Directorate Of Urban Local Bodies Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Directorate Of Urban Local Bodies - DULB Tender

Works
Eprocure
Opening Date24 May 2018
Closing Date5 Jun 2018
Tender Amount₹ 1,96,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc, excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects.(For work upto 1.5 metres below ground level). + (a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (10.90+10.95a)

267

-

4257

... More
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. + (a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (10.86+10.95a)

97

-

6538.12

... More
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position complete in all respects. + (a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (10.82+10.95a)

295

-

5966.4

... More
First class brickwork laid in cement sand mortar 1:6 in foundation and plinth. (11.2)

20

-

2972.2

... More
First class brickwork laid in cement sand mortar 1:4 in first storey upto 4 meters above plinth level.(11.9)

368

-

2901.15

... More
11.43 cm thick brick wall with every fourth course, reinforced with hoop-iron, laid in 1:4 cement sand mortar in super-structure (11.46)

257

-

439.95

... More
Extra for additional storey upto 4 metres above the top of structural roof of lower storey (11.41)

53

-

57.75

... More
Terracing consisting of 19 mm thick heat resistant tiles for roof insulation,300mmx300mm laid on 20 mm thick1:3 cement coarse sand mortar including grouting with neat white cementover average 75 mm thickscreed of1:8:16 including two coasts of bitumen laid hot at 1.65 Kg per sqm on top of R.C.C. slab and cleaning of top surface complete.the tile shall be made of white cement blended with fibrous polymershaving flextural stress value of _ 150 kg/cm2 & thermalconductivity value _ 0.18 w/ m.k. (13.97)

331

-

1031

... More
Providing & fixing PVC Rain Water pipe 6kg. Pressure of ISI mark in cement morter during masonary work.100mm dia PVC pipe 6 kg. pressure (13.89b)

153

-

218.4

... More
Providing & fixing PVC Bend ISI Mark 100mm dia PVC Bend (13.90a)

86

-

116.88

... More
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (13.50)

13

-

41.82

... More
Cement concrete 1:2:4 gola 10cm X 10cm quadrant along junction of roof with parapet wall finished smooth, where specially specified.(13.64)

145

-

18.19

... More
Base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling.(14.1)

666

-

184.75

... More
Fixing Marble stone flooring 17mm thick & above slab including matching grains of marble laid in any pattern as specified over base of 12 mm thick cement coarse sand morar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing (excluding the cost of marble) (14.49) White marble White Makrana marble (Ist quality)

944

-

1486.18

... More
Kotah stone flooring minimum 25 mm thick in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing.(14.62)

732

-

706.82

... More
Extra for Kotah stone flooring in treads of steps not exceeding 30 cm in width. (14.64)

39

-

4.02

... More
Extra for nosing in treads of steps of Kotah stone slab. (14.65)

135

-

21.35

... More
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc.(14.66)

44

-

829.5

... More
12 mm thick cement plaster 1:6 (15.7)

2260

-

63.9

... More
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (15.12)

1440

-

78.6

... More
6 mm thick cement plaster 1:3(15.49)

2135

-

68.1

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or matallic or plastered or concrete surfaces to give an even shade. (16.3)

225

-

31.02

... More
Applying priming coat on steel work consisting of genuine red lead mixed with linseed oil and turpentine oil in equal proportions (16.10)

225

-

17.32

... More
White washing (16.48) Three coats

2196

-

4.12

... More
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (16.58)

2145

-

30.03

... More
P & L Birla Putty (16.81)

1395

-

41

... More
Cost of aluminium fittings complete for doors and windows, such as tower bolts,handles,etc., and screws for these fittings excluding sliding bolt (17.72)

246

-

71.2

... More
Providing and fixing sliding bolt with nuts and screws,etc.,complete (17.83) size 300 mm X 16 mm

14

-

176.6

... More
size 250 mm X 16 mm

32

-

161.2

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/apppropriate Z sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc.aluminium sections shall be smooth,rust free straight mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling C.P brass /stainless steel screws , all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately) Fixed portion (Anodised aluminium transparent or dyed to required shade according to IS;1868,minimum anodic coating of grade AC 15) (17.95+17.95a)

