Military Engineer Services Tender

... More
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 Jan 2025
Closing Date17 Mar 2025
Tender Amount₹ 1,95,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:4 , complete all as specified and directed.

6.09

-

-

... More
Hardcore of broken builders or stones guage not exceeding 63mm, desposited, spread and levelled in layers not exceding 15cm thick, watered and rammed to a true surface complete all specified and directed.

78.68

-

-

... More
75mm thick PCC 1:4:8, type D-2 (using 40mm graded aggregates) as in sub base complete all as specified and directed.

637

-

-

... More
25 mm thick plain cement concrete, 1:2:4, type B-1 (using 20mm graded aggregates) in sub base for receving floor tiles and mass concrete complete all as specified and directed.

25

-

-

... More
Joint free non skid ceramic coloured tiles 7 to 8 mm thick and area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in Skirting (vertical Surface/walls) set and jointed in neat cement slurry and pointed in coloured cement to match the finish over 15mm thick screed bed in CM (1:4) and removing debries/tiles out of the premises etc complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
Rendering 15 mm thick on fair faces of brick surfaces in cement mortar (1:4), finished even and smooth without using extra cement, complete all as specified and directed.

18

-

-

... More
Preparation of newly plastered external surfaces of wall and applying two or more coats of 100% weather proof premium acrylic emulsion paint having VOC less than 50 gm/litre and UVre sistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/ weather coat) without any brush marks on the surface in any colour over including necessary scaffolding up to three stories height of buildings, complete all as specified and directed by Engineer-in-Charge. NOTE:- Shade/colour shall be approved by GE and all painted areas site to be cleaned and shall be handed over at the earliest without any extra cost to Govt.

100

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm, in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.

20.54

-

-

... More
Removing excavated material to a distance exceeding 1.5 Km but not exceeding 5.00 Km and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed Engineer-in-Charge.

12.44

-

-

... More
Providing and fixing Powder coated anodised aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as per architectural drawings and as directed by Engineer-in-Charge.

80

-

-

... More
Toughned glass 10mm thick in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and solar control film 50 micron thick reflective type sticked to glass panes as per instructions of manufacturer's complete all as specified and directed Engineer-in-Charge.

42

-

-

... More
Earth work in excavation over areas in any type of soil by mechanical means (Hydraulic excavator) (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed by Engineer-in-Charge.

2437.5

-

-

... More
Rolling & consolidating of formation surfaces in cutting/filling of helipad with 8 to 12 tonnes power roller and forming required gradient and camber including watering complete all as specified and directed Engineer-in-Charge.

375

-

-

... More
Laying and compacting 300mm (compacted thickness) granular sub base course (GSB) Grade V in a 2 layer of 150 mm each as per table 400-1 & 900-1 of MORTH & H spacifications for road & bridge work over compacted sub grade with stone aggregates by using motor grader, spreading. levelling and rolling with vibratory roller of capacity 80-100KN static wt and consolidating to reqd gradient and camber complete all as specified and directed Engineer-in-Charge.

375

-

-

... More
Prepaning of granular sub base course surface by brushing with wire brushes for removing mud etc, sweeping with brooms and finally the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and as directed Engineer-in-Charge.

375

-

-

... More
150mm thick (compacted thickness) wet mixed macadam (WMM) laid in two layers of 75mm each grading as per table 400-13 of MoRTH specification for road and buildings works 2013, manufactured in WMM plant with clean, crushed, graded stone aggregates of specified grading and granular material premixed with water to a dense mass, spreading using sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight consolidated to required gradient and camber complete all as specified and directed by Engineer-in-Charge. NOTE :The finished surface tolerances shall be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013.

375

-

-

... More
Dry lean concrete (DLC) 150mm thick having compressive strength not less than 7 Mpa at 07 days for each consecutive group of 05 cubes. Individual strength of each cube must not be less than 5.5 Mpa at 07 days . DLC laid over prepared and laid WMM with coarse and fine aggregates conforming to IS-383, size of aggregates not exceeding 26.5 mm grading and other parameters as per table 900-1 MORTH & H specification for road and bridge works/table -1 IRC :SP: 49-2014 . Minimum cement content must not be less than 140 kg/cum mixed in batching plant, transported to site and laid by sensor paver including spreading and compacting using double drum smooth wheeled rollers with 80-100 KN of static and vibratory capacity including necessary formwork, finishing etc complete all as specified and directed by Egineer-in-Charge

375

-

-

... More
10 mm thick sand cushion with clean river sand duly clear of residual , organic and deleterious materials spread evenly to uniform thickness laid over DLC layer as specified and directed Engineer-in-Charge. NOTE:- No additional amount to be paid for overlap.

3750

-

-

... More
400 Micron Thick HDPE Sheet (Virgin Quality) water proof, wrinkle free without puncture having minimum weight 390 gms/Sqm over sand cushion as specified in the design as specified in the specification with overlap between adjacent strips and at transverse joints as minimum 300mm complete all as specified and directed Engineer-in-Charge.

