Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date30 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/ REPLACEMENT OF SOLAR WATER HEATERS, SOLAR PANEL, DG SET, SECURITY LIGHT, LIGHTENING CONDUCTOR, STREET LIGHTS, JUNCTION BOX, STREET LIGHT TIMER AND CERTAIN OTHER WORKS AT AOR O AGE EM KASAULI AND REPAIR/ REPLACEMENT OF AIR CONDITIONER, REFRIGERATIO
REPAIR/ REPLACEMENT OF SOLAR WATER HEATERS, SOLAR PANEL, DG SET, SECURITY LIGHT, LIGHTENING CONDUCTOR, STREET LIGHTS, JUNCTION BOX, STREET LIGHT TIMER AND CERTAIN OTHER WORKS AT AOR O AGE EM KASAULI AND REPAIR OF AIR CONDITIONER AT KASAULI
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.

3

-

-

... More
Material and labour for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed.

850

-

-

... More
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.

2050

-

-

... More
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 Sqmm 2 core with required aluminium cable lugs all as specified and directed.

600

-

-

... More
All as per item No. 6.00 here-in-before but 10 Sqmm 2 core complete all as specified and directed.

650

-

-

... More
All as per item No. 6.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed.

800

-

-

... More
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI earth strip protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (light grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.

16

-

-

... More
Material & Labour for Installation, testing and commissioning of chemical earthing complete with 50 mm dia copper pipe filled with chemical/ magnisium sulphate as manufacturer's recommendation buried directly in ground vertically to a depth not less than 2mtr below normal ground level, earth electrode 25 x 3 mm copper strip connected to test point up to 7 mtr length with copper/ brass bolts, nuts, check nuts and washer beside brazing at all joints as directed and earthing lead protected with 40 mm dia light grade GI pipe from electrode and upto the earth test point with and including excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 50 mm thick in RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia MS deformed bars @75 mm C/C both ways incl MS angle iron frame of size 40mm x 40mm x 3mm and incl testing the earthing on completion including taking down of old unserviceable earthing of any type, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Quoted rates shall be deemed to include for earthing strip with protection pipe up to 7 Mtr length. (ii) earth resistance should be less that 1 Ohm and recorded results to be submitted to Engr-in-Charge. (iii) Old earthings are conventional type and sch of credit has been accounted for accordingly.

4

-

-

... More
Supply and fixing GI tubing light grade 50mm bore, ISI marked, for cable protection in road crossing all as specified and directed.

100

-

-

... More
Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 4.0 sqmm and overall PVC sheathed to pass through the street light pole from junction box to street light fitting incl dismantling taking down unserviceable one all as specified and directed.

300

-

-

... More
Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed.

650

-

-

... More
All as per item No. 12.00 here-in-before but 10 Sqmm complete all as specified and directed.

850

-

-

... More
Material and labour for painting of steel tubular pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate white and black paint strip 30 cm wide (5 Nos) with synthetic enamelled paint all as specified and directed.

350

-

-

... More
Dismantling / taking down carefully flood/street/gate light fittings of any type, any make and any capacity from Pole/Building for repair or for fixing in other position complete all as specified and directed.

137

-

-

... More
Supply and fixing in replacement LED 48/50 watts street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed.

90

-

-

... More
Supply and fixing of 45 watts Inverter type LED Street Light with IR Sensor for automatic ON/OFF of street lights and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be pressure die cast and system efficiency 100LPW,CRI 70,CCT 5700K ,PF 0.9, THD15% .

25

-

-

... More
Supply and fixing Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismantling taking down unsv complete all as specified and directed.

85

-

-

... More
Supply and fix in replacement of sintex box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed by Engr-In-Charge.