3362

-

278.64

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc.aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling C.P brass /stainless steel screws, etc. complete. Shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PBC/ neoprene gasket required including aluminium fitting i.e. aluminium kun (17.96)

1305

-

309

... More
Providing and fixing glazing in aluminium door, windows ,ventilator shutter and partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items). (17.98) With float glass panes of 5.00 mm thickness

55

-

805

... More
With float glass panes of 4.00 mm thickness

111

-

700.35

... More
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete .Pre-laminated particle board with decorative lamination on both sides.(17.97)

108

-

819.31

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS;6315 marked for doors including cost of cutting floors as required , embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box (a) With Stainless Steel cover plate. (b) With Brass cover plate. (17.99)

10

-

1757.7

... More
Providing and fixing six-levers brass 10 cm mortice latch and lock, and a pair of lever handles with necessary screws, etc., complete (Indian make of reputed firm, such as odrej or eauivalent) (17.73)

56

-

537.8

... More
Providing fixing aluminium round shape handle of outer dia 100mm with Ssscrews etc. complete. (17.102) Powder coated minimum thickness 50, micron aluminium

20

-

52.44

... More
Wrought iron and mild steel (using angles, flats, square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doorsopen able or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (18.12)

45

-

6242.1

... More
Stair case railing of 40 mm internal dia G.I. pipe class 'B' as per I.S. No. 1239 as hand rail using flats and square bars as supporting members and base plate welded as per design specified including cutting, welding rods and complete fixed in position (18.13)

2

-

6945.6

... More
Fe-500 E.Q.R. TMT Steel bars for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding and placing in position complete. (18.22)

788

-

5502.3

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (as approved by the Engineer-in-charge) EUROPEAN TYPE WATER CLOSET SUIT, SYPHONIC TYPE, consisting of- (i) VITREOUS CHINA WARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One Piece SEAT AND LIDIN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers,(to the approval of the Engineer-in-charge). COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. Double trap syphonic W.C. Suite White (30.5)

24

-

8615.2

... More
PROVIDING AND FIXING POSITION BEST INDIAN MAKE FLAT BACK OR ANGULAR PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE A RANGE OF THREE URINALS FLAT BACK OR ANGULAR LIPPED FRONT IN VITREOUS CHINA-WARE WITH 5 LITRES CAPACITY BEST INDIAN MAKE C.I. AUTOMATIC FLUSHING CISTERN WITH FITTINGS AND FLUSH PIPE ETC., COMPLETE AS FULLY 465mm high White(30.21)

5

-

3889.6

... More
EXTRA FOR PROVIDING AND FIXING STANDARD SIZE C.P.BRASS FLUSH PIPE COMPLETE WITH FITTINGS INSTEAD OF G.I.FLUSH PIPE COMPLETE. (i) For a range of three urinals (30.38)

5

-

1104.4

... More
Providing and fixing 25mm thick marble backs for the different type of urinals. Size 60 mm X 1050 mm (30.39)

15

-

950.4

... More
Providing and fixing 25mm thick marble partition for different type of urinals. Size 375 mm X 750 mm (30.40)

10

-

431.2

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (ORDINARY) LAVATORY SUITES consisting of Lavatory in VITREOUS CHINAWARE size as give below ( to the approval of the Engineerin- charge) including china plug for tap hole where necessary ; R.S. or C.I.BRACKETS for building into wall including painting; 32mm C.P.BRASS WASTE WITH C.P. brass chain and rubber plug; 15mm C.P.BRASS SCREW DOWN PILLAR TAP WITH jam nuts or couplings best design (as approved by the Engineer-in-charge) ALL FITTINGS BEST INDIAN MAKE and; to the approval of the Engineer-in-charge. ALL brass work chromium plated and COMPLETE in all respects INCLUDING cutting and MAKING GOOD THE WALLS, FLOORS AND PAINTING OF FITTINGS ETC. WHITE (i) Size 510mm X 400 mm with one no. tap (30.41)

