Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 99,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681934_1Bid Award Id
ViewTender No
GE (AF) Gurgaon No 1/GUR-64/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Comprehensive monthly maintence of auto fire alarm system installed in 13 BRD/16 BRD /27 ED AF Stn Palam. The detail scope of work consists of the following :-
(i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (vii) Testing of entire fire alarm system and rectification of fault complete to the entire satisfaction of engr-in-charge all as specified and directed .
99
-
-
... More
Supply and installation in replacement of response indicator lamp complete all as specified and as directed.
5
-
-
... More
S&F in replacement of addressable duct detector with multiple sensitivity level, programmable for timed automatic sensitivity and with base UL listed complete all asspecified and directed.
1
-
-
... More
S&F in replacement of Analogue addressable control modules complete all as specified and directed.
3
-
-
... More
S&F in replacement of Analogue addressable fault isolator module capable of monitoring shorted loop circuit and automatically restore communication when shorted conditions are re corrected complete all as specified and directed.
3
-
-
... More
S&F in replacement of Addressable Dual tone electronic sounder / hooter enclosed in MS box with LED indication hooter complete all as specified and directed.
3
-
-
... More
M&L 2x1.5sqmm+1x1sqmm PVC insulated unsheathed, FRL Smultistr and edcopper conductor cable,1100V grade asper IS1554 Part Idrawn through and including ERW steel conduitnot less than 20 mm dia duly painted complete all asspecified and directed.
200
-
-
... More
M&L 2x4.0 sq mm +1x2.5 sq mm PVC insulated unsheathed, FRL Smultistr and edcopper conductor cable, 1100V grade asper IS1554 Part I dra wn through and including ERW steel conduit not less than 20mm dia duly painted complete all asspecified and directed.
100
-
-
... More
S&F in replacement of 9 volts DC battery for wireless smoke detector complete all as specified and as directed.
50
-
-
... More
S&F in replacement of hooter radio meter operating voltage 15 volts DC, indication alarm 85 db, complete all as specified and directed.make : AGNI Protection/Quatac/Honey well
2
-
-
... More
S&F in replacement of MCP remote key of black colour including testing with battery complete all as specified and directed. Model no AP RE-920 of make : AGNI Protection/Quatac/Honey well
5
-
-
... More
M&L in replacement of wire less smoke detector having 9 volt DC battery, smoke sencor temp range (10-70 ) degree centigrade, humidity range 20 % to 95 %, including testing complete all as specified and directed. Model no AP SD-900 of make : AGNI Protection/Quatac/Honey well
10
-
-
... More
Supply and fixing in replacement of response indicator as per existing make and model complete all as specified and directed.
10
-
-
... More
Supply and installation in replacement of 12 volt 7 AH battery complete all as specified and directed. Make - Exide /Amaron/ Luminous/ Amco
5
-
-
... More
Taking down of old unserviceable optical type smoke detector and supply and testing of detectors complying with and type certified to EN-45 adjustable type smoke detector Photo electric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed . Make Cooper/Honeywell/Ravel/Apollo
15
-
-
... More
Supply and fixing in replacement of mother board suitable for Fire alarm system complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
3
-
-
... More
Supply and fixing in replacement of Power Supply card suitable for Fire alarm system complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
3
-
-
... More
Supply and fixing in replacement of manual call point resettable type complete as directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
3
-
-
... More
Supply and fixing in replacement of electronic sounder cum strobe complete all as directed.Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
4
-
-
... More
Supply and fixing in replacement of Repeater Panel 08 Zone complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
2
-
-
... More
Supply and fixing in replacement of 1.5 sqmm three core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cable drawn through existing conduit connecting and testing all as specified and directed.
200
-
-
... More
Supply and fixing in replacement of Heat Detector with Base complete all as specified and directed. Make : Apollo/ Honeywell/Ravel/ Copper
10
-
-
... More
Supply, installing, connecting and testing in replacement of Three phase automatic change over switch of capacity TPN 63 Amps complete all as specified and directed.
