No)

-

-

-

... More
Outgoing:- (a) MCCB having current rating 63 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Time switch Digital time switch astronomical type for switching on/off lights and other eletric devices according to the rising/ setting of the sub with comination function for creatomg switching programs in which the devices are switched according to atronmical time and / or fized preset time daily atromical calculation of the sunrise/ sunset times based on the entered location of location cordinate having MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage-240 V AC, 50 Hz working temp, upto 55 degree celcius complete with all accessories-01 No. (c) Power contactor 3 pole, type ML-3, with 2 No + 2 NC Aux contacts with standard coil voltage 415 volts, Rating 70 Amp-01 No as per Cat No SS90910 of M/s L&T or its equivalent in , Siemens, Schneider including testing connecting commissioning complete all as specified and directed.

-

-

-

... More
Outgoing (Contdd.):- (d) Fuse holders suitable for bolted fuse-links Both side cable (Front) 32 Amps-03 Nos (e) Single phasing preventing, under voltage, over voltage and neurtral loss protection relay 415 VAC , 3 Phase 4 wire, 5 C/O and with technical parameters as per M/s L&T Cat Part No -MAC04 D0100-01 No (f) Double pole toggle switch ON-OFF-ON, 250 V, 20 A -01 No (g) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (h) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 5 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (j) LED phase indicator lamp ( Qty- 01 set of three) (k) 100 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding. (e) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (e) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (f) LED phase indicator lamp ( Qty- 01 set of three) (f) 300 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.

-

-

-

... More
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing

-

-

-

... More
Supply & installation of 16 Metre high mast shaft in two section suitbale for 55 m/sec wind speed along with head frame, luminiaries carriage suitable for 08 luminiaries in symmetrical arrangement and other accesories manufactured in factory with raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial, (Wiring material from JB to individual luminiare & MCB in base compartment are not included and are a part of installation), with supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5sq. mm terminals. 16M High mast of make BAJAJ, Crompton, Philips, Havells or equivalent make as approved by AGE (I).

1

-

-

... More
HIGH MAST SYSTEM MAKE : Bajaj Electricals Ltd/, Crompton, Philips, Havells or equivalent make as approved by GE. Height of mast : 16 Meter No. of Section : Two Material Construction : S355 Grade as per BS-EN10 025 Base dia and top diameter (A/F) :- Top : 150mm Botton : 460 mm Cross section of Mast : 20 side polygon Standard for Galvanisation : A per BS EN ISO 1461 Size of Opening and door at base : 1200 x 250 mm Diameter of base plate : 670 mm Thickness of base plate : 25 mm Lighting protection finial : GI single spike of length 1200mm Max. wind speed : 44m/s as per IS 875 (Part III) Number of foundation bolts : 12 Nos PCD of foundation bolts : 590 mm Type / diameter / length of foundation bolts : TS 600/30mm dia/ 850 mm long

-

-

-

... More
FOUNDATION DETAILS 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick ( 1: 4: 8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing 5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 150mm C/C as Stirrups 9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanished nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, external finishes and other unforeseen items all as directed by Engr - in- Charge

-

-

-

... More
LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 535 mm (ID) Construction : 06 Arm, Welded, 2 Sections Load carrying capacity : 08 Luminaire

-

-

-

... More
TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One

-

-

-

... More
WINCH / POWDER TOOL Type /SWL of winch : Double drum, SWL 750 Kg - SGDD Method of Operation : Integral Motor Motor Capacity : 1.0 HP ( Including suitable starter) No of Speeds : 6 Pole, Single speed Torque Limitor ; With Mechanical Tripping Facility

-

-

-

... More
STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : 6 mm Breaking load Capacity : 2350 Kg x 2

-

-

-

... More
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.

18

-

-

... More
Bajaj amaze 200w LED flood light , Matt black polyester powder coated with secondary lens optics with LED make lumiled having luminaire efficacy of 130 lm/W. Total of 26,000 Lums +/- 10%. Provided with built in surge protection 5kv and external surge protection of 10kv, having Ingress protection Ip66. Model:- Bajaj Cat Part No. BJFL 200W LED I / or equivalent make as approved by GE.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.