28

-

1944.8

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE PAPER HOLDERS FIXED INTO wall with C.P. brass screws complete in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. brass (30.67)

24

-

121

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE TOWEL RAILS FIXED in with raw slugs embedded in walls with C.P. brass screws. Complete in all respect INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) 25 MM DIA C.P.BRASS ADJUSTABLE 600 mm long (30.68)

28

-

268.4

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE BEVELLED EDGE 5.5 MM THICK MIRROR mounted on ASBESTOS sheet GROUND FIXED IN POSITION BY MEANS OF 4 NOS. CHORMIUM PLATED BRASS SCREWS AND WASHERS over rubber washers and rawl plug embedded in the wall of chromium plated brass clamps with C.P. brass screws (as required by the Engineer-in-charge) COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) INDIAN MAKE (i) 600mm X 450mm (30.71)

28

-

470.8

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE COAT AND HAT HOOKS fixed into wall with C.P. brass screws and rawl plugs etc. COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P.CRASS (30.73) (i) One way

28

-

160.6

... More
(ii) Two way

10

-

189.2

... More
Providing and fixing in position super quality 65mm i/d opening C.P. brass dome type hinged grating weighing about 750gms, fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge) (30.74)

71

-

297

... More
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the engineer-in-charge). (30.75) (a) Bib cock long body

24

-

510.4

... More
(b) Bib cock

24

-

440

... More
Providing and fixing in position C.P. brass stop cocks (as approved by the Engineerin-charge) (a) 15 MM STOP COCK

56

-

444.4

... More
(i) Stop cock male and female end (30.76)

20

-

572

... More
PROVIDING AND FIXINGIN POSITION H.C.I.SOIL WASTE VENT OR ANTISYPHONAGE PIPES TO I.S.I. SPECIFIACTION OF E.L.C. MANUFACTURE OR OF ANY OTHER REPUTED FIRM INCLUDING CUTTING AND WASTAGE ETC. AND CUTTING HOLES IN WALLS, ROOFS OR FLOOR ETC.AND MAKING GOOD to its original condition BUT EXCLUDING COST OF LEAD JOINTING. (30.84) (a) 100 mm internal diameter

249

-

438.75

... More
(b) 75 mm internal diameter

210

-

373.5

... More
PROVIDING LEAD CAULKED JOINTS TO H.C.I.PIPES AND SPECIALS CONFORMING TO I.S.I.SPECIFICATION OF E.L.C.MANUFACTURE OR ANY OTHER REPUTED FIRM INCLUDING COST OF LEAD YARN, FUEL AND TOOLS ETC. (30.87) (a) 100 mm internal diameter (1.13 kg)

249

-

134

... More
(b) 75 mm internal diameter (0.91 kg)

280

-

110

... More
PROVIDING AND FIXINGIN POSITION M.S.OR HEAVY FLAT IRON CLAMPS made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. SOIL WASTE vent or anti pipes to walls COMPLETE IN ALL RESPECTS INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS ETC., AND PAINTING. (30.88) (a) For 100 mm internal diameter pipes

143

-

56.25

... More
(b) For 100 mm internal diameter pipes

121

-

49.5

... More
PROVIDING AND FIXING IN POSITION H.C.I.SPECIALS FOR SOIL, WASTE, VENTOR ANTI-SYPHONAGE PIPES TO I.S.I MARKED INCLUDING cutting and wastage etc., CUTTING HOLES IN WALLS ROOFS OR FLOORS ETC, AND MAKING GOOD to its original condition BUT EXCLUDING COST OF LEAD JOINTING (30.91) (a) FGR 100 MM I/D PIPES. 100 mm Bend plain Terminal guard