1
-
-
... More
M&L in replacement of 4.0 sq mm 3 core PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade as per IS1554 Part I drawn through and including ERW steel conduit not less than 20 mm dia duly painted complete all asspecified and directed.
50
-
-
... More
Comprehensive monthly maintence of 3 X 30 KVA UPS system installed in 13 BRD AF Stn Palam. The detail scope of work consists of the following :-
(i) Execute diagnostics and physical checks.
(ii) Examine, clean, test, all equipment as required and repair parts as and when required.
(iii) Measurement of UPS parameters like input/output voltage, frequency, current, frequency, room temperature etc.
(iv) Battery Parameters like voltage, current and other relevant parameters.
(v) Ensure dust free and controlled temperature conditions.
(vi) The corrective maintenance may require multiple visits to site (vii) Check all Equipment LED LCD display board if any fault found to be rectified in the same cost.(viii) Checking of servicibility of MCB/MCCB if found unserviceagle to be replace without any extra cost. (ix) Checking of UPS fuse. if found us to be replace.(x) Keeping of servicibility of UPS is the responsibility of the contractor for the entire contract period.
Note : Response time should be not more than 24 hours from the time of receipt of complaint on any working day between 9 AM to 6 PM.
9
-
-
... More
Disconnect the unserviceable battery lead connections from 65 AH SMF battery of 30 KVA UPS and transport the us battery to work shop for reconditioning work by using dedicated battery regenerator. Sulfation on plates should be removed by using high powered pulses, replace the us battery terminals , replace the electrolyte and recharge the battery upto 24 to 36 hours to gain more than 12 volts. After completion of reconditioning work the battery will be refix at the same position including necessary testings complete all as specified and directed.
30
-
-
... More
Disconnect the cable connection from unserviceable electric siren from site and refixing the same after completion of necessary repair work complete all as specified and as directed
2
-
-
... More
Supply and installation in replacement of 12 volt 65 AH battery for 30 kVA UPS complete all as specified and directed. Make - Exide /Amaron/ Luminous/ Amco
30
-
-
... More
M&L for opening of electric siren motor and , cutting the burnt winding from motor and rewinding the motor with super enamelled copper wire as per existing size and gauge with and including provision of insulating material varnishing with good quality varnish including replacement of all unserviceable parts such as safety pin, fan blade,bearings and three core copper wire etc complete all as specified and as directed by Engr-in-charge.
2
-
-
... More
Repair/Servicing of Siren,horizontal double mounting, single phase,audible range 3.25 KM at 220/250 volt, 6000 rpm, 50 Hz, AC complete all as specified and directed.
2
-
-
... More
M&L in replacement of 3 core copper conductor of size 2.5 sqmm cable 1100V grade complete all as specified and as directed by Engineer- in Charge.
200
-
-
... More
Disconnect the cable connection from unserviceable single phase AMR meter from existing meter panel box and deposit to MES office complete all as specified and as directed
30
-
-
... More
Disconnect the cable connection from unserviceable three phase AMR meter from existing meter panel box and deposit to MES office complete all as specified and as directed
6
-
-
... More
S&F in replacement of unserviceable Single Phase AMR Meter with the following specifications:
• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.
• Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand
• Meter should have connect / disconnect functionality operable from billing software
MAKE: Secure, L&T, Schnieder, Bentec
30
-
-
... More
S&F in replacement of unserviceable Three Phase AMR Meter with the following specifications:
• AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.
• Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand
• Meter should have connect / disconnect functionality operable from billing software
MAKE: Secure, L&T, Schnieder, Bentec
10
-
-
... More
M&L for repair of single phase AMR meter two wire LCD dispaly/ dial type any make 5-30 Amps complete all as specified and as directed by Engineer- in Charge.
20
-
-
... More
M&L for repair of three phase AMR meter four wire LCD dispaly/ dial type any make complete all as specified and as directed by Engineer- in Charge.
10
-
-
... More
S&F ISI marked electric energy meter single phase two wire LCD dispaly 5-30 Amps complete all as specified and as directed by Engineer- in Charge.
