Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 92,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693799_1Tender No
CWE/AMB/UTILITY-50 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and laying un-reinforced precast cement concrete cable cover, class HV, Type 1, with peak, size 300mm x 180 mm x 40 mm, complete, all as specified and as directed.
1500
-
-
... More
Supply and erecting prestressed concrete pole 11.0 mtr long in true vertical position 152x152 mm at top and 152x260 mm at bottom, class -9, conforming to IS-1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable PCC HT pole complete all as specified and as directed. NOTE:- Excavation, earth work, PCC work, channel, clamps, nuts, bolts etc shall be measured and paid separately.
5
-
-
... More
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) conforming to IS-1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable steel tubular HT pole complete all as specified and directed. Note: Excavation and earth wok and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately.
15
-
-
... More
Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed.
2.5
-
-
... More
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed.
16
-
-
... More
Material and labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed.
3
-
-
... More
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick of any description, complete, all as specified and as directed.
77
-
-
... More
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete, all as specified and as directed.
79.5
-
-
... More
Supply and fixing in replacement of GI tubing, 80mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed.
36
-
-
... More
Supply and fixing in replacement of GI tubing, 100mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed.
30
-
-
... More
Supply and fixing in replacement of GI tubing, 150mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of danger notice plate 1.60 mm thick of size 25x20 cm, mild steel sheet, vitreous enameled red colour, with letters, figures and conventional skull and bones in signal white colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, complete, all as specified and as directed.
23
-
-
... More
Supply, installing, testing and commissioning of air break gang operated triple switch (GODO) outdoor type, vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators, ISI marked mechanically operated, mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection and dismantling and taking down of old unserviceable GOD complete all as specified and directed.
15
-
-
... More
Material and labour in replacement of lightning arrester expulsion type, suitable for 11000 Volt, with all fittings, trasmission class, discharge capacity 65 KA including connecting with HT line and dismantling and taking down of old unserviceable lightning arrester complete all as specified and as directed.
29
-
-
... More
Material and labour for aluminium conductor steel reinforced (ACSR) weasel/squirrel conductor from 66 KV sub station and other areas, including fixing, stretching on poles and proper noseling with binding wire to insulator of any size on 11 KV OH line as required at site and dismantling and taking down of old unserviceable ACSR conductor complete all as specified directed.
3.8
-
-
... More
Taking out old unserviceable earthing material and provision of new earthing complete with galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 4.00 mm wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering, protection pipe, funnel, wire mesh, RCC cover etc, complete, all as specified or indicated and as directed including testing on completion.
18
-
-
... More
Taking out old unserviceable earthing material and provision of new earthing complete galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering and 40mm GI protection pipe, funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion.
16
-
-
... More
Taking out old unserviceable earthing material and provision of new earthing complete copper plate electrode 600mm x 600mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 20x3 mm copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 32mm dia (medium grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering and 40mm GI protection pipe, funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion.
Notes for Item Nos 19 to 21 : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire wesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in PCC.
(iii) On testing after completion if the desired earth resistance is more than 2 ohm the earthing will be redone at no extra cost.
4
-
-
... More
Dismantling and taking down of old unserviceable cross arms, clamps, bracing, etc. of any section from pole including nuts, bolts, washers and cutting of bolts (slag bolts) if required complete and material and labour for new cross arm bracing supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide primer complete, all as specified and as directed.
5.2
-
-
... More
Supply and fixing pin type, porcelain, vitreous, white or brown or green insulators,11000 volts grade of 150 mm dia, 150 mm height including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts and dismantling and taking down of old unserviceable insulators complete all as specified and as directed.
60
-
-
... More
Supply and fixing disc type insulators, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductor, working pressure 11000 volts grade, and dismantling and taking down of old unserviceable insulators complete all as specified and as directed.
40
-
-
... More
Supply and fixing of stay assembly complete with all accessories such as stay plate 300mmx300mmx6mm, stay rod 20 mm dia and 215cm long threaded end with nuts including 14mm dia GI stay bow. turn buckle, etc. complete, all as shown in Electrical plate No 1 of SSR part I 2009 complete including dismantling and taking down of old unserviceable stay assembly all as specified and as directed. Note- The quoted rate shall include the cost of loop type insulator, stay clamps, excavation, PCC, stay wire, stay bow, turn buckle, nuts etc., excavation, demolition and removal of demolished concrete outside defence land complete.
12
-
-
... More
Supply only in replacement of silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 66 kV / 11 KV stations complete as per site requirement complete, all as specified and as directed.
