Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date7 Nov 2024
Closing Date28 Nov 2024
Tender Amount₹ 20,25,000
Costs
EMD
₹ 40,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682755_1Tender No
CWE/Y-78/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
3
-
-
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
590
-
-
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed.
90
-
-
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
182
-
-
Taking down steel water tubing 15 mm bore including all fitting and connections complete all as specified and directed.
80
-
-
Taking down steel water tubing 20 mm bore including all fitting and connections complete all as specified and directed.
80
-
-
Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed.
24
-
-
Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed.
18
-
-
Dismantling timber in scantling 40 sqcm and over in section, framed work complete all as specified and directed.
0.5
-
-
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
85
-
-
Dismantling water tanks of capacity exceeding 250 Litres but not exceeding 500 Litres, complete all as specified and directed.
4
-
-
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed.
18.36
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
11.57
-
-
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
6.79
-
-
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
1.5
-
-
PCC 1:3:6 (nominal mix) type C-1 (using 20mm graded crushed stone aggregates) as in filling concrete for holdfast complete all as specified and directed.
0.7
-
-
PCC 1:2:4( nominal mix) type B-2 (using 40mm graded crushed stone aggregates) as in surface channel and drain all as specified and directed.
1
-
-
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
0.25
-
-
Pre-cast cement concrete , type C-1, 1:3:6 , using 20mm graded crushed stone aggregate block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified.
1.5
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex tra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed.
30
-
-
RCC Type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
0.5
-
-
Use & waste of form work to suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of flat concrete, complete all as specified & directed.
8
-
-
Use & waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work not exc 10cm wide for rough finished surfaces of concrete, complete all as specified & directed.
20
-
-
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified.
24
-
-
2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
0.3
-
-
35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
11.76
-
-
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
38.4
-
-
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed.
12.8
-
-
35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed.
11.76
-
-
Aluminium powder coated three track sliding windows (with three sliding shutters, (One with stainless steel wire gauge 0.36mm nominal dia of wire and average width of aperture 1.40mm and two with tinted glass panes 4mm thick) aluminium sections not less than 1.1kg per meter for bottom track and top track and side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides, 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading channel gasket, nylon rollers Maruthi lock with handles etc complete all as specified and directed
20
-
-
Aluminium ventilators powder coated with 4mm thick frosted glass louvers and incl 0.36mm dia and 1.18mm aperture stainless steel jally (Fixed outside of ventilator) all as specified and directed.
3
-
-
Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed.
40
-
-
Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed.
40
-
-
Mild steel butt hinges of size 100mm medium weight cold rolled complete all as specified and directed.
36
-
-
250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
12
-
-
300mm, Mild Steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
2
-
-
100mm size, Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
8
-
-
Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified.
60
-
-
18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, complete all as specified.
32
-
-
Aluminium anodised snap grid frame work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 25mmX25mmX1.50 mm as main runner, aluminium tee of size 25mmX25mmX1.25 mm as cross runner and aluminium angle of size 25mmX25mmX1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including perforated particle board/tile 12mm thick for insulation and acoustic purpose as in ceiling flat or sloping 60cmx60cm in size including necessary scaffolding all as specified and directed.
85
-
-
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
170
-
-
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
12
-
-
Rolled Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde- E-250) quality-A complete all as specified and directed.
40
-
-
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed.
200
-
-
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars including cutting, drilling, welding etc confirming to Fe-290 Gde E-165 all as specified and directed.
90
-
-
Mild steel work as in hold fast, wind ties for roof including securing bolts including all necessary drilling ,bolting or reverting etc and all similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
15
-
-
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
50
-
-
40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in levelling course, surface finished even and rough to receive top finish complete all as specified and directed.
30
-
-
Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
31.5
-
-
Chequered cement concrete coloured tiles, homogenious texture glossy finished , chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 20 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the AGE(I).
27
-
-
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match after roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
150
-
-
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
30
-
-
20mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed.
8
-
-
Cutting, rubbing/grinding & mirror finish ,rounding of edges of marble/ kota stone/ granite stone complete all as specified and directed.
10
-
-
Glazed ceramic coloured tiles of size 350x 250x 7 mm/ 450X 350X 7mm mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
90
-
-
Rendering cement plaster 10mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
270
-
-
Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
320
-
-
Rendering cement plaster 5mm thick in cement mortar 1:3 on fair faces of brick or on concrete surfaces, as in ceiling , surface finished even and smooth without using extra cement, all as specified.
100
-
-
Supply only integral water proofing compound, complte all as specified.
15
-
-
Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
60
-
-
Preparation of old steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
30
-
-
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats exterior emulsion weather coat paint paint over one coat of primer over and including a coat of 2 mm thick wall care putty complete, complete all as specified and directed.
320
-
-
Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
50
-
-
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over and including a coat of 2 mm thick wall care putty complete, all as specified and as directed by Engr-in-Charge
270
-
-
Preparation of new plastered surfaces or un plastered, previously undecorated ceiling surfaces and applying three coats of white wash, complete all as specified and directed.
100
-
-
Preparation of old surfaces of wall by Complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
100
-
-
Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including , 15mm bore cast copper alloy, with capstan heads, chromium plated, fancy type mixer, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx
4
-
-
Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore, fixed in repair, complete all as specified and directed.
12
-
-
Stop valve cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20mm bore iron pipe or for unions and fixed in repairs complete, all as specified.