37

-

238.5

... More
(b) FOR 75 MM I/D PIPES

13

-

177.75

... More
Bend with door

71

-

189

... More
Terminal guard

11

-

112.5

... More
PROVIDING AND FIXINGIN POSITION H.C.I. FLOOR TRAPS I.S.I.MARKED OF THE SELF CLEANING DESIGN WITH C.P. BRASS HIGED GRATING WITH FRAME WITH OR WITHOUT VENT ARM AND INCLUDING CEMENT CONCRETE 1:2:4 under and around the floor trap where required upto floor level COMPLETE IN ALL RESPECTS INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS, ETC., minimum depth of water should be 150 mm with a minimum seal of 50 mm 75 mm inlet and 75 mm outlet (30.89)

88

-

462

... More
PROVIDING AND FIXING LEAD INLET CONNECTION WITH BRASS UNION FOR FLUSHING AND WARNING PIPES COMPLETE IN ALL RESPECTS. (a) 15 mm lead pipe 1.49 kg/metre thickness 2.7 mm(30.93)

56

-

92.4

... More
PROVIDING AND FIXINGIN POSITION GULLY TRAPS FIXED IN CEMENT CONCRETE 1:4:8 complete WITH H.C.I.GRATING 150 MM X 150 MM CAST IRON COVER WEIGHING APPROXIMATELY 7.26 K.G. AND FRAME CLEAR OPENING 300 MM x 300 MM and outside size 330 MM x 330 MM AND CHAMEBR INCLUDING cost of all brick work in CEMENT MORTAR 1:5 CEMENT CONCRETE 1:8:16 IN FOUNDATIONS, AND CEMENT CONCRETE 1:2:4 IN COPING around C.I. cover and frame etc. WITH THREE COATS of black bitumastic superior PAINT of approved manufacture on all C.I. work AS PER STANDARD DESIGN, minimum depth of water should be 150mm with a minimum seal 50mm. (a) 100 mm internal diameter S.W. gully trap (30.114)

13

-

747

... More
I/D INLET CP BRASS WITH REVOLVING POINT (30.66)

5

-

549

... More
LABOUR FOR LAYING JOINTING, FIXING AND TESTING G.I/P.V.C/W.I PIPE LINES AND SPECIALS tees bends, Sockets elbows etc., INSIDE BUILDING and testing etc., complete including cutting threading. (28.18) INCLUDING COST OF SPECIALS 15 mm dia pipe line

205

-

34.8

... More
20 mm dia pipe line

136

-

41.28

... More
25 mm dia pipe line

70

-

46.08

... More
32 mm dia pipe line

73

-

57.12

... More
FIXING SCREW DOWN STOP COCKS of gumetal or hard brass on G.I.pipelines laid in the ground or inside buildings INCLUDING CARTAGE from divisional stores or nearest railway station to site of works. The stop cocks will be supplied free of cost to the contractor ex-divisional stores or nearest railway station.(28.30) 25 mm internal diameter

10

-

10

... More
32 mm internal diameter

6

-

11.8

... More
PAINTING G.I.PIPES AND SPECIALS WITH 1ST AND 2ND QUALITY SYNTHETIC ENAMEL PAINT IN ALL SHADES ON EXISTING OR NEW WORK, TWO COATS PAINTS INCLUSING LEANING, RUBBING SURFACE, ETC(30.106) 15 mm and 20 mm i/d of pipes and specials

30

-

2.75

... More
25 mm and 32 mm i/d of pipes and specials

70

-

3.81

... More
CUTTING CHASE IN BRICK WALLS IN CEMENT OR IN FLOOR FOR EMBEDDING G.I.OR H.C.I.PIPE LINES AND MAKING GOOD THE SAME TO ITS ORIGINAL CONDITION Size 75 mm X 75 mm after housing G.I.Pipe etc.(30.95)

403

-

26.4

... More
P & F HDEP water storage tank of sintex diplat etc. (HSR 30.119) 5000 Ltr.(30.12)

3

-

25908

... More
Cement concrete 1 : 5 : 10 with brick ballast 40 mm Nominal size in foundation and plinth. (10.34)

44.28

-

1947.28

... More
Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in HSR item No. 29.38, 29.39, 29.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in- Charge(29.95) 100 mm diameter

