Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_635887_1Bid Award Id
ViewTender No
CA NO GE U AMB T 74 OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item ser No 2 here in before but for Race Course Power House.
4750
-
-
... More
Note for items No 01 to 04 :-
Note ‘A’ :- (i) Any complaint left unattended by the electrician will be communicated to the JE in-charge /AGE E/M with reason. No charge will be paid for the per complaint till the complaint is resolved.
(ii) New material /stores provided for completing the job shall be measured and paid for separately under relevant items of BOQ.
(iii) Contractor shall provide all type of T&P of HT/LT network, bamboo ladder with safety gloves to each electrician for attending the external electric complaints.
(iv) Contractor shall provide the complaint register 200 pages – 10 No, complaint book with 100 slips- 20 No. Booklets serially numbered in triplicate for the contract period.
(v) Contractor has to arrange 03 No. Experienced Electrician having minimum 5 years experience ( 01x three shifts per day) and 03 No. Helper having minimum 2 years experience including Sundays and Holidays to attend HT Complaints so that complaints can be cleared within stipulated period. (vi) Contractor has to deploy well experienced and well conversant a person for lodging the complaint in complaint cell of each power house during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays. (vii) The Contractor shall provide insurance cover of minimum Rs 5 lakh per head under IE Rules 2003 and Minimum wages Act to all qualified and helpers.
(viii) Cost of materials for laying of cables, strecthing of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as Material & Labour.
(ix) Penal recovery @ Rs 500/- per complaint per hour will be levied from the contractor in case of late attending of complaint after reasonable time or 2 hours whichever is more as decided by Engr-in-Chage / GE.
-
-
-
... More
(xi) The scope of work cover all complaints received from above concern power houses will be lodged/docketed/attended/completed. The completion will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :- (a) Blown out fuses (b) Faulty Insulator
(c) Loose GOD male & female contact (d) Fault cable joint (e) O/H conductor broken (f) Broken jumpers (g) Tightening of stay (h) Stretching of broken loose fault conductor and binding on insulators up to 3 span (j) Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time.
(k) Tightening of service connection as preventive maintenance (l) Proper Uniform shall be provided by the contractor for pers employed on duty as desired by Engr-in-Charge.
(m) Tracing fault manually in LT/HT electric lines and underground cable network
(n) AC Complaints like connection / disconnecting (o) Fault HT/LT switchgears (p) Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge. Penel recovery for Rs 100/- per day will be recovered if street light not put ON/OFF at appropriate time. (q) The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears, streer lights etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area.
(r) Any other electric complaint which is considered essential by the department.
(s) Confirmation on completion of any nature of major complaints will be intimated to JE concerned to the area or Engr-in-Charge immediately.
(t) The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue.
(u) Insurance, Education Qualification and experience cert for the personnel employed on duty shall be submitted to Engr-in-Charge before take over the installation.
(v) The contractor will provide the rain coats, gum boot and hand gloves in winter and summer season.
(w) Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies.
(x) Contractor will be provide vehicle (3/4 wheel) for attending the complaint under above power house area..
-
-
-
... More
Labour only for carry out visual inspection of transformer once in month including minor maintenance like dusting ,tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level ,top up if required ,checking of silca gel ,heating/replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed by Engr-in-Charge.
710
-
-
... More
Trimming of Tree branches falls into OH lines of HT/LT & minimum clearance of 3 Mtr from branches ,proper shutdown will be taken and maintained in the register complete all as specified and as directed.
650
-
-
... More
Maintenance of sub Station including cleaning In /out of surroundings areas, zeroing of grass in two pole & four pole structure ,loose filling of sand/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained all as specified and directed by Engr -in-Charge.
700
-
-
... More
Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight through joint of size 95-185 Sqmm.
Notes
(a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate.
(b) Charges of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate.
(c) Earth fault locator shall be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will be levied @ Rs 500/ per hour.
(d) Straight through joint , Labour charges, excavation and making joint deemed to be including in quoted rate.
20
-
-
... More
Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 25-50 Sqmm
5
-
-
... More
Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm
10
-
-
... More
Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm
10
-
-
... More
Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.50 240-300 Sqmm
5
-
-
... More
Material & Labour straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4 x 25-50 Sqmm
3
-
-
... More
Material & Labour straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm
5
-
-
... More
Material & Labour straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm
3
-
-
... More
Material & Labour in replacement of old UNSV shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm high, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed.
