Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date2 Dec 2024
Closing Date21 Dec 2024
Tender Amount₹ 49,01,000
Costs
EMD
₹ 98,020Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686677_1Tender No
GE/863/EWS-T-47 OF 2024-25 SPECIAL REPAIR OF SEPTIC TANK, SEWAGE KARCHAM AND POARI UNDER GE 863 EWSTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removal of blockage from Indian WC / EWC (at ground floor) by removing all sludge / waste etc. including cleaning of connected pipe up to first manhole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc. (in covered tanks) outside MoD land complete all as specified and directed.
Note :- (i) No extra cost for necessary excavation, earthwork and refilling with excavated soil over the sludge and bleaching powder shall be paid and quoted rate shall be deemed to be included for this provision.
(ii) The cleaning of WC / EWC shall be carried out mechanically using apropriate technological appliances.
19
-
-
Cleaning & Desludging of septic tanks of capacity 30 to 50 users by pumping out sewage water, sludge & disposing all waste including liquid in covered tanks / containers outside MoD land and finally cleaning & washing with fresh water complete all as specified and directed by Engr-in-charge.
Note :- (i) No extra cost for necessary excavation, earthwork and refilling with excavated soil over the sludge and bleaching powder shall be paid and quoted rate shall be deemed to be included for this provision.
(ii) The cleaning of Septic tank shall be carried out mechanically using apropriate technological appliances.
10
-
-
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, cesspits, manholes etc. not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
158.96
-
-
Demolition and breaking up drain pipes, 150 mm internal dia of pipe (PVC / Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
250
-
-
Demolition and breaking up drain pipes, 100/110 mm internal dia of pipe (PVC / Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar or fixed to walls complete all as specified and directed.
80
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.
131.03
-
-
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
32.4
-
-
M&L for PCC 1:4:8 type D-2, (Using 20 mm graded stone aggregate) as in bed to drain pipes for 150mm bore of pipe incl packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
250
-
-
M&L for PCC 1:4:8 type D-2, (Using 20 mm graded stone aggregate) as in bed to drain pipes for 100/110 mm bore of pipe incl packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
100
-
-
S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and as directed.
80
-
-
S&F PVC (SWR) pipes 150/160mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
250
-
-
Demolition of reinforced cement concrete as in ground floor and pavings, cover slab for MH/Spetic tank n exc 15 cm thick (below or above ground level (reinforcement cut as required to facilitate demolition), complete all as specified and directed.
Note:- Demolished material to be removed outside of MoD land or as directed.
13.25
-
-
M & L precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab of Manholes / Septic tank set in CM 1:4, incl necessary formwork, etc. complete all as specified and directed.
13.25
-
-
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
1200
-
-
Demolition of brickwork or stone/boulder or pre-cast block masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
83.38
-
-
M&L for Pre-cast cement concrete 1:3:6 type C-1, (20mm graded crushed stone aggregate) block masonary with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
83.38
-
-
M & L for rendering 15mm thick on fair faces of block work, stone or concrete work in cement mortar 1:4 incl finishing even and smooth without using extra cement, complete all as specified and directed.
1260
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm avg. thickness (below or above ground level) complete all as specified and directed.
27.16
-
-
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in fdns, filling and mass concrete complete all as specified and directed.
17.41
-
-
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone agg) as in surface channels, drain and manhole complete all as specified and directed.
1.88
-
-
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends, etc., complete all as specified and directed.
28
-
-
S&F in repair PVC (SWR) pipes of bore 75 mm single socketed, in any length with rubber ring joints, fixed on walls or in floors complete all as specified and as directed.
15
-
-
S&F PVC (SWR) plain bend for pipe of bore 110 mm, of any radius with rubber ring joints, complete all as specified and as directed.
10
-
-
S&F PVC (SWR) plain bend for pipe of bore 75 mm, of any radius with rubber ring joints, complete all as specified and as directed.
5
-
-
S&F in repairs for Wash basins, Vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand, supply pipe of 15 mm size, CP brass pillar tap for 15mm bore of pipe, waste coupling (min wt-45gms) of PTMT for 32 mm bore dia of waste pipe, 32 mm bore of waste/discharge pipe, etc. complete all as specified and directed by Engr-in-charge.
10
-
-
S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device for pedestal pan (including fixing of flushing cistern and flush pipe) complete all as specified and as directed.
5
-
-
Supply and fix in repairs white vitreous china water closet squatting pan ‘ORISSA’ pattern of size 580 mm x 450 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connections and provision of lime concrete bedding, incl connection to trap, drain (or outgoing pipe), fixing of flushing pipe, antisyphonage pipe, and flushing cistern etc. complete all as specified and as directed.
15
-
-
Supply only PVC valveless, syphonic action type, flushing cistern, 10ltr capacity low level, white, with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern, complete all as specified and directed.
20
-
-
S&F in repairs vitreous china urinal, half stall type, white incl providing and fixing flange for support, grating, union for discharge pipe, chromium plated water spreader, connection pipe and discharge down pipe complete all as specified and directed.
5
-
-
Taking down cement plaster in cement mortar on brick or stone walls / ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed.
40
-
-
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
40
-
-
Taking up or down 15mm bore steel tubing and connections complete all as specified and as directed.
19
-
-
Taking up or down 20m bore steel tubing and connections complete all as specified and as directed.
20
-
-
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm complete all as specified and as directed.
19
-
-
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20 mm complete all as specified and as directed.
20
-
-
S&F in repairs mirror glass of size 0.60X0.450m bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with cromium plated brass screw and cup washer etc complete all as specified and as directed.
10
-
-
S&F in repair brass CP Stop cock/ Angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for bore dia of pipe 15mm, fancy type, chromium plated, complete all as specified and as directed.
20
-
-
S&Fin repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered HOT or COLD with long screwed shank and fly nuts screwed for iron pipe and fixed for bore dia of pipe 15mm complete all as specified and directed.
15
-
-
S&F in repairs bib taps, cast copper alloy, choromium plated, with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule and fixed fpr bore dia of 15mm pipe complete all as specified and as directed.
25
-
-
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
25
-
-
S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
20
-
-
S&F in repair towel rail 600mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastic cleats of weight minimum 190grm complete all as specified and as directed.
20
-
-
S&F in repair brass CP mixer, 15mm bore ,for mixing hot & cold water screw down for iron pipe , complete all as specified and as directed.
10
-
-
M & L for complete removal of existing treatment of old plastered surfaces, preparation of wall and applying three coats of white wash complete all as specified and directed.
78
-
-
M & L for complete removal of existing treatment of old plastered surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and directed.
90
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removing rubbish off the premises, complete all as specified and directed.
350
-
-
M &L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) as in sub base in floors complete all as specified and directed by Engr-in-charge.
164
-
-
M&L for screed bed or bedding layer of 15 mm thick CM 1:6 for laying floor finished to receive floor tiles/granite, complete all as specified and directed.
164
-
-
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles. Tiles shall be conferming to IS - 15622, 2006, Gp-B II with average water absorption between 3% to 6% length, width and straitness of sides +10% (Max daviation). Thickness +5% (Max daviation). Centre & Edge curvature warpage +.5% (Max daviation). Breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defect. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE.
164
-
-
M/L rendering 10mm thick in CM 1:4 on stone masonry surfaces or surfaces other than fair face of brick work as a backing coat rough finished to receive glazed tiles/granite, complete all as specified and directed.
350
-
-
M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles. Tiles shall be conferming to IS - 15622, 2006, Gp-B II with average water absorption between 3% to 6% length, width and straitness of sides +10% (Max daviation). Thickness +5% (Max daviation). Centre & Edge curvature warpage +.5% (Max daviation). Breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defect. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE.
350
-
-
Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent, holder, light fitting & regulator etc. (Schedule of credit for each item to be given separately) including making good to the disturbed surfaces of wall, roof and floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
161
-
-
Taking down unserviceable submain wiring and service cable alongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface complete all as specified and directed at site.
310
-
-
Taking down unserviceable main switches, DBs with alongwith MCB SP/Isolators by unscrewing form board (Sch of Credit for MCBs to be taken separately) complete all as specified and directed by Engineer-in-Charge
8
-
-
M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC Casing and caping with accessories having ISI mark fixed on wall surfaces / ceiling including provision PVC Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
120
-
-
All as per Srl item No 58 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge.
9
-
-
All as per Srl item No 58 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge.
8
-
-
All as per Srl item No 58 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.
24
-
-
Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
24
-
-
Supply and fixing of socket outlet 3 pin 15 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge.
24
-
-
Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge.
17
-
-
Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
137
-
-
M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge.
75
-
-
Supply and fixing surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge.
32
-
-
Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings.
37
-
-
Supply and fixing LED lamp 9W backup lamp, of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9W lamp in normal mode and 4W lamp in backup mode with all accessories all as specified and directed by Engg-in-Charge.
37
-
-
Supply & Fixing LED light fitting 1x9W / 10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
16
-
-
Supply and fixing sheet metal enclosure double door for DBs single pole and neutral for 4 way 240 volt complete all as specified and directed by Engineer-in-Charge
3
-
-
Supply and fixing sheet metal enclosure double door for DBs single pole and neutral for 8 way 240 volt complete all as specified and directed by Engineer-in-Charge
2
-
-
Supply and fixing sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge
3
-
-
S&F MCB SPN 32 Amp, 10 KA, 240V in the MCB DB complete with connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
3
-
-
S&F MCB SPN 40 Amp, 10 KA, 240V in the MCB DB complete with connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F MCB SPN 63 Amp, 10 KA, 240V in the MCB DB complete with connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
3
-
-
S&F MCB SP 6 Amp to 32 Amp, 10 KA, 240V in the MCB DB complete with connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
30
-
-
M&L in replacement for Earthing complete with GI steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth wire of 4 mm dia protected by GI protection pipe light grade of 40mm bore dia from mechanical injury, 20 mm medium grade for watering with funnel, including test point up to 7.5 meter from earth pit, adequate quantity of common salt, charcoal dust, chemical and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earthwork and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc. complete all as specified and directed by Engr-in-charge.
Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately.
2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost.
8
-
-
Supply, laying, fixing and testing 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connection as in trenches, one twin core cable flat or circular of size 6 Sqmm nominal cross-section, complete all as specified and directed.
100
-
-
Supply, laying, fixing and testing 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connection as in trenches, one twin core cable flat or circular of size 10 Sqmm nominal cross-section, complete all as specified and directed.
60
-
-
Supply, laying, fixing and testing 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connection as in trenches, one twin core cable flat or circular of size 16 Sqmm nominal cross-section, complete all as specified and directed.
150
-
-
M & L for Sand cushioning for under ground cables, the trenche shall be provided with a layer of sand 8 cm deep before laying the cable and with a layer of 15 cm depth after laying and straightning of cable and then gently punned down to a depth of 10 cm above the top of the upper-most cable, complete all as specified and directed.
Note: Punning shall be done by hand; mechanical punners shall not be used.
13.39
-
-
Supply and laying of well burnt 'B' class bricks as mechanical protection to under ground cables laying with length of the bricks along the width of the trenche, complete all as specified and directed by Engineer-in-Charge
1.49
-
-
Supply and fix PVC exhaust fan, AC single Phase 230V of size 300mm sweep 1400 rpm with blades, frame and louvers, complete all as specified and directed by Engineer-in-Charge.
10
-
-
Schedule of Credit
-
-
-94977.51
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%