Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge U/chm-39/2024-25 Repairs And Maintenance To Internal Electrification Works For Icu Ot Posu Rsc Surg-i
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684726_1Tender No
GE(U)/CHM-39/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor 1100 V grade drawn through and including non-metallic rigid 20 mm dia PVC conduit, medium grade, including conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (made out of 1.6 mm thick MS sheet), modular metal frame plate and white cover for switches, sockets / regulators etc., including 1.5 Sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers etc., complete all as specified and directed for follwing points controlled by one one-way 6A switch.
NOTE:- (i) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces. (ii) Modular metal boxes and modular white cover with frame etc. will be measured and paid separately in the relevant items of this schedule.
385
-
-
All as per Srl item No. 04 here-in-before but one 05 Amp socket outlet point on independent board controlled by one, single pole, one way switch, complete all as specified and directed.
205
-
-
All as per Srl item No. 04 here-in-before but one 05 Amp socket outlet point on same board controlled by one, single pole, one way switch, complete all as specified and directed.
75
-
-
All as per Srl item No. 04 here-in-before but one light point controlled by two switches, single pole, two way 240V, complete all as specified and directed.
5
-
-
All as per item No. 04 here in before but for one bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size all as specified and directed by Engineer - in - Charge.
5
-
-
All as per Srl item No. 04 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable for one multipurpose switch socket outlet 6 pin 6/16 Amps on independent board including 2.5 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
125
-
-
S&F Modular switch 1 way 6A, 1 module, one way all as specified and directed by Engineer - in – Charge.
770
-
-
S&F Modular switch 1 way 16A, 1 module, one way all as specified and directed by Engineer - in – Charge.
125
-
-
S&F Modular Bell push 6A, 1 module, single pole one way, all as specified and directed by Engineer - in – Charge .
5
-
-
S&F switch modular two way 6A, 1 module all as specified and directed by Engineer - in – Charge.
10
-
-
S&F electric call bell/ buzzer, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge.
5
-
-
S&F modular socket, 6A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
280
-
-
S&F modular socket 6A/16A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
125
-
-
S&F modular fan step type regulator, 120W - 2 module all as specified and directed by Engineer-in –Charge.
50
-
-
M & L ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
385
-
-
S&F in replacement of LED tube light fittings 1 x 10 W robust and high performance batten comprises extruded channel in thermally conductive material. High translucent serrated milky white diffuser is used to get glare free and smooth light distribution. Efficiency 100 lm/W.
25
-
-
S & F in replacement of LED polycarbonate T8 tube with inbuilt driver and metal heat sink 20W , efficiency 100 lm/W connecting complete all as specified and directed by Engineer-in-Charge.
50
-
-
S&F in replacement of heavy duty batten pre coated CRCA body, suitable for retrofit LED 1X18/20W LED tube and connecting complete all as specified and directed by Engineer-in-Charge.
50
-
-
S&F in replacement of surface mounted of size 2'x2' LED 36 watt Luminaire equiped with CRCA powder coated housing, antiglare diffuser with separate energy electronic driver of capacity 36 Watt minimum, 5700 K, including fixing arrangement with existing complete all as specified and directed by Engineer - in – Charge.
100
-
-
S&F in replacement of indoor LED batten extruded thermoplastic body 4 feet with milky diffuser including 18 Watt 6500K LED strip including driver, accessories to fix the same with existing wall and all connected accessories as per manufacturer's recommendation complete all as specified and directed by Engineer - in – Charge.
150
-
-
S&F in replacement of surface/recess mounted slim square type LED panel with die cast aluminium housing and smooth powder coated finish with antiglare UV stabilized diffuser and separate energy efficient electronic driver having wattage 12 watt LED panel light having dimensions 120x120mm and making connection accessories complete all as specified and directed by Engineer - in – Charge.
25
-
-
S&F in replacement of LED Luminaire 36 Watt suitable for Armstrong/ grid ceilling, of size 2'x2' with its super bright LED, including LED strip, recess mounted with drivers and others accessories as per manufacturer's recommendation including fixing arrangement complete all as specified and directed by Engineer - in – Charge.
150
-
-
S&F in replacement of decorative wall mounted lamp (Bed side light) with white opal glass & Nickel finishing including 1 x 7 watt LED lamp complete all as specified and directed by Engineer - in – Charge.
50
-
-
S&F in replacement of recess mounted round/ square LED down light with die cast aluminium housing and smooth powder coated finish with anti glare UV stabilized diffuser and separate energy efficient eletronic driver with 15 Watt LED lamp and making connection accessories complete all as specified and directed by Engineer - in – Charge.
25
-
-
S&F in replacement of span recessed and surface LED 1 x 4 ft panel ceiling light with high performance, commercial grade solution suitable for hospitals, schools, offices and so much more ( 100lm/W) having white powder coated CRCA housing, antiglare diffuser with separate energy electronic driver of capacity 36 Watt including fixing arrangement with existing complete all as specified and directed.
125
-
-
S & F in replacement of electronic driver of 36 watt, 2.5 KV surge protection as per existing in site suitable for LED ceilling light 02 x 02 ft, 01 x 04 ft, input supply 140V -270V and output 12 Volt DC.
50
-
-
S&F in replacement of ultra bright 18 Watt LED PLL base lamp 4 pin (upto 100 lm/W) with very high efficiency suited for installation in existing 2G11 lamp holder to give glare free light sitable for 02' x 02' fixtures as per sample complete all as specified and as directed by Engineer-in-Charge.