8
-
-
... More
S&F ISI marked electric energy meter three phase four wire LCD dispaly 10-60 Amps complete all as specified and as directed by Engineer- in Charge.
8
-
-
... More
Supply and fix in repairs MS pipe fitting as bends, tees, collar, branch pieces, cap & plug etc, both ends flange welded complete with replacement of nuts and bolts all as specified and directed by Engineer-in-Charge
200
-
-
... More
Supply and fixing in replacement of MS ERW pipe C class of 300 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
12
-
-
... More
Supply and fixing in replacement of MS ERW pipe C class of 150 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
8
-
-
... More
Supply and fixing in replacement of MS ERW pipe C class of 100 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
8
-
-
... More
Dismantling of existing water header of size 300 mm dia and length of 6.5 Rm including cutting and dismantling of welding from supply and distribution line ( Supply line 150 mm -04 Nos, Distribution line-150 mm -02 Nos and 100 mm -04 Nos) by arranging crane or suitable labour as required for lifting the unserviceable header aside including dismantling existing pcc and and supply and fixing of new header with necessary cutting in 300 mm line, 150 mm line, 100 mm line and necessary welding works including fixing of flanges with rubber gasket and nut bolts complete for wrater connection as dismantled above and as directed and making PCC foundation for support of Header (Note : MS pipe for header of different will be measured seperately) checking for satisfatory working all as directed by EIC. Note : Job for replacement of header shall be done with gurantee during the contract period and any defects after fixing shall be rectified by the contractor at his own cost.
1
-
-
... More
(i) Dewatering the tank/UG Sump with portable submersible pump set with flow rate of 30,000 ltrs per hr. (ii) Removal of left over dirty water and sludge with special sludge removal pump set having capacity up to 1.7 lakh ltrs per hr. (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet with the help of German equipment which create pressure of 80-120. (iv) Removing of remaining sludge from the floor with the help of industrial vaccum cleaner. (v) Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful pathdons. The dose utilise should be as per OECD guide No 432 .
(vi) Treatment of inside tank be exposing UV radiation kill the suspended or floating bacterial remaining in the tank
(vii) The cleaning of water reservior will be done two times on half yearly basis.
(viii) Cleaning and removing all scale & dirt from bottom & walls and from mouth of circulation pipes of overhead tank of any capacityat staging height exceeding 15 metre and not exceeding 21.5 metre and disinfecting chemical the same using disinfecting chemical (chlorine) complete.
-
-
-
... More
(a) Service PVC tank of capacity of 10,000 Ltrs each.
80000
-
-
... More
(b) Under Ground Sump 2,000,00 gallons capacity
400000
-
-
... More
(c) Under Ground Sump 1,000,00 gallons capacity
200000
-
-
... More
(d) Under Ground Sump of 25,000 gallons capacity
50000
-
-
... More
(e) OH reservoir upto 50000 gallons capacity
100000
-
-
... More
(fe) OH reservoir upto 1.75 Lakhs gallon capacity
350000
-
-
... More
Water Testing of borewells (8 Nos) and RO Plant -01 Nos at 13 BRD and 16 BRD area on a Quaterly basis by collecting water samples from different locations in the area for the following parameters-Colour,Odour,PH Value,Taste,Turbidity,Total Dissolved Solids,Ammonia,Chloride,Flouride,Free Residual chlorine,Iron,Nitrate,Total AlkalinityTotal Hardness,Lead,Mercury,Total Arsenic,E.Coli,Total Coliform Bacteria.
3
-
-
... More
Supply and fix in replacement of water level indicator of electronic type with PVC insulated copper conuctor for indicating water level.
2
-
-
... More
Supply and fix in replacement of water meter of analog type in 150mm CI pipeline line.
2
-
-
... More
M & L for MS plate /sheet plain or chequered, cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding all as directed and specified.
250
-
-
... More
Taking down cast iron /DI/GI water mains including burning out joints and recovering lead size of bore 150mm complete all as specified & directed by Engineer-in-charge.
