Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Eprocure
Opening Date31 Aug 2024
Closing Date27 Sep 2024
Tender Amount₹ 41,68,000
Costs
EMD
₹ 83,360Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668755_1Bid Award Id
ViewTender No
GE/863/EWS-T-27 OF 2024-25 PROVN OF CERTAIN SANCTIONED WORKS ATTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF CERTAIN SANCTIONED WORKS AT KARCHAM IN THE AREA OF AGE BR I AND AGE EM WE POOH UNDER GE 863 EWS
BOQ Items
Dismantling of cross arms of MS Channel or angle sections complete all as specified and directed by Engr-in-charge.
1
-
-
Supply, laying and testing of LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sq mm 3.5 core as per IS specifications complete all as specified and directed by Engr-in-charge.
360
-
-
All as per ser item No 5 here in before but of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
500
-
-
All as per ser item No 5 here in before but of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
270
-
-
All as per ser item No 5 here in before but of 16 Sqmm 4 core complete all as specified and directed by Engr-in-charge.
750
-
-
All as per ser item No 5 here in before but of 16 Sqmm 2 core complete all as specified and directed by Engr-in-charge.
350
-
-
All as per ser item No 5 here in before but of 10 Sqmm 2 core complete all as specified and directed by Engr-in-charge.
250
-
-
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for foundation, laying of pipes, cables etc. or for shafts, wells, cesspits, manholes, pier holes, poles etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil for complete all as specified and directed.
261.8
-
-
Returning filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge.
157.99
-
-
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
115.89
-
-
M & L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed.Note:- punned thickness shall be taken for payment.
76.32
-
-
Supply and laying for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
8.48
-
-
M&L for High density Polyethylene pipes (HDPE) of Pressure rating PN-10 for mechanical protection of UG Cable 240 Sqmm fixed complete to walls, ceilings or floors ext size 50 mm bore, complete all as specified and directed by Engr-in-charge.
360
-
-
Supply and fixing in replacement of 2 runs of 1.5 Sqmm PVC FRLS insulated stranded copper cable for connection of street light including PVC conduit 20 mm external dia, medium grade, fixed on pole with proper clamping/ saddling etc complete all as specified and directed.
60
-
-
Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
13
-
-
Supply and fixing in replacement of PVC Terminal / junction pole box, 4 pole strips, mounted on DMC insulator and MCB SP 6 Amps, 10 KA, Size 310 x 210 x 120mm and fixed with MS flat iron clamps to pole complete all as specified and as directed.
13
-
-
S&F in replacement of bracket made of GI pipe light grade 40mm bore bend to shape in 120 degree of 1.2 m in length suitable for fixing street light luminaire and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed.
12
-
-
Supply and fixing in replacement of digital automatic street light control panel of 12 KW, made of extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Provided with Protection Degree IP 54 and Class H Insulation, complete all as specified and directed by Engr-in-charge.
1
-
-
Supply, fabrication and testing in replacement of outdoor type LT panel/DBs of board factory made CPRI approved with IP 54 grade of protection and installed at a height of 1 feet over suitable PCC platform fabricated with suitable angle iron (50x50x6mm thick) bottom leg supports for resting independently cubical, compartmental type with double hinged front openable doors, half turn type operating knobs for incoming feeders and outgoing feeders made of 3.15 mm thick CRCA sheet metal powder coated for outer sheet of panel and 2 mm thick CRCA sheet for partition and compartment doors and with suitable capacity of aluminum bus-bar not less than 160 Amps capacity for each phase supported by suitable insulators and covered with colour coded heat shrinkable sleeves along with wiring of panel with suitable size of copper conductor cable for accessories including provision of necessary cable entry / exit boxes complete all as specified and directed by Engr-in-Charge.
Incomer:
(I) MCCB 100 Amp 25 KA 4P 415 Volts AC-1 nos
Out going:
(I) MCCB 63 Amp 25 KA 4P 415 Volts AC-1 Nos
(II) MCB TPN 40 Amps 10KA 4P 415 Volt AC-3 Nos
3
-
-
S&F GI Tube 50 MM Light Grade laid in trenches under road or fixed to wall as mechanical protection for UG Cables complete all as specified and as directed by Engr-in-charge.
28
-
-
M & L in replacement for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25metres deep below normal ground level) with top edge of the plate not less than 1.5meter below normal ground level ,connected to and including using galvanized iron wire of 4.0 mm dia as earthling lead by means of bolts nuts, cheek nuts and washers of galvanized iron or steel .earth plate surrounded by alternate layers packed with char coal dust and common salt ,15cm thick and 15cm wide all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40mm dia GI protection pipe medium grade all as shown in electrical plate no-3 of SSR part-I and connected to earthling test point, and including testing on completion all as specified location and as directed by Engineer-in -charge.
Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately.
2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost.
5
-
-
Taking out / taking down old unserviceable damaged HDPE pipe and GI pipe of 20/25/40 mm size from excavated trenches or from wall/floor including removing of fittings complete all as specified and directed by Engr-in-Charge.
1430
-
-
Supply, laying and testing 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water, including all PP-R Plain & brass threaded polypropylene random fitting of size 40mm (outer dia) all as specified and directed.
Note: Excavation and earth work shall be paid separately.
650
-
-
All as per ser item No 26 here in before but of size 25 mm (outer diameter of pipe) complete all as specified and directed.
500
-
-
All as per ser item No 26 here in before but of size 20 mm (outer diameter of pipe) complete all as specified and directed.
280
-
-
Supply and fixing of HDPE Pipes PN 10, of size 63mm bore for mechanical protection of PP-R Pipe line complete all as specified and directed.
630
-
-
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 40 mm dia complete all as specified and directed.
20
-
-
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 25mm dia complete all as specified and directed.
170
-
-
Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 20mm dia complete all as specified and directed.
200
-
-
M & L for providing aluminium cladding over insulation of PPR pipe of size 40mm dia with aluminium sheet having thickness 0.1mm complete all as specified and directed.
20
-
-
M & L for providing aluminium cladding over insulation of PPR pipe of size 25mm dia with aluminium sheet having thickness 0.1mm complete all as specified and directed.
170
-
-
M & L for providing aluminium cladding over insulation of PPR pipe of size 20mm dia with aluminium sheet having thickness 0.1mm complete all as specified and directed.
200
-
-
Supply & fixing PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 40mm, complete all as specified and directed.
3
-
-
Supply & fixing PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 25mm, complete all as specified and directed.
6
-
-
Supply & fixing PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 20mm, complete all as specified and directed.
5
-
-
Supply and fixing ball brass float valve, high pressure, with polythene float and flynut for 40mm PPR Pipe complete all as specified and directed.
1
-
-
Supply and fixing ball brass float valve, high pressure, with polythene float and flynut for 25mm PPR Pipe complete all as specified and directed.
5
-
-
S&F in replacement of PUF insulated cylndrical tank of capacity 500 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :-
(a) Inner tank will be double layered HDPE food grade material.
(b) Outer 4mm thick FRP jointless casing of tank.
(c) Thickness of PUF insulation shall be 75mm.
(d) Minimum density of PUF insulation shall be 44 kg per/cum+ 10%.
Note: Dismantling of old u/s PVC water tank to be included in the rate quoted.
5
-
-
S&F in replacement of PUF insulated cylndrical tank of capacity 3000 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specification :-
(a) Inner tank will be double layered HDPE food grade material.
(b) Outer 4mm thick FRP jointless casing of tank.
(c) Thickness of PUF insulation shall be 75mm.
(d) Minimum density of PUF insulation shall be 44 kg per/cum+ 10%.
Note: Dismantling of old u/s PVC water tank to be included in the rate quoted.
1
-
-
M&L for construction of Valve pit chamber 40cm x 40cm (inner dimension) and 0.6 cm deep, from the top of MS cover fixed on PCC Base, top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class "B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessary earth work in any type of soil including returning filling in and disposal of surplus soil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8, type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed by Engineer - In - Charge. Note: Exacavation, returning filling, removing etc. is deemed to be included in quoted rate of this item.
2
-
-
M&L for PCC 1:4:8 type D-2 using 40mm stone agg as in foundation, filling and mass concrete of retaining walls, etc. complete all as specified and directed by Engr-in-Charge.
1.9
-
-
M&L for pre-cast cement concrete hollow block masonry type C-1 1:3:6 (using 20mm aggregate) exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
13.5
-
-
M&L for rendering 15mm thick on Brick / Block masonary / concrete surfaces in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed.
70.9
-
-
M&L for precast solid block masonry of block 1:3:6 type C-1 (using 20 mm aggregate) wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
6.98
-
-
M&L For RCC 1:2:4 type B-1, ( using 20 mm graded stone aggregate ) as in beams, cantilevers, bed block, bressummers, lintels over 1.5m span , including necessary form work etc. (reinforcement to be measured separately), complete all as specified and as directed.
0.72
-
-
M&L for Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) in foundations, footing, plinth beams, bases for columns and mass concrete (reinforcement to be measured separately) complete all as specified & directed.
