Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Paints and Enamels
Eprocure
Opening Date28 Mar 2025
Closing Date19 Apr 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl item No 01 here in before but of capacity 1,50,000 Gallons all as specified and directed by Engineer - in - Charge.

4

-

-

... More
All as per Srl item No 01 here in before but of capacity 2,00,000 Gallons all as specified and directed by Engineer - in - Charge.

3

-

-

... More
All as per Srl item No 01 here in before but of capacity 3,00,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
De-watering, de-sludging (solid sludge or liquid mud) and cleaning the filter bed balancing tank 1,00,000 Gallons capacity by using pump or manually as required at site. Bottom and side walls of tank shall be cleaned by scraping with wire brush and cotton cloth till the concrete surface is become visible. After cleaning operation bottom and internal wall shall be washed with bleaching powder and potable water and painting internal surfaces with two coats of white wash suitable for drinking water.The sludge and liquid mud shall be removed outside the MOD land as directed by Engineer-in-Charge.

1

-

-

... More
De-watering, de-sludging (solid sludge or liquid mud) and cleaning the RCC Semi-underground jack well reservoir of 50,000 Gallons capacity by using pump or manually as required at site. Bottom and side walls of sump shall be cleaned by scraping with wire brush and cotton cloth till the concrete surface is become visible. After cleaning operation bottom and internal wall shall be washed with bleaching powder and potable water and painting internal surfaces with three coats of white wash suitable for drinking water and with two coats of cement based paint on external surfaces including scrapping of old surfaces. The sludge and liquid mud shall be removed outside the MOD land as directed by Engineer-in-Charge.

2

-

-

... More
All as per Srl item No 08 here in before but of capacity 1,00,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
De-watering, de-sludging (solid sludge or liquid mud) and cleaning the RCC Semi-underground/ underground sump of 20,000 Gallons capacity by using pump or manually as required at site. Bottom and side walls of sump shall be cleaned by scraping with wire brush and cotton cloth till the concrete surface is become visible. After cleaning operation bottom and internal wall shall be washed with bleaching powder and potable water and painting internal surfaces with three coats of white wash suitable for drinking water and with two coats of cement based paint on external surfaces including scrapping of old surfaces.The sludge and liquid mud shall be removed outside the MOD land as directed by Engineer-in-Charge.

4

-

-

... More
All as per Srl item No 10 here in before but of capacity 50,000 Gallons all as specified and directed by Engineer - in - Charge.

3

-

-

... More
All as per Srl item No 10 here in before but of capacity 70,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
All as per Srl item No 10 here in before but of capacity 1,00,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
All as per Srl item No 10 here in before but of capacity 1,50,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
All as per Srl item No 10 here in before but of capacity 2,00,000 Gallons all as specified and directed by Engineer - in - Charge.

2

-

-

... More
All as per Srl item No 10 here in before but of capacity 3,00,000 Gallons all as specified and directed by Engineer - in - Charge.

5

-

-

... More
All as per Srl item No 10 here in before but of capacity 4,00,000 Gallons all as specified and directed by Engineer - in - Charge.

1

-

-

... More
Cleaning of semi under ground open Raw water reservoir by removing balance water and taking out solid residual loose dirt, scales, muds, clay, fungus vegetation growth ,any other foreign material, scrubbing the complete inner surface wall and floor with wire brushes and cleaning with water and again cleaning and washing completely using bleaching powder and writing in bold letter date of cleaning on outside surfaces of raw water reservoir so that distinctely visible of capacity 32 Lakh Gallons, Cleaning the surrounding area of the reservoir to a distance of 3 mtrs apart all around its circumference incl cutting of grass digging out roots, filling holes, levelling of ground removing the deposited material to a distance not exc. 500 metres at Main pump house at Chandimandir Mil Stn under GE(U) Chandimandir all as specified and directed.

1

-

-

... More
Note:- (i) No T&P will be issued by the department for doing the above work, it shall be arranged and provided by the contractor Like Motor ,pump for dewaterning of water ,wire brush, etc. (ii) No mechanical T&P will be allowed inside the raw water tank for removal of sludge.