210
-
-
... More
Taking down cast iron water mains including burning out joints and recovering lead size of bore 100mm complete all as specified & directed by Engineer-in-charge.
200
-
-
... More
Supplying, and laying and testing in trenches, jointing/ connecting and testing 150mm bore ductile iron pipe class 'k-7' with spigot and socketed ends, centrifugally cast suitable joint complete, all as specified and directed by Engineer-in-Charge.
110
-
-
... More
Supplying, and laying and testing in trenches, jointing/ connecting and testing 100mm bore ductile iron pipe class 'k-7' with spigot and socketed ends, centrifugally cast suitable joint complete, all as specified and directed by Engineer-in-Charge.
100
-
-
... More
Supply, laying, jointing & testing in replacement in trenches cast iron pipes 150 mm bore with spigot and socketed ends centrifugally cast (spun cast) class LA suitable for tyton joints complete all as specified and directed.
Note:- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item.
100
-
-
... More
Supply, laying, jointing & testing in replacement in trenches cast iron pipes 100 mm bore with spigot and socketed ends centrifugally cast (spun cast) class LA suitable for tyton joints complete all as specified.
Note:- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item.
100
-
-
... More
Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in width and getting out complete all as specified and as directed by Engineer-In-Charge.(Note:-Earth work (Item no-1,2,3,4) including excavation/Return filling/Removing is meant for job other than that required in laying of pipes and will be measured and paid for location as on requirement basis)
250
-
-
... More
Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge.
225
-
-
... More
Removing of excavated material/soil to a distance not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 Mtr above the starting point all as directed by Engineer-In-Charge.
20
-
-
... More
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level)
4
-
-
... More
M&L for PCC 1:3:6 type C-1 ( using 20 mm graded stone aggregates) for repairing of valve chamber foundation etc including filling in road cuts/ hard standing etc all as specified and as directed.
4
-
-
... More
Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 50 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed .
200
-
-
... More
Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 40 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
300
-
-
... More
Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 32 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
200
-
-
... More
Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 25 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
400
-
-
... More
Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 25 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
200
-
-
... More
Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 20 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
400
-
-
... More
Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 15 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
200
-
-
... More
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 50 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
5
-
-
... More
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 40 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
5
-
-
... More
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 25 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
6
-
-
... More
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 20 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
6
-
-
... More
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 15 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
6
-
-
... More
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
30
-
-
... More
M&L for complete rewinding of electric motor with super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete. Note :- rewinding shall be done with gurantee during the contract period. Any defects after rewinding shall be rectified by the contractor at his own expanses.
15
-
-
... More
Supply, connection and testing of submersible cable copper conductor 3 core 1100 Volt grade 4 sq mm nominal cross sectional area including disconnecting the old u/s cable complete all as specified and directed by Engr-in-charge.
