Military Engineer Services Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jun 2024
Closing Date5 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR / MAINT OF ELECTRIC MOTORS AND PUMP SET, STARTERS, MCC/ ATS PANELS, WATER MONITORING SYSTEM AND CONNECTED WORKS OF VARIOUS MES INSTALLATION AT KASAULI UNDER GE KASAULI
REPAIR / MAINT OF ELECTRIC MOTORS AND PUMP SET, STARTERS, MCC/ ATS PANELS, WATER MONITORING SYSTEM AND CONNECTED WORKS OF VARIOUS MES INSTALLATION AT KASAULI UNDER GE KASAULI
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Replacement of gun metal impeller

24

-

-

... More
Replacement of gun metal Bush

48

-

-

... More
Replacement of Gland Sleeve

8

-

-

... More
Replacement of body Neck ring gun metal

48

-

-

... More
Replacement of Pump shaft stainless steel

8

-

-

... More
Counter Plate stainless steel

8

-

-

... More
Diffuser Packing

48

-

-

... More
Impeller brazing machining and reboring

24

-

-

... More
New Key way of impeller disc

24

-

-

... More
Diffuser outer dia brazing and machining

24

-

-

... More
Impellers outer dia brazing and machining

24

-

-

... More
Disconnecting /unscrewing coupling for 150 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:- Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.

6

-

-

... More
Coupling Set suitable for 150 HP Pumping set

6

-

-

... More
Replacement of gun metal impeller

36

-

-

... More
Replacement of gun metal Bush

72

-

-

... More
Replacement of Gland Sleeve

12

-

-

... More
Replacement of body Neck ring gun metal

72

-

-

... More
Replacement of Pump shaft stainless steel

12

-

-

... More
Counter Plate stainless steel

6

-

-

... More
Diffuser Packing

6

-

-

... More
Impeller brazing machining and reboring

36

-

-

... More
New Key way of impeller disc

36

-

-

... More
Diffuser outer dia brazing and machining

36

-

-

... More
Impellers outer dia brazing and machining

36

-

-

... More
S & F in replacement of pressure gauge upto 100 Kg/sqcm And connected to pump set with and including syphon type pipe (as per existing sample), complete all as speciified and as directed by Engineer-in-charge.

6

-

-

... More
S&F in replacement of ball bearing 6314, complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement of ball bearing 6319/6319-C3, including replacement of old grease with new complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement of roller bearing NU 307, including replacement of old grease with new complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
Disconnecting existing electric motor and dismantling from foundation and transporting the same to the workshop for repairs and refixing the same on existing location after repair & making electric connection including testing and commissionig complete.The job including taking out burnt winding and rewinding the motor with super enamelled copper wires as per existing guage and size including super quality of varnish and insulating material as required for 220 HP, electric motor complete all as speciified and as directed by Engineer-in-charge. Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.

5

-

-

... More
-ditto- all asper Item No. 7.00 above but of capacity 150 HP, motor complete.

5

-

-

... More
-ditto- all as per item No. 7.00 above but of capacity 7.5 HP, motor complete.

1

-

-

... More
Disconnecting /unscrewing Auto Transformer Starter Panel of capacity 150/ 220 HP, disconnecting all electric connections and carrying out necessary repair at site with replacement of parts as under complete all as specified including testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid as under:

8

-

-

... More
S&F in replacement Electronic over current relay cap 0.5 – 60A 220V AC complete with arrangement for over current, phase reversal, under current and phase imbalance protection suitable for 150/250 HP ATS Panel complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement Three pole power contactor, AC Control, AC3 Rating 95A/ 47 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement Three pole power contactor, AC Control, AC3 Rating 140A/ 75 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement Three pole power contactor, AC Control, AC3 Rating 265A/ 140 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.