-

-

-

... More
Cleaning of semi under ground open Raw water reservoir by removing balance water and taking out solid residual loose dirt , scales , muds,clay, fungus vegetation growth ,any other foreign material, scrubbing the complete inner surface wall and floor with wire brushes and cleaning with water and again cleaning and washing completely using bleaching powder and writing in bold letter date of cleaning on outside surfaces of raw water reservoir so that distinctely visible of capacity 100 Lakh Gallons, Cleaning the surrounding area of the reservoir to a distance of 3 mtrs apart all around its circumference incl cutting of grass digging out roots, filling holes, levelling of ground removing the deposited material to a distance not exc. 500 metres at Mansa Devi Pump house at Chandimandir under GE(U) Chandimandir all as specified and directed.

1

-

-

... More
Note:- (i) No T&P will be issued by the department for doing the above work, it shall be arranged and provided by the contractor Like Motor ,pump for dewaterning of water ,wire brush, etc. (ii) No mechanical T&P will be allowed inside the raw water tank for removal of sludge.

-

-

-

... More
M&L for carefully washing out settled mud, alum, flocculant, etc from flocculator tank 12.19m dia and 4.5m depth including external channels, chambers and outlet etc. Drainning out complete waste water from tank by mannually or mechanical arrangment cleaning of bottom, all internal side walls, channel by using brooms, wiper or nylon brush, up to satisfaction of Engr-in- charge. Applying one coat of super quality lime wash to internal & external surface complete all as specified and directed.

3

-

-

... More
All as per Srl item No 20 here in before but flocculator 15,000 gallon capacity including lime & Alum mixing chambers 03 Nos, intake chamber complete all as specified and directed.

3

-

-

... More
Maintenance of clarifloculator complete with oiling, greasing and welding as required of flocutation motors, bridge driving unit motor, moving rail including painting with two coats of synthetic enamel paint complete all as specified and directed.

2

-

-

... More
M&L Glow sign board of size 10'0" x 3'0" x 0'6'', design, composition, supply & Installation of single sided lit signage made from 3mm acrylic sheet both side and aluminium frame, IP 68 protection, LED modules of samsung or equivalent with appropriate power supply & ISI mark electrical fitting, Inside graphics - 3 M graphics pasted on 3mm acrylic sheet ISO:9001-2008 product with premium grade anodizing as per IS standards with 2 years warranty under normal working conditions complete all as directed.

1

-

-

... More
Supply and fixing as in replacement multi stranded copper conductor cable PVC insulated unearthed 1100Volts grade of size 1.50 Sqmm 2.00 Core for connection all as specified and directed.

200

-

-

... More
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint all as specified and directed by Engineer - in - Charge .

50

-

-

... More
Testing of raw water of Main filter pump house & Mansa Devi Pump House at Chandimandir Mil Stn Under GE (U) Chandimandir. (a) Microbiological requirement cues. (b) Organoleptic and physical parameters. (c) General parameters concerning substances.Undesirable in excessive amount. (d) Parameters concerning Toxic substances. (e) Pesticide Residue. Note: The testing should be carried out from approved NABL lab.

4

-

-

... More
Testing of Clear water of Main filter pump house & Mansa Devi Pump House at Chandimandir Mil Stn Under GE (U) Chandimandir. (a) Microbiological Requirement Cues. (b) Organoleptic and physical parameters. (c) General parameters concerning substances. undesirable in excessive amount. (d) Parameters concerning Toxic substances. (e) Pesticide Residue. Note: The testing should be carried out from approved NABL lab.

4

-

-

... More
M&L for Bacteriological/ Chemical testing and analysis with preparation of detailed report as per IS 10500:1991 after collection of samples at various locations at Chandimandir Mil Stn all as specified and directed by Engr-in-Charge. Note: (a) The testing will be conducted by Govt Approved Labs only. (b) The contractor will make suitable arrangements for collection of sample water at various locations with prior intimation to Engr-in-charge.