30
-
-
... More
M&L for Annual maintance contract visit for RO plant capacity 5000 Ltr/hr, at 13 BRD domestic area including servicing, overhauling & repair if any required with replacement of all unserviceable parts complete all as specified and as directed by Engineer-In-Charhe. Note:- The RO plant maintained in serviceable condition through out the contrat period and any complaint regarding unserviceablilty of shall be rectified within 48 hrs panelty @ Rs 2000/- day shall be deducted from contractors dues till rectification on complaint. (A) Comprehensive AMC for RO Plant & its Equipment Capacity 5000 Ltr/hr :- (i) MGF -01 No (ii) Dosing Pump -01 (iii) RO Plant Complete 5000 ltr/hr -01 (B) scope to be covered under AMC :- (i) Provision of training to operate the above System (ii) Submission of the preventive Maintenance Chart for the Month (iii) Cleaning operation for RO Membrane with all consumable/Chemicals (iv) Monthly cheacking of Cartidge, If cartridge shall be required, the supplier will arrange the same (v) Arrangment for probing of RO inter stage once in a month, resetting of 'O' ring in board connector etc to be arranged, if Required (vi) Maintenance/trouble shooting of high pressure pump Necessary spares will be arranged by Suppliers,if Required (vii) Fault detection procon Pump/high prssure pump
9
-
-
... More
(viii) Replacement of on off switches (ix) PVC interconnection pipe line of complete RO system (excluding incoming GI pipe line) (x) Interconnector of Pressure vessel & 'O' ring of connector (xi) Mechanical seal of high Pressure pump (xii) Pressure switches (xii) ball valve size 1'' SS 316 & victaulic coupling 1 1/2'' (xiii) pressure gauge SS 0-7 to 21 kg/sqcm (xiv) U pvc pipes size as per existing sample including aceessories (tee,elbow,socket etc).if any damages replace that items. (xv) The above items shoud be covered AMC Total overall serviceable RO Plant Through contract period.No Extra amount shall be paid govt in this account (C) scope to be covered under AMC :- Annual maintance contract visit for RO plant and fixing and servicing by the items below :- (i) Micron Cartridge - 12 Nos (ii) De-Scaling chemical -60 Kg (iii) Defouling chemical - 60Kg (iv) Anti scalent - 60 Kg (e) Soda Ash - 25 Kg (f) Cleaning Chemical HCL -50 ltr Under AMC (Note : The above items will be measured and paid seperately as supply only). Supplier shall replace all the damaged parts free of cost, but following Damages shall not be Covered under this scheme:- (i) Any Damages caused due to improper operation RO Plant (ii) Damage of electrical parts and damages due to power fluctuations (iii) Damage membranes and procon/ high presure pump. Under AMC, Supplier shall replace all the damaged parts other than supply only items considered hereinafter as supply only, but rest of parts required to keep plant functional around the clock shall be considered in quoted rates.
-
-
-
... More
Note I :- (a) Material shall be supplied in each month (b) Payment shall be made quaterly basis Note II :- 1. Old material will be the property of the department/contractor/credit if any certified that funds are available to meet the cost of expenditure 2. Certified that the above stores/items do not pertain to any original local pruchase items/NAC attached. 3. Certified that stores/repairs and replacements are urgently required and its delay would be detrimental to public services
-
-
-
... More
Supply and fixing in repair membrane suitable for 5000 LPH model -8040 (as per sample) complete all as specified and as directed. Make :- torey/flimtech(DOW)/ION exchange. Note: Membrane has to be change two times of the contracts period , one time at the starting of contract and second time after 06 months and as and when directed) due to high alkanity water.
10
-
-
... More
Supply and fix in repair cartage housing suitable for filter 20''x4'' suitable for RO capacity 5000 LPH including gasket packing etc (as per sample) complete all as specified and as directed.
1
-
-
... More
Supply only media for MGF suitable for RO plant inluding taking out old media and gasket complete all as specified and as directed.
1250
-
-
... More
Supply and fix in repair De-scaling chemical
60
-
-
... More
Supply only refouling chemical
60
-
-
... More
Supply only Antiscalent
60
-
-
... More
Supply only Soda Ash
25
-
-
... More
Supply only cleaning chemical HCL
50
-
-
... More
Labour charges for disconnecting all water pipe connection and taking down the MGF MS tank of weight approx 2000 Kg with the help of chain pully or crane and placed at other site safely
1
-
-
... More
MS 'C' Channel of suitable size including necessary cutting and welding work for base frame
2
-
-
... More
Supply and fixing in replacement of MS ERW pipe C class of 50 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
24
-
-
... More
Supply and fixing in replacement ISI Marked, of approved quality, 150mm size cast iron non butterfly valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement ISI Marked, of approved quality, cast iron 50 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
6
-
-
... More
Supply and fixing cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply and fixing cast iron non return valve with GM sheet and flap of size 150mm bore flanged ISI marked including bolts nuts, washer and rubber gasket etc complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing cast iron non return valve with GM sheet and flap of size 100mm bore flanged ISI marked including bolts nuts, washer and rubber gasket etc complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing in replacement of Heavy duty threaded / welded MS or GI Flange with rubber gasket 50 mm complete all as specified and as directed.
