Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,29,970Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677896_1Tender No
CWE/CHM (U)-75/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
NOTE :-
Lift OEM to submit detailed specification/ design parameters, construction drawings of all components of lifts as per IS-14665 and as per latest amendement for approval of GE before execution of work. Engr-in-Charge shall ensure that detailed drawings shall be forwarded to GE for approval with recommendation within one month of issue of Work Order. Specification of the lift are as under:- (a) Type of Lifts: Goods Lift/ Service lift
(b) No. of Passengers & Load capacity: 680 kgs/ 10 Persons
(c) Speed: 1.5 mtr/sec (d) Rise : 22 M
(e) Stops : 7 Stops with (all Opening on the same side)
(f) Controller Type : LVA/ ACD (Low Voltage Architecture/ Asian Controller and drive)
-
-
-
(g) Type of Drive: VF Regenerative (Closed Loop).
(h) Power Supply : 400/ 415 volts, 3 phase AC, 50 Hz (i) Operation : Full Collective Operation
(j) Car Group : Two Cars (Duplex) (k) Type of Machine: PM Gearless (located above shaft)
(l) Traction Media : Flat Coated Steel Belt
(m) Car Finish : Rear mid Panel, Rear Corner Panel/ Side Mid Panels, Side Corner Panels & Front panels : Stainless Steel/ Gold Finishes/ Vandal Proof or as approved (Hairline/ Mirror/ Gold) (n) False Ceiling Type/ Finish : CD-41/ CD-42/ CD 35 as approved, Stainless steel (Hairline/ Mirror/ Gold) (o) Ventilation : Cross Flow Fan
-
-
-
(p) Hand Rails : Stainless Steel Mirror Finish Haindrails on Rear Car Panels
(q) Flooring : Vinyl Tiles of colour (Sea Blue/ Pink/ Almond/ White/ Grey/ Steel Grey) as approved by GE.
(r) Car Door Finish/ Landing door Finish : Stainless Steel/ Gold Finsihes/ Vandal Proof or as approved (Hairline/ Mirror/ Gold) (s) Fire Rated Doors : Fire Rating - 120 mins (t) Pit Depth : 1600 (u) Overhead : 4500
(v) Hoistway Dimensions : 2250mm W x 1700 mm D
(w) Car Dimensions (W X D X H) : 1300 mm W x 1350 mm D x 2200 mm H
(x) Car & Hoistway Door Type : Central Opening (CO Doors) Door Opening (W X H- mm) - 8000 mm W x 20000 mm H
(y) Door Opening : DC Door operator (z) COP : COP for stops less than = 12 (950 mm) in Stainless Steel/ Gold Finsihes/ Vandal Proof or as approved (Hairline)
-
-
-
(aa) Car Position Indicator : Monochrome LCD - Blue Background & White font
(ab) Hall Fixture/ Hall Fixture Face plate : 02000, Stainless Steel/Gold Finsihes/Vandal Proof or as approved (Hairline/Mirror/Gold)
(ac) Hall Button Arrangement : Hall Button with HPI (Hall position Indicator)
(ad) Standard Feature : Anti nuisance Car Call Protection, Independent service ( for duplex only), overload device, nudging, Emergency Firemen's Services, Emergency car Light unit, Infrared Curtain Door protection, Door time protection, Emergency alarm button, Extra door time of lobby & parking, Dooir open/ Close buttonm, Manual rescue Operation, Belt inspection drive & auto fan cut off.
(ae) Options included : Automatic Rescue Operation and audible car call button.
(af) Counter weight shall be of cast iron as recommended by OEM as per IS.
(ag) Car counter weight Guide: Guide rails of `T' Section Mild steel as per OEM design as per IS.
-
-
-
Safety device : (i) Automatic rescue device (ARD)/automatic landing device to be operating with maintenance free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of Regenerative drive.
(ii) The ARD actuation time should be less than ten second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.
-
-
-
Machine room: Located above the hoist way .
(i) Hoist way Constn; existing RCC structure with brick wall construction as existing at site. Total height from Ground Level to slab of Machine room can be seen at site.
(ii) Civil work : Necessary Civil work such as scaffolding in elevator shaft, cutting, making holes, grouting/ welding barricading for all openings of elevators to avoid accidents & disturbances during pre and post erection of lift and making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine, plastering of lift shaft wall etc and two coats of white wash shall be applied on the lift shaft after completion of lift installation and all as per OEM recommendation/ suggesting during execution of work.
-
-
-
(a) Provn of safety guarding equipments such as 02 Nos Pit switches controller guarding pit pulley, guarding pit ladders, fascia plate to cover free space between car cabin and hoist way & switches.
(b) Do's & Don'ts chart on stainless steel to be installed inside the car cabin.