5

-

-

... More
Supply and fixing as in replacement of DOL starter for induction motor capacity of 5 HP, three phase, 415 V, 50 Hz as specified and directed by Engr-in-charge.

4

-

-

... More
Supplying and fixing as in replacement cast iron rising sluice valve, SS spindle 100 mm bore, flanged ends PN-1.6, ISI marked as per IS:14846/2000 and CI operating wheel fitted / fixed in position, including taking up / down old valve, including gasket, nuts, bolts and washers complete all as specified & directed.

3

-

-

... More
Supplying and fixing as in replacement cast iron rising sluice valve, SS spindle 150 mm bore, flanged ends PN-1.6, ISI marked as per IS:14846/2000 and CI operating wheel fitted / fixed in position, including taking up / down old valve, including gasket, nuts, bolts and washers complete all as specified & directed.

4

-

-

... More
Supplying and fixing as in replacement cast iron rising sluice valve, SS spindle 200 mm bore, flanged ends PN-1.6, ISI marked as per IS:14846/2000 and CI operating wheel fitted / fixed in position, including taking up / down old valve, including gasket, nuts, bolts and washers complete all as specified & directed.

5

-

-

... More
Supplying and fixing as in replacement cast iron rising sluice valve, SS spindle 250 mm bore, flanged ends PN-1.6, ISI marked as per IS:14846/2000 and CI operating wheel fitted / fixed in position, including taking up / down old valve, including gasket, nuts, bolts and washers complete all as specified & directed.

4

-

-

... More
Supplying and fixing HDPE water proof pond liner (07 layer) heavy duty blue/ black colour, ISI marked, having 10 cm overlap material including cleaning wall with wire steel brush removing rubbish from the installation and fixed all as per manufaturer's instruction with and including fixing material complete all as all as specified & directed by Engr- in - Charge. Specifications of material is as under: Thickness: 1000 Micron Tensile Strength at Break (MD) 20 MPa Tensile Strength at Break (TD) 20 MPa Elongation at break (MD) 1000% Elongation at break (TD) 1000% Tear strength (MD) 6.5 Kgf/mm Tear strength (TD) 6.5 Kgf/mm Falling dart impact 2200 G

2200

-

-

... More
Supplying and fixing as in replacement cast iron non return valve, 150 mm bore, flanged ends, PN-1.6, ISI marked fitted / fixed in position, including jointing materials gasket, nuts, bolts and washers complete all as specified & directed.

4

-

-

... More
Supplying and fixing as in replacement cast iron non return valve, 200 mm bore, flanged ends, PN-1.6, ISI marked fitted / fixed in position, including jointing materials gasket, nuts, bolts and washers complete all as specified & directed.

5

-

-

... More
Supplying and fixing as in replacement cast iron non return valve, 250 mm bore, flanged ends, PN-1.6, ISI marked fitted / fixed in position, including jointing materials gasket, nuts, bolts and washers complete all as specified & directed.

4

-

-

... More
Supply and fixing as in replacement Ductile iron Foot Valve, PN 10, EPDM seal with Galvanized steel strainer, as per IS 4038 of size 150mm, complete all as specified and directed.

4

-

-

... More
S & F as in replacement chloronome gaseous plant (Chlorinator) of Capacity 4000 gms/hr In built parts Vacuum regulator with inbuilt Filter , Pressure Gauge ,In built Measuring Glass with dose rate adjuster, Vacuum Ejector, Ejector Non Return Valve, PE tubing, 32 mm Spanner complete all as specified and directed.

1

-

-

... More
Supply and fixing as in replacement Cast iron butterfly valve of 300 mm bore,wafer type,PN 10, ISI marked inluding jointing material complete all as specified and directed.

4

-

-

... More
Supply and fixing as in replacement submersible cable 3 core 10 sqmm multi stranded copper conductor complete all as specified and directed by Engr-In-Charge.

100

-

-

... More
Surface dressing not exceeding 15cm deep including cleaning away all grass vegetation, sapling, shrubs, brushwood, undergrowth, roots and removing rubbish upto a distance of 50 Metres outside the periphery of the area complete all as specified and directed by Engineer - in - Charge.

