If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 82,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/gur-/nit-64/2019-20 Repair/maint Of Electrical Appliances At Sub Stations Including Replacement Of Capacitor Control Switch, Street Light With Led Fittings, Earthing Pits Etc At Certain Otm Accn And Residential Area At Af Stn Rajokri Of Ge (af) Gu
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_337357_1Bid Award Id
ViewTender No
GE/GUR-/NIT-64/2019-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Voltage stabilizer of capacity 300 KVA three phase
1
-
-
... More
Voltage stabilizer of capacity 450 KVA three phase
2
-
-
... More
M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration, filtration and replacement of silica gel all as directed
Note:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of Job.
3000
-
-
... More
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as directed Note:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.
409
-
-
... More
M&L for defect rectification of HT 11 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV complete all as directed
3
-
-
... More
Supply, jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG)
3
-
-
... More
Supply, jointing and testing outdoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) Note for Item Nos. 5.00 to 6.00:- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate.
3
-
-
... More
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95 Sqmm and laid in trenches/ ducts/ pipe or on poles complete all as specified and as directed.
100
-
-
... More
Ditto all as per item No. 7 described here-in-before but size 3.5 core X 50 Sqmm
150
-
-
... More
Ditto all as per item No. 7 described here-in-before but size 3.5 core X 35 Sqmm
180
-
-
... More
Ditto all as per item No. 7 described here-in-before but size 4 core X 25 Sqmm
300
-
-
... More
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
136
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers
not exc 25 cm thick in soils complete all as specified and as directed.
32
-
-
... More
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
104
-
-
... More
M&L for boring/auguring suitable hole & insertion of 65 mm dia GI pipe including pipe not less than 600 mm below existing PCC/ road/ hard standing complete all as directed.
Notes :- Cost of equipment, tools & plants & material required for boring shall deemed to be included in the quoted rates .
20
-
-
... More
M&L for sand cushioning for cable protection in trenches complete all as specified and as directed.
54
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
4600
-
-
... More
Taking down the existing cables from trenches of any size complete all as directed.
730
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron earth strip 25x4 mm means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering including test point 75x75x25mm all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing on completion complete all as specified and as directed.
8
-
-
... More
Comprehensive maintenance of transformer by isolating, disconnecting of input/output, supply cable, opening of top of transformer, detecting of fault, u/s component etc, cleaning of serviceable parts/ component, including replacement of worn out spare parts etc, if required complete all as directed.
-
-
-
... More
Transformer 300/400 KVA
3
-
-
... More
Transformer 160/250 KVA
2
-
-
... More
Transformer 50/75/100 KVA
3
-
-
... More
Taking out of VCB trolley from HT Control Panel 11 kV, 3 phase, 630 Amp, 18.4 kA (Make CG) and cleaning the trolley with CRC removing all dust, carbon etc greasing the mechanical parts, gears lever charging, male female contact and spring holder & material and labour for calibration of IDMT numerical relay as per existing load for earth fault, over current, short circuit including setting the relay on required electric load and testing on earth fault, short circuit and over load with the help of relay testing kit including replacement of all fuses with existing rating complete all as directed.
9
-
-
... More
M&L for maintain earthing pit complete with copper earth plate electrode size 600 x 600 x 3.15mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level by filling surrounding all sides by mixture of charcoal and common salt and replacing copper earth strip 20X 3 mm means of copper iron bolts, nuts, check nuts and washers and earth strip protected by galvanised pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing to get required result on completion of maintenance complete all as directed.
40
-
-
... More
Taking down and dismantling HPSV street light fitting for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as directed.
45
-
-
... More
Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as directed.
250
-
-
... More
M&L for wiring PVC insulated, stranded sheathed copper cable conductor size 1.5 Sqmm 3 core and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed.
250
-
-
... More
Supply and fix LED street light luminaries IP-66 grade of protection with 24 High power LED of 45 watt rating and extendable up to 48 watt rating with unique peanut lens to ensure uniform distribution complete all as directed. Make: CG or its equivalent in Wipro/ Havells/ Surya
45
-
-
... More
M&L for bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc complete all as directed
45
-
-
... More
Supply and fix in replacement of steel weather proof, dust proof, duly powder coated street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as directed. Make : Hensel/Sintex/Universal Switch Gear control Note:- The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection.
80
-
-
... More
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as directed. Make : Kakatiya/Healer/Bajaj.