(c) Eavacuation process chart to be installed inside the car cabin. Incase when lift stuck in midway shaft, The letters/ Numbers in chart should be luminous radium coloured to see in all day/ night time.
-
-
-
Material & Labour for earthing with Copper earth plate electrode of size copper plate 60 cm × 60 cm × 3.15 mm thick electrode and thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the copper earth lead by means of bolts, nuts check nuts and washers of Copper using 20 × 3mm copper strip as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20 mm graded stone aggregate pit, funnel, 20 mm dia GI medium grade watering pipe, 40 mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 80 mm thick made of RCC (1: 1:5: 3) type A-1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs, etc, mest, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable earth plate complete all as specified & directed by Engineer-in-Charge.
5
-
-
Note :- Each protection pipe and earth lead upto and including 7.50 M length is deemed to be included in unit quoted rate of this item.
-
-
-
Supply & fixing of Copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete from machine room equipment to earth pit complete all as specified and as directed by Engineer-in-Charge.
60
-
-
Supply, laying and testing LT cables, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty), 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge.
25
-
-
Supply, laying and testing LT cables, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty), 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
18
-
-
M&L for GI Tubing, light grade, of 40 mm dia for laying under floor/ wall/ under road for cable potection complete all as psecified and as directed by Engineer-in-Charge.
15
-
-
S&F of Electrical Insulating Mat of size 1 Meter X 2 Meter of thickness 2.0 mm, comforming to IS : 15652/ 2006 as per sample complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Taking down carefully copper/ aluminium point wiring any type (light, fan socket or power) complete (fittings such as switches, ceiling roses pendants, regulators, sockets etc) and removing retrieved materials from site and making good disturbed surfaces of walls floors etc. complete all as specified and as directed by Engineer-in-Charge.
16
-
-
Point wiring with approved colour coded multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, with two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed stove enamelled dteel conduit terminated on and including new steel sunken boxes 1.2 mm thick covered with provision of 3mm thick plastic laminated sheet, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator complete all as specified and as directed by engineer-in-charge.
Note: Quoted rate shall be inclusive of cutting chases in wall/ floor/ PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
12
-
-
All as per serial item 10.00 here-in-before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and as directed by engineer-in-charge.
2
-
-
All as per serial item 10.00 here-in-before but One socket outlet 3/5 pin, 6/16 Amp, independent board, with 2.5 Sqmm (nominal area) FRLSH cable & 2.5 Sqmm (nominal area) cable as earth continuity conductor complete all as specified and as directed by engineer-in-charge.
2
-
-
S&F modular switch one way 6 Amps, one module, 230 volts, single pole, complete all as specified and as directed by engineer-in-charge.
14
-
-
S&F modular switch one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by engineer-in-charge.
2
-
-
S&F modular socket outlet 2 in 1, 3/5 pin 6 Amps two module 230 volts complete all as specified and as directed by engineer-in-charge.
2
-
-
S&F modular socket outlet 2 in 1, 6/16 Amps, two module, 230 volts complete all as specified and as directed by engineer-in-charge.
2
-
-
Supply & fixing modular metal flush box, 8 module, complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply & fixing modular white cover plate with frame, 8 module, complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply and fix ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals complete all as specified and as directed by Engineer-in-Charge.
12
-
-
Supply & Fixing integrated LED Bulk Head fitting of 5 watts complete with PDC aluminium housing and milky diffuser complete all as specified and as directed by Engineer-in-Charge.
12
-
-
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.00 sqmm, LT, 1100V grade, down through and including stove enamelled steel conduit of appropriate dia and one run of 4.00 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion including dismantling old unserviceable submain wiring complete all as specified and as directed by engineer-in-charge.
7
-
-
Note: 1. Two runs of cable, one run of earth wire and one run of stove enamelled steel conduit shall be measured as one run length.
2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
-
-
-
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-charge.
7
-
-
Supply, installation, testing and commissioning of cubical type, CPRI approved, dust and vermin proof, factory made LT panel board, indoor type, front opening (double shutter) with locking arrangement of suitable size made out of 2.0 mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring, thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1) of suitable size as per panel board 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle iron including taking down old unserviceable LT panel board with all accessories and supply & comprising of the following including internal pre-wiring complete:- 400 Amps capacity copper bus bar strip - 4 Nos. of suitable length.
1
-
-
INCOMING
(i) MCCB FP 100 Amps, breaking capacity 25kA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No.
(ii) Voltmeter 0-500 V with selector switch (Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set
(iv) Indicator lamp neon/ LED type RYB -01 Set of three.
OUTGOING:
(i) MCCB FP 63 Amps, breaking capacity 25kA, 4 pole, 3 phase, 415 volts - 02 Nos.
(ii) MCB SPN 40 amps, capacity 10 KA single phase - 02 Nos
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%