4000

-

-

... More
Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge.

5

-

-

... More
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .

5

-

-

... More
M & L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge .

4

-

-

... More
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .

20

-

-

... More
M & L for framed work for valve pit chamber cover made of MS angle and MS sheet 3 mm thick including welding, cutting, hinges, locking arrangments complete all as specified and directed.

200

-

-

... More
M & L providing two coats of synthetic enamel paint and a coat of red oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .

10

-

-

... More
Design, fabricate, supply, installation, testing and commissioning in replacement of indoor type dust proof & vermin proof cubicle panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility.

1

-

-

... More
Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box.

-

-

-

... More
The size of panel board shall not be less than 1200mm x 850mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed with and incl the following Bus Bar :- (a) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set.

-

-

-

... More
Indication devices:- (a) Multifunction digital meter compatible to measure current, voltage, power factor & frequency with 3 lines LCD display in 96 x 96 sqmm flush mounted case, accuracy class 1.0 - 01 No. (b) Resin cast CT 250/5A cast resin base – 01 set of 03. (c) LED type phase indicator lamp RYB – 02 set of three (d ) On/Off push buttons - 04 and selector switches - 02 Nos complete all as specified and directed. INCOMING :- (a) I/C fast acting Semiconductor Fuse 250 A - 03 Nos (b) MCCB 3 pole, 200 Amps, 415 volts, 50 Hz, Ics = 100% Icu of breaking capacity 36 kA, adjustable thermal & fixed magnetic release type - 01 No (c) ) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 185 Amps-01 No. (d) Control Transformer copper wound of suitable capacity- 01 No

-

-

-

... More
Outgoing :- (a) Digital soft starter suitable for120 HP(90KW) motor, 3 phase, 415 Volts - 01 Nos (b) MCB TP 32 Amp C curve - 01 Nos (b) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 12.5 kVAr – 2 Nos (c) Capacitor duty contactor, 3 phase, 415 volts, 50 Hz, of rating 8.5 kVAr – 2 Nos (d) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 10 KVAR - 02 Nos (e) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 Nos Note : (i) All existing and new connections of incoming/ outgoing cables shall be done through appropriate size of copper thimbles. (ii) Drawing, circuit diagram and all materials / instruments incl makes etc for starter panel shall be got approved by GE before fabrication.

-

-

-

... More
Notes for Ser Item No 01 to 22 (a) Entire materials labour, engineer, supervisor, plant & tools required for executing the work and for safety of persons deployed on the work shall be contractor’s arrangement and responsibility. (b) Before completion of work in each reservoir, writing letters or figures for date of cleaning and capacity of tank with synthetic enamel paint with black background & letters / numbers in white colour & words size 10cm height on tank with contractors name and due date for next cleaning shall be marked on the reservoir by the contractor without any extra cost to department . (c) All safety measure and procedure including insurance of deployed personals and to ensure safe execution of cleaning, disinfecting, radiation and finishing process of entire work shall be contractor's responsibility without any extra cost to department.

-

-

-

... More
Note:- (i) No T&P will be issued by the department for doing the above work, it shall be arranged and provided by the contractor Like Motor ,pump for dewaterning of water ,wire brush, Bleaching Powder, lime ,ladder up to 30 mtr /Scaffolding up to 30 mtr if required etc. (ii) Necessary T&P , pumping set, Dewatering pump , Sludge Removal pump ,pipes etc shall be arranged by the contractor. Required safety equipments such as hand gloves, headgears, masks, gum boots, oxygen gas cylinders etc shall also be arranged by the contractor. Labour trained in cleaning of OHT, semi under ground/above ground water reservoir/tanks sumps shall only be deployed to carry out the above job. Entire responsibility for safety of the deployed labour shall be of the contractor and deptt shall not be responsible for any mishappening or any type of loss occured during the execution of above job. Unit rate quoted shall be deemed to include the cost of all the above factors and no extra payment shall be made for the same.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.