26

-

134.4

... More
150 mm diameter

110

-

208.95

... More
CONSTRUCTION BRICK MASONRY INSPECTION CHAMBER SIZES AS GIVEN BELOW UPTO 0.60 METRE AVERAGE DEPTH in cement mortar 1:5 LIME CONCRETE with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 BENCHING 12mm THICK CEMENT PLASTER 1:2 with a floating coat of 1mm thick of neat cement R.C.C.1:2:4 SLAB 100mm THICK /C.C.TOPPING 50 mm THICK WITH 455 MMx455MM/455MMx610MM INSIDE LIGHT DUTY C.I.INSPECTION CHAMBER COVER AND FRAME weight as per I.S.I. specification painted WITH 3 COATS OF black bitumastic superior paint complete as per standard design. (c) Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab)(29.84)

17

-

3795

... More
EXTRA FOR EVERY 0.30 METER DEPTH OF INSPECTION CHAMBER 600mm X 900mm (29.85)

17

-

764.5

... More
Preparation of sub grade, including trenching, rough dressing of spoil, final dressing of earth, to given levels and camber, watering rolling with road roller, and compacting the bed .(24.1)

285

-

3.9

... More
Cement Concrete 1:4:8 with stone aggregate 40mm nominal size in foundation and plinth.(10.39)

44

-

2217.05

... More
Design mix cement concrete of grade M-30 with minimum cement contents 405 Kg./cum in foundation and plinth (10.67)

44

-

4345

... More
Precast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed urface including from work, placing and fixing in position, complete at the ground level or in first storey (10.77)

3

-

5183.75

... More
EXTRA FOR EVERY 0.30 METER DEPTH OF INSPECTION CHAMBER 600mm X 900mm (29.85)

19

-

764.5

... More
Preparation of sub grade, including trenching, rough dressing of spoil, final dressing of earth, to given levels and camber, watering rolling with road roller, and compacting the bed .(24.1)

475

-

3.9

... More
Cement Concrete 1:4:8 with stone aggregate 40mm nominal size in foundation and plinth.(10.39)

73

-

2217.05

... More
Design mix cement concrete of grade M-30 with minimum cement contents 405 Kg./cum in foundation and plinth (10.67)

73

-

4345

... More
Supply and errection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and matrial required to complete the job in all recpect upto to the entire satisfaction of the Engineer-in-charge of the work. Distribution board 8 way SPN (Horizontal) (HSR 31.41 (ii))

5

-

2310

... More
Distribution board 12 way SPN (H) (HSR 31.41 (iii))

4

-

3520

... More
Supply and erection of miniature circuit breaker/isolator 240/415V in the existing distribution board including maki.g necessary connections:- 6A to 32A single pole (HSR 31.17 (a) (ii))

46

-

256.1

... More
40A to 63A SPN (HSR 31.17 (a) (iii))

16

-

728

... More
Supplying and fixing of following rating, double pole, (single phase and neutral), 240 volts, MCB of 10kA in existing DB complete with connections, testing and commissioning etc. as required. 32 amps (single phase and neutral), (HSR 31.17 (a))

10

-

256.1

... More
Wiring in 1.5 Sq.mm (22/0.30mm) PVC insulated unsheathed multistranded copper conductor cable ISI marked 1100 volts grade as per IS-694 in rigid PVC conduit pipe ISI Medium IS- 9537 including bends, MS Round inspection boxes with MS boxes 18 Guage Modular Boxes Zinc Coated as per relevant IS code with all accessories, Including ISI Modular Switch/socket, bell push step type fan regulator, MS Round junction box & covered with 1.5mm thick baklite sheet, with screw and washer including the cost of cable ,PVC pipe, ceiling rose, electronic step type(socket size)fan regulator, cutting and refilling the chases complete in all respect to complete the job. Note:- Inner and outer moulder face plate will be provided in place of 1.50 mm thick backlite sheet no extra payment will be made. Measurement: As classified for the Fan, Light, Bell, Double Control light, 5A socket & 15A Socket etc i.e short, medium, long as per Chapter 31 Condition no. VII. Fan Point Short Point