Note:- (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr shall deemed to be included in the unit rate. (ii) Provn of glands and lugs shall deemed to be included in the quoted rate.
2
-
-
... More
M&L for rewinding of fans with same gauge of super enamelled copper wire complete varnishing, baking, connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with knots /bolts/ washer /split pin and blade screws etc testing, complete all as directed :-
-
-
-
... More
Ceiling fan 1200 /1400 mm sweep
15
-
-
... More
Exhaust fan 300 mm sweep
15
-
-
... More
Exhaust fan 450 mm sweep
15
-
-
... More
Supply and fix in repair new metal bush bearing made out of gun metal/ brass of same size suitable for ceiling fans, wall mounted fan and exhaust fans complete all as directed.
45
-
-
... More
Supply and fix in repair ball bearing suitable for the following fans: Make: NBC/SKF/Tata
-
-
-
... More
Ceiling fan 1200 /1400 mm sweep
15
-
-
... More
Exhaust fan 300 mm sweep
15
-
-
... More
Exhaust fan 450 mm sweep
15
-
-
... More
Supply and fix in repair capacitor 2.5 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon
60
-
-
... More
Supply and fix in repair capacitor 4 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon
60
-
-
... More
S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as directed
2
-
-
... More
S&F MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as directed
2
-
-
... More
S&F MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as directed
3
-
-
... More
S&F MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as directed
3
-
-
... More
Supply & fix anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified & as directed
100
-
-
... More
Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified & as directed
60
-
-
... More
Comprehensive maintenance of Capacitor bank panel by isolating, disconnecting of input/ output, supply cable, detecting of fault, u/s component in panel ,cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required complete all as directed. Note:- Replacement of Capacitor of various size shall be measured & paid separately
8
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 5 KVAR complete all as directed
8
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 10 KVAR complete all as directed
5
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 15 KVAR complete all as directed
4
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 20 KVAR complete all as directed
4
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 25 KVAR complete all as directed
3
-
-
... More
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 50 KVAR complete all as directed
2
-
-
... More
Comprehensive maintenance of EMF panel by isolating, disconnecting of input/output, supply cable, detecting of fault, u/s component in panel, cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock etc, if required all as specified and directed. Replacement of Contactor, relay, WLC, replacement of old wiring with 2.5 sqmm to 6 sqmm etc. of various size shall be measured & paid separately
8
-
-
... More
Supply and fix in replacement of 32 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as directed. Make: L&T/ Schneider/ Havells
8
-
-
... More
S&F of 3 phase water level controller, 415 Volt, 50 Hz complete all as directed.
5
-
-
... More
S&F of 3 phase phase protector relay, 415 Volt, 50 Hz complete all as directed.
5
-
-
... More
S&F of 3 phase single line preventer 415 Volt, 50 Hz complete all as directed.
4
-
-
... More
Supply, install, testing, commissioning and testing in replacement factory made feeder pillar compartmentalised outdoor type, weather proof, dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder coated, suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars of rating 900 Amps installed on porcelain /SMC insulator with apron for cable entry, closing locking arrangement with and including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS 694 marked, 1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following
Incoming :-
(a) ACB 415, 4 pole, 600 Amp, 50 Hz micro processor based release unit type MP4 LSIG draw out type specially fix for incoming supply with overload short circuit and earth fault protection (service breaking capacity 50 KA with spring loaded liver & key locking in drawn out position with under voltage release and motor operating system for charging as well as manual charging coil complete all as specified and directed - 01 No
2
-
-
... More
Item No. 52.00 Contd.......
Note:- Cost of retrofitting of existing panel shall deemed to be included in the quoted rate (b) Digital Voltmeter 0-500 volts digital type with 4 way rotary selector switch -01 (c) Digital ammeter 0-400 Amp digital type with 4 way rotary switch -01 No
(d) CTs ratio 400/5 A , class 1, ISI marked -01 set of three
(e) Indicating lamps -01 Set of three
Outgoing :-
(a) MCCB 3 pole, 125 Amp, 50 Hz, 415 volts, 36 KA with magnetic and thermal release -04 Nos (b) MCCB 3 pole, 250 Amp, 50 Hz, 415 volts, 36 KA with magnetic and thermal release -02 Nos
(c) MCCB 3 pole, 200 Amp, 50 Hz, 415 volts, 25 KA with magnetic and thermal release -03 Nos Platform of panel:- Platform for the panel with PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate),15 cm thick in foundation, brick work in CM 1:6 with sub class B old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per Manufacturer drawing and design.