25
-
-
... More
Material and labour for detecting of fault in UG cable with fault locator equipment which is capable to supply as per cable of (11 KV/430 volts) serviceable to cable complete all as specified and directed. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item. (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality of Rs 500/- per day shall be levied. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting, joint making joint will be paid under relevant item.
19
-
-
... More
Supply and fixing of self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage complete, all as specified and as directed.
200
-
-
... More
Material and labour for Boaring of holes under road, pavement, hard standing of any material and description, by trench less technology using ultra sound technique or manual boring including providing HDPE pipe of 80-150mm dia suitable for 0.4 mpa working pressure complete, all as specified and as directed.
Note:- Boring depth as decided by Engineer-in-Charge.Material and labour for augering of hole of suitable dia & providing heavy duty HDPE pipe of size 80-150mm dia in true horizontal drill under existing National Highway, road and railway track, buildings comlpete all as directed by Engineer-in-charge.NOTE:- (i) The auguring of horizontal hole will be carried out through trenchless horizontal boring machine as shown in site plan.(ii) the cost of HDPE pipe machinery ,transportation,DG Set etc included in the rate quoted.(iii) The boring will be carried out upto 03 mtr deep below the railway track ground level and NH 1 A line cost of excavation of working space as both side of trenchless boring will be deemed to be included in the rate quoted. (iv) while carrying out the work below railway track and NH 1 A , the contractor will adhere to instruction issued by the respective authority. The work will be carried out of at such places under the supervision of MES and Railway/ Highway authirities. (v) Any damage of other property like sewage pipes, other cables , water pipes etc will be repaired/replaced under this item without extra cost , department will not responsible of any damage.
20
-
-
... More
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 95 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.
(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately).
220
-
-
... More
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 120 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.
(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately).
100
-
-
... More
Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 185 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.
(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately).
100
-
-
... More
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl taking down old unsv HT joint complete all as specified and directed .
14
-
-
... More
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm incl taking down old unsv HT joint complete all as specified and directed .
5
-
-
... More
M&L for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 50-95 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified and directed .
14
-
-
... More
M&L for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 120-185 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified and directed .
8
-
-
... More
Taking down old unserviciable cable route board and supply and fixing of Retro reflective sign cable route board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 40mm X 40mm X 5mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed.
NOTE:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
30
-
-
... More
Material and labour for cable route indicator showing "MES HT UG 11 KV" and route of cable with arrow (should be embossed or engraved) made of RCC in suitable shape and fixed in PCC block 1:3:6 type C-2 using 40mm graded aggregate) 60cm xz 30cm in ground, 30cm below ground level and 30cm above ground level to show clear indication of cable including painting the complete slab with red paint and making the engraved/embossed letters/arrows with white paint, complete all as specified and as directed.
25
-
-
... More
Material and labour for shifting heavy items /excavating /cleaning areas /clearing site by providing crane/hydra/excavators as required at site complete all as specified and as directed.
Note:- (i) Before submitting claims for payment under this item, the contractor shall provide detailed documentation for the deployed equipment like Purchase Invoice, Ownership Proof, Registration Certificate (RC), Insurance Details etc.
(ii) The Engineer-In-Charge shall maintain a logbook showing information like execution activities, date, time etc in order to esblish the actual duration of running of equipment and subsequent entry in the MB.
15
-
-
... More
Material and labour for for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders including leveling and spreading lime stone powder under stones complete all as specified and as directed. (Spreaded thickness of filling shall be measured for the purpose of payment)
25
-
-
... More
Material and labour for prepration of old concrete surface of HT poles, 11 metres high including PCC coping, removing old paint particles and apply two coats of cement base paint on the surface of pole and PCC coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 mtr above the coping of pole starting with black strip complete, all as specified and directed.
Note. (i) The quoted rate shall include marking of numbers on each HT pole as per direction of Engr-in-Charge. (ii) The quoted rates includes the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement.
120
-
-
... More
Material and Labour for prepration of old steel surface of HT poles, 11 metres high including PCC coping, removing old paint particles and apply two coats of synthetic paint on the surface of pole and two coat of cement base paint on surface of PCC coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 metre above the copping of pole starting with black strip complete, all as specified and directed.
Note. (i) The quoted rate shall include marking of numbers on each HT pole as per direction of Engr-in-Charge. (ii) The quoted rate include the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement.
100
-
-
... More
Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for lectrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 10m x 1m complete all as specified and diercted.