20

-

519.2

... More
Medium Point

21

-

557.7

... More
Long Point

6

-

683.1

... More
Light Point Short Point

150

-

103.4

... More
Medium Point

73

-

132

... More
Long Point

49

-

157.3

... More
Light Point Twin control Medium Point

6

-

123.2

... More
5 PIN 5 AMP PLUG POINT COPPER WIRE including earthing 3rd pin with 1.5 sq mm. (22/0.30MM) PVC INSULATED UNSHEATHED COPPER WIRE Short Point

136

-

30.8

... More
6 PIN 15 AMP PLUG POINT (In 4Sq.mm Copper conductor Cable including Earthing 3rd pin with 1.5 sq mm. (22/0.30MM) PVC INSULATED UNSHEATHED COPPER WIRE Short Point

71

-

15.4

... More
25 AMP PLUG POINT (In 4Sq.mm Copper conductor Cable including Earthing 3rd pin with 1.5 sq mm. (22/0.30MM) PVC INSULATED UNSHEATHED COPPER WIRE

31

-

107.8

... More
Wiring for circuit/ submain wiring along with earth wire with the following size of FR/PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as reqiured. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

450

-

137.5

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

170

-

147.4

... More
1 x 22 watts LED Ceiling Light Fixture (Philips Linea 22-Watt LED)

47

-

2750

... More
1 x 9 watts LED Wall Light Fixture (Philips Oriel 35024)

69

-

2200

... More
2 x 18 watts LED Ceiling Light Fixture ( Bajaj CLED2X18)

20

-

3520

... More
1 x 12 watts LED Celiling Light Fixture (Philips Ultra Slim Plus)

12

-

1980

... More
1 x 9 watts LED Ceiling Light Fixture (Philips AstraPrime)

58

-

1650

... More
1 x 7 watts LED Ceiling Light Fixture (D/L) (Philips StarGlow)

62

-

1430

... More
5 x 40 watts / 9 x22 watts Ceiling Light Fixture (Center Light) as per local electrical market.

4

-

9350

... More
Supply of following sizes of heavy duty exhaust fan suitable for single phase 230 volts, 50 Hz AC supply complete with motor, capacitor, louvers / shutters etc. complete as required. 300mm dia., 1400 RPM Exhaust fan.(Khaitan Eurocap 12'' Fresh Air Exhaust Fan)

20

-

2729.1

... More
Supply of following sizes of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy, capacitor, electronic stepped regulator of two module heavy duty etc. suitable for operation on 230 volts 50 Hz A.G. ,:upply complete as required. Size 1200mm. (Orient Quasarn)

47

-

3520

... More
Installaion , testing and commissioing of prewired ,flourescent fitting/ compact flourescent fitting of all types, with all accessories and tube etc. directly on ceiling / recessed !wall , including connection with 1.5 sq.mm FR PVC insulated , copper conductor, single core cable and earthing etc. as required.

272

-

248

... More
Wiring for light plug with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4sq.mm FR PVC insulated copper conductor single cable for loop earthing as required.

136

-

696

... More
Wiring for light/power plug with 2x4sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4sq.mm FR PVC insulated copper conductor single cable for loop earthing as required.

102

-

833.6

... More
Erection of exhaust fan/fan complete with necessary earthing of fan and regulator including carriage from local railway station/Goods transport PWD store to the site of work.

67

-

356.5

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 600 mm x 6 mm thick including accessories and providing enclosures accessories and providing enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

4

-

611.55

... More
Extra for charcoal or coke and salt for G.I plate or copper plate earth electrode.

4

-

251.1

... More
P/F 25mm x 5mm G.I. strip in 40mm diameter GI pipe from earth electrode as required

75

-

87.89

... More
Pdg. and fixing 4mm diameter G.I. wire on surface or in recess for loop earthing as required

69

-

4.25

... More
Supply of MS pipe (B-class) for suspension rod of ceiling fan including threading if required 15 mm dia

83

-

27.39

... More
S/E of caution notice plate in three languages.

2

-

2.2

... More
Supply and erection of shock restoration chart in glass frame.

1

-

41.25

... More
Fire protection

1

-

354632



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.