-
-
-
... More
Supply, install, testing and commissioning in replacement of AMF panel capacity 62.50 KVA cubical floor mounted type made out of MS sheet of not less than 2 mm thick with both side openable hinged cover for easy accessibility with necessary control circuit fuses aluminium bus bar of suitable size TPN.The panel shall have indicating instruments and switches and provn of incoming and outgoing electric connection. The AMF control panel should be manufactured preferably by the manufacturer of DG set or by the approved manufacturer of LT panels is universal switch gear, shalabh switch gear, milestone or equivalent the following accessories.:- (a) AC voltmeter 0-500 volts flush type - 01 No. Make :- AE/IMP/MECO
(b) Suitable voltmeter selector switch having ON/OFF - 01 No. Make : AE /IMP/MECO
(c) Frequency Meter 100 mm square flush type- 01 No. Make :AE /IMP/MECO
(d) Ammeter 0-200 Amps with CTS flush type - 01 No. Make : AE /IMP/MECO
(e) Battery charger one number ammeter. Make : AE/Havells
1
-
-
... More
Item No. 53.00 contd.....
(i) Transformer /Rectifier unit
(ii) DC ammeter Make : AE/Havells
(iii) Charging rate selector switch off/trickle/Booster. Make AE/ Havells
(f) Main supply air break contactor 3 pole of suitable rating Make : Siemens/L & T /ABB
(g) Alternator air break contactor 3 pole of suitable rating and providing with a separate over load delay for over load protection. Make : Siemens / L & T /ABB
(h) Set of control relays and timer - 01 set (i) Mode selector switch off/auto main test.
(j) Set of push buttons starter /stop/ acknowledge /test /main/ breaker/ close trips - 01 set.
(k) Audio alarm hooter - 01 set (l) KW meter flush type - 01 No. Make : Havells/ Capital/ Jaipur.
(m) Power factor meter - 01 No. Make : Havells /AE/ L & T (n) Suitable size MCCB -02 Nos
-
-
-
... More
S&F, installing, testing and commissioning in replacement of AMF panel capacity 25 KVA cubical floor mounted type made out of MS sheet of not less than 2 mm thick with both side openable hinged cover for easy accessibility with necessary control circuit fuses aluminium bus bar of suitable size TPN.The panel shall have indicating instruments and switches and provn of incoming and outgoing electric connection. The AMF control panel should be manufactured preferably by the manufacturer of DG set or by the approved manufacturer of LT panels is universal switch gear, shalabh switch gear, milestone or equivalent following accessories.:- (a) AC voltmeter 0-500 volts flush type - 01 No. Make :- AE/IMP/MECO
(b) Suitable voltmeter selector switch having ON/OFF - 01 No. Make : AE /IMP/MECO
(c) Frequency Meter 100 mm square flush type- 01 No. Make :AE /IMP/MECO
(d) Ammeter 0-200 amps with CTS flush type - 01 No. Make : AE /IMP/MECO
(e) Battery charger one number ammeter. Make : AE/Havells
1
-
-
... More
Item No. 54.00 contd.... (i) transformer /Rectifier unit
(ii) DC ammeter Make : AE/Havells
(iii) Charging rate selector switch off/trickle/Booster. Make AE/ Havells
(f) Main supply air break contactor 3 pole of suitable rating Make : Siemens/L & T /ABB
(g) Alternator air break contactor 3 pole of suitable rating and providing with a separate over load delay for over load protection. Make : Siemens / L & T /ABB
(h) Set of control relays and timer - 01 set (i) Mode selector switch off/auto main test.
(j) set of push buttons starter /stop /acknowledge /test /main/ breaker/ close trips - 01 set.
(k) Audio alarm hootere - 01 set (l) KW meter flush type - 01 No. Make : Havells/ Capital/ Jaipur.
(m) Power factor meter - 01 No. Make : Havells /AE/ L & T (n) Suitable size MCCB -02 Nos
-
-
-
... More
M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 1.1 KV complete all as directed
3
-
-
... More
Supply, jointing and testing indoor/outdoor type cold shrinkable straight through cable joint including all material and accessories suitable for 3.5 core X 50-95 Sqmm XLPE cable of 1100 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) Note :- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate.
2
-
-
... More
Supply and fix in replacement of Lead acid maintenance free Battery 12 Volts 120 AH of existing type & size suitable for DG Sets. Make : EXIDE/AMCO including initial charging.