50
-
-
... More
Material and labour in replacement of aluminium conductor steel reinforced (ACSR) conductor of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) or other existing type conductor ISI marked for LT over head lines on poles including stretching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engineer-in-Charge.
3.8
-
-
... More
Material & Labour 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core
540
-
-
... More
All as per item ser No 18 here in before but for 6 sqmm 2 core
270
-
-
... More
All as per item ser No 18 here in before but for 4 sqmm 2 core
270
-
-
... More
Material & Labour in replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type with thermal magnetic release complete all as specified and directed.
4
-
-
... More
Material & Labour in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
4
-
-
... More
Material & Labour in replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
4
-
-
... More
Supply only in replacement MCCB TPN 100/125 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
5
-
-
... More
Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm
100
-
-
... More
Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm
100
-
-
... More
Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm
50
-
-
... More
Suply only chemical (Round up) for remove unwanted vegitation/grass at various locations .
25
-
-
... More
Material & Labour straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
6
-
-
... More
All as per item ser No 29 here in before but for cable 150-240 sqmm 3 core
2
-
-
... More
Material & Labour cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 70-120 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
10
-
-
... More
All as per item ser No 31 here in before but for cable 150-240 sqmm 3 core
5
-
-
... More
Supply and fix in repair LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
All as per item ser No 33 here in before but for 5 line
50
-
-
... More
Re-stretching existing/retrieved ACSR conductor on LT /HTpole and binding conductor on insulator properly using new binding wire/jumper wire complete all as directed by Engr-in-Charge.
Note : (i) Each Run of line conductor shall be measured & paid for separately.
12000
-
-
... More
Material & Labour for in replacement of steel nuts, bolts, washers of any size required at site as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled red colour with letters, figures , and conventional skull and bone in signal white colour and fixed with MS clamps bolts approved size ofr HT 25cmx20 cm.
30
-
-
... More
Supply only of Tinned copper fuse wire of size 27/33 S.W.G. for GOD ISI marked all as specified and as directed.
5
-
-
... More
All as per item ser No 38 here in before but for 23/24 S.W.G.
8
-
-
... More
Supply only of PVC self adhesive insulation tape of Size .125mm x 25mm x 25 mtr long ISI marked all as specified and as directed.
300
-
-
... More
Loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as per direction of Engr-in-Charge.
10
-
-
... More
M&L for providing plain cement concrete type C-2, 1:3:6 (using 40 mm grade stone aggregate) as in coping, finished even and fair, including necessary from work all as directed at site.
4
-
-
... More
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old unsv cross arms and misc accessories.
4
-
-
... More
Supply only pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge.
Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
660
-
-
... More
Material and labour in replacement of silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 11 KV stations complete as per site requirement complete, all as specified and as directed.
25
-
-
... More
Dismantling and taking down old unsv GOD and Supply, installing, testing and commissioning of air break gang operated triple switch( GOD) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
Dismantling and taking down old unsv LA and Supply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating complete all as specified directed.
25
-
-
... More
Material & Labour for surface cleaning of primer LT steel tubular poles 9 mtrs long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as directed.
Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall include the repairing of coping with cement / PCC (1:2:4)
180
-
-
... More
Material & Labour for cement base paint for PCC pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl incl repairing and painting on coping with cement base white paint complete all as directed.
Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall include the repairing of coping with cement / PCC (1:2:4).
300
-
-
... More
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result all as specified and directed.
40
-
-
... More
Material and labour in repairs of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire all as specified and directed.
100
-
-
... More
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash all as specified and directed.
70
-
-
... More
Supply and fixing in replacement of off load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
All as per item ser No 53 here in before but for 200 Amps capacity
3
-
-
... More
Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete, all as specified and as directed.
40
-
-
... More
S&F in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket with clamp from juction box to connecter of street light fitting all as specified and as directed.
80
-
-
... More
S&F in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed
160
-
-
... More
S&F in replacement of extended spreaders link should be installed both side with exisitng/new MCCBs 4P/3P of any capacity with existing LT panels complete all as specified and directed by Engineer-in-Charge.
30
-
-
... More
M&L Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium busbar and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge.
80
-
-
... More
Supply and fix in replacement of MCB SP 6-32 Amps, 240 volt,10 KA 'C' curve including all accessories complete all as specified and directed.