3750

-

-

... More
225mm thick Pavement Quality Concrete (PQC) of minimum 28 days field flexural strength of 45 kg/sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15-2017, coarse aggregate of clean, hard strong, dense, non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed sand stone combination of both using minimum 360 kg/cum of cement with non-circular, vergin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 2400 C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufaturer, PQC laid, spread and compacted with slip-form paver of minimum 7.5m width, including curing and tining by Texturing cum Curing Machine complete all as specified and directed by Engineer-in-Charge. Required surface texturing to be done as specified in clause 10.1.14 and Table 9 of IC 15-2017.

843.75

-

-

... More
Forming 25x55mm expansion joint in concrete slab for full depth of PQC. Early entry saw and subsequent cutting by using diamond bit cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall made dry, vaccum cleaned and free from dirt, oil, vegitation and other debrie. The joint then filled with pre-molded 25mm thick compressible polyurethane closed cell type filler board as specified, thereafter application of two coats of primer with thin brush by forward and backward movement at an inteval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polytheylene foam backup rod of 30mm dia, over filler board and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 year performance guarantee, applying masked tape on edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed.

17.5

-

-

... More
Forming dummy/contraction joint using diamond cutter with an initial saw cut of 3mm soon after the concrete has set,upto a depth of 1/3rd to 1/4th the thickness of the slab,widening the first saw cut to 8mm and 24 mm deep by using diamond bit cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vaccum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 10 mm dia, application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum MAF + 30% having 10 year performance guarantee, applying masked tape on the edges of joints and removing the masking tap after filling of sealant and specified and as per the method specified by the manufacturer,complete as specified and directed.

35

-

-

... More
Cutting of construction joints 25 mm deep and 8 mm wide by early entry saw cut using diamond bit cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vaccum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 10mm dia, application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum (MAF) of + 30% having minimum 10 year performance guranttee applying masked tape on the edges joints and removing the masking tap after filling of sealant and specified and as per the method specified by the manufacturer,complete as specified and directed.

140

-

-

... More
Preparation new concrete surfaces of runway and painting lines, dashes, arrows, letters, etc. on roads, pavements in adequate No of coat and the like exceeding 10cm wide with road marking paint, white or golden yellow, complete as specified and directed.

150

-

-

... More
Surface Dressing in soft/loose soil for Helipad Ground shoulder not exceeding 15 cm deep of 3.00 mtr from the edge of Helipad complete all as specified and directed.

786

-

-

... More
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and directed.

612

-

-

... More
25 mm thick Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.

15.3

-

-

... More
Machine pressed precast concrete interlocking paver block rubber moulded any shape and size with grey cement and no pigment conforming to IS15658-2006 of 80mm thickness M-40 Grade complete all as specifed and directed by Engineer-in-Charge.

612

-

-

... More
Providing precast cement concrete, 1:2:4, type B-1 (using 20mm graded aggregates) as in kerb stone, fair faces, including chamfers, weatherings, throating etc. and setting in CM 1:4 complete all as specified and directed.

26.69

-

-

... More
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.

91.8

-

-

... More
110mm bore PVC pipe (SWR) in any length with rubber ring joints, as in weep holes complete all as specified and directed.

14

-

-

... More
Excavation in post holes each not exceeding 50 cum, getting out in soft/loose soil and removing surplus material not exceeding 50 mtr and making good disturbed surfaces complete all as specified and directed.

260

-

-

... More
PCC 1:3:6 type C-2 (using 40mm graded aggregates) as in foundation, filling and mass concrete of posts and struts complete all as specified and directed.

110.63

-

-

... More
ISA 75 x 75 x 10mm as in posts and struts in fencing & 40x6 mm flat iron including cutting tops to shape as directed , drilling holes notching for wire etc, conforming to Fe-290 Gde E-165 complete all as specified and directed.

11198.4

-

-

... More
Two coats of synthetic enamel paint over red oxide primer on new steel surfaces including preparation of surfaces complete all as specified and directed.

272.4

-

-

... More
10mm dia 40mm long MS screw bolt machine made with hexagonal or Square head at one end and screwed the other, screwed end fixed with washer complete all as specified and directed.

69.63

-

-

... More
10mm dia MS round bar for fixing of chain link fencing with post. Fe-410-W(Gde.E-250) quality-A or Fe 290(Gde-E-165) complete all as specified and directed by Engineer-in-Charge.

1851

-

-

... More
Supply only chain link fencing, galvanized mild steel of mesh 100x100mm size,10 gauge complete all as specified and directed by Engineer-in-Charge.

2016

-

-

... More
Fixing only chain link fencing, including line wires 100x100 mesh, 10 gauge galvanized mild steel to any type of standards, rails, straining bolts, etc. complete all as specified and directed by Engineer-in-Charge.

1440

-

-

... More
Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.

2.4

-

-

... More
Reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.

2.56

-

-

... More
Rendering 5mm thick on fair faces of brick work or concrete surfaces in cement and sand mortar (1:3) thick and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.

19.5

-

-

... More
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.

291.44

-

-

... More
TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.

39.72

-

-

... More
TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.

79.34

-

-

... More
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.

6.24

-

-

... More
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.

31.56

-

-

... More
Two coats of cement based paints including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.

19.5

-

-

... More
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-Charge.

1154.76

-

-

... More
Two coats of synethetic enamel paint over red oxide primer including preparation of new steel surfaces complete all as specified and directed by Engineer-in-Charge.

29.2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.