4

-

-

... More
S&F in replacement Three pole power contactor, AC Control, AC3 Rating 300A/ 160 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement No volt coil complete all as speciified and as directed by Engineer-in-charge

2

-

-

... More
S&F in replacement Timer complete all as speciified and as directed by Engineer-in-charge

2

-

-

... More
S&F in replacement Digital voltmeter of size 96 x 96mm range 0 to 500 volts, 3 phase with iin built in selector switch, suitable for CT operation - 01 set. all as speciified and as directed by Engineer-in-charge

4

-

-

... More
S&F in replacement Digital Ammeter range 0 to 400 Amps, 3 phase with iin built in selector switch, suitable for CT operation - 01 set. all as speciified and as directed by Engineer-in-charge

3

-

-

... More
S&F in replacement Indicator set RYB 01 set of 3 pcs all as speciified and as directed by Engineer-in-charge

10

-

-

... More
S&F in replacement Selector switch all as speciified and as directed by Engineer-in-charge

3

-

-

... More
M&L for reparing/servicing of APFC panel board of Cap 100 KVAr by replacing the all defective components with new components, rewiring, cleaning, testing, reconnecting, reinstalling and commissioning the APFC panel board complete all as direcetd by Engineer-in-Charge. Note : Supply of cables, wires & other minor spare parts etc will deemed to be included in the quoted rate.

4

-

-

... More
S & F in replacement of cooling fan for 100 KVAr capacity APFC panel with proper connection, complete all as direcetd by Engineer-in-Charge.

12

-

-

... More
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 25mm GI Pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.

5

-

-

... More
Disconnecting of old unserviceable chemical earthing replacement with GI earth electrode with medium grade of size 50mm dia upto 2 meter below ground level Installation, testing and commissioning of chemical earthing complete with buried directly in ground vertically to a depth not less than 2mtr below normal ground level earth electrode GI pipe connected to and incl galvanised earthing lead strip 32 x 6mm as main earthing lead by means of tinned copper/ brass bolts, nuts, check nuts and washer beside brazing at all joints as directed and earthing lead protected with 40mm dia light grade GI pipe from electrode and upto incl the earth test point, including alternate layers of 150mm thickness each of charcoal, common salt, magnisium sulphate/ chemical and as per manufacturer's recommendation including below the copper electrode also and excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia MS deformed bars @75 mm C/C both ways incl MS angle iron frame of size 40mmx40mmx3mm and incl testing the earthing on completioin, complete all as specified. The result of the earth resistance should be less that 1 Ohm and recorded results to be submitted to Engr-in-Charge. Note :- (i)Old earthings are conventional type and sch of credit has been accounted for accordingly. (ii) Chemical use for earthing should be Marconite.

5

-

-

... More
S&F in replacement MCCB 630 Amps 4 pole, 50 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement MCCB 400 Amps 4 pole, 50 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement MCCB 200 Amps 4 pole, 35 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.

2

-

-

... More
M&L Cross arms bracings, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Material & labour for cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of electric poles, sturts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified.

1

-

-

... More
Supply & Fixing in repair/replacement GI pipe 100 mm dia light grade along pole for covering cable including clamp, nuts, bolts & washers etc complete all as specified.

15

-

-

... More
Supply & Fixing including taking down old U/S double walled corrugated HDPE duct pipe of 63 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete all as specified.

40

-

-

... More
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 95 Sqmm, Grade As Per IS 7098 (Part -1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles including taking down old U/S cable complete all as specified and as directed by Engr-in-charge.

120

-

-

... More
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 120 Sqmm, Grade As Per IS 7098 (Part 1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles including taking down old U/S cable complete all as specified and as directed by Engr-in-charge.

180

-

-

... More
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 185 Sqmm, Grade As Per IS 7098 (Part 1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles including taking down old U/S cable complete all as specified and as directed by Engr-in-charge.

180

-

-

... More
Taking out complete Auto Trasformer Panel (ATS) set including all electric connection , carrying 15 Mtr distance and making new suitable foundation for the ATS panel and grouting the nut and bolts and fixing the same ATS panel including making electric connection and testing the panel complete all as specified and direcetd by Engr-in Charge.

4

-

-

... More
S & F in replacement of Copper Thimble of below mentioned sizes as complete all as specified and directed by Engineer in charge.

-

-

-

... More
220mm

18

-

-

... More
150mm

18

-

-

... More
120mm

18

-

-

... More
90mm

28

-

-

... More
S &F in replacement of relay of ATS panel IEC 255 of 150 VAC, 5 amp - 28v DC, 8 pin with base replace with existing make and make sure proper working of panel complete all as specified and directed by engr-in-charge.