10
-
-
... More
Supply and fix in repair micron cartridge filter of dia 69+-1.5 m and length 10" suitable for RO Plant as and directed
12
-
-
... More
M&L for replacement of U pvc pipes (sch-40) 1.5 inch including aceessories complete all as specified and as directed.
12
-
-
... More
M&L for replacement of U pvc pipes (sch-40) 2 inch including aceessories complete all as specified and as directed.
19
-
-
... More
M&L for replacement of Rota meter suitable for re-circulation line suitable for 5000 LPH RO plant (as per sample) make aster /HP/flow star complete all as specified and as directed.
3
-
-
... More
Supply and fixing in replacement of outdoor waterproof LED glow sign board of dimension 8x4 ft for outdoor installation having aluminium composite panel of 3 mm thickness base with box type frame having complete LED letters fixed on the base of the board with complete heavy duty driver set for LED letters including angle iron of size 40x40x5 mm of suitable length for holding the whole assembly complete all as specified and as directed. Note:- The content of the board will be finalised by Engr in charge.
2
-
-
... More
Taking out existing GI tubing 50mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
200
-
-
... More
Taking out existing GI tubing 40mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
300
-
-
... More
Taking out existing GI tubing 32mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
200
-
-
... More
Taking out existing GI tubing 25mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
800
-
-
... More
Taking out existing GI tubing 20mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
600
-
-
... More
Taking out existing GI tubing 15mm bore with all fittings complete all as specified & directed by Engineer-in-charge.
200
-
-
... More
Refixing and laying 25mm bore in the same location of any height of bldgs after cleaning with de-scaling solution including cutting defective pipe and cutting, threading and repalcement of new fittings such as socket, bend, elbow, union etc. complete all as specified & directed by Engineer-in-charge.
200
-
-
... More
Refixing and laying 20mm bore in the same location of any height of bldgs after cleaning with de-scaling solution including cutting defective pipe and cutting, threading and repalcement of new fittings such as socket, bend, elbow, union etc. complete all as specified & directed by Engineer-in-charge. Note for item No. 41 & 42:- Excavation & earth work shall be measured and paid for separately under appropriate item of this Schedule).
200
-
-
... More
M&L for rectifying leakage of GI pipe line of size 15 to 25 mm including mounting of any height of bldgs by using of hydra and ladder as suitable including disconnection of leakage pipe by cutting it through hakshaw and making thread in existing pipe line by using rachet set and replacement of new fitting such as socket, bend , elbow unior etc. complete all as specified and directed by Engineer-in-Charge. (iii) Leakage to be rectified within 3 hours of report failing which penality @ Rs. 1000/- per hour to be charged for delay.
150
-
-
... More
Supplying, and laying and testing in trenches, jointing/ connecting and testing 150mm bore HDPE pipe complete, all as specified and directed by Engineer-in-Charge.
80
-
-
... More
Taking down HDPE water mains including burning out joints size of bore 150mm complete all as specified & directed by Engineer-in-charge.
80
-
-
... More
Note:- (a) The amount of Rs 175395.00/- against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) Any material required to be replaced for complaint rectification other than screws, PVC rawl plug, nuts & bolts, insulation tape, thimbles and as specified in complaint item shall be measured and paid seperately under respective supply only item. (c) The cost of attending complaints shall also include the cost of stationery required for recording complaint, complaint slips and its reports as directed by Engineer-in-charge. (d) All the complaint registered (except point wiring / sub-main wiring and connected S&F items) before 1000 Hrs of every day shall be rectified on same day upto 1700 Hrs. Any delay in complaint rectification a penalty shall be recovered @ Rs.100/ per complaint per day. (e) The items supplied by contractor as supply only shall be taken on charge by deptt. and shall be issued to contractor's trademen for incorporation against the complaints slips under item No 30 hereinbefore and proper records of same shall be maintained. (f) All T&P required by electrician for complaint rectification shall be provided by the contractor at his own cost. (g) Any disturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements