Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 88,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681932_1Tender No
GE (AF) Gurgaon No 1/GUR-63/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
One light point controlled by one way one switch SP 5 Amps , 240 V.
60
-
-
One ceiling fan/Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
5
-
-
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
20
-
-
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
15
-
-
All as per the item No 2 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
15
-
-
S&F switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge.
65
-
-
S&F switch piano flush type single pole one way , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
15
-
-
S&F socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
35
-
-
S&F socket outlet 2 in 1 ,3 pin 5 and15 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
15
-
-
S&F step type elctronic fan regulator flush type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor or equivalent.
5
-
-
Taking out old unserviceable submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
200
-
-
M&L sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 6 Sqmm and one run of 6 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
200
-
-
S&F Onload Changeover switchs of capacity 630Amps SS operated 415V , 50 Hz conforming IS/IEC 60947-1 & 3 complete all as specified and directed by Engineer-in-Charge.
1
-
-
S&F in replacement Onload Changeover switchs of capacity 200Amps SS operated 415V , 50 Hz conforming IS/IEC 60947-1 & 3 complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in replacement Onload Changeover switchs of capacity 160 Amps SS operated 415V , 50 Hz conforming to IS/IEC 60947-1 & 3, complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in replacement Onload Changeover switchs of capacity 100 Amps SS operated 415V , 50 Hz conforming to IS/IEC 60947-1 & 3, complete all as specified and directed by Engineer-in-Charge.
1
-
-
S & F in replacement LED Tube light surface and wall mounted LED batten of 20W, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD10% complete all as specified and directed by Engineer-in-Charge.
60
-
-
S&F in replacement sheet metal enclosure for MCB's (D.B) 4 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed.
1
-
-
S&F in replacement sheet metal enclosure for MCB's (D.B) 6 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed.
1
-
-
S&F in replacement sheet metal enclosure for MCB's (D.B) 8 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed.
1
-
-
S&F in replacement sheet metal enclosure for MCB's (D.B) 12 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed.
1
-
-
S&F in replacement sheet metal enclosure for MCB's (D.B) 4 way (TPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed.
2
-
-
S&F in replacement of MCB SPN 06- 32 amp ‘C’ Series (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 10kA, capacity complete all as specified and as directed.
20
-
-
S&F in replacement of MCB SP 06- 32 amp ‘C’ Series (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 10kA, capacity complete all as specified and as directed.
20
-
-
Dismantling and taking up old existing unserviceable GI/copper earth plate with strip earthing and connected items complete all as specified and as directed by Engr in charge.
65
-
-
M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead with 4mm dia by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 5 including earth work final with watering arrangement, wire mesh, GI pipe 50mm internal dia bore buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed by Engr-in-charge including testing on completion.
65
-
-
M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x3 mm Copper strip including taking down existing copper strip complete all as specified and directed
50
-
-
S&F in replacement of porcelin viterous white/ brown/ green insulators of sizes 25mm x 25mm having provision of two holes for fixing on roof / wall under strip/ channel on top for running of down conductors to maintain gap between wall and down conductors etc complete all as specified and directed by Engr-in-Charge.
200
-
-
M&L for earthing pit with brick work and PCC 1:3:6 including RCC pit cover of size 300x300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pit all as specified and as directed by Engr-in-charge
70
-
-
M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x3 mm aluminium strip including taking down existing aluminium/GI strip complete all as specified and directed by Engr-in-Charge .Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body. (Cost of insulator shall be measured and paid seprately under respective items of Sch of works as supply only)
50
-
-
S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
180
-
-
S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 10 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge. Make :-Plaza/Polycab/Havells or from the make specified in list of make.
180
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 16sqmm 4core all as specified and directed
150
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 10sqmm 2core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 25sqmm 4core all as specified and directed
150
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 35Sqmm 3.5core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 50Sqmm 3.5core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 70Sqmm 3.5core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 120Sqmm 3.5core all as specified and directed
120
-
-
S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 400Sqmm 3.5core all as specified and directed
240
-
-
Supply and fixing in replacement of galvanized iron tubing 100mm bore medium grade with all fittings with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply and fixing in replacement of galvanized iron tubing 80mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply and fixing in replacement of galvanized iron tubing 50mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply and fixing in replacement galvanized iron tubing 40mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply and fixing in replacement galvanized iron tubing 25mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
24
-
-
Supply and fixing in replacement galvanized iron tubing 20mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
24
-
-
Supply and fixing in replacement galvanized iron tubing 15mm bore medium grade with all its fittings i.e union ,tee, elbow etc used for connection complete all as specified and directed by Engineer-in-Charge.