80
-
-
... More
Supply and fix in replacement of MCB DP 16-40 Amps, 240 volt,10 KA 'C' curve including all accessories complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
360
-
-
... More
All as per item ser No 63 here in before but for 2.5 sqmm
360
-
-
... More
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates complete all as specified and directed.
300
-
-
... More
Taking down old unserviciable board and supply and fixing of Retro reflective sign board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 4mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed.
NOTE:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
55
-
-
... More
M&L XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT cable complete all as directed by Engr-in-charge .
220
-
-
... More
All as per item ser No 67 here in before but for 120 sqmm 3core
150
-
-
... More
Supplying and fixing in replacement of light grade galvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, path, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
18
-
-
... More
Dismantling and taking down security light, street light, hanger light, flood light and high mast light of any type at any height fittings such as HPSV/HPMV/MH/LED light of 48 Watt/ 60 watt / 70/72 watt/ 90 watt/ 120 watt/ 150 watt/ 200 watt and 300 watt of any make etc. AC 230 volts any wattage from pole/wall roof top/hanger roof including washing/cleaning of perplex cover inspection for location of fault and replacing of defective speare/parts required for smooth functioning, tighting of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed. Note: Defective spare/ part of relevant light fitting shall be measured and paid separately under relevant item as supply only.
429
-
-
... More
Supply only LED electronic driver/adaptor/SPD for 40-60 watt LED security light fitting existing make all as specified and directed.
20
-
-
... More
Supply only LED electronic driver/adaptor/SPD for 70/72 watt LED security light fitting existing make all as specified and directed.
150
-
-
... More
Supply only LED electronic driver/adaptor/SPD for 90 watt LED security light fitting existing make all as specified and directed.
200
-
-
... More
Supply only LED electronic driver/adaptor/SPD for 60-150 watt LED flood light fitting existing make all as specified and directed.
39
-
-
... More
Supply only LED electronic driver/adaptor/SPD for 200-300 watt LED flood light fitting existing make all as specified and directed.
20
-
-
... More
Supply & fixing in replacement of Integral LED Flood light Luminaries 150 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency 130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI70% operating voltage range 160 V-270 V, Power factor 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :- PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to flood light shall be measured and paid for separately.
10
-
-
... More
Supply & fixing in replacement of LED street light fitting 90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency 110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI70% operating voltage range 140 V-270 V, Power factor 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :- PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street light shall be measured and paid for separately.
43
-
-
... More
M & L for prepering old painted steel suraces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint over redoxide complete all as speciied and directed.
100
-
-
... More
Material and labour of Bamboo ladder 24' height (24 steps ) for LT line and 27 ' height (27 steps ) for HT line complete all as specified and directed by Engineer-in-chage..
4
-
-
... More
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 KVA complete all as per specification and direction of Engr-in-Charge.
8
-
-
... More
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 KVA to 1000 KVA complete all as per specification and direction of Engr-in-Charge.
10
-
-
... More
M&L for repairing the GOD mechanism pipe and handle lever, etc. by way of welding, greasing and including supply and fixing of new male and female contact complete all as specified and directed
8
-
-
... More
Supply and topping up of Acid Mixture suitable for Lead Acid batteries of capacity 12V / 24V all as specified and as directed.
15
-
-
... More
S&F heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12V 180 AH maintenance free battery suitable for DG set all as specified and directed.
4
-
-
... More
S & F self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage complete all as specified and directed by Engr-in-Charge .
100
-
-
... More
Supply only HT discharge rod 11-33 KV FRP type with all accessories complete all as specified and directed
4
-
-
... More
Supply only HT rubber hand gloves 11 KV with electrical insulated latex seamless complete all as specified and directed
4
-
-
... More
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 100 volts including connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
800
-
-
... More
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
243
-
-
... More
M & L sand cushioning for cable with river washed sand with layer of sand 8cm before laying of cable and 15cm after laying of cable punned to 18cm thickness complete all as specified and as directed by Engineer-in-Charge. Note: Sand cushioning shall be punned to 18cm thickness and same shall be measured and paid.
55
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class precast concrete cable cover, class HV,Type 1 with peak, size 300mm x 180 mm x 40 mm complete all specified and directed by Engr-in-charge.
750
-
-
... More
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed by Engineer-in-Charge.
6.4
-
-
... More
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
143
-
-
... More
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as directed by Engineer-in-Charge.
100
-
-
... More
Note:- Amount of credit of Rs 79030.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements