Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 May 2024
Closing Date5 Jun 2024
Tender Amount₹ 79,95,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.

734

-

-

... More
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.

268

-

-

... More
Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed.

94

-

-

... More
M&L for brick protection with sub class 'B' old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed.

1

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thick (below or above ground level) complete all as specified and directed.

15

-

-

... More
Demolition of reinforced cement concrete (RCC) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.

1

-

-

... More
Dismantling of brick work, built in cement mortar or lime mortar including all quoins, arches, pillars, etc., but excuding ashlar facings, dressed stonework and precast concrete articles, complete in all respect as specified and directed.

2

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete in all respect all as specified and directed.

15

-

-

... More
Taking down cement mortar plaster on brick or stone wall or concrete surfaces etc., including raking out joints, hacking for key, scrubbing down with water etc. complete in all respect as specified and directed.

165

-

-

... More
Taking down chowkats or frames and shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each, complete in all respect as specified and directed.

4

-

-

... More
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete in all respect as specified and as directed by Engr-in-Charge.

100

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed

5

-

-

... More
Taking up or down cable XLPE insulated cable from the tranches including removing from the site all as specified and as directed. Note:- The Photographic Evidence of the same shall be kept on record and shall be fwd to Office of Accepting Officer duly time stamped.

2290

-

-

... More
Excavation in post holes (or similar holes) in soft/loose soil each not exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50 m and making good surface.

4

-

-

... More
Sch 'A' - Part-I (B/R Work)

-

-

-

... More
Providing and laying in position cement concrete of in foundation, filling and mass concrete, sub-base to flooringType D2, 1:4:8 ( 40 mm graded aggregate ) complete all as specifed and directed

6

-

-

... More
M&L for Brick work with sub-Class ‘B’ bricks (with old size bricks), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6, complete all as specified and as directed.

7

-

-

... More
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) in coping including necessary form work etc.complete all as specified and directed.

1.5

-

-

... More
S&F mild steel work in plates (plain or chequered) channels, squares cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, complete in all respect as specified and directed.

1870

-

-

... More
M & L for mild steel iron frame for door, window using joist, channel, angle, tee, tubes, flat sections, fixed independently, without connecting plates, etc. Fe 410 -W (Gde-E- 250) quality-A complete in all respect as specifified and directed.

190

-

-

... More
M & L preparation of new surfaces of steel and iron work of any description over 10 cm width or girth and applying two coat of synthetic enamel paint of approved texture over and including a coat of primer etc complete all as specified and as directed.

100

-

-

... More
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.

60

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Note-The Contractor shall submit Purchase Voucher for claiming payment. The Engr-in-Charge shall fwd the defaced voucher along with RAR. Non-Submission may lead to non-Payment of RAR/Final Bill

7

-

-

... More
M&L providing 50 mm thick cement concrete type B0,1:2:4 (12.5mm graded aggregate) as in floor finish complete all as specified and as directed.

120

-

-

... More
Material and labour for First quality Non-skid Ceramic coloured tiles jointless, 7-8 mm thick (area of each tile exceeding 0.09 Sqm but not exceeding 0.16 Sqm) laid in floors with neat cement slurry @ 3Kg/Sqm over and including 15mm thick screed bed of cement mortar (1:6) and including pointing in white cement with pigment to match the shade of tiles including dismantling of floor, hearth or wall tiling including cemetn mortar bedding including removing from the premises complete all as specified and directed.

120

-

-

... More
M&L for cement concrete work in pavement hard standing of flexural strenght 40 Kg/ per sqcm in field using 400 kg of cement per cum, thickness of concrete 10 cm, complete in all respect as specified and as directed.

3

-

-

... More
M&L for brick work with sub-class "B" old size bricks of class designation (CD) 75, straight or curved on plan to any radius in half brick thick walls built in cement mortar (CM) 1:6, complete in all respect as specified and directed.

20

-

-

... More
M&L for 15 mm thick cement plaster in CM 1:4 on brick or concrete surfaces of drain incl finished the surfaces even and smooth without using extra cement complete all as specified and directed.

130

-

-

... More
M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete in all respect as specifified and directed.

140

-

-

... More
M&L for preparation of newly plastered surface of wall and applying two coats of dismper oil emulsion over and including wall care putty of thickness avg 1.00mm complete in all respect as specified and directed. Notes : all holes/ cracks to be filled with birla putty and making good to old surface shall be incuded in the quoted rate

140

-

-

... More
M&L for two coats of cement base paint on newly plstered surface over and including a coat of chalk whiting including all prepration, complete in all respect as specified and as directed.

50

-

-

... More
M&L for preparation of new plastered surfaces of wall and applying two coats of white wash over and including a coat of chalk whitening complete all as specified and directed.