10
-
-
S&F in repairs MCB distribution board of sheet metal single pole and neutral (SPN) 12 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
5
-
-
S&F in repairs MCB distribution board of sheet metal single pole and neutral (SPN) 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
10
-
-
S&F in rapairs MCB distribution board of sheet metal single pole and neutral (SPN) 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in repairs sheet metal enclosure distribution board triple pole and neutral (TPN) 4 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
8
-
-
S&F in repairs sheet metal enclosure distribution board triple pole and neutral (TPN) 8 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
5
-
-
S&F in repairs sheet metal enclosure distribution board triple pole and neutral (TPN) 12 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
2
-
-
S&F in repairs VTPN DB 4 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed.
Note:-
(i) MCB's and MCCB's shall be measured and paid separately.
2
-
-
S&F in repairs VTPN DB 6 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as incomer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed. Note:-
(i) MCB's and MCCB's shall be measured and paid separately.
2
-
-
S&F in repairs VTPN DB 8 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed.
Note:-
(i) MCB's and MCCB's shall be measured and paid separately.
5
-
-
S&F in repairs VTPN DB 12 way with MCCB as incomer, metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incomer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed. Note:-
(i) MCB's and MCCB's shall be measured and paid separately.
2
-
-
S&F in repairs MCCB 63 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
2
-
-
S&F in repairs MCCB 100 Amp, 415Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
5
-
-
S&F in repairs MCCB 125 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
5
-
-
S&F in repairs MCCB adjustable thermal (70%-100%) & adjustable magnetic setting, three pole, 160 Amps, 415 Volt, breaking capacity 36 KA complete all as specified and as directed by Engineer-in-Charge.
2
-
-
S&F rapirs MCCB adjustable thermal (70%-100%) & fixed magnetic setting, three pole, 200 Amps, 415, breaking capacity 36 KA complete all as specified and as directed by Engineer-in-Change.
1
-
-
S&F in repairs MCCB adjustable thermal (70%-100%) & fixed magnetic setting, three pole, 250 Amps, 415 Volt breaking capacity 36 KA complete all as specified and as directed by Engineer-in-Charge.
1
-
-
S&F in repairs MCB Three Pole and Neutral (TPN) 40-100 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
25
-
-
S&F in repairs MCB Single Pole and Neutral (SPN) 40-63 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
45
-
-
S&F in repairs MCB Single Pole (SP) 06-32 Amps, 240 Volt, 'B' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
150
-
-
S&F in repairs MCB Single Pole (SP) 06-32 Amps, 240 Volt 'C curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
150
-
-
S&F in repairs MCB single pole (SP) 40 Amps, 240 volt, 'B' curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
25
-
-
S&F in repairs single pole and neutral enclosures with two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 V all as specified and directed by Engineer - in - Charge.
25
-
-
Taking down ceiling fans of any size for servicing by cleaning dust, filling cavities with filler and oiling/greasing and re-fixing the same in position, connecting and testing all as specified and directed.
50
-
-
Taking down exhaust fans of any size for servicing by cleaning dust, filling cavities with filler and oiling/greasing and re-fixing the same in position, connecting and testing all as specified and as directed.
15
-
-
S&F in replacement of MS down rod heavy duty 15mm nominal dia 24" long duly painted in matching colour including taking down existing complete all as specified and as directed.
25
-
-
S&F in replacement of MS down rod heavy duty 15mm nominal dia 36" long duly painted in matching colour complete all as specified and as directed.
50
-
-
Taking down existing Split/Window/Tower AC of 1.0/1.5/2.0/5.0 TR capacity for servicing by water cleaning dust, filling cavities with filler complete and re-fixing the same position after completion of civil work, connecting and testing complete carefully, all as speciied and directed.
25
-
-
M & L as in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 16 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated one run single core cable 16 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge
Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
125
-
-
M & L as in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 10 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated one run single core cable 10 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge
Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
125
-
-
M & L as in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 6 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated one run single core cable 6 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge
Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
75
-
-
Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLSH copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 2.5 sqmm dia FRLSH PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, one runs of 2.5 sq.mm copper earth continuity conductor shall be measured as one unit length.
(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
(iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces.
250
-
-
S&F in repairs submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 4 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one runs of 4 sq.mm copper earth continuity conductor shall be measured as one unit length.
(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
(iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces.
450
-
-
S&F in repairs submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLSH copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 6 sqmm dia FRLSH PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one runs of 6 sq.mm copper earth continuity conductor shall be measured as one unit length.
(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
(iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces.
75
-
-
S&F in repairs submain wiring with 2 runs of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLSH copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 10 sqmm dia FRLSH PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 10 sq.mm copper conductor, one runs of 10 sq.mm copper earth continuity conductor shall be measured as one unit length.
(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
(iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces.
75
-
-
Earthing complete with GI earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed.
NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate.
(b) Rate quoted shall deemed to include GI earth strip and GI protection pipe light grade.
(c) Rate quoted shall deemed to include taking down old items. (d) Minimum 100 Kg salt and 100 Kg charcoal granual type to be used for each earth pit. The bed to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal in aternate.
(e) PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr.
2
-
-
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.
2
-
-
M & L in replacement of Central display unit and control unit (20+8) modules with data process and control unit upto 4 digit numeric display for a bed/ toilet complete all as specified and directed. (Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/ GADDIEL)
3
-
-
M&L in replacement of bed side calling unit (Wired) with attached patient hand set with LED indication complete all as specified and directed . (Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/ GADDIEL)
125
-
-
M&L in replacement of Toilet emergency calling unit with attached pull cord (Wired) complete all as specified and directed. (Make : OPTIMUM SOLUTIONS/ AMIL CALLING BELL SYSTEM/GADDIEL)
30
-
-
M&L in replacement of Cat 6 cable for connection from central display unit to bed side calling point complete all as specified and directed . (Make : HAVELLS/D LINK/ FINOLEX/PLAZA).
375
-
-
M & L in replacement of (heavy duty) 20 mm dia, rigid non metallic PVC conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
350
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%