2
-
-
... More
Material and labour for calibration of VCBs relay by injecting high voltage through CTs checking the over load system of VCB upto 90% rated load and artificial fault creation and setting of relay by 10 to 15% of rated load removing unseviceable overload and earth fault relay including connections with power pack, opening out the trolley, checking the operation of VCB mechanically and electrically through shunt trip coil includng energizing of automatically, checking of TNC switch including testing and commissioning complete all as specified and directed.
Note :- Calibration to be carried out by authorised person and test certificate shall be furnished
15
-
-
... More
Taking out the HT 11 KV metalclad Vaccum circuit breaker of capacity 630A/1250 A, 11000 volts,3 ph, 50 Hz, 350 MVA of any make and type from the cubical panel, for repairs/overhauling and servicing including replacement of wornout parts comprising the following works (a) Removing the complete fixed contacts, moving contacts, cleaninig the contacts, removing the fittings and fixing back to the breakers after adjusting the pressure.
(b) Checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation. (c) Check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc. The labour charges are deemed to be included in the quoted unit rate for this item.
Note (i) Servicing shall be performed by authorised service personnel of OEM i.e M/s ABB/Seimens. (ii) Servicing certficate shall be provided to engineer-in-charge. (iii) Replacement of minor spares like Push button lever, Green push button, red push buttons and shaft for operating handles etc. are inclusive of rate quoted by tenderer (iv) Measurment of resistance value, tools, labour, petroleum jelly are incl in this quoted rates (v) Part will be replaced under relevent items.
15
-
-
... More
Material and labour for highly HT insulating opaque red coloured ANTI TRACK COMPOUND SPRAY 320 of MOSIL LUBICANTS that forms flexible chemical resistant coating to class H winding for electrical apparatus, in 500 ml spray bottles to protect HT equipments, bus bar, CTs, PTs from current leakage due to moisture complete all as specified and as directed.
20
-
-
... More
Material and labour for Danment Chemical spray (DC2.26 having container 415ml/
300g) for precision blended multipurpose product to protect HT equipments from corrosion due to moisture complete all as specified and as directed.
Make : Danmet Chemical Pvt Ltd or equivalent as specified.
20
-
-
... More
Material and labour for spraying chemical (roundup) on area to remove unwanted vegitation/ grass at various locations as directed by Engr-in-Charge Note : (i) Labour and equipments required to spray chemical on required area are included in the quoted rates. (ii) Spray shall be repeated quarterly all as per direction of Engr-in-Charge.
(iii) Purchase voucher of chemical brought at site shall be inspected and entered in MB as per instructions laid down for propreitory articles.
50
-
-
... More
Supply and fixing in replacement of Pole assembly (vacuum interrupter bottle assembly) complete Breaker of ABB suitable for fixing in Sector 'B' substation complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement of vacuum interrupter pulling rod suitable for ABB/Siemens suitable breaker for existing model for fixing in 66KV/11KV substations complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of unserviceable spout of VCB panel for suitable model from HT panel ABB/Seimens of 11 KV substations complete, all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of unserviceable spout contant of VCB panel for suitable model from HT panel ABB/Seimens of 11 KV substations complete, all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of housing of Pole assembly for ABB/Seimens suitable model Breaker from HT panel of 11 KV substations, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of unserviceable Strip heaters 100 Watt, AC 240 Volts from HT panel of 11 KV substations complete all as specified and directed.
15
-
-
... More
Supply and fixing in replacement of unserviceable thermostat from HT panel of 11 KV substations complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of unserviceable Strip heaters 80 Watt from HT panel of 11 KV substations complete all as specified and directed.
15
-
-
... More
Supply and fixing in replacement of unserviceable indicator with complete wiring of red/green/yellow colour from HT panel of 11 KV substations complete all as specified and as directed.
35
-
-
... More
Supply and fixing in replacement Potential transformer (PT) of rating 11000/110V size and model as suitable for existing PTs installed at 11 KV substations including re-wiring and testing complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement current transformer of rating 500-250/5A of size and model as suitable for existing CTs installed at 11 KV Sub stations including re-wiring and testing complete, all as specified and directed.
1
-
-
... More
Supply and fixing in replacement current transformer of rating 200-100/5A of size and model as suitable for existing CTs installed at 11 KV Sub stations including re-wiring and testing complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of shunt closing release coil 24 V/110V DC/AC suitable for 12 KV 1250 A 31.5 KA VCBs for suitable model of Make ABB//Seimens/Schneider complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of Geared motor (EL)220-250 V AC/DC suitable for 12 KV 1250 A 31.5 KA VCBs for suitable model of Make ABB//Seimens/Schneider complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of unserviceable limit switch for spring charging motor for suitable model of Make ABB//Seimens/Schneider HT panel of 11 KV substations complete all as specified and as directed.