80

-

-

... More
Providing and fixing aluminium work for frame/shutter/fixed portions of doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per specified and directed. (Glazing, paneling to be paid for separately) : (Mim Thickness of Section shall not be less than 1.5 mm)((minimum thickness of powder coating 50 micron) NOTE:- The purchase Voucher of Alumnium Section shall be submitted for claiming payment. Non Submission may lead to non payment

100

-

-

... More
S&F float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) figured pin headed type, best quality, fixing to Steel Sections as in Panel of Doors/ Windows Shutters and Panelling Works with necessary fixing Arrangements viz Jointing Cleats, Glazing Clips, Rubber Packing, Screws, etc. or fixed with Oil Putty, as required/ordered at Site(s), complete and fixed all as specified and as directed. NOTE:- The purchase Voucher of Float Glass shall be submitted for claiming payment. Non Submission may lead to non payment

21

-

-

... More
Providing and fixing double action hydraulic floor spring With stainless steel cover plate minimum 1.25 mm thickness of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. NOTE:- The purchase Voucher of Door Closure shall be submitted for claiming payment. Non Submission may lead to non payment

4

-

-

... More
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.

4

-

-

... More
Providing and fixing aluminium hanging floor Twin rubber door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified and directed.

4

-

-

... More
Providing & fixing false ceiling With fully perforated 12mm thick micro tegular edged at all heights with GRG ( Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture,design and patters having moisture content lessthan 2%. Humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS 476 (part4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15x32mm of length 3000mm,cross-T of size 15x32 of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600mm to from grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvenizing @ 80 grams per sqm)i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm lenght and L shape level adjuster of size 85x25x2mm Galvenised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work complete in all respect as per specifications, drawing and as per directions of the Engineer-in-charge NOTE:- (i) The purchase Voucher of False ceiling shall be submitted for claiming payment. Non Submission may lead to non payment (ii) The Sample approval shall be based on the Matching specification of BoQ item

100

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete all as specified and as directed.

12

-

-

... More
M&L for preparation of newly undecorated plastered Surfaces of any description over 10cm girth or width, not otherwise described of wall and applying two coats of black Bituminous Paint over and including one coat of priming paint plaster coat complete in all respect as specified and directed. (Notes : all holes/ cracks to be filled with birla putty and making good to old surface)

70

-

-

... More
S&F Mechanical compactor of CRAC TATA sheet having 20 guage body & 20 guage of shelf with powder coated body, adjustable shelf center locking heavy duly and durable tracks and ergonomically designed handles, size 1980 Hx900 Wx400 D mm for single face fixed and single face moblile as well and 190x800x900mm for double face mobile unit complete all as specife Note: (i)The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment (ii) The work shall be executed through authorised Rep

2

-

-

... More
S&F ESD safe revolving Chair complete all as specified and directed. Note: (i)The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment

5

-

-

... More
S&F ESD safe bench of 6 feet by 3 feet complete all as specified and directed. Note: (i)The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment

5

-

-

... More
Sch 'A' - Part-I (E/M Work)

-

-

-

... More
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core complete all as specified and directed

100

-

-

... More
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sq mm complete all as specified and directed

2290

-

-

... More
NOTE for Item no. 3.01 to 3.02 (i) The cable shall be directly purchased from the Approved Cable Manufature or from his authorised dealer. The Make shall be approved by GE on recommendation of Engr-in-Charge. The Authorised dealer of Manufature shall got verified by Engr-in-charge before placing the bulk order. (ii) The contractor shall submit Purchase Voucher of each type of Cable. The Engr-in-Charge shall allow payment only after verification of voucher and De-facing of the orginal voucher. Non-submission may lead to non-payment. (iii) All the cable shall got indepent testing at site in presence of Engr-in-Charge, rep of contrator as per IS code. The report shall be made and signed by all the parties. The copy of report shall be fwd to office of Accepting Officer before laying of cable. (iv) The contractor shall submit Manufature Test Certificate during sample approval.

-

-

-

... More
Supply, Installation,Testing and Commisioning of waterless maintenance free earthing based on pre-casted conductive earthing electrode dimensions lengthx dia.: 10000x80 using 17.2 mm solid conductors upto bore depth level with copper bonded terminals, lugs and latches. Conduction : Non Ionic movement of ions with multipoint dissipitaion contacts exceeds grade 25 concrete with Ph neutral internal material with eco friendly having relative density of 890-990 kg/m3. Earthing is having 3000 times more effective than Bentonite. The earthing electrolytic corrosion resistance is 86% reduction in corrosion with short circuit current: Peak: 40 KA RMS: 22 Kilo amps fro 1 second also having mechanical strength of grade 25 concrete. Th earthing high fault current test withstand of 1686 V for 500ms. The earthing standards as per IEEE 80:2000 & BS 7430, Resistance value is less than 1 ohm. The heavy duty earth pit cover will be provided. Waranty 3 years.

1

-

-

... More
Supply & fix 2 Mtr SS Single Phase Air Curtain with Flame Proof limit switch with air flow 18m/sec (18 Mt/sec Velocity at nozzle and 4m/sec velocity at bottom) for suitable door height of 3200 mm one Single Phase 2A2BclassF FLP motor 1/2 H.P 220 V, 50 Hz (RPM-1440) with SS-22 guage Blower, SS-18 gauge Outer Cabinet, SS Side covers, MS-14gauge Hanging bracket and SS-18guage Louver & Grill. The CFM is 6415 with velocity at bottom is 4 m/sec with SS-20gauge side covers. The Air outlet area of Air curtain is (75mm*435mm)*2Louver with Air suction area 195mm*1950mm with Noise level less than 75 decibel at a distance of 1 metre complete all as specified and directed Note- (i) The items required for fitting of Air Curtain like nut, bolt, steel plate, wooden plate, wall cutting/plastering includes in this item. The connection FRLS PVC insulated copper cable of size not less than 1.5sqmm and length of copper conductor not more than 10 m from DB includes in this item (ii) The contractor shall submit purchse voucher for claiming payment. The Engr-in-Charge shall submit the PV duly defaced and verified at the time of payment. Non-submission may lead to non-payment. (iii) MAKE: Almonard, Aircon, National or equivalen ISI marked

2

-

-

... More
Supply, Installation, Testing and Commissioning of Digital earthing system/device comprising of energy conversio unit, neutralization unit, digital analysis unit, ground connection unit MGB, surge detection & discharge unit and lightening protection unit (Basd of ECA3G Technology), Material copper Frequency 50 Hz, Supply 230 V, Display-LCD, Operating Temp-40 to 80 Degree built in surge counter. Ensuring less than 01 V earth to neutral voltage and grounding impedance less than Ohm with self protective, self operated and fully autonomous aerosol based fire extinguser product NOTE:- (i) The Work shall be executed through authorised rep. (ii) The Engr-in-Chrge shall carry out Factory inspection, if possible and forward the report to Accepting Officer. (iii) The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment (iv) The Contractor shall submit Warranty certificate for 05 (Five) years. An Amount of 05 % of this BoQ item shall be retained for Five years from the Date of Completion of work.

3

-

-

... More
S&F Copper strip ( PVC Insulated sleeves) of size 25 width x 06 mm thick as in earth continuity conductor fixed to wall or buried in ground or any other situation for loop earthing as required at site

130

-

-

... More
M&L for sub main wiring of four run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-and-caping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including two run of 6.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.

50

-

-

... More
M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-and-caping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.

40

-

-

... More
M&L for point wiring for 15 Amp switch socket for power point complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing-n- copping and its accessories, cadmium screws and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing the specified and directed.

19

-

-

... More
Supply, Installation, Testing and Commissioning of 80 ltr capacity Dehumidifier range :25%-60%, Input voltage :110-220V AC/5V 2A ,DC” Power : 5W/H, one Quantity of Controller PC , LCD Display and 2 foot height Adjustment system complete all as specified and directed, NOTE:- The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment MAKE-Honey well/ Indfoss/ Ramco make or as equivalent

2

-

-

... More
Supply & fix sheet metal enclosure for 415 volts IP40-32 Amps with 3phase ,Neutral and earth including industrial type three pin and earth plug top with socket complete as well as specified and directed.(MCB will be measured and paid separeately)

3

-

-

... More
Supply & fix sheet metal enclosure for 220 volts 20 Amps with a three pin and earth plug top with socket and one double pole MCB 20 amps complete as well as specified and directed.

3

-

-

... More
S&F TPN 415 Volts 4 way double door type DB complete all as specified and directed.

2

-

-

... More
S & F MCB TPN 63 Amps, 415 Volt, 10 KA, 'C' series type complete all as specified and as directed.

2

-

-

... More
S & F MCB TPN 32 Amps, 415 Volt, 10 KA, 'C' series type complete all as specified and as directed.

6

-

-

... More
S & F MCB SP 6-32 Amps, 240 Volt, 10 KA, 'B' series type complete all as specified and as directed.

12

-

-

... More
S&F twin socket modular type heavyduty out let 6 pin 6/16 Amps 2 module complete all as specified and directed

19

-

-

... More
S&F switch Modular type 16 Amps , single pole one way 240 volts one module as specified.

19

-

-

... More
Material and labour for HT Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed

2

-

-

... More
Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed

8

-

-

... More
Supply and laying factory made reinforced precast concreate cable cover, class EHV , type-1 with Peak size 450mm x 230mm x 50 mm for HT cable protection complete all as specifed and directed. Note:- The Contractor shall submit Purchase Voucher for claiming Payment. The Engr-in-Charge shall verify the voucher and attach with RAR/Final bill duly defaced and entry in MB. Non-submission may lead to non-payment

9

-

-

... More
M&L complete for drilling hole manually under hard standing /road for laying of pipe for protection of cable etc and making good the disturbed surface to the existing if any, complete all as specified and directed by Engineer-in-Charge.

48

-

-

... More
Supply and laying GI tube light grade 100 mm bore pipe with ISI marked fittings complete all as specified and directed by Engineer-in-Charge.

48

-

-

... More
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates for repairing / filling in road cuts/ hard standing etc all as specified and as directed.

3

-

-

... More
Schedule of Credit

-

-600570

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.