Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date1 Mar 2024
Closing Date29 Mar 2024
Tender Amount₹ 1,00,00,000
Costs
EMD
₹ 1,75,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_636955_2Bid Award Id
ViewTender No
CWE/AF CHD/CHD/T-25/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for point wiring complete with 1.5 sqmm single core pvc insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including conduit accessories ISI marked concealed in wall/fixed to roof ceiling etc with and including provision of 1.5 sqmm PVC insulated multistranded unsheated copper conductor FRLSH cable ISI marked as earth continuity conductor, fabrciated sunken terminal box made out of 1.22 mm thick sheet steel duly painted concealed in walls, with 3 mm thick bakelite sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan, regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. Note :- (i) The chases in the wall shall be cut with electric cutter.
25
-
-
All as per item No. 04 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.
5
-
-
All as per item No. 04 here-in-before but point wiring for one 5Amps socket outlet point on same board controlled by one single pole, one way switch complete all as specified and directed.
5
-
-
All as per item No. 04 here-in-before but point wiring using 4 sqmm as main wire & 4 Sqmm as earth continuity conductor/earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.
10
-
-
S&F Switch piano, flush type, single pole, one way, 5 Amp, 230 volts complete all as specified and directed.
30
-
-
S&F Switch piano, flush type, single pole, one way, 15 Amp 230 volts complete all as specified and directed.
5
-
-
S&F Socket outlet multipurpose 3 pin 5 Amp, flush type, complete all as specified and directed.
5
-
-
S&F Socket outlet multipurpose 3 pin 15 Amp flush type, complete all as specified and directed.
5
-
-
S&F Ceiling rose, two to three terminals, PVC/ isolated body, complete all as specified and directed.
20
-
-
S&F Metallic body Exhaust Fan 250mm sweep fixed and connected with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified and directed.
5
-
-
S&F LED Decorative box type batten fitting 1x20 W, prewired suitable for retrofit LED tubes, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm from ceiling rose to connector block, complete all as specified and as directed.
10
-
-
S&F Sheet metal enclosure (DB) single phase & neutral, double door 8 ways, 240 volt with 200 Amps rated bus bar & IP 54 protection complete all as specified and as directed.
5
-
-
S&F MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'C' curve, complete all as specified and as directed.
20
-
-
S&F MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA, 'C' curve, complete all as specified and as directed.
5
-
-
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 2.5 Sqmm (Nominal area) multi stranded copper conductor FRLSH cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 2.5 Sqmm FRLSH connected to common earth dolly and drawing into and incl rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete. NOTE : Two runs of submain wiring cable alongwith one run of earth wire and one run of conduit shall be measured as one length.
10
-
-
S&F LED Bulk Head fittings 1x10 W, with IP 65/66 protection and heat resistance connecting with three core PVC copper flexible cable of size 1. Sq mm complete all as specified and as directed.
5
-
-
M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductror 1100 volts grade cross-sectional area 25 sqmm 3 core complete all as specified and directed.
100
-
-
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire of size 4 mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 15mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1, RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.
Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance shall be less than 3Ohm. In case test results are not found below 3Ohm, complete earthing will be re-done without any extra cost to Govt.
5
-
-
SCH A PART-III EARTH WORK AND EXCAVATION WORKS
-
-
-
Excavating over areas, n.exc 1.5m deep and getting out in soft/disintegrated rocks complete all as specified and as directed.
414.53
-
-
All as per Item No 23 here-in-before but depth exceeding 1.5 m and n exc 3 m complete all as specified and as directed.
324.83
-
-
All as per Item No 23 here-in-before but depth exceeding 3 m and n exc 4.5 m complete all as specified and as directed.
108.27
-
-
Excavating over areas, n.exc 1.5m deep and getting out in hard dense soil complete all as specified and as directed.
89.7
-
-
All as per Item No 26 here-in-before but depth exceeding 1.5 m and n exc 3 m complete all as specified and as directed.
89.7
-
-
Excavating in trenches n exc 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in hard/dense soil complete all as specified and as directed.
160.83
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
257.58
-
-
Removing excavated material outside of MOD land to the place desingated/earmarked by the civil authority/adminisrtration complete all as specified and as directed.
657.54
-
-
SCH A PART-IV STATIC WATER TANK WORKS
-
-
-
M&L for Cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
27.38
-
-
M&L for RCC (Design Mix) M-30 using (20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc basement slabs, under reamed plies and mass concrete complete all as specified and as directed.
71.24
-
-
M&L RCC (Design Mix) M-30 (20mm graded stone aggregates) in Walls, retaining walls, basement walls ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed.
101.85
-
-
M&L for Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work ; vertical or batter rough finished surface of concrete complete all as specified and as directed.
44.8
-
-
M&L for Use and waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc vertical or to batter rough finished surface of concrete complete all as specified and as directed.
582
-
-
M&L for Mild steel TMT bars, 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
16465.65
-
-
All as per Item No 37 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
65.15
-
-
M&L for Brickwork with subclass 'B'' old size bricks, straight or cuved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
37.63
-
-
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 finished even and fair without using extra cement complete all as specified and as directed.