2.32
-
-
M&L for Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) in columns (reinforcement to be measured separately) complete all as specified & directed.
1.26
-
-
M&L for Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) in chajjas and like (reinforcement to be measured separately) complete all as specified & directed.
0.06
-
-
M&L for use & waste of form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified & directed.
8
-
-
All as per item no 52 here-in-before but for sides of square column for fair finished surface complete all as specified and directed.
4.2
-
-
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed.
7.85
-
-
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
206
-
-
M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
100
-
-
M&L rendering 15mm thick on conc surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
29.9
-
-
M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed.
7.5
-
-
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley, gutters etc. complete all as specified and directed.
1
-
-
S&F Framed work such as roof trusses (framed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(Gde E-250) Quality A complete all as specified and directed.,
92
-
-
S&F for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding etc. Fe-410-W(gde-E-250) quality B, complete all as spfd and directed by Engr-in-charge.
8
-
-
M&L for preparation of new or previously untreated surfaces of steel/iron of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and directed.
10
-
-
S&F Anodised aluminum snap grid framed work for false ceiling of size 605x605 mm incl hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long complete all as specified and directed.
4
-
-
M&L for false ceiling with gypsum board, perforated type, ,factory made matt finish surface/pre painted surface, 600 x 600 mm in size and 12 to 15 mm thick on aluminum snap grid 605 X 605 mm as in ceiling, complete all as specified and directed.
4
-
-
S&F For Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed.
0.25
-
-
S&F For 5mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and directed.
0.25
-
-
S&F 2nd class hard wood plain solid straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamferred, put together with glue pinned at joints complete all as specified and directed by Engr-in-charge.
0.03
-
-
S&F factory made plain framed panelled shutters 35mm thick of 2nd class hard wood (any number of panels) with panels of timber flat on both sides feather edges or panel of 9mm BWP commercial ply over 12mm thick veneered panticle board with commercial face veneers fixed to chowkhat . The size of rail and stile as per IS : 1003 (Part-1), kiln seasoned and chemically pressure treated complete all as spfd and directed by Engr-in-charge.
2.1
-
-
M&L for preparing new surface of wood of any decription , not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
2.1
-
-
M&L for Mild Steel works as in bands straps, hold fasts etc, conforming to IS-2062-2006 (Fe-290), embedded portion duly painted with bituminious paint and sanded, complete all as specified and directed by Engr-in-charge.
0.54
-
-
M&L for Cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in copings, bed plates, fixing of hold fasts and other similar works and the like incl weathering, slightly rounded or chamfered angles and throating as directed incl use and waste of necessary form work complete all as spd and directed.
0.02
-
-
S&F for Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as spd and directed.
3
-
-
S&F for barrel tower bolts aluminum anodised of size 150 mm long complete all as spd and directed.
2
-
-
S&F for 150 mm long aluminum anodised handles or extruded section complete all as specified and directed.
2
-
-
S&F for 300mm long Aluninum alloy, anodised, sliding door bolt with hasp & staple, (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminum alloy complete all as specified and directed.
1
-
-
S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube etc complete all as specified and as directed.
5.2
-
-
S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed.
2.1
-
-
S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specifeid and directed.
10
-
-
S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
15
-
-
S&F for vitreous china wash basin, white, flat back, size 630 mm x 450 mm, brackets, waste coupling, etc. also including fixing of tap, waste chain and plug and porcelain stopper, complete all as specified and directed.
1
-
-
S&F Vitreous china squatting pan 'Orissa pattern' size 580X 440 mm white with integral foot rest (including fixing of flushing cistern and flush pipe) including connection to trap, concrete and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, complete all as specified and directed.
1
-
-
Supply only 10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed.
1
-
-
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
1
-
-
Supply only 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' woth long shanks and flynuts, screwed for iron pipe complete all as specified and directed.
1
-
-
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
4
-
-
S&F for 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed.
2
-
-
S&F 15mm dia stop valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed.
4
-
-
S&F for 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
20
-
-
S&F for 110mm PVC(SWR) bend any radius complete all as specified and directed.
2
-
-
S&F for 110mm PVC(SWR) junction single (single T) equal or unequal complete all as specified and directed.
2
-
-
M&L 110mm PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed.
1
-
-
S&F 110mm PVC(SWR) vent cowl complete all as specified and directed.
1
-
-
S&F 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed.
1
-
-
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
141
-
-
S&F for 500 ltr. Capacity rotational moulded polyethylene water storage tanks tripple layered cylindrical vertical with closed top hoisted and fixed in position complete all as specified in SSR Part I & II, complete all as specified and directed.