24
-
-
M&L complete for drilling hole through machine under hard standing /road in different location as per site requirement (between 03 mtr to 40mtr maximum) for laying of pipe for protection of cable etc by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
40
-
-
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for foundation etc or for shafts wells, cesspits, mahnoles, pier holes ect not exc 10 Sqm on plan and not exc 1.5M in depth and getting only out in Hard/dense soil complete all as specified
30
-
-
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as sepecified and directed.
245
-
-
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as sepecified and directed.
130
-
-
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed
115
-
-
M&L for sand cushioning in trenches/floor for protection including watering and consolidation all as specified and directed
61
-
-
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as sepecified and directed.
6.53
-
-
S&F Bricks, sub class B, laid flat, in floors, old size bricks laid dry complete all as specified and directed
250
-
-
S&F in replacement of switch flame proof rotary type with termination box in LM6 , 16 Amps , single pole 240 volts complete all as specified.
2
-
-
Supply and fixing in replacement of LED flameproof fitting 2x18Watt , Degree of Protection : IP-66 Protection As per IS/IEC 60529:2001, Material of Construction : Aluminium Alloy LM-6, Area classification -GAS Group I, IIA & IIB & IIC As per IS/IEC 60079-1:2007, Gas group -I, IIA & IIB & IIC, Glass : Heat Resistant & Stress Free, Borosilicate Type clear Glass, Cable Entry : 3/4"ET - 02 Nos complete all as sepecified and directed.
10
-
-
M&L Preperation of old painted Steel surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of Red oxide primer all as specified and directed by Engineer -in-charge
700
-
-
Supply and fixing in replacement of new generation energy saving environemental friendly long life exclusive innovative die cast aluminium IP65 LED flood light with high power LEDs as light source of capacity 120 Watt complete all as specified and directed by Engineer-in-Charge.
30
-
-
Supply and fixing in replacement LED Street Lights 72 Watt, CCT not less than 5700k and Efficacy not less than 110lm/W with Potted Driver of pressure die-cast aluminium housing street lights have clear toughened glass diffuser and bottom opening driver compartment. It comes up with secondary optics and individual high power LEDs for better light distribution and control. K08 street light with IP66 degree of protection and Potted Driver with 5KV internal and 10KV external surge protection alongwith 40mm dia Medium Grade GI Pipe of 1mtr with bracket and stand for fixing in wall complete all as directed and specified by Engr-in-charge.
20
-
-
S& F in replacement of MCCB 63Amp, 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge
5
-
-
S& F in replacement of MCCB 100Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge
6
-
-
S& F in replacement of MCCB 160Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge
4
-
-
S& F in replacement of MCCB 250Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge
3
-
-
M&L for Cleaning of pump house from inside and outside in every month duly taking out unwanted material grass/vegetation/roots etc all as specified and directed by Engr-in-charge.
Note : Rate include cleaning of 5 pump house to be treated as a one job. Tools required for cleaning will be provided by the Contractor.
9
-
-
M&L for spraying of chemical (roundup) around pump house in the ration 1:3 for burning of grass as an when required complete all as specified and directed by Engr-in-charge
1800
-
-
M&L for PCC in foundations, filling and mass-concrete 1:3:6 type-C2 using 40 mm graded stone aggregate complete all as specified and directed
10
-
-
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter fair finished surfaces of concrete flat complete all as specified and directed.
5
-
-
S& F of Double Walled Corrugated Pipe (DWC) conforming to IS:14930 (Part-II) /IS 16205 Part II of Size 160/136 colour of pipe outer & Inner is of orange all as specified and directed by Engr-in-charge. Make : Dutron / Supreme / SFMC/ Tirupati or equivalent approved in MES by any Command.
60
-
-
S& F of Double Walled Corrugated Pipe (DWC) conforming to IS:14930 (Part-II) /IS 16205 Part II of Size 110/95 , colour of pipe outer & Inner is of orange all as specified and directed by Engr-in-charge. Make : Dutron / Supreme / SFMC/ Tirupati or equivalent approved in MES by any Command.