4
-
-
Stop valve/Angle Valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified.
20
-
-
Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, fixed in repair, complete all as specified and directed.
12
-
-
PVC connections 15 mm size with PTMT nuts of length 450mm fixed in repair complete all as specified and directed.
20
-
-
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified
8
-
-
Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union. fixed in repair complete all as specified.
4
-
-
600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers.
4
-
-
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, fixed in repair, all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx .
4
-
-
Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc, fixed in repair all as specified. Make: Cat Part No. 2071 of 'Cera' or equivalent makes mentioned in Appx.
4
-
-
Sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified.
4
-
-
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
60
-
-
All as per item no 82 above but exept pipe
20
-
-
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
60
-
-
All as per item no 84 above but exept pipe
20
-
-
75 mm dia, Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
10
-
-
100mm dia, Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
10
-
-
75mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls, fixed in repair complete all as specified and directed.
25
-
-
100mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls, fixed in repair complete all as specified and directed.
30
-
-
Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified.
4
-
-
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
111
-
-
Point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size(two run with colour code RYB) for one light point ,fan point, exhaust fan point,or bell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green)multistrand PVC concealed conduit of approved size and quality ISI marked,including all other required accessories as specified in preamable 1(a) to (q) of section 19 of SSR Part-II under heading 'point wiring' fixedon wall/ceiling including sunk cast iron terminal boxes grouting/flushing on wall for mounting fittings like switch,sockets etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/Stone masonary wall complete including cutting,chasing,pinning and making good the disturbed surface by using cement mortar 1:3 complete all as specified and directed by Engr-in-charge.,(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete).
62
-
-
All as per serial item No '92' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
16
-
-
All as per serial item No '92' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
16
-
-
All as per serial item No '92' above, but for one light point controlled by two way switch all as specified and directed.
1
-
-
All as per serial item No. '92' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
16
-
-
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
90
-
-
Switch piano flush type, single pole, one way, 16 Amps, all as specified.
16
-
-
Bell push, flush type, 5 amp all as specified.
4
-
-
Socket outlet, 3pin, , 6 amps flush type, all as specified.
32
-
-
Switch piano flush type, single pole, two way, 5 Amps, all as specified and directed.
2
-
-
Socket outlet two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified.
16
-
-
Bell, AC, 230 volts, single pole all as specified.
4
-
-
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
40
-
-
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, all as specified.
12
-
-
LED Lamp, 10 Watt, LED Adore Plus E27 CDL 2 STAR LAMP, Complete all as specified.
Make: Havells cat part No. LHLDDDHBIA5R010 or equivalent in Appx
12
-
-
Renewal of sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
1
-
-
Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
4
-
-
Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
1
-
-
MCB TPN, 63 Amp, 415 Volts, 10 KA all as specified.
1
-
-
MCB SPN 40 Amp, 240 Volts, B Curve , 10 KA all as specified.
5
-
-
MCB SP 6 to 32 Amp, 240 Volts, B Curve , 10 KA all as specified.
38
-
-
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
73
-
-
Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental
friendly, energy efficient ready to use pack , 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havell's Cat Part No. LHEXACP7IN1W010 of "Havells" or equivalent in makes mentioned in Appendix
12
-
-
Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental
friendly, energy efficient ready to use pack. 1x20W, 6500K ,230V, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havells cat part No. LHEXAWP7IN1W020 or equivalent in Appx
28
-
-
35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket made up og 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified
Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx
6
-
-
Disconnecting and taking down of Geysers (water heater) of capacity 25/50 Ltrs horizontal/vertical of any make/model from existing position and dismantling of parts i.e.bottom plate, Top cover, water assembly, thermostate, heating elements, inner tank ,glass wool,Pressure release valve, inlet and outlet valves etc.complete and reassembling and refixing in same position after descaling desludging and cleaning with suitable chemicals and materials and washing with fresh water and repair and replacment of defective/unserviceable components and refixing to the existing position by means of anchor bolt,PVC connection,replacement of plug Top,connection lead wire,indicator,thermostat,heating element,inner tank,outer cover(whatever is required at site) complete all as spaciifed and directed.
4
-
-
Factory made sheet metal enclosure dust and vermin proof made out of 2.00mm thick MS sheet of size 90x60x20cm depth with double door hinged shutter and
locking arrangement for fixing only suitable arrangement for TPN 4 way DBs -01 No and KWH meter-04 Nos with PVC transparent sheet suitable for visibility of meter reading with complete connection of meter and DB outlet MCB with 6 sqmm single core PVC wire complete of meter and DB outlet MCB with 6Sqmm single core PVC wire complete wiring should be fixed/ covered proper tie and PVC casing cover flushed/ semi flushed/ grouting on wall surface complete all as directed (Note : Unit rate shall be inclusive of making good the area not exceeding 0.6sqm and not exceeding 0.125 m depth for filing the hollow existing surface with half bricks in CM (1:4) all as specified and directed by Engr-in-Charge.
1
-
-
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
12
-
-
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
5.51
-
-
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
591
-
-
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
85
-
-
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm, 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
75
-
-
Aluminum strip 25x3.15mm fixed with porcelain/PVC saddles and fixing screws etc including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapir , complete all as specified.
42
-
-
Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified.
4
-
-
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw all as specified.
2
-
-
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
2
-
-
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
2
-
-
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 29 of tender doucments.
-
-
-82321
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%