5
-
-
... More
Supply and fixing in replacement of tripping coil 24 Volt DC suitable for 12 KV 1250 A 31.5 KA VCBs for suitable model of Make ABB//Seimens/Schneider complete all as specified and directed.
5
-
-
... More
Supply and fixing in replacement of racking mechanism to restrict uncessary blocking of trolley arrangement for suitable model of ABB/Siemens breaker complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of tulip contacts 08/12 fingers of circuit breaker for suitable model of ABB/Siemens circuit breaker complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of TNC switch for VCBs at different 11 KV substations complete all as specified and directed.
4
-
-
... More
Supply and fixing in repair PT Fuse of capacity 11 KV suitable to fit on existing PTs in 11 KV incommer VCBs at various substations under GE (U) Ambala complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of combined overcurrent and earth fault relay REJ601/7SR1205 of Make ABB/Siemens including fixing in HT panels at 66 KV MRS and 11 KV substations with connections as per company diagram from OEM complete all as specified and as directed.
2
-
-
... More
Supply and fixing in replacement of master tripping relay of auxillary voltage 24 V/110 V AC/DC of Make ABB//Seimens/Schneider including fixing in HT panels at 11 kV substations with connections as per company diagram from OEM complete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement of auxiliary contact suitable for Make ABB//Seimens incl fixing in HT panels at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
3
-
-
... More
Supply and fixing in replacement of Digital type ammeter with 1.0 accuracy class (+)1% of full scale 1 count 0 to 300 Amps, stranded voltage burden 0.25 VA MAX/Phase working on AC auxillary supply voltage 230 volts, Sencing CT 5 Amps flush mounted type of size 96mm x 96mm x 75mm suitable for Make ABB//Seimens VCBs complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of Digital type voltmeter to measure AC voltage 0 to 500 Volts with 1.0 accuracy class, stranded voltage burden 0.25 VA MAX/Phase working on AC auxillary supply voltage 230 volts, flush mounted type of size 96mm x 96mm x 75mm suitable for Make ABB//Seimens VCBs complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of busbar insulator in HT panels at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge. Make ABB//Seimens/Schneider
12
-
-
... More
Supply and fixing in replacement PVC unsheathed multi stranded copper cable (FR-LSH) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs,nuts and bolts in VCBs complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement PVC unsheathed multi stranded copper cable (FR-LSH) 2.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs,nuts and bolts in VCBs complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement power pack with battery backup input 230 volt AC and out put 110 volt DC, 1A suitable for existing make ALAN model No APP-230110-SNS in VCBs ABB/Seimens complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement door lock suitable for existing make VCBs ABB/Seimens complete all as specified and directed.
8
-
-
... More
Taking down of HT RMU after disconnecting HT supply and reinstalled the same after repairing, servicing and testing of HT RMU and breakers, removing moisture and dust from HT bus bar and from inside of RMU panel of 11 KV substations complete all as specified and directed.
Note- (i) The Job shall be carried out through OEM only. (ii) Mesurement of (IR) resistance value tools, labour, petroleum jelly are included in this quoted rates. (iii) Parts will be replaced under relevent items.
6
-
-
... More
Supply and fixing in replacement of combined over current and earth fault relay of Make Ashida model no ADR141C or equivalent as specified incl fixing in RMU make ABB at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
2
-
-
... More
Supply and fixing in replacement of pressure guage of RMU complete of Make ABB incl fixing in HT panels at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
1
-
-
... More
Supply and fixing in replacement of indicator with electric wiring complete of Make ABB incl fixing in RMU at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
4
-
-
... More
Supply and fixing in replacement of cable boot of Make ABB incl fixing in RMU at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
4
-
-
... More
Supply and fixing in replacement of bushing with O ring of Make ABB incl fixing in RMU at 11 KV sub stations with connections complete as per diagram from OEM all as specified and directed by Engr in Charge.
1
-
-
... More
Supply and filling SF-6 gas upto required level by using gas filling adopter including testing after completion complete all as specified and as directed. Note:- (i) Necassary filling kit shall be provided by contractor and quoted rates are deemed to be included for the same.
(ii) Purchase voucher of gas brought at site shall be inspected and entered in MB as per instructions laid down for propreitory articles.
7
-
-
... More
Supply & Fixing in replacement of RMU Mechanism suitable for existing model fo RMU make ABB complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement push button red/green Make ABB incl fixing in RMU at 11 KV sub stations with connections complete all as specified and directed by Engr in Charge.
6
-
-
... More
Supply and fixing in replacement of tripping coil 24 V DC suitable for existing RMU make ABB complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of Geared motor suitable for existing RMU make ABB complete all as specified and directed
1
-
-
... More
S & F in replacement of unsv limit switch for Geared motor for suitable existing RMU make ABB complete as per direction of Engr-in-Charge.
2
-
-
... More
S&F in replacement of Current transformer of rating 400-200/1A size and model as suitable as existing RMU of Make ABB complete all as specified and directed.
1
-
-
... More
S&F in replacement of Current transformer of rating 200-100/1A size and model as suitable as existing RMU of Make ABB complete all as specified and directed.
1
-
-
... More
Disconnecting the HT & LT connections and taking down of existing Indoor/Outdoor/canopy type transformer of capacity upto 200 kVA mounted on 2/4 pole structure/plinth/substation and transport to factory from site/Power House/ AGE E/M yard for repair and back to site/Power House/ AGE E/M yard after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed by Engr-in-Charge. Note:
(a) The rate quoted for the item includes the following :-
(i) Arrangement of manpower, tools , plants , crane and recovery vehicle for transportation and shifting of transformer to work shop and back. (ii) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (Transformer oil will be measured and paid seperately). (iii) Re-winding of defective winding of transformer, if required will be carried out under this item . (Winding material shall be measured and paid separately under respective items) . (b) Re-winding of transformer and replacement of defective part will be carried out only after inspection of Engineer in Charge. ( Rewinding of Transformer will be paid separately) (C) Any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
3
-
-
... More
All as per serial item No 93.00 above but for transformer of capacity above 200 KVA and upto 1000 KVA complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement for non-metal part HV bushing complete with packing for outdoor/indoor/canopy type of transformer of capacity upto 200 KVA and for working pressure 11000 Volts complete all as specified and as directed by Engineer-in-Charge.
12
-
-
... More
Supply and fixing in replacement for non-metal part HV bushing complete with packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 KVA but not exceeding 1000 KVA and for working pressure 11000 Volts complete all as specified and as directed by Engineer-in-Charge.
6
-
-
... More
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 KVA complete all as specified and as directed by Engr-in-Charge.
12
-
-
... More
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 KVA and upto 1000 KVA, complete, all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type of transformer of capacity upto 200 KVA complete all as specified and as directed by Engr-in-Charge.
16
-
-
... More
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 KVA and upto 1000 KVA complete all as specified and as directed by Engr-in-Charge.
12
-
-
... More
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 KVA complete all as specified and as directed by Engr-in-Charge.
16
-
-
... More
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 KVA and upto 1000 KVA, complete, all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Supply and fixing in replacement top cover gasket of suitable size for outdoor/indoor/canopy type of transformer upto 1000 KVA complete all as specified and as directed by Engr-in-Charge.
10
-
-
... More
Dismantling of old Burnt Tap changer and Supply and fixing new tap changing switch as per existing size including making connection to transformer of various capacities/make complete all as specified and as directed by Engr-in-Charge.
2
-
-
... More
Supply and fixing in replacement 100 mm dia, temperature gauge including maximum temperature indicator complete all as specified and as directed by Engr-in-Charge.
15
-
-
... More
Material and Labour for preparing surfaces of transformer of capacity up to 200 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed by Engr-in-Charge.
Note. Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor.
20
-
-
... More
Description all as per Srl item No 106 hereinbefore but capacity of transformer exceeding 200 KVA and upto 1000 KVA , complete all as specified and as directed by Engr-in-Charge.
20
-
-
... More
Supply and fixing in replacement of gate valve with drain plug of suitable size for existig transformer, complete all as specified and as directed by Engr-in-Charge.
10
-
-
... More
Supply and fixing in replacement of conservator tank for step down distribution transformers of capacity upto 1000 KVA complete all as per specification and direction of Engr-in-Charge.
2
-
-
... More
Supply and fixing in replacement of locking arrangement door with handle, hinges and door opennig system including welding, cutting, bending and riveting for compact sub station step down distribution transformers of capacity from 400 KVA to 1000 KVA complete all as per specification and direction of Engr-in-Charge.
2
-
-
... More
Material and Labour for heating, filtration and dehydration of transformer oil as per IS : 10028 (Part-III) 1981, Para 5.2 (obtained from transformer/servo voltage stabilizer switch under repair at workshop) with dehydration/ filtration plant to achieve dielectric strength of 40KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge.
Note:- Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Engr-in-charge at his own expenses.
14000
-
-
... More
Supply and pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up after dehydration to achieve the di electric strength 60 KV at 4 mm gap and topping up in the transformer under repair in workshop complete all as specified and as directed by Engr-in-Charge.
Note : (i) Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
(ii) Purchase voucher of transformer oil brought at site shall be inspected and entered in MB date wise as per instructions laid down for propreitory articles.
2400
-
-
... More
Material and labour for rewinding of HV side of copper wound transformer with super enameled winding wire as per relevant IS, copper winding wire as per IS : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed .
120
-
-
... More
Material and labour for rewinding of HV side of copper wound transformer with DPC winding wire as per relevant IS, copper winding wire as per IS : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed .
120
-
-
... More
Material and labour for rewinding of LV side of copper wound transformer with DPC winding strip as per relevant IS, copper winding strip as per IS : 1180 and using as per original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding strip complete all as specified and as directed.
160
-
-
... More
Material and labour for rewinding of HV side of aluminium wound transformer with super enameled winding wire as per relevant IS, aluminium winding wire as per IS : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed .
160
-
-
... More
Material and labour for rewinding of HV side of aluminium wound transformer with DPC winding wire as per relevant IS, aluminium winding wire as per IS : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed .
160
-
-
... More
Material and labour for rewinding of LV side of aluminium wound transformer with DPC winding strip as per relevant IS, aluminium winding strip as per IS : 1180 and using as per original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding strip complete all as specified and as directed.
100
-
-
... More
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 KVA complete all as per specification and direction of Engr-in-Charge.
15
-
-
... More
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 KVA to 1000 KVA complete all as per specification and direction of Engr-in-Charge.
15
-
-
... More
M&L for repairing the GOD mechanism pipe and handle lever, etc. by way of welding, greasing and including supply and fixing of new male and female contact complete all as specified and directed
4
-
-
... More
Material and labour for cleaning and spraying chemical to remove unwanted vegitation/ grass at various11 KV sub-stations as directed by Engr-in-Charge. Note : (i) Labour and equipments required to spray chemical on required area are included in the quoted rates. (ii) Purchase voucher of chemical brought at site shall be inspected and entered in MB as per instructions laid down for propreitory articles.
(iii) The frequency of cleaning shall not be less than 2 months, however area of sub station shall be measured at once for purpose of measurement and payment. In case of non maintaing of required frequency the quantity shall be reduced proportinately.
1550
-
-
... More
Trimming of tree branches upto 75 mm dia to clear the route of HT/LT over head conductors in switch yards and open joints upto 3m from the 125 conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by Engineer-in-Charge. Note: (i) One/more tree branches covering 3m shall be considered as one unit. (ii) The frequency of trimming of tree branches shall not be less than 2 months.
55
-
-
... More
Supply and fixing of Dew Guard (Moisture absorber) of size 100x150x2 mm shall be made of synthetic rubber and a super absorbent polymer and covered by a non woven fabric, absorbency of 0.8g (H2O) / 1g (product) @25 deg C and 95% RH or higher, works between a large temperature range of -30 deg C to +90 deg C, halogen and silicon free, Make :- Hensel model No HDG 100 suitable model of ABB/Seimens HT panel of 11 KV substations complete all as specified and directed by Engineer-in-Charge.
43
-
-
... More
Supply and fixing of of in panel tube based micro environment suppression system (CQRS) having heat-sensetive preumatic polymer tubing connected to one to a charged fire extinguisher with valve 20 mtr polymer tubing, operating temp 150-180 degree celcius complete all as specified and directed by Engineer-in-Charge. Make Ceasefire
3
-
-
... More
M & L for excavator for cable digging in emergency during nights/ off working hours/days as required at site complete all as per direction of Engr-in-Charge
Note:- (i) Before submitting claims for payment under this item, the contractor shall provide detailed documentation for the deployed equipment like Purchase Invoice, Ownership Proof, Registration Certificate (RC), Insurance Details etc.
(ii) The Engineer-In-Charge shall maintain a logbook showing information like execution activities, date, time etc in order to esblish the actual duration of running of equipment and subsequent entry in the MB.
12
-
-
... More
Note:- Amount of credit of Rs. 207874.00 for retrieved materials is mentioned in Schedule of Credit Page No. 17 & 18 of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%