8

-

-

... More
S & F in replacement of hex rubber coupling 6MM with suitable bolt, nut , and waher for pump and motor coupling all as per existing size and make complete all as specified and directed by Engr-in-charge .

38

-

-

... More
S&F for replacement of battery 12 V 180 Ah maintenance free, including taking down all as specified and direcetd by Engr-in-Charge

3

-

-

... More
S & F in replacement of Start Push button for ATS Panel all as per existing and all as specified and direcetd by Engr-in-Charge

5

-

-

... More
S & F in replacement of Stop Push button for ATS Panel all as per existing and all as specified and direcetd by Engr-in-Charge

5

-

-

... More
S & F in replacement of MC Contactor of 25 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

2

-

-

... More
S & F in replacement of MC Contactor of 10 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

6

-

-

... More
S & F in replacement of MC Contactor of 05 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

6

-

-

... More
S & F in replacement of Heavy Duty Capacitor of 20 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

6

-

-

... More
S & F in replacement of Heavy Duty Capacitor of 10 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

4

-

-

... More
S & F in replacement of Heavy Duty Capacitor of 1 to 5 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.

4

-

-

... More
S&F in replacement of Rubber Mat of size (1 Meter x 2 meter x 19mm) uses in pumps house for safety purposes for operators as specified and directed by Engineer in charge.

20

-

-

... More
S&F in replacement of stud for 220/150HP pumpset (as per existing sample), complete all as specified and directed by Engineer in charge.

30

-

-

... More
S & F in replacement of current transformer 250/5A, Class 1 ID 45 CT With 15 VA for Ammeter with current rating 5.0 amps for ATS panel, all as specified and direcetd by Engr-in-Charge.

1

-

-

... More
S & F in replacement of Bypass Switch of rating 400A (as per existing sample) for Servo Voltage Stablizer of rated capacity 250KVA; rated voltage 240V with 3 no of phases , all as specified and direcetd by Engr-in-Charge.

1

-

-

... More
S&F in replacement of shock treatment chart in multi languages i.e english and hindi of size 2 x1 Sqm in wooden base with proper frame and arrangement to fix, complete all as specified and directed by engineer in charge.

6

-

-

... More
S & F illuminated display board with name of water supply installations and distribution tanks of size 1.25mx0.2mx0.9m (LXBXH) with flex of light blue (MES Colour ) colour of letters shall be white, outer side fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, inner side fabricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC 1:2:4 type B1 for foundation including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimension including its fixing arrangement and written letters in capital, size of letters proportion with overall size of baord complete all as specified and as directed. Note:- (i) Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-Charge (ii) Each board display name shall be given seperately.

3

-

-

... More
S & F in replacement of Display board for water supply installation/equipments (Pump, motors, Transformers, VCB, APFC Panel, Stabilizers etc.) by writing name on Acrylic board of blue color of size 60x10 cm of thickness 5 mm letter shall be of white color in size 5 cm including fixing on suitable place near equipment with self adhesive tape on both side or with hanging chain as required at site complete all as specified and directed by Engr-in-Charge.

16

-

-

... More
M & L in relacement for pacific Hydrolube Hydraulic oil of viscosity ISO-32/46 for pump lubrication top up to 80% in all pumps complete all as specified and directed by Engr-in-charge.

80

-

-

... More
S & F in replaement of ultrasonic level transmitter with black light and extended display suitable for tank of depth 0 to 10 meter with analog and modbus output panel mounted indicator for level transmitter for displaying data of level of tank protection accessories for level transmitter for open and under ground water tanks including connections with suitable wirings and switch controls.complete all as specified and directed by Engr-in-charge. NOTE:- (i) Testing report of the euipment shall be submitted to Engr-in-charge.

7

-

-

... More
M & L in replacement of coarse aggregates, grading I, 90 MM to 40MM for laying on ground under poles as base layer for HT 2 Pole and 4 Pole structure with outer boundary of bricks lay poperly complete all as specified and directed by Engr-In-charge.

6

-

-

... More
M & L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated stuation for loop earthing etc. as required but size 25x4 mm including insulator for GI earthing strip properly layout with angle of turn 90 degree including testing complete all as specified and directed by Engineer -in-charge.

80

-

-

... More
Amount of credit of Rs. 219142.63 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.