Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_655765_1Bid Award Id
ViewTender No
GE(SOUTH)/AMB-04/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fixing in repair hanging assymbly set comprising with rubber reel, mild steel clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
200
-
-
... More
Material and labour for painting of ceiling fan using synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour complete all as specified and directed.
200
-
-
... More
Material and labour for hanging only ceiling fan any type/ sweep after repair and connecting up including provision of three core PVC insulated and unsheathed copper conductor cable of size 0.5 Sqmm from ceiling rose to connector to fan including refixing of blades complete all as specified and directed.
390
-
-
... More
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed.
NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engineer-in-charge and cost of cutting of winding shall be included in the quoted rate.
(ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
320
-
-
... More
Material and labour for taking down exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed.
90
-
-
... More
Material and labour for rewinding of exhaust fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed.
NOTE for item No 2,3 and 8 to 11 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engineer-in-charge and cost of cutting of winding shall be included in the quoted rate.
(ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
50
-
-
... More
Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed.
30
-
-
... More
Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc complete all as specified and directed.
90
-
-
... More
Supply and fixing of heavy duty, plastic body exhaust fan, AC singal phase, 240 volts of size 250 mm sweep with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed.
25
-
-
... More
Taking down old unserviceable geyser of capacity 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.
(b) Examine any water leakage from geyser/storage tank.
(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.
(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.
(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ as "Supply only".
250
-
-
... More
Taking down old unserviceable geyser of capacity 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.
(b) Examine any water leakage from geyser/storage tank.
(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.
(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.
(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
10
-
-
... More
Supply only heating element of capacity 2 KW of geysers of any make ISI marked complete all as specified and directed.
220
-
-
... More
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed.
170
-
-
... More
Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed.
100
-
-
... More
Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed.
10
-
-
... More
Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete as an directed.
200
-
-
... More
Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed.
70
-
-
... More
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed.
50
-
-
... More
Supply only geyser storage inner tank made out stainless steel sheet as per sample suitable for 25 ltrs capacity complete all as specified and directed.y
30
-
-
... More
Supply only geyser storage inner tank made out stainless steel sheet as per sample sheet suitable for 50 ltrs capacity complete all as specified and directed.
5
-
-
... More
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed.
25
-
-
... More
Supply only PVC insulated, unsheathed cable 2.5Sqmm 3 core 1100 volt gradewith multistranded copper conductor complete all as specified and directed.
90
-
-
... More
Supply and fixing of in repair of sheet metal enclosure SP with two pin and earth plug and socket including top with one single pole, MCB 20/32 Amps, 'B' curve, 240 volts complete all as specified and directed.
40
-
-
... More
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
1430
-
-
... More
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.
NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
850
-
-
... More
Description all as per item No 28.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
100
-
-
... More
Description all as per item No 28.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
100
-
-
... More
Description all as per srl item No 28.00 above but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
70
-
-
... More
Supply and fixing of modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
1025
-
-
... More
Supply and fixing of modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
70
-
-
... More
Supply and fixing of modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
200
-
-
... More
Supply and fixing of modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed.
70
-
-
... More
Supply and fixing of fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed.
60
-
-
... More
Supply and fixing of modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
25
-
-
... More
Supply and fixing of modular blanking plate 1 module complete all as specified and directed.
50
-
-
... More
Material and labour for concealed point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH accessories, concealed and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch complete all as specified and directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
200
-
-
... More
Description all as per item No 39.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
40
-
-
... More
Description all as per item No 39.00 above but for socket out let point 5 Amps on independent board,complete all as specified and directed.
40
-
-
... More
Description all as per item No 39.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
30
-
-
... More
Supply and fixing of switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
270
-
-
... More
Supply and fixing of switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
30
-
-
... More
Supply and fixing of bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
10
-
-
... More
Supply and fixing of socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
80
-
-
... More
Supply and fixing of socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and directed.
30
-
-
... More
Supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
700
-
-
... More
Supply and fixing of fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
30
-
-
... More
Supply and fixing of door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
40
-
-
... More
Material and labour for taking down existing light fitting i.e. tube light surface ceiling light, flame proof light etc any type / size/make / capacity and refix the same after minor repair/ cleaning including replacement of connection wire with 0.75sqmm copper wire twin core for connection from ceiling rose to light fitting all as specified and directed.
100
-
-
... More
Supply and fixing of LED light fitting 1 x 20W, 220V, AC with aluminium housing with batten type with driver, holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
550
-
-
... More
Supply and fixing of channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. (Tube rod shall be measured and paid for separately). Note: - Channel must be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact.
450
-
-
... More
Supply and fixing of 18 Watt / 20 Watt LED tube light two end contact, fitting should have lumen output more than 100 lumens per watt, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. NOTE: - Tube rod must be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
720
-
-
... More
Supply and fixing of batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
150
-
-
... More
Supply and fixing of LED bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed.
50
-
-
... More
Supply and fixing in repair bracket for security light made up of 25/40 mm dia, 0.60 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
40
-
-
... More
Supply and fixing of LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
12
-
-
... More
Supply and fixing of LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
11
-
-
... More
Supply and fixing of inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
30
-
-
... More
Supply and fixing of post top lantern LED 30 Watt cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. NOTE : - LED (Cool white or warm white) must get approved by Engineer-in-Charge.
20
-
-
... More
Disconnecting and taking down old existing Bollard light fitting of any description and in any position and supply and fixing LED bollard light fittings with aluminium pipe housing swith glare fee PMMA diffuser , IP 65 protection ofheight not less than 600 mm with and including 10 watt LED including base frame made up of sheet metal and connecting up with three core 1.5 sqmm flexible copper conductor cable including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed. NOTE : LED (Cool white or warm white) must get approved from Engineer-in-Charge.
22
-
-
... More
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
150
-
-
... More
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
210
-
-
... More
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.0 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
450
-
-
... More
Material and labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and as directed. NOTE:- (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item.
(ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
42
-
-
... More
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 125 Amps, 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
5
-
-
... More
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 100 Amps, 16 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
5
-
-
... More
Supply, installation, testing of SPN distibution board 8 way,double door , IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
40
-
-
... More
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
300
-
-
... More
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
55
-
-
... More
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz, breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
55
-
-
... More
Supply and fixing in repair of MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal adjustable type complete all as specified and as directed.
5
-
-
... More
Supply and fixing in repair of MCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal adjustable type complete all as specified and as directed.
5
-
-
... More
Supply and fixing in repair of PCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep, single phase, 240 V complete all as specified and directed.
63
-
-
... More
Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
180
-
-
... More
Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 16 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
180
-
-
... More
Material and labour for taking down existing light fitting of any type alongwith GI pipe/ pole of any dia upto 2 mtr height and supply and fixing of MS pipe (Hot dipped Galvanized) decorative pole in two sections i.e Top pipe not less than 75 mm outside dia x 1500 mm long and Bottom pipe not less than 110mm outside dia x 500 mm long, thickness of pipe not less than 3 mm with base plate 250 x 250 x 12mm thick having 14mm dia hole for fixing of foundation 'J' bolts of size 12mm dia x 450 mm "J" including 115 x 200 mm long utility window in pole, fixing of suitable size nuts/bolts and washers including Tripple layer metallic PU paint (Etching, Epoxy & PU) suitable for and alongwith 35 Watt Warm white LED post top lantern IP 65 environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs clear cover offers bright illumination including all fixing accessoreis including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed.
Note : (i) Quoted rates shall be inclusive of excavation, taking down existing pole, all fixing acessories & PCC 1:3:6 for fixing of pole & post top lantern.
(ii) Drawing of pole must get approved before installation..
(iii) MS pipe of pole (Top & Bottom) should be ISI marked as per latest standard.
18
-
-
... More
Supply, laying and testing of cable XLPE insulated, armoured heavy duty electric cable with standred aluminium conductor, 1100 volts grade, cross-sectional area of size 10 Sqmm 2 core including dismantling existing any type and any size cable complete all as specified and directed.
520
-
-
... More
Supply and fixing of GI protection pipe of 40mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed.
61
-
-
... More
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, laying of cable etc not exceeding 10 Square metre on plan and getting out in soft/loose soil complete all as specified and directed.
100
-
-
... More
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft/loose soil after cables/pipes etc are laid and tested complete all as specified and directed.
56
-
-
... More
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
44
-
-
... More
Material and labour for supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
28
-
-
... More
Material and labour for brick protection covers over cable using sub class B old size brick laid along length of cable complete all as specified and directed.
3
-
-
... More
Disconnecting and taking down old existing wall fitting of any description and in any position and supply and fixing aesthetically designed wall bracket light in B22 holder with 9 watt LED lamp warm white & clear diffuser including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
88
-
-
... More
Disconnecting and taking down old existing recess/surface mounting ceiling light fitting of any description and in any position and supply and fixing surface/ recess mounting LED slim square/round down lighter 12 W LED with high efficient LEDs glare free opal diffuser madeup of PDC AL with IP 20 Protection including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
50
-
-
... More
NOTE:- Amount of credit of Rs. 1,13,465.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-