60

-

-

... More
Supply and fixing in replacement of 200 watts flood light Warm white/ coolday light in colour as per rquirement,  LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase,  etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Material and labour for complete servicing/ cleaning of DG Sets with kerosene or by blower where necessary , prevention of leakage of fuel /oil/ water/coolant, tightening of loose nuts and bolts , retensioning of fan belt, descaling of radiator by cleaning with cleaning agent, cleaning of fins by applying pressurised air using blower including replacement of rubber housing set complete, checking of all electrical connections and testing on full load of DG sets with taking out and replacement of defective parts. Note :- The quoted rates of the contractor includes for the following : (i) Fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) Supply and replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above. (iii) Labour for replacement of lubricating oil (Cost of lubricating oil shall be measured and paid separately) (iv) Make of DG sets installed are one of the make mentioned in the item. Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced. (v) Major parts required to be replaced shall be measured and paid separately under respective items of BOQ.

-

-

-

... More
DG set 10 KVA , Installed at Signal Centre Dagshai

1

-

-

... More
DG set 30 KVA , Installed at Kasauli

1

-

-

... More
DG set 45 KVA , Installed at Section Hospital Dagshai

1

-

-

... More
DG set 62.5 KVA , Installed at Kasauli

1

-

-

... More
DG Set 100 KVA, Installed at Dhobi ghat at Dagshai

1

-

-

... More
DG Set 125 KVA, Installed at Kasauli

1

-

-

... More
DG Set 250 KVA, Installed at Kasauli

3

-

-

... More
Material & Labour for top up of Coolant for the DG Sets complete all as specified and directed .

60

-

-

... More
Supply and filling /top up of Distilled water for the batteries of the DG Sets complete all as specified and as directed.

35

-

-

... More
Material & Labour for Engine belt off size for 10 KVA DG Set (set of two) complete all as specified and directed.

1

-

-

... More
All as per serial item No 24.00 above but for 30 KVA DG Set.

1

-

-

... More
All as per serial item No 24.00 above but for 45 KVA DG Set.

1

-

-

... More
All as per serial item No 24.00 above but for 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 24.00 above but for 100 KVA DG Set.

1

-

-

... More
All as per serial item No 24.00 above but for 125 KVA DG Set.

1

-

-

... More
Material & Labour for Diesel filter element with gasket for 10 KVA DG Set complete all as specified and directed .

1

-

-

... More
All as per serial item No 25.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 25.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 25.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 25.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 25.00 above but 125 KVA DG Set.

1

-

-

... More
All as per serial item No 25.00 above but 250 KVA DG Set.

3

-

-

... More
Material & Labour for Oil filter element complete for 10 KVA DG Set complete all as specified and directed .

1

-

-

... More
All as per serial item No 26.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 26.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 26.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 26.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 26.00 above but 125 KVA DG Set.

1

-

-

... More
All as per serial item No 26.00 above but 250 KVA DG Set.

3

-

-

... More
Material & Labour for Air cleaner Element complete Set for 10 KVA DG Set complete all as specified and directed .

1

-

-

... More
All as per serial item No 27.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 27.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 27.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 27.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 27.00 above but 125 KVA DG Set.

1

-

-

... More
All as per serial item No 27.00 above but 250 KVA DG Set.

3

-

-

... More
Material & Labour for Air filter (inner & outer) complete Set for 10 KVA DG Set complete all as specified and directed .

1

-

-

... More
All as per serial item No 28.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 28.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 28.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 28.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 28.00 above but 125 KVA DG Set.

1

-

-

... More
All as per serial item No 28.00 above but 250 KVA DG Set.

3

-

-

... More
Material & Labour for New nylon reinforced PVC fuel pipe complete Set for 10 KVA DG Set complete all as specified and directed .

1

-

-

... More
All as per serial item No 29.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 29.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 29.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 29.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 29.00 above but 125 KVA DG Set.

1

-

-

... More
Material and labour for replacement of battery 12V, 180 Ah, maintenance free batteries for DG sets with Electro plates including required length of battery lead both positive & negative, battery terminals complete all as specified and as directed.

6

-

-

... More
Material and labour for Draining out old Engine oil from Chamber, cleaning of oil sump and filling/ topping up of new oil conforming to specification complete all as specified and directed .

350

-

-

... More
Material and labour for repair to self starter by taking out defective parts and replacement of armature, field coils, carbon brush, pinion, shocker arm, bearings complete including testing all as specified and as directed.

2

-

-

... More
Material and labour for Overhauling of FIP Pump & calibration complete all as specified of the DG Set 10 KVA complete all as specified and as directed.

1

-

-

... More
All as per serial item No 33.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 33.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 33.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 33.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 33.00 above but 125 KVA DG Set.

1

-

-

... More
Material and labour for taking out the exhaust unit from 10 KVA DG set for cleaning of silencer, silencer pipe by using wire brush etc and refix in the same position with necessary welding nuts and bolts complete all as specified and as directed.

1

-

-

... More
All as per serial item No 34.00 above but 30 KVA DG Set.

1

-

-

... More
All as per serial item No 34.00 above but 45 KVA DG Set.

1

-

-

... More
All as per serial item No 34.00 above but 62.5 KVA DG Set.

1

-

-

... More
All as per serial item No 34.00 above but 100 KVA DG Set.

1

-

-

... More
All as per serial item No 34.00 above but 125 KVA DG Set.

1

-

-

... More
Supply and fix in repair automatic battery charger of input 170V to 300V AC and output voltage 12V DC with features automatic selection of FLOAT and BOOST mode complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 35 above but of output voltage 24V, DC complete all as specified and directed.

5

-

-

... More
Taking down carefully aluminium /GI strip of any size and type from site complete, all as specified and directed.

2250

-

-

... More
Material and labour for fixing in replacement of aluminum strip of size 25 x 3.15 mm with saddles from above test point to Air Termination rods inter connections including brazing for joints copper/brass nuts , bolts /washers with insulators for necessary fixing on wall/laid on roof conductors and down conductors above ground complete all as specified and directed .

1750

-

-

... More
Material and labour for fixing in replacement of galvanised iron strip of size 32 x 6 mm for earth continuity from test point to aluminium conductors above for inter connections including brazing for joints copper/brass nuts, bolys/ washers with insulators for necessary fixing on wall/trenches etc complete, all as specified and directed.

500

-

-

... More
Material and labour for fixing in replacement of Air termination, single pointed aluminum rod 12 mm dia and 300 mm long laying at proper distance as per direction of Engr-in-Charge incl all cutting /welding complete, all as specified and directed.

60

-

-

... More
Material and labour for fixing in replacement of test point terminal block made of gun metal or phosphorous bronze of size 75x 75x75 mm drilled and screwed incl 3 Nos 8 mm dia head screw complete, all as specified and directed.

45

-

-

... More
Dismantling of Solar Water Heating system Collector or tube type and Suppy & Fixing new, evacuated tube type panel set of 500 LPD to 1000 LPD capacity complete with side holder necessary modification to the bracket frame/ inlet/ outlet connection of water incl connected accessories complete all as specified and directed.

45

-

-

... More
All as per Srl Item No. 42.00 above but of 250 LPD to 500 LPD capacity complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply and fixing in repair hot water pipe line upto 25mm dia (heavy grade) duly insulated with glass wool/ any other heat insulating material not less that 50mm thick layer including and aluminium cladding by 1.5 mm thick sheet, over the insulation firmly locked in perfect round shape complete all as per specified and directed.

100

-

-

... More
Supply and fixing in replacement Heating Element capacity 3.0KW (as per existing sample) ISI Marked round/ tringular base, push type or thread type including rubber washer suitable for Solar water heater of capacity 250 Ltrs to 1000 Lts capacity including taking down unserviceable complete all as specified and as directed.

25

-

-

... More
Supply and fixing Thermostat ISI Marked, (as per existing sample) suitable for Solar water heater of cap 250 Ltrs to 1000 Lts capacity including taking down unserviceable complete all as specified and as directed.

20

-

-

... More
Material and labour for repairing of tank leakage with suitable soldering of Solar water heater (any make) of capacity 500 Ltrs to 1000 Ltrs in situ by Authorised dealer and of existing company with testing after repairs upto delivery point of water, incl all connected accessories complete and taking down/ opened/ replaced the parts complete all as specified and directed by Engr-in-Charge. Note for Item No 42.00 to 48.00 :- (i) Make of Spares/ Servicing/ replacement of parts will be carried out by Auth service agency of existing make of Solar Water Heater).

6

-

-

... More
All as per Srl Item No. 47.00 above but for capacity upto 500 Ltrs complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repairs hot water tank of capacity 500 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repairs hot water tank of capacity 1000 ltrs, SS 304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement of digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement all as specified and directed by Engr-in-charge

4

-

-

... More
Supply and fixing astronomical timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB power contactor and 230V digital time switch for controlling LED/SV etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35 mm x 35 mm x 4 mm thick angle iron supports of not less than each 0.6 m height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement complete all as specified and directed.

2

-

-

... More
Supply and fixing the following spares for street lights of approved make as per existing make at site for in replacement :-

-

-

-

... More
Electronic driver suitable for 40/ 45 / 48 / 50/ 60 watts LED Roadway light/Flood light/post top light fittings. Make of the driver should be as per the Existing manufacturer all as specified and directed.

35

-

-

... More
Electronic driver suitable for 200 watts LED Flood light fittings. Make of the driver should be as per the Existing manufacturer all as specified and directed.

7

-

-

... More
Comprehensive maintenance of LED Solar Street light fitting of any make any model fitted on the pole at any height with any type of fixing arrangement by checking all connections, replacing the drivers/ Controller, surge protection device, control wiring copper wire and lugs, battery, solar PV modules all as directed by Engineer in charge. Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing it to the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper direction to the satisfaction of Engineer in charge) Spares under Comprehensive Maint should be measured and paid seperately complete all as specified and directed Notes:- (i) T&P including ladder for repair works shall be arranged by the contractor at his own cost. (ii) Spare parts required to be replaced under comprehensive maintenance shall be measured & paid separately under respective items of BOQ. (iii) Repair team for the street lights shall be available all the time to carry out maintanance works.

30

-

-

... More
Supply and fixing the following spares for Solar street lights of make as per existing at site for the following in replacement :-

-

-

-

... More
Supply and fixing Electronic driver suitable for Solar LED street lights upto 40 watts capacity. Make of the driver should be as per the existing manufacturer all as specified and directed.

5

-

-

... More
Supply and fixing Battery suitable for Solar LED street light of 40 watts capacity of existing make and model fixed on pole with all fixing arrangements complete all as specified and directed.

7

-

-

... More
Supply & Fixing charge controller/ smart solar street light controller for existing Solar LED street light complete all as specified and directed.

5

-

-

... More
Supply & Fixing LED light suitable for upto 40W solar light including wiring complete all as specified and directed.

5

-

-

... More
Supply and fixing, testing & commissioning in replacement of all in one standard 40W LED solar street light compact design consisting of 12V maintenance free battery of Min 02 days backup, PIR sensor and suitable size mono crystalline SPV module with visual indication of charging ON and battery low, mounted with all the standard fitting on existing LT pole complete all as specified & directed by Engr-In-Charge.

5

-

-

... More
Supply and fixing in replacement of 70/80 watts flood light Warm white/ coolday light in colour as per rquirement,  LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase,  etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing in replacement 7.5 HP 3 Phase Horizontal Openwell Submersible Pump, Voltage 415 V, Frequency 50Hz, Material Stainless Steel, Dimension- Suction x Delivery (mm): 80x65 mm, Power Rating: 5.5 kW, Speed (RPM): 2800, Flow Rate Not less than 20 LPS & Head Not less than 18m to be fixed in supply pipe line with all fittings and fixtures as per site requirements and making electric connections with necessary cabling, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and fixing in replacement of Special PVC Insulated & PVC Sheathed Industrial 6 Sqmm 3 Core Flat Submersible Cables with Bare Bunched Copper Conductor for Submersible Pump Motors with Voltage Grade 1100 Volts conforming to IS 694/1990, complete all as specified and directed by Engr-in-charge.

240

-

-

... More
Supply and fixing in replacement of Direct on Line Starter suitable for Submersible Pump Rated Power 7.5 HP, Rated Voltage: 415 V, Power: 5.60 kW, Three Phase, Relay Range-13.2-20 A, Controller Contactor rating - 20 A Max, Operational Current (A) 14.27 A, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Material and labour for Repair/Replacement of SITC of isolation transformer including main power board and control card complete set suitable for 10KVA online UPS complete as specified and directed by Engineer in charge.

1

-

-

... More
Material and labour for Repair/Replacement of SITC Transistors suitable for 10 KVA online UPS complete all as specified and directed by Engineer in charge.

1

-

-

... More
Material and labour for Repair/Replacement of RGBTs suitable for 10 KVA online UPS complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Material and labour for Repair/Replacement of PCB board suitable for 10 KVA online UPS complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Repair and maintenance of AMF panel of any capacity DG set of any make including routine /preventive maintenance checks for trouble free functioning as required :- (a) Checking all electrical connections & rectification (b) Checking all contact point/ Busbar & rectification (c) Checking auto/manual function (d) Cleaning the panel. Complete all as specified and directed by Engr-In-Charge.

3

-

-

... More
Repair /replacement of PCB board of DG Set of any capacity as per existing make and model complete all as specified as directed

3

-

-

... More
Taking out existing unsv GM single headed fire hydrant valve of 63 mm dia Flanged Inlet, supply & fixing GM single headed fire hydrant valve of size 63mm dia confirming to IS-5290 with ISI marked including gaskets, nuts, bolts, Brass Spindle Controlled Female Instantaneous Outlet Type. G.M. Coupling, Blank Cap, Chain, Twist Release Type Lug & all Accessories complete all as specified and directed.

2

-

-

... More
Material and labour for servicing/maintenance of Refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, stains complete, checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit for Make of Refrigerator -Samsung/LG/Bluestar/Whirlpool. Note: (i) Spares required for replacement on minor repairs as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items required for major repairs shall be measured and paid as Material and labour under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item.

6

-

-

... More
Supply only following company recommended spares as per original standard for refrigerators of any cap after dismantling/ taking out unsv one for the the following makes of refrigerator - Samsung/LG/Bluestar whichever applicable.

-

-

-

... More
Starting relay of suitable capacity as per existing make & model.

4

-

-

... More
Thermostat of suitable capacity as per existing make & model.

4

-

-

... More
Bottle support as per existing make & model

1

-

-

... More
Chiller trays small as per existing make & model

4

-

-

... More
Sliding trays large as per existing make & model

1

-

-

... More
Supply & fix new company sealed reciprocating compressor unit for refrigerator for Make - Samsung/LG/Bluestar whichever applicable of capacity 190 ltr to 321 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismantling/taking out existing unserviceable/burnt compressor unit from the refrigerator in wksp and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Compressor unit shall be of 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warranty certificate shall be submitted to dept.

4

-

-

... More
Material and labour for servicing/maintenance of Deep Freezer of capacity 200L/310L of Make-Blue Star/LG /Voltas in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note: (i) Spares require for replacement on minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items require for major repair shall be measured and paid as Material and labour under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item.

7

-

-

... More
Over load protector

5

-

-

... More
Starting relay of suitable capacity as per existing make & model.

5

-

-

... More
Thermostat of suitable capacity as per existing make & model.

5

-

-

... More
Running capacitor 4 to 25 mfd

6

-

-

... More
Sliding trays small as per existing make & model

3

-

-

... More
Sliding trays large as per existing make & model

3

-

-

... More
PVC fan for blower motor

3

-

-

... More
Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A, replacement of capilary tube and oil filter after dismantling/taking out existing unserviceable/burnt compressor unit from the Deep freezer 200/310 capacity and and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF of Make-Blue Star/LG /Voltas whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of DF. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warantee certificate shall be submitted to dept.

4

-

-

... More
Material and labour for refrigerant gas charging for Deep freezer with R-134A/ R-290/ 290-A/ as per existing gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 200/310L deep freezer Unit.

4

-

-

... More
Material and labour for refrigerant gas charging for Refrigerator with R-134A/ R-600A/ as per existing gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 190 L to 321 L Refrigerator Unit.

5

-

-

... More
Servicing of window/ split type ACs 1.5/2.0 TR capacity any make including cleaning the condensing and evaporative coil with the help of descaling solution & water, greasing and oiling the blower motor and refixing the same in position after servicing complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Material and labour in replacement of starting relay suitable for 1.5/2.0 TR capacity window/ split type AC including connections all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Material and labour in replacement of starting capacitor 80-100 mfd suitable for 1.5/2.0 TR window/ split type AC all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Material and labour in replacement of Air Filter pad suitable for window type AC 1.5/2.0 TR capacity all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Material and labour in replacement overload protector suitable for 1.5/2.0 TR window/ split type AC including connections all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Material and labour in replacement of running capacitor 36/ 45 mfd suitable for 1.5/2.0 TR capacity window/ split type AC all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Material and labour in replacement of selector switch/ Knob suitable for window type AC 1.5/2.0 TR capacity all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Material and labour for disconnecting and taking down of blower motor suitable for window type AC 1.5/2.0 TR capacity , rewinding with super enameled copper including wire as existing gauge including replacement of bushes and refixing the same complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
All as per Srl item No 82.00 above but suitable for 1.5/2.0 TR capacity spilt type AC complete all as specified and directed.

3

-

-

... More
Supply and charging of refrigerant as per existing refrigerant type (R-32/R-410A) in window/ split type AC 1.5/2.0 TR capacity including cleaning the gas system with anticorrosive solution and charging the refrigerant with anti most substances, strainer and rectification of leakage and replacement of filter and copper capillary complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Dismantling of old unserviceable sealed compressor of 1.5/2.0 TR capacity window type AC and Supply and fixing new sealed compressor including soldering of copper pipe, cleaning the refrigerant system, rectification of leakage, charging of refrigerant, rubber pads for foundation, nut & bolts etc and Testing the compressor all as specified and directed by Engineer-in-Charge.

5

-

-

... More
All as per Srl item No. 85.00 above but suitable for 1.5/2.0 TR capacity split type AC complete all as specified and directed.

5

-

-

... More
Supply and fixing Refrigerator of capacity 215 Ltrs, 5 star rating energy efficient, Direct - cool, digital inverter technology, single door refrigerator, toughened glass shelves, stabilizer free operation complete fixed in replacement of old unsv incl taking down unsv refrigerator from site and depositing it to MES store all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fixing Deep Freezer of capacity 215 Ltrs, energy efficient operation, D-cool technology, 2-in-1 convertible technology, single door hard top standard deep freezer, complete fixed in replacement of old unsv incl taking down unsv refrigerator from site and depositing it to MES store all as specified and directed by Engr-in-Charge.

4

-

-

... More
Material and labour for Painting of bottom tray of window type AC of any capacity with black Japan anti Corrosive paint inside and outside complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Material and labour for Writing MES No/SM No/Make/Srl Nos on window type ACs/Water Coolers/refrigerators/ Deep freezers with white synthetic enamel paint, size of the letter shall be of 2inches in height complete all as specified and directed.

3

-

-

... More
Opening the cover of automatic voltage stabilizer of any make and capacity, checking carefully, cleaning, servicing including tightening of loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete. Note -: All components need to be replaced, price shall be included in the quoted rate.

4

-

-

... More
Amount of credit of Rs. 112671.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.