100
-
-
S& F of Double Walled Corrugated Pipe (DWC) conforming to IS:14930 (Part-II) /IS 16205 Part II of Size 300/260, colour of pipe outer & Inner is of orange all as specified and directed by Engr-in-charge. Make : Dutron / Supreme / SFMC/ Tirupati or equivalent approved in MES by any Command.
20
-
-
S& F of Double Walled Corrugated Pipe (DWC) conforming to IS:14930 (Part-II) /IS 16205 Part II of Size 90/76 colour of pipe outer & Inner is of orange all as specified and directed by Engr-in-charge. Make : Dutron / Supreme / SFMC/ Tirupati or equivalent approved in MES by any Command.
100
-
-
S&F Insulation mat long-lasting, easy to install, clean an anti-skid a strong grip mat which is resistant to oils, acids, alkalis . low temperature and are flame retardant as per the provisions of IS 15652:2006.of thickness 2.5mm, Class B having 100% shock proof under leakage current 10 mA all as specified and directed by Engr-in-charge. Make :- Jyoti / Aicon / Vardhman or equivalent confirming to IS specification.
Note: Test certificate from a Govt registered company should be submitted before installation.
30
-
-
S&F Insulation mat long-lasting, easy to install, clean an anti-skid a strong grip mat which is resistant to oils, acids, alkalis . low temperature and are flame retardant as per the provisions of IS 15652:2006.of thickness 2mm,mat size , Class A having 100% shock proof under leakage current 10 mA all as specified and directed by Engr-in-charge. Make :- Jyoti / Aicon / Vardhman or equivalent confirming to IS specification.
Note: Test certificate from a Govt registered company should be submitted before installation.
30
-
-
Taking out old steel tubler poles 9 mtr by breaking PCC foundation, and all related work and making the site well finished and Shifting of Pole to another location within 54 ASP area (i.e.Tech Area/G Block/admin area/H-block, D-camp etc) complete all as specified and as directed by Engr-in-charge.
26
-
-
M&L for Fixing steel tubular pole single arm type 9 M retrieved from item No 31 hereinbefore including excavation in trenches in soft/ loose soil n exc1.5 M wide and net exc 1.8 M in depth and triming the sides , boring bottom surfaces to required level, providing PCC (1:3:6) type D-2 using 40mm stone agregate in foundation, 1.5 mtr GI pipe medium grade of 40mm dia for cable protection and PCC 1:2:4 type B-1 coping of pole including neccessory frame work complete all as specified and as directed by Engr-in-charge.
26
-
-
S&F Casing Caping PVC Size 25 mm alongwith nails complete all as speciified and directed by Engr-in-charge
40
-
-
M& L for laying of Gravels/stone of size 40mm each complete all as specified and directed by Engr-in-charge
Note: Gravels/stone should not be plane,cut or broken. All Stone/Gravels must be clean.
20
-
-
Supply, installing, testing and commissioning factory made and tested in replacement of LT panel of any type to LT Panel Outdoor type of size 1050 X 450 X 1200 mm ( LxWxH ), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Angle frame work of 50 X 50 X 6 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete with necessary PCC 1:3:6 foundation work as directed at site. The scope of work also comprising of the following:-
2
-
-
INSTRUMENT CHAMBER:- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with in-built selector switch- 01 Set. (b) Digital Amp Meter, 96X96mm, flush type rated 0-300 A, with in-built Selector switch- 01 Set. (c) C.T's 300/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(d) Red, Yellow, Blue Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).
Make of Metering Accessories :- L&T/ AE/ Trinity/ Schneider.
INCOMING SUPPLY:- (i) MCCB 100 Amps 10/16 KA , 4 Pole with Adjustable thermal & fixed magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ ABB/ Siemens / Legrand
OUTGOING SUPPLY:- (i) MCCB 63 Amps 10 KA, 4 Pole with Adjustable thermal & fixed magnetic release 415 volts, 50Hz,= 03 Nos., Make of MCCB:- L&T/ ABB/ Siemens/ Legrand.
-
-
-
Note : The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54
2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA
3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation volta
-
-
-
Sevicing & Replacement of parts of Air blower complete all as specified and directed by Engr-in-charge
Note:-Parts is included in separate sch of work
2
-
-
Bearing Serial No 6307-2Z-C3
2
-
-
Bearing Serial No 6306-2Z-C3
1
-
-
Oil Seal
2
-
-
Safety relief Valve
1
-
-
Lubrication Oil
5
-
-
Gear
1
-
-
Note:- (a) The amount of Rs 51076.00/- against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%