378.4
-
-
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
2.88
-
-
M& L for cement concrete (1:2:4) type B1, using 20mm stone graded aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
0.84
-
-
M&L for Mild Steel Framed work such as grills, gratings etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars; barred iron doors, ladders; framed balusters; walkways, railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
1522.08
-
-
M&L for Welded steel wire fabric fixed to wood or steel members weight n exc 4 kg per sqm complete all as specified and as directed.
1215.36
-
-
M&L for walling of random rubble stone masonry, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and as directed.
101.4
-
-
Extra over stone walling, trap or granite stone for hammer dressing to face stones and dressing to face beds and joints, as specified of random rubble walling, uncoursed or brought upto courses, hammer dressing with maximum depression n.exc 40mm on face from straight edge held against the dressed surface complete all as specified and as directed.
96
-
-
M&L for Pre-cast cement concrete (1:2:4)Type-B-1 using 20mm graded stone aggregate as in Band stone and setting in cement mortar 1:6 with joints complete all as specified and as directed.
4.06
-
-
M&L for Hand packing (any thickness) at back of walls over arches etc and raising (or lowering) to the required level with broken stone or boulder complete all as specified and as directed.
35.1
-
-
M&L for Raised pointing to random or polygonal rubble, uncoursed or brought upto course in Cement mortar 1:4 complete all as specified and as directed.
9.6
-
-
S&F110mm bore PVC(SWR) pipes, pressure rating 6kgf/cm2 in walls complete all as specified and as directed.
171.6
-
-
M&L for Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
172.8
-
-
M&L for extra forming fair finished drains or channels exec 30cm inner girth in cement concrete using extra cement incl forms, moulds, mitered/stopped ends etc complete all as specified and as directed.
200
-
-
M&L for cement concrete 1:2:4 type -B2 (using 40mm graded stone aggregates) as in Surface channel & drain complete all as specified and as directed.
6
-
-
M&L for cement concrete 1:2:4 type -B1 (using 20mm graded stone aggregates) as in coping/benching including weathering throating and necesarry fromwork complete all as specified and as directed.
4.81
-
-
SCH A PART-V EXTERNAL ELECTRIFICATION WORKS
-
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Voltas grade with standred aluminum conductor of size 50 sqmm 3.5 core complete all as specified and as directed .
100
-
-
Supply, installation and testing complete Monoblock pump 15 HP set discharge flow capacity 916 LPM upto 60 mtr head, 03 phase electric motor, Voltage range 415 Volts, suitable for sunction 80mm dia and discharge 65mm dia mounted on MS steel channel of size 100mm incl making connections to pannel boards PCC foundation etc, with suitable air release mechanism complete all as specifed and as directed.
6
-
-
Supply and installation, testing LT cubical Electric panel board with following switch gear. 63 Apms -02 MCCB (01X for incoming & 01X for out goning ) Volt meater 01 0-500 Amps Meter 01 Nos phase indicator lamp 01 Set spare star delta stater .01 no with capacity of 200 amp Aluminium BUS bar etc, in door tyoe including camplete wiring of panel and counted to main lain.and CPRI approved , with 2 mm thickness,PCC foundation etc complete all as specifed and as directed.
5
-
-
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mm x 6 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1, RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.
Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance shall be less than 3Ohm. In case test results are not found below 3Ohm, complete earthing will be re-done without any extra cost to Govt.
20
-
-
M&L for sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed
Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
8.1
-
-
M&L for locally available, sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protection prependicular to the direction of cable adjacent to each other complete all as specified and as directed.
0.9
-
-
SCH A PART-VI EXTERNAL WATER SUPPLY WORKS
-
-
-
M&L for steel tubing Galvanised medium grade 100mm bore pipe laid in trenches complete all as specfied and as directed.
100
-
-
M&L for steel tubing Galvanised medium grade 80mm bore pipe laid in trenches complete all as specfied and as directed.
50
-
-
M&L for steel tubing Galvanised medium grade 50mm bore pipe laid in trenches complete all as specfied and as directed.
25
-
-
S&F sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, class PN 1.6, for 80mm bore pipe complete all as specified and as directed.
5
-
-
S&F sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, class PN 1.6, for 100mm bore pipe complete all as specified and as directed.
5
-
-
S&F Gun metal golbe or gate valve with iron wheel screwed both ends for 50mm bore iron pipe complete all as specified and as directed.
5
-
-
S&F Cast Iron Air Valve with Two air outlets suitable for 50 mm bore pipe complete all as specified and as directed.
2
-
-
S&F Cast Iron Air Valve with Two air outlets suitable for 100mm bore pipe complete all as specified and as directed.
2
-
-
S&F Foot Valve conforming to IS-4038, suitable for 100 mm bore pipe complete all as specified and as directed.
5
-
-
S&F Valve reflux with by pass arrangement suitable for 100 mm bore pipe complete all as spefied and as directed.
5
-
-
S&F pressure guage100 mm dia with ball valve of pressure 0-21Kgs rating, with and including all arrangement for fixing with pipe line complete all as spefied and as directed.
5
-
-
M&L for construction of brick masonary valve pit 60xcmx60cmx60cm (internal dimesion ) with frame of angle iron of size 40mmx40mmx6mm and MS sheet cover 3mm thick with and including locking arrangement and handle all as shown in Drawing No CEAF/STD-28/94 sheet 1/2 & dated 01.02.1994 duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as spefied and as directed.
5
-
-