1
-
-
S&F for 20mm bore ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
1
-
-
S&F 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
2
-
-
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface rough to receive tiles complete all as specified and directed.
4
-
-
M&l for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. over and including 15 mm thick screed in CM 1:6 complete all as specified and directed.
4
-
-
M&L for glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7 mm / 450mm x 350mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed.
18
-
-
M&L for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat primer on walls complete all as specified and directed.
13
-
-
M&L for preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint complete all as specified and directed.
21
-
-
Construction of 10 users Septic tank to carry sewage and sullage water, with RCC (1:1.5:3), B-1 Roof Slab all as per shown in Drg No. STD 1320 (C) Sheet 1/3 to 3/3 with following specification, including excavation in, return filling & removing any type of soil, precast cement concrete (20mm graded stone aggregate) C-1 block masonary in Walls , Base Slab , Baffle walls of RCC (1:1.5:3), Vent shaft , manhole openings with cover connection Complete. Note:- (i) Precast cement concrete (20mm graded stone aggregate) C-1 block masonary as in walls as 700/600/500/400mm in lieu of 690/575/460/345mm respectively wherever shown in drawing.
(ii) Stone boulders filling will be done in lieu of brick bats filling in lieu brick bats where ever shown in drawings.
1
-
-
Construction of Soak well 1.80m dia and 3.0m effective depth as specified on STD 1173(C) sheet 1R/2 with following specification free board as per site requirement including excavation in, return filling, & removing any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of precast cement concrete (20mm graded stone aggregate) block masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with Stone boulders of size, complete all as specified on STD 1173(C) sheet 1R/2.
Note:- (i) precast cement concrete (20mm graded stone aggregate) C-1 block masonary in Walls as 700/600/500/400mm in lieu of 690/575/460/345mm respectively wherever shown in drawing.
(ii) Stone boulders filling will be done in lieu of brick bats filling in lieu brick bats where ever shown in drawings.
1
-
-
M&L for point wiring using approved colour coding as per IS, 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC Conduit with accessories having ISI mark fixed on wall surfaces / ceiling including provision PVC Box on top for fixing switches sockets etc. complete all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
4
-
-
M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge.
3
-
-
Supply and fixing surface & wall mounted LED 20W tube light fitting batten 4 feet, mirrorlite slim type with extruded aluminium housing alongwith 20W LED lamp PC body with all accessories complete all as specified and directed by Engg-in-Charge.
1
-
-
Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engg-in-Charge.
1
-
-
Supply and fixing 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode complete all as specified and directed by Engg-in-Charge.
1
-
-
Supply & Fixing bulk head light with 10 W LED Lamp complete all as specified and directed by Engg-in-Charge.
1
-
-
S&F for PVC exhaust AC, Single Phase 300mm sweep 1400 RPM, with louvre complete all as per specified and directed by Engineer-in-Charge.
1
-
-
Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 4 way 240 volt complete all as specified and directed by Engineer-in-Charge
1
-
-
S&F SPN 32 Amp,10 KA complete all as specified and directed by Engineer-in-Charge
1
-
-
S&F MCB SP 6 Amp to 20 Amp, 10 KA complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply, laying, fixing or passing & testing through pipe, 1100 Volts grade heavy duty cable with Two Core PVC insulated aluminum stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq mm nominal cross section in service connection complete all as specified and directed by Engr-in-Charge.
60
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25metres deep below normal ground level) with top edge of the plate not less than 1.5meter below normal ground level ,connected to and including using galvanized iron wire of 4.0 mm thick as earthling lead by means of bolts nuts, cheek nuts and washers of galvanized iron or steel .earth plate surrounded by alternate layers packed with char coal dust and common salt ,15cm thick and 15cm wide all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40mm dia GI protection pipe medium grade all as shown in electrical plate no-3 of SSR part-I and connected to earthling test point, and including testing on completion all as specified location and as directed by Engineer-in -charge.
Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately.
2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost.
1
-
-
S&F and connection of GI pipe of size 25 mm bore dia, medium grade including GI fittings and fixed complete to walls and ceilings or laid in floors, complete, all as specified and directed.
10
-
-
Supply and fixing of Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed size 25 mm dia including connection and testing, complete, all as specified and directed.
1
-
-
Supply and fixing of Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed size 20 mm dia including connection and testing, complete, all as specified and directed.
1
-
-
M&L for cutting of existing steel tubing of size 25 mm dia for alterations or additions, done in position without taking down, complete, all as specified and directed.
Note: Each cut shall be measured.
1
-